Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “oscillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Novel Cascaded Ring Oscillator Vernier based TDC Architecture with a Feedthrough Reference Oscillator

Time to digital converters (TDCs) are widely used in particle physics and medical imaging to determine the relative arrival time of photons and other particles. Vernier TDCs are one of the most attractive options due to their power consumption efficiency and their small footprint. We present our newly patented innovative architecture of cascaded-stage Vernier TDCs comprised of a feedthrough reference oscillator. This architecture lead to successive Vernier measurements that result in a lower number of cycles for the same dynamic range to resolution ratio (DRRR), leading to reduced conversion time and lower jitter. To validate this architecture, a test chip was designed in 0.18~μm TSMC technology, integrating four types of cascaded Vernier TDCs with an increasing number of stages. The performance of the chip was assessed using a modular test platform specifically designed for TDCs. For comparison purposes, all TDCs were tested with a LSB of 50~ps and a dynamic range of 20~ns. The experimental results demonstrate the highest gain in performance between 1 stage Vernier and 2 stage Vernier TDCs with the precision improved from 36~ps~rms to 21~ps~rms, the maximum number of turns from 110 to 25 counts and the dead time, from 266.4~ns to 76.5~ns, on average. Adding Vernier stages is only relevant for a higher DRRR. Therefore, the 3-stage and 4-stage Vernier TDCs also show performance gains, but improvements are limited.

Scarpellini, Robin↗

Oscillations in an isothermal atmosphere - The solar five-minute oscillations.

The motions generated in an atmosphere by pressure fluctuations at its base have been investigated. Particular attention was given to the problem of whether there is a divergence in the velocity amplitude at any particular frequency. Two of the current interpretations of observed oscillations of the solar atmosphere, for which the expected motion in the atmosphere is very similar, are discussed.

Worrall, G.↗

Numerical analysis of spectral properties of coupled oscillator Schroedinger operators. I - Single and double well anharmonic oscillators

Several methods for computing many eigenvalues and eigenfunctions of a single anharmonic oscillator Schroedinger operator whose potential may have one or two minima are described. One of the methods requires the solution of an ill-conditioned generalized eigenvalue problem. This method has the virtue of using a bounded amount of work to achieve a given accuracy in both the single and double well regions. Rigorous bounds are given, and it is proved that the approximations converge faster than any inverse power of the size of the matrices needed to compute them. The results of computations for the g:phi(4):1 theory are presented. These results indicate that the methods actually converge exponentially fast.

Isaacson, D.↗

Bound oscillations on thin magnetic flux tubes - Convective instability and umbral oscillations

The possibility that 'tube waves' can be trapped on slender solar magnetic flux tubes is investigated. For rigid isothermal flux tubes, it is found that the flux tube geometry can by itself lead to waves which are trapped on the part of the tube that expands with height. Some geometries lead to trapped modes with eigenperiods near 180 s, if parameters appropriate to sunspot umbrae are chosen. It is possible that the umbral oscillations are a manifestation of such trapped waves, if sunspot umbrae consist of an assembly of slender flux tubes, as in the spaghetti model of Parker (1979). For flux tubes which have a constant ratio of Alfven speed to sound speed, it is found that it is primarily the variation of temperature with height which determines whether trapped waves can exist. Certain temperature profiles lead to disturbances for which omega squared is less than zero, corresponding to convective instability or Rayleigh-Taylor instability.

Hollweg, J. V.↗

Measurement of precision oscillator phase noise using the two-oscillator coherent down-conversion technique

The characterization of precision frequency standard phase noise and spurious outputs is addressed, using the two-oscillator coherent downconversion technique. Focus is on techniques for making accurate measurements of phase noise and spurious outputs within 100 KHz of a carrier. Significant sources of measurement error related to hardware design problems and inadequate measurement procedures are discussed: measurement errors resulting from system noise sources, phase-locked loop effects, and system bandwidth limitations. In addition, methods and design considerations for minimizing the effects of such errors are presented. Analytic discussions and results are supplemented with actual test data and measurements made using measurement hardware developed at the Ball Corporation, Efratom Division.

Christopher J. Pagnanelli↗

Methods for the Automated Determination of Sustained Maximum Amplitudes in Oscillating Signals

Machine condition monitoring has been proven to reduce machine downtime and increase productivity. The state-of-the-art research uses vibration monitoring for tasks such as maintenance and tool wear prediction. A less explored aspect is how vibration monitoring might be used to monitor equipment sensitive to vibration. In a manufacturing environment, one example of where this might be needed is in monitoring the vibration of optical linear encoders used in high-precision machine tools and coordinate measuring machines. Monitoring the vibration of sensitive equipment presents a unique case for vibration monitoring because an accurate calculation of the maximum sustained vibration is needed, as opposed to extracting trends from the data. To do this, techniques for determining sustained peaks in vibration signals are needed. Here, this work fills this gap by formalizing and testing methods for determining sustained vibration amplitudes. The methods are tested on simulated signals based on experimental data. Results show that processing the signal directly with the novel Expire Timer method produces the smallest amounts of error on average under various test conditions. Additionally, this method can operate in real-time on streaming vibration data.

Industrial Internet of Things↗