Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “outdoor testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A study of degradation mechanisms in PVDF-based photovoltaic backsheets

Abstract Commercial backsheets based on polyvinylidene fluoride (PVDF) can experience premature field failures in the form of outer layer cracking. This work seeks to provide a better understanding of the changes in material properties that lead to crack formation and find appropriate accelerated tests to replicate them. The PVDF-based backsheet outer layer can have a different structure and composition, and is often blended with a poly(methyl methacrylate) (PMMA) polymer. We observed depletion of PMMA upon aging with sequential (MAST) and combined (C-AST) accelerated stress testing. In field-aged samples from Arizona and India, where PVDF crystallizes in its predominant α-phase, the degree of crystallinity greatly increased. MAST and C-AST protocols were, to some extent, able to replicate the increase in crystallinity seen in PVDF after ~ 7 years in the field, but no single-stress test condition (UV, damp heat, thermal cycling) resulted in significant changes in the material properties. The MAST regimen used here was too extreme to produce realistic degradation, but the test was useful in discovering weaknesses of the particular PVDF-based outer layer structure studied. No excessive β-phase formation was observed after aging with any test condition; however, the presence of β-phase was identified locally by Fourier transform infrared spectroscopy (FTIR). We conclude that both MAST and C-AST are relevant tests for screening outdoor failure mechanisms in PVDF backsheets, as they were successful in producing material degradation that led to cracking.

14 SOLAR ENERGY↗

CSP Optical Facilities at the National Renewable Energy Laboratory

The concentrating Solar Power (CSP) Optical Facilities at NREL comprise unique optical tools and facilities for testing and characterizing concentrating solar optical components. These facilities are maintained to aid researchers and industry efforts to reduce market barriers, improve the performance, reduce the cost, and improve the lifetime and reliability of CSP materials, components, subsystems, and integrated concepts, where accurate and timely characterization methods are needed. To reach this goal, NREL is committed to collaborating in ongoing and projected research needs for industry, academia, and government entities, in the development and characterization of low-cost, high-performance reflector and absorber materials in addition to their components-a key element in the conversion of concentrated sunlight into energy. To accomplish this mission, the core laboratory includes the Advanced Optical Materials Laboratory, indoor and outdoor accelerated weather testing tools, "Distant Observer" for parabolic troughs, the High Flux Solar Furnace, and the ultra-accelerated weather testing tools. This equipment enables to rapidly respond to new challenges with novel solutions that align with the goals of the Solar Energy Technology Office (SETO) at the U.S. Department of Energy. The goal of this paper is to present the state-of art-optical facilities available at NREL that can help support the research needs of the CSP community. Therefore, we review here the different components of the CSP Optical Facilities at NREL and highlight their characteristics and importance for the CSP community.

accelerated weather testing↗

Medium-Voltage Testbed for Comparing Advanced Power Line Sensors vs. Measurement Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medi-um-voltage sensor is compared with a reference PT and CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the US De-partment of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with integrator for current monitoring. The advanced outdoor power line sensor testbed has a real-time simulator that was used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, service restoration), while the analog signals were recorded by the same high resolution power meter. The behavior of analog signals, harmonic components, total harmonic distortion, and crest factors were assessed for this power line sensor compared with the reference PT/CT, because of the absence for testing standards for advanced outdoor power line sensors.

Piesciorovsky, Emilio↗

Experimental Considerations for Estimating Degradation in PV Modules

Carefully controlled laboratory experiments and measurements can enable the determination of acceleration factors suitable for extrapolation to durability and performance of a fielded PV module. Ideally, a single mechanism can be identified with appropriate acceleration factors for extrapolation to the field. However, even with a single mechanism, the inherent uncertainty in these factors leads to uncertainty in the extrapolation which is greater the higher the acceleration factor. This course will explain how because of the wide range of acceleration factors for a given degradation mode, utilizing acceleration factors greater than about 10x will typically lead to unacceptable uncertainty in the results. Therefore, if even just a rank ordering of materials is desired, acceleration factors must be minimized which requires a good general understanding of the scale of the different acceleration factors for the degradation mode of interest. In this tutorial we will discuss what the different purposes are for many of the accelerated stress tests used today. E.g., what is a qualification test, a highly accelerated stress test, a rank ordering test, or a service life prediction test. We will discuss how one can understand the relationship between test results and expected field performance. A single accelerated stress test condition cannot duplicate outdoor exposure for all possible degradation pathways; therefore, one must use targeted evaluation of material properties at different stress levels to determine the relevant acceleration factors and fit it to a model. We will also discuss how to interpret the results of experiments understanding what is relevant/not relevant, or not e valuated in a test. There are many common error people make in their test interpretations because they push the stress levels to be too harsh. This creates biases and can mask the relevant failure modes and mechanisms or will erroneously lead one to over design materials against things that aren't relevant. Several case studies will be presented to illustrate appropriate interpretation of accelerated stress testing results.

degradation↗

Systematic Operating Temperature Differences Between Al-BSF, PERC, and PERT-With-Optimized-Rear-Reflector Solar Mini-Modules Due to Rear Reflectance

Reflecting sub-bandgap light from photovoltaic modules has the potential to improve lifetime energy generation of fielded systems by reducing operating temperature. In this article, the temperature of fielded aluminum back-surface field (Al-BSF) and passivated emitter and rear contact (PERC) mini-modules was monitored every 5 minutes for 75 days along with corresponding meteorological data. Additionally, passivated emitter rear totally diffused (PERT) mini-modules with high-performance sub-bandgap rear reflectors were tested and compared to the state-of-the-art industrial modules. These reflectors consisted of a >300-nm-thick silicon dioxide nanoparticle film with a low refractive index. The impact of reflectance on measured operating temperature was isolated with a previously developed thermal model and quantified as the reflectance-induced median temperature difference between each tested module at representative outdoor conditions (1000 W m -2 , 25 degrees C ambient temperature, and 1.43 m s -1 wind speed). We found that, because of their reflectance differences, PERC modules ran systematically cooler than Al-BSF modules by 1.0 degrees C, whereas the PERT-with-optimized-rear-reflector systematically operated 1.4 degrees C cooler than the Al-BSF module and 0.4 degrees C than the PERC module. We also found that the rear reflector provided the greatest temperature benefit during periods of highest irradiance.

14 SOLAR ENERGY↗

A streamlined approach to characterize microalgae strains for biomass productivity under dynamic climate simulation conditions

Screening microalgae strains under static light and temperature flask conditions cannot directly quantify the biomass productivities of algae growing in the dynamically fluctuating light and temperature conditions of outdoor ponds. In this effort, we describe a testing pipeline that screens for productivity under climate simulated conditions. A validated, miniaturized Laboratory Environmental Algae Pond Simulator (mini-LEAPS) photobioreactor was used to determine optimal medium salinities and biomass productivities of cold-tolerant microalgae collected from Arctic, subarctic, Antarctic, and subalpine habitats. Strains characterized in this effort include: Chlorella antarctica UTEX1959, Chlorella sp. UTEXSNO69, Chloromonas rosae UTEXSNO11, Phaeodactylum tricornutum UTEX646, and Stichococcus minutus CCALA727. Observed productivities of the characterized strains ranged from 1.74 ± 0.25 to 8.18 ± 0.81 g m –2 day –1 (as ash-free dry weight). For each strain, a temperature tolerance profile was generated to identify the most appropriate season (s) for cultivation. The two most promising strains, Chlorella sp. UTEX SNO69 and P. tricornutum UTEX646, were tested alongside the DISCOVR winter benchmark strain Monoraphidium minutum 26B-AM in outdoor open ponds at the PNNL Algae Testbed (PAT) in Arizona. Further, under cold-season outdoor pond conditions, Chlorella sp. UTEXSNO69 achieved average areal biomass productivities of 8.21 ± 0.50 g m –2 day –1 , not significantly different from that of the benchmark strain (8.52 ± 0.43 g m –2 day –1 , p > 0.05). Under spring outdoor pond conditions, P. tricornutum UTEX646 achieved average areal biomass productivities 10.34 ± 0.27 g m –2 day –1 , not significantly different from that of the benchmark (10.07 ± 0.50 g m –2 day –1 ) under the tested conditions (p > 0.05). The streamlined pipeline was thus demonstrated to successfully characterize productive microalgae strains for outdoor deployment by weeding out algae strains that were not productive under the tested dynamic light and temperature conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Challenges, Technological Pathways and Trade-Offs of Perovskite Solar Modules for Long-Term Operation

Perovskite solar modules (PSMs) have emerged as a promising photovoltaic technology due to their high efficiency, low fabrication cost and compatibility with lightweight and flexible applications. However, ensuring long-term reliable performance under real-world conditions remains a critical barrier to commercialization. PSMs degrade through mechanisms that differ substantially from those affecting established technologies such as silicon, particularly under environmental stressors like ultraviolet light, oxygen, temperature cycling and reverse bias. Here we provide an analysis of the degradation pathways specific to perovskite modules and discuss why standard accelerated tests often fail to predict outdoor performance. We conceptualize challenges across material, device and module levels and evaluate strategies to mitigate ion migration, interfacial breakdown and encapsulation failure. By highlighting the need for realistic testing protocols and durable materials, we propose a framework highlighting key challenges, technological pathways and the trade-offs required to extend perovskite module lifetimes towards long-term operation, aiming to guide the development of PSMs capable of a 30-year operational lifetime.

14 SOLAR ENERGY↗

Oxygen stress mitigation for microalgal biomass productivity improvement in outdoor raceway ponds

Dissolved oxygen (DO) concentrations at supersaturated levels are commonly observed in outdoor microalgae cultures due to photosynthesis during periods of rapid growth. Paradoxically, the photosynthetically generated oxygen is inhibitory and lowers biomass productivity, therefore, increasing the cost of microalgal biofuels. In this study, photosynthetic rates of Monoraphidium minutum 26B-AM and Scenedesmus obliquus UTEX393, two of the top DISCOVR strains, were compared at three DO levels, 0, 8, and 30 mg L -1 . Increasing DO from 0 to 30 mg L -1 caused a 36.6% and 26.1% reduction in photosynthetic rate for M. minutum 26B-AM and S. obliquus UTEX393, respectively. To improve the outdoor pond biomass productivity of each strain, three oxygen stress mitigation methods were tested. The first method raised the dissolved bicarbonate concentration by an order of magnitude to favor bicarbonate transport into the cell, increasing the CO 2 :O 2 ratio near RuBisCO, thus reducing photorespiration. Although this method increased the observed photosynthesis rate of M. minutum 26B-AM by 26% and S. obliquus UTEX393 by 13% in laboratory testing, it failed to improve biomass productivity under outdoor pond conditions for both strains. The second method added sodium sulfite as an oxygen scavenger to chemically lower the DO concentration in the culture. Chemical reduction of dissolved molecular oxygen did not significantly improve the biomass productivity of M. minutum 26B-AM; however, a 10% improvement in biomass productivity for S. obliquus UTEX393 was observed. The final method sparged cultures with air to strip oxygen out of the liquid medium. This did not improve the biomass productivity of M. minutum 26B-AM, likely due to unfavorable weather conditions during cold season cultivation; however, an improvement of 36% in biomass productivity was achieved for S. obliquus UTEX393 during the warm season cultivation. Of the three tested methods, air-sparging was the most effective and practical for improving outdoor biomass production.

59 BASIC BIOLOGICAL SCIENCES↗

Performance Modeling of Tandem Photovoltaics: A Yearlong Outdoor Degradation Analysis of a Ga⁢As//Si Minimodule

We present a performance modeling and degradation analysis framework for tandem photovoltaic modules, building upon established procedures for crystalline silicon devices and adapting them to account for the spectral sensitivity of multijunction technologies. The methodology employs filter criteria to select outdoor measurements close to standard test conditions (STC) under stable spectral and ambient conditions, followed by normalization of power production data with corrections for temperature, irradiance, and precipitable water vapor. We demonstrate this framework using a mechanically stacked four-terminal gallium arsenide (Ga⁢As) // silicon (Si) tandem solar minimodule deployed outdoors from October 2019 to January 2021 in Golden, Colorado, USA. We determined degradation rates of −4.1 ±0.2%/year for the Ga⁢As subcell and −2.5 ±0.9%/year for the Si subcell, with analysis of individual performance metrics indicating that packaging degradation, particularly delamination, was the dominant failure mode. Simulations using PVcircuit, an open-source equivalent-circuit solver, confirmed these findings. The presented methodology provides a reproducible foundation for performance modeling and degradation analysis of emerging tandem technologies.

14 SOLAR ENERGY↗

Outdoor Deployment Data for a Four-Terminal GaAs//Si Tandem Solar Mini-Module

This dataset contains the complete outdoor measurement and analysis data for a mechanically stacked, four-terminal (4T) gallium arsenide (GaAs)//silicon (Si) tandem solar mini-module deployed from October 2019 to January 2021 at the Solar Radiation Research Laboratory (SRRL) in Golden, Colorado, USA. The data support a performance modeling and degradation analysis framework for tandem photovoltaic devices, as described in the accompanying publication. The dataset includes: (1) current–voltage (J–V) characteristics of each sub-cell measured approximately every five minutes, with extracted performance parameters; (2) spectral irradiance from an EKO MS-710 WISER spectroradiometer, along with derived spectral mismatch ratios (SMR) and average photon energy (APE); (3) one-minute resolution meteorological data from the co-located SRRL weather station and GPS-derived precipitable water vapor (PWV); (4) pre-deployment laboratory characterization (external quantum efficiency, J–V curves, standard test conditions parameters); (5) outdoor-extracted temperature and PWV correction coefficients; and (6) PVcircuit equivalent-circuit simulation outputs used for model validation. Degradation rates of −4.1 ± 0.2 %/year (GaAs) and −2.5 ± 0.9 %/year (Si) were determined using a filtering and normalization methodology adapted for fixed-tilt tandem modules. All data are provided in open, portable formats (Apache Parquet, CSV, JSON) to enable full reproducibility of the published analysis.

14 SOLAR ENERGY↗

PACT Data Management Plan (V.1.0)

The Perovskite PV Accelerator for Commercial Technology (PACT) is an independent validation center for the evaluation of perovskite PV technologies and their bankability. The center is led by Sandia National Laboratories and the National Renewable Energy Laboratory (NREL) and includes as part of its team Los Alamos National Laboratory (LANL), CFV Labs, Black and Veatch (B&V), and the Electric Power Research Institute (EPRI). The goals of the center are to: Develop and improve indoor and outdoor performance characterization methods, Develop and validate accelerated qualification testing for early failures (5-10 years), Research degradation and failure modes, Validate outdoor performance, and Provide bankability services to US perovskite PV (PSC) industry. The importance of data and data management to the success and outcomes of the PACT center is paramount. This report describes how data will be managed and protected by PACT and identifies important data management principles that will guide our approach.

14 SOLAR ENERGY↗

Smart detection of indoor occupant thermal state via infrared thermography, computer vision, and machine learning

The ability to measure occupants’ thermal state in real time will enable major advances in the control of air conditioning systems. This study proposes predicting occupant thermal state by a combination of infrared thermography, computer vision, and machine learning. The approach (1) uses cheek, nose, and hand temperatures because they are least subject to blockage by hair, glasses, and clothing; (2) measures the distribution of skin temperatures within geometrically defined sub-areas of the face and hand; and (3) uses temperature differences within and between these areas to eliminate the effects of calibration drift that are unavoidable in thermal infrared (TIR) cameras. Two series of tests were conducted, respectively in an outdoor carport and an indoor environmental chamber, collecting a total of 48,422 sets of cheek, nose, and hand skin temperatures using a TIR camera and computer-vision technology, coupled with 715 subjective responses of thermal sensations. To predict occupant thermal state, Random Forest classification models were built using either absolute skin temperatures (the maximum and median temperatures of cheek and hand segments, and the temperature of the central spot on the nose), or intra- and inter-segment temperature differences of cheeks, hands, and nose. These measurements were found to accurately predict occupant thermal state. Using the maximum and median temperatures for cheek and nose, or for cheek and hand, predicts thermal state with an accuracy of 92–96%. In conclusion, using only the intra- and inter-segment temperature differences from cheek and nose is 83% accurate; adding the hand temperature differences increases the accuracy to 96%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Testing and Performance Characterization of the High Efficiency Dehumidification System (HEDS) Technology

The high efficiency dehumidification system (HEDS) is a unique air handling unit (AHU) design with two water coils. Connected in series, these water coils can sensibly reheat the airstream after it is cooled and dehumidified, thereby mitigating (or sometimes eliminating) the need for conventional sensible reheat with additional energy from hot water, electric resistance or steam coils. Another unique design feature is the size of the HEDS primary cooling coil. While typical AHU cooling coils have a 6-row geometry, the HED's cooling coil has a deeper 10-row geometry enabling discharge air dew point temperatures at or below 55 degrees F despite warmer chilled water supply temperatures approaching (sometimes exceeding) 50 degrees F. The ability to meet acceptable discharge air dew points with warmer chilled water supply temperatures improves both operational efficiency and system resilience against chilled water plant operational or control issues. This report summarizes the 59 steady-state test results that form a comprehensive performance map of the HEDS technology including its reheat capability. The breadth of outdoor air conditions and flow rates over which the HEDS technology was tested and characterized encompasses the unit 1) operating as a dedicated outdoor air system or mixed air system and 2) controlled with constant air volume or variable air volume fan control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

DISCOVR strain pipeline screening – Part II: Winter and summer season areal productivities and biomass compositional shifts in climate-simulation photobioreactor cultures

Assessing the seasonal biomass productivity and compositional shift dynamics under simulated outdoor culture conditions of the top 22 algae strains selected during Tier I flask screening is an important step in the further prioritization of strains with regard to outdoor pond cultivation. These top 22 strains were subjected to Tier II testing in the PNNL Laboratory Environmental Algae Pond Simulator (LEAPS) photobioreactors, simulating light and temperature conditions of 20 cm deep outdoor ponds during the Arizona winter and summer season. All strains were grown in two consecutive nutrient-replete batch culture experiments at their particular optimal medium salinity to quantify their respective seasonal linear-phase areal biomass productivities. To determine biomass compositional shifts in response to nutrient-depletion, the LEAPS cultures were allowed to enter a 9-day nutrient depletion phase at the end of the second batch run. The following strains were evaluated in winter-season climate-simulated cultures and are listed in the order from highest (7.9 g m -2 day -1 ) to lowest (2.3 g m -2 day -1 ) areal N-replete biomass productivity: Monoraphidium minutum 26B-AM, Tetraselmis striata LANL1001, Chlorella vulgaris LRB AZ-1201, Micractinium reisseri NREL14-F2, Monoraphidium sp. MONOR1, Chlorella vulgaris NREL4-C12, Scenedesmus obliquus UTEX393, Scenedesmus acutus LRB-AP-0401, Nannochloropsis oceanica CCAP849/10, and Stichococcus minutus CCALA727. The following strains were evaluated in summer-season climate-simulated cultures and are listed in the order from highest (31.8 g m -2 day -1 ) to lowest (14.2 g m -2 day -1 ) areal N-replete biomass productivity: Picochlorum renovo NREL39-A8, Scenedesmus obliquus UTEX393, Porphyridium cruentum CCMP675, Picochlorum celeri TG2-WT-CSM/EMRE, Chlorella sorokiniana DOE1116, Stichococcus minor CCMP819, Picochlorum oklahomensis CCMP2329, Chlorella sorokiniana DOE1412 (UTEXB3016), Scenedesmus rubescens NREL46B-D3, Picochlorum soloecismus DOE101, Tetraselmis striata LANL1001, Scenedesmus obliquus DOE 0152.z, and Agmenellum quadruplicatum UTEX2268. All LEAPS cultures experienced a significant reduction in areal biomass productivity in response to nutrient-depletion, from 7-16% in the winter season simulation and up to 1-60% in the summer season simulation. Finally, for 10 of the strains tested, the carbohydrate content more than doubled upon nutrient depletion, and for 9 strains, the lipid content increased by over 50% of the initial content.

09 BIOMASS FUELS↗

Development of a forced advection sampling technique (FAST) for quantification of methane emissions from orphaned wells

Abstract. Orphaned wells, meaning unplugged and non-producing wells lacking responsible owners, pose a significant and undersampled environmental challenge due to their vast number and unknown associated emissions. We propose, develop and test an alternative method for estimating emissions from orphaned wells using a forced advection sampling technique (FAST) that can overcome many of the limitations in current methods (cost, accuracy, safety). In contrast to existing ambient Gaussian plume methods, our approach uses a fan-generated flow to force advection between the emission source and a point methane (CH4) sensor. The fan flow field is characterized using a colocated sonic anemometer to measure the 3D wind profile generated by the fan. Using time-series measurements of CH4 concentration and wind, a simple estimate of the CH4 emission rate of the source can be inferred. The method was calibrated using outdoor controlled-release experiments and then tested on four orphaned wells in Lufkin, TX, and Osage County, OK. Our results suggest that the FAST method can provide a low-cost, portable, fast and safe alternative to existing methods with reasonable estimates of orphaned well emissions over a range of leak rates below 40 g h−1 and within certain geometric and atmospheric constraints.

Dubey, Mohit L↗

High‑performance cold‑climate heat pump using tandem compressors with and without vapor injection: Laboratory investigation and field demonstration

Cold‑climate air‑source heat pumps must maintain heating capacity and stable operation at low ambient temperatures for residential applications. This study adapts tandem single-speed compressors—proven in commercial systems —for residential CCHPs, integrating VI and validating performance across laboratory and extreme field conditions to achieve cold-climate targets. That is to achieve ≥75% of the rated heating capacity at −25.0 °C relative to 8.3 °C and heating coefficient of performance (COP) greater than 4.0 at 8.3 °C. Laboratory testing confirmed that both configurations met these targets while operating within acceptable discharge‑temperature limits. Relative to the non‑VI configuration, the VI system provided up to 15% higher heating capacity and up to 9% higher heating COP under identical conditions, yielding a 5.6–9.1% increase in heating seasonal performance factor (HSPF). Field tests in Ohio and Alaska, with minimum outdoor temperatures of −25.0 °C and −34.0 °C, respectively, showed stable operation, minimal supplemental heating (<3.2%), low defrost penalties, and consistent output. Tandem‑compressor architectures proves promising for cold-climate residential heating.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 1: Particulate and gaseous emissions

This study investigated how heat demand and fuel loading affect the emissions from outdoor wood-fired hydronic heaters by testing two such appliances using an integrated-duty cycle test method. This test included transient operating conditions, such as cold and hot-starts and modulation between 15 and 100% of maximum rated output. Emission values indicate transient operating conditions produce higher emissions than steady state operation. Cold starts resulted in elevated particulate matter emission factors for both appliances; in one case the particulate matter emission factor for this period was >3500 mg/MJ, which represented emissions 20 times the average value. Additionally, when heat demand was cycled—elevated CO emission factors were measured, with values >5000 mg/MJ for both appliances and more than 3 times the appliance averages, respectively. It follows that the appliance average particulate matter emission factors and CO emission factors were not representative of the actual EF values during these transient periods. In contrast, methane emission factors were relatively stable throughout all tested combustion conditions; however, they were much higher than oil-fired appliances are therefore should not be ignored. These findings demonstrate that wood-fired hydronic heater emissions during transient operating conditions can be significantly greater than emissions during steady-state test conditions, such as those used in typical certification tests. Consequently, certification test values for particulate matter and CO emission factors may significantly underestimate the actual emissions of these appliances when operated in a home. Use of integrated duty-cycle test protocols that capture cold-starts and reloading are better for representing in-use operations of wood-fired hydronic heaters and provide more realistic emissions and delivered efficiency measurements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental investigation on thermal inertia characterization of commercial buildings for demand response

Characterizing the thermal inertia of commercial buildings is of great importance in quantifying demand flexibility. Experimental tests can be used to investigate the thermal inertia of commercial buildings. However, existing studies tend to be qualitative and have limited scope. In this study, a comprehensive field test has been performed to assess the thermal inertia of commercial buildings. In this field test, six buildings are selected with different sizes, vintages, and types of heating, ventilation, and air conditioning (HVAC) systems to represent the majority of the U.S. commercial building stock. We quantify the thermal inertia with building operation data collected under various thermostat excitation signals. We then studied the relationship between thermal inertia and intrinsic properties, such as floor area, HVAC system, etc., as well as the operation condition indicators such as outdoor air temperature, zone temperature, and occupancy. The testing results indicate that the median values of the normalized charge response time and the normalized discharge response time of the five buildings are 1~5 hr/ °C and -5~-1 hr/ °C, respectively. The results also show that the thermal inertia of commercial buildings may be sensitive to the HVAC system type but not the floor area or location of zones, i.e., core vs. perimeter. Finally, our results suggest that the relationships between the charging/discharging normalized response time and the zone/outdoor temperature may vary among zones and be highly nonlinear.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗