Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optimal operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Operational optimization for multi-functional charging station with electric and hydrogen-powered vehicles

The rapid adoption of electric vehicles (EVs) and hydrogen fuel cell vehicles (HFCVs), combined with global efforts to reduce carbon emissions, has accelerated the development of EV charging and hydrogen refueling stations. In response to this demand, this paper introduces the concept of Multi-Functional Charging Station (MFCS) that integrates power generation, EV charging, battery swapping, and hydrogen refueling. A comprehensive operational model is developed for the MFCS that couples electricity and hydrogen conversion and storage technologies to enhance infrastructure utilization and improve overall system efficiency. The model also considers multiple revenue streams, including participation in energy and ancillary markets. To validate the effectiveness of the proposed model and evaluate its performance, a series of numerical experiments are conducted with different charger numbers, different electricity purchase limits, and different charger allocations. Numerical results demonstrate that shared charger configurations can lead to 8.11 % improvement in operational profit by improving resource utilization and reducing the number of depleted batteries at the end of operations compared to allocated charger setups. By varying the number of chargers, sensitivity analysis identifies diminishing marginal returns beyond about 45 chargers, suggesting it as an optimal sizing point under current settings. The integration of electricity and hydrogen conversion is also explored under scenarios with limited external electricity purchases. In conclusion, these findings indicate that optimizing charger allocation and energy management can significantly enhance station productivity and profitability, ultimately supporting the broader adoption of electrified and hydrogen-based transportation solutions.

Charging station↗

Optimal Operation of Solid-Oxide Electrolysis Cell Systems Considering Synergistic Chemical and Physical Degradation

This poster summarizes work on synergistic degradation of Solid-Oxide Cells under physical and chemical degradation. We present operational insights that extend the useful life of SOCs while maintaining high efficiencies and economic viability. We also provide insights on how often the SOC must be replaced to ensure the reliability of the process. All these decisions are made through a dynamic optimization framework that utilizes new models for degradation that were developed as a part of the IDAES project.

Giridhar, Nishant↗

Estimates of Optimal Operating Conditions for Hydrogen-Oxygen Cesium-Seeded Magnetohydrodynamic Power Generator

The value of percent seed, oxygen to fuel ratio, combustion pressure, Mach number, and magnetic field strength which maximize either the electrical conductivity or power density at the entrance of an MHD power generator was obtained. The working fluid is the combustion product of H2 and O2 seeded with CsOH. The ideal theoretical segmented Faraday generator along with an empirical form found from correlating the data of many experimenters working with generators of different sizes, electrode configurations, and working fluids, are investigated. The conductivity and power densities optimize at a seed fraction of 3.5 mole percent and an oxygen to hydrogen weight ratio of 7.5. The optimum values of combustion pressure and Mach number depend on the operating magnetic field strength.

Smith, J. M.↗

Optimal operation and sizing of pumped thermal energy storage for net benefits maximization

Abstract Current trends in the modern grid are leading to the development and deployment of energy storage to help integrate increasing variable renewable energy sources into the grid. This paper studies a pumped thermal energy storage (PTES) system for multiple grid services including energy arbitrage, frequency regulation, spinning and non‐spinning reserve, and resource adequacy. Optimal dispatch methods are proposed for individual services as well as value stacking from multiple services to maximize the economic benefits. Assessment results demonstrate the superiority of value stacking. Specifically, the study shows the maximum revenue from an individual grid service with a 30‐MWh PTES system was $522,520, while the value stacking could increase the benefits to $678,477. In addition, sensitivity analyses were conducted to explore the cost‐effectiveness of a PTES system with different combinations of power transfer limits and energy capacity. It was found that the power transfer limit had a greater impact than the energy capacity on the benefits. The proposed method could help determine the optimal duration of a future PTES system.

25 ENERGY STORAGE↗

Reinforcement Learning to Enhance Optimal Operation of Resilient Community Energy Systems

This paper presents a novel model-free multi-agent Reinforcement Learning (RL) control method to enhance the resilience of community energy systems in island mode, which coordinates multiple objectives without the necessity of identifying system models that require expert knowledge. Specifically, a community-level coordinator agent is designed to allocate renewable energy resources among different buildings, and multiple building-level agents are developed to optimize load schedules based on limited energy resources and requirements of building loads and occupants’ comfort. In a two-day evaluation, our RL approach demonstrated a similar performance against MPC without requiring system models and formulation of optimization problems as required in MPC.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Optimal Operation for Resilient and Economic Modes in an Islanded Alaskan Grid: Preprint

Power System is a complex system, with an objective to provide power to the customers. The objective is driven by a complex consideration of the secure, economic and resilient operation of the system. With the growing occurrence of extreme events emphasis has been shifted towards making the grid more resilient. However, an economic operation is still a priority for the utilities as well as its customers. Many utilities especially small isolated micro-grids do not emphasize much on an economic and resilient operation, but more on reliability. In this research we focus on striking a balance between economic and resilientoperation, ensuring reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Operation of Residential High Performance Water Heater for Reduction of Electricity Cost and Peak Demand Through Field Validation

Water heating accounts for about 18% of a typical US home’s energy use. Modern water heaters have enabled control options through APIs, offering customers the opportunity to reduce their energy cost and peak demand by dynamically adjusting settings. A water heater’s capacity to store energy using its storage tank makes it an asset for peak demand reduction and energy cost savings. For this reason, a mixed-integer linear programming model is proposed to minimize the energy cost of a high-performance water heater while also reducing the peak demand of the residential household under a time-of-use utility rate by dynamically changing the water heater’s running mode. Specifically, a multi-objective optimization model is formulated to determine the mode settings of the water heater considering hot water use, time-of-use rate, and peak demand limit of the residential household. The mode settings are associated with different dead bands of water temperature for triggering on/off action of the heat pump and heating element. A 66-gal hybrid electric high performance water heater was used for numerical simulation and practical experiments. The simulation results were well aligned with measurements of practical experiments, validating the soundness of the thermodynamic model. In addition, reductions of energy cost, enabling affordability, and reducing peak demand are demonstrated. The research team also developed a software framework with dashboards to automatically and continuously monitor and manage devices.

Liu, Guodong [ORNL] (ORCID:0000000213498608)↗

Using the Stix finite element RF code to investigate operation optimization of the ICRF antenna on Alcator C-Mod

Abstract As the Ion Cyclotron Radio Frequency range (ICRF) heating becomes more favorable in fusion devices, the urgency of predicting and mitigating impurity generation that arises from it becomes more pressing. In the ICRF regime, rectified Radio Frequency (RF) sheaths are known to form at antenna and material edges that influence negative effects like sputtering and a decrease in heating efficiency. Methods to mitigate the formation of these RF sheaths through RF image currents cancellation have been experimentally studied. A power-phasing scan done on Alcator C-Mod in which the amount of power on the two inner straps ( P in ) versus the total 4 straps ( P tot ) was varied showed a minimization of enhanced potentials between P in / P tot ∼ 0.7–0.9 while impurities were minimized for P in / P tot ∼ 0.5–0.8. New capabilities in the realm of representing the RF sheath numerically now allow for these experiments to be simulated. Given the size of the sheath relative to the scale of the device, it can be approximated as a Boundary Condition (BC). A new parallelized cold-plasma wave equation solver called Stix implements a non-linear sheath impedance model BC formulated by Myra et al (2015 Phys. Plasmas 22 062507) through the method of finite elements using the MFEM library [ http://mfem.org ]. It is seen that Stix shows qualitative agreement with the measured C-Mod enhanced potentials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrated Modeling and Optimal Operation of Multi-Energy System for Coastal Community

Focusing on remote, isolated, and underserved communities, a multi-energy system is designed in this research which is capable of utilizing different energy sources in a more coordinated and energy-efficient way to support various demands, such as fresh water, electricity, hydrogen, thermal demand, etc. The energy sources considered are renewables (wind, solar, marine) and natural gas. The energy conversion process includes water desalination, gas combustion, water electrolyzation, and different types of storage (hydrogen tank, electricity, thermal, etc.) are designed to serve as buffers in supply-demand balancing. Sets of experiments are designed to demonstrate the effectiveness of the proposed operating model and investigate the impact of uncertainties from renewable generations and demands.

Chen, Yang↗

Theoretical Analysis of Critical Conditions for Crack Formation and Propagation, and Optimal Operation of SOECs

A theoretical analysis on crack formation and propagation was performed based on the coupling between the electrochemical process, classical elasticity, and fracture mechanics. The chemical potential of oxygen, thus oxygen partial pressure, at the oxygen electrode-electrolyte interface ( μ O 2 OE∣El ) was investigated as a function of transport properties, electrolyte thickness and operating conditions (e.g., steam concentration, constant current, and constant voltage). Our analysis shows that: a lower ionic area specific resistance (ASR), r i O E , and a higher electronic ASR ( r e O E ) of the oxygen electrode/electrolyte interface are in favor of suppressing crack formation. The μ O 2 O E ∣ E l , thus local pO 2 , are sensitive towards the operating parameters under galvanostatic or potentiostatic electrolysis. Constant current density electrolysis provides better robustness, especially at a high current density with a high steam content. While constant voltage electrolysis leads to greater variations of μ O 2 O E ∣ E l . Constant current electrolysis, however, is not suitable for an unstable oxygen electrode because μ O 2 O E ∣ E l can reach a very high value with a gradually increased r i O E . A crack may only occur under certain conditions when p O 2 T P B > p c r .

42 ENGINEERING↗