At least 55 records · Page 3

The Optical Design of a System using a Fresnel Lens that Gathers Light for a Solar Concentrator and that Feeds into Solar Alignment Optics

The Marshall Space Flight Center (MSFC) has been developing a space deployable, lightweight membrane concentrator to focus solar energy into a solar furnace while remaining aligned to the sun. For an inner surface, this furnace has a cylindrical heat exchanger cavity coaligned to the optical axis; the furnace warms gas to propel the spacecraft. The membrane concentrator is a 1727 mm (68.00 in.) diameter, F/1.7 Fresnel lens. This large membrane is made from polyimide and is 0.076 mm (0.0030 in.) thick; it has the Fresnel grooves cast into it. The solar concentrator system has a super fast paraboloid reflector near the lens focus and immediately adjacent to the cylindrical exchanger cavity. The paraboloid collects the wide bandwidth and some of the solar energy scattered by the Fresnel lens. Finally, the paraboloid feeds the light into the cylinder. The Fresnel lens also possesses a narrow annular zone that focuses a reference beam toward four detectors that keep the optical system aligned to the sun; thus, occurs a refracting lens that focuses two places! The result can be summarized as a composite Fresnel lens for solar concentration and alignment.

Wilkerson, Gary W.↗

Optical alignments of the Cosmic Background Explorer (COBE) observatory

The angular alignments and stabilities of multiple components in a single coordinate system were determined using various alignment tooling techniques. These techniques use autocollimation measurements with a first order theodolite and transformation of coordinates to determine the relative alignment between various components with respect to a common set of COBE spacecraft coordinate axes. Optical-mechanical alignment techniques were also used to integrate the flight COBE observatory attitude control system module that consists of gyros, reaction wheels, and a momentum wheel. Particular attention is given to the techniques for alignments and stabilities of the earth scanners, sun sensors, far IR absolute spectrophotometer, Diffuse Infrared Background Experiment, and differential microwave radiometer antenna horn boresights.

Sampler, Henry P.↗

Neural nets for aligning optical components in harsh environments: Beam smoothing spatial filter as an example

The goal is to develop an approach to automating the alignment and adjustment of optical measurement, visualization, inspection, and control systems. Classical controls, expert systems, and neural networks are three approaches to automating the alignment of an optical system. Neural networks were chosen for this project and the judgements that led to this decision are presented. Neural networks were used to automate the alignment of the ubiquitous laser-beam-smoothing spatial filter. The results and future plans of the project are presented.

Decker, Arthur J.↗

Optical Alignment of the Chromospheric Lyman-Alpha SpectroPolarimeter using Sophisticated Methods to Minimize Activities under Vacuum

The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is a sounding-rocket instrument developed at the National Astronomical Observatory of Japan (NAOJ) as a part of an international collaboration. The in- strument main scientific goal is to achieve polarization measurement of the Lyman-alpha line at 121.56 nm emitted from the solar upper-chromosphere and transition region with an unprecedented 0.1% accuracy. For this purpose, the optics are composed of a Cassegrain telescope coated with a "cold mirror" coating optimized for UV reflection and a dual-channel spectrograph allowing for simultaneous observation of the two orthogonal states of polarization. Although the polarization sensitivity is the most important aspect of the instrument, the spatial and spectral resolutions of the instrument are also crucial to observe the chromospheric features and resolve the Ly- pro les. A precise alignment of the optics is required to ensure the resolutions, but experiments under vacuum conditions are needed since Ly-alpha is absorbed by air, making the alignment experiments difficult. To bypass this issue, we developed methods to align the telescope and the spectrograph separately in visible light. We will explain these methods and present the results for the optical alignment of the CLASP telescope and spectrograph. We will then discuss the combined performances of both parts to derive the expected resolutions of the instrument, and compare them with the flight observations performed on September 3rd 2015.

CLASP↗

Integrated Radio and Optical Communications (iROC) Primary, Secondary, and Tertiary Optics Alignment Procedure

This Technical Memorandum (TM) describes a procedure and associated equipment for performing an initial, relative alignment of a multiple-element optical system. The specific system of interest motivating this procedure arises from the Integrated Radio and Optical Communications (iROC) project, but is applicable to the more general configuration of a two-element folded, reflective telescope. Each step of the procedure includes a description of the particular degree of freedom (DOF) being addressed, and the associated equipment required, including both commercially available items and those fabricated specifically for this purpose.

Paul S Greenberg↗

Theoferometer for High Accuracy Optical Alignment and Metrology

The accurate measurement of the orientation of optical parts and systems is a pressing problem for upcoming space missions, such as stellar interferometers, requiring the knowledge and maintenance of positions to the sub-arcsecond level. Theodolites, the devices commonly used to make these measurements, cannot provide the needed level of accuracy. This paper describes the design, construction, and testing of an interferometer system to fill the widening gap between future requirements and current capabilities. A Twyman-Green interferometer mounted on a 2 degree of freedom rotation stage is able to obtain sub-arcsecond, gravity-referenced tilt measurements of a sample alignment cube. Dubbed a 'theoferometer,' this device offers greater ease-of-use, accuracy, and repeatability than conventional methods, making it a suitable 21st-century replacement for the theodolite.

Toland, Ronald↗

Training manual on optical alignment instruments

Training Manual RQA/M5 provides a basic course of instruction in the use of optical instruments for precise dimensional control and alignment of structural elements and assemblies, such as associated with space vehicles, aircraft, ships, and buildings.

Source record↗

Optical alignment of a pupil imaging spectrometer

The GOES Sounder is a 19-channel discrete filter spectrometer with an additional channel for star sensing. This paper presents the GOES Sounder's instrument optics and compensations, alignment rationale, and alignment mechanism and sensitivities. The results of a line of sight tolerance analysis of the instrument are described, and the prealignment and instrument coregistration are addressed.

Horchem, Stephen D.↗

Optical Alignment and Diffraction Analysis for AIRES: An Airborne Infrared Echelle Spectrometer

The optical design is presented for a long-slit grating spectrometer known as AIRES (Airborne InfraRed Echelle Spectrometer). The instrument employs two gratings in series: a small order sorter and a large steeply blazed echelle. The optical path includes four pupil and four field stops, including two narrow slits. A detailed diffraction analysis is performed using GLAD by Applied Optics Research to evaluate critical trade-offs between optical throughput, spectral resolution, and system weight and volume. The effects of slit width, slit length, oversizing the second slit relative to the first, on- vs off-axis throughput, and clipping at the pupil stops and other optical elements are discussed.

Haas, Michael R.↗

Thermal-vacuum testing and in-situ optical alignment measurements of the HALOE telescope/sun sensor assembly

Design features, test data and projected performance levels of the telescope/sun sensor assembly for the Halogen Occultation Experiment (HALOE) on board the Upper Atmosphere Research Satellite are described. HALOE will gather data on stratospheric chemical species with an IR telescope pointed through the atmosphere at the sun during occultation periods. The pointing accuracy will need to be 1 arcmin elevation and 1.6 arcmin azimuthal. Adjustments of the gimbaled instrument are guided by a sun sensor and its associated electronics. The components were subjected to thermal-vacuum, optical boresight stability tests and the data generated were compared with a finite element model of the telescope and sun sensor. The tests consisted of exposure to various thermal gradients while the telescope and sun sensor alignments were tracked by optical deflectometry. The thermal behavior was compared with predictions made with a finite difference model. Alignments were within tolerable ranges and the thermal behavior model was concluded valid for predicting the thermal behavior of orbiting instruments.

Foss, R. A.↗

Thermal and Mechanical Stability of the WF/PC II Optical Alignment

The Wide Field/Planetary Camera (WF/PC), developed by the Jet Propulsion Laboratory (JPL) under contract to the National Aeronautics and Space Administration (NASA), is the principal science instrument on the Hubble Space Telescope (HST). The analytical predicted motion of the WF/PC II optical elements showed that the four mechanisms added to the WF/PC II optical train will be able to maintain instrument alignment through the entire range of environmental changes from alignment on earth to operation in space.

Wide↗

Optical Alignment of the JWST ISIM to the OTE Simulator (OSIM): Current Concept and Design Studies

The James Webb Space Telescope's (JWST) Integrated Science Instrument Module (ISIM) contains the observatory's four science instruments and their support subsystems. During alignment and test of the integrated ISIM at NASA's Goddard Space Flight Center (GSFC), the Optical'telescope element SIMulator (OSIM) will be used to optically stimulate the science instruments to verify their operation and performance. In this paper we present the design of two cryogenic alignment fixtures that will be used to determine and verify the proper alignment of OSIM to ISIM during testing at GSFC. These fixtures, the Master Alignment Target Fixture (MAW) and the ISIM Alignment Target Fixture (IATF), will provide continuous, six degree of freedom feedback to OSIM during initial ambient alignment as well as during cryogenic vacuum testing. These fixtures will allow us to position the OSIM and maintain OSIM-ISIM alignment to better than 10 microns in translation and 250 micro-radians in rotation. We will provide a brief overview of the OSIM system and calibration and we will also discuss the relevance of these fixtures in the context of the overall ISIM alignment and verification plan.

Frey, Bradley J.↗

Systematic Image Based Optical Alignment and Tensegrity

This presentation will review the objectives and current status of two Small Business Innovative Research being performed by the Sirius Group, under the direction of MSFC. They all relate to the development of advanced optical systems technologies for automated segmented mirror alignment techniques and fundamental design methodologies for ultralight structures. These are important to future astronomical missions in space.

Zeiders, Glenn W.↗

Optical Alignment of the JWST ISIM to the OTE Simulator (OSIM): Current Concept and Design Studies

The James Webb Space Telescope's (JWST) Integrated Science Instrument Module (ISIM) is the scientific payload of the observatory and contai ns four science instruments. During alignment and test of the integrated ISIM (i.e. ISIM + science instruments) at NASA's Goddard Space Fli ght Center (GSFC), the Optical telescope element SIMulator (OSIM) wil l be used to optically stimulate the science instruments to verify their operation and performance. In this paper we present the design of two cryogenic alignment fixtures that will be used to determine and verify the proper alignment of OSIM to ISIM during testing at GSFC. The se fixtures, the Master Alignment Target Fixture (MATF) and the ISIM Alignment Target Fixture (IATF), will provide continuous, 6 degree of freedom feedback to OSIM during initial ambient alignment as well as during cryogenic vacuum testing.

Frey, Bradley J.↗

Optical alignment of Centaur's inertial guidance system

During Centaur launch operations the launch azimuth of the inertial platform's U-accelerometer input axis must be accurately established and maintained. This is accomplished by using an optically closed loop system with a long-range autotheodolite whose line of sight was established by a first-order survey. A collimated light beam from the autotheodolite intercepts a reflecting Porro prism mounted on the platform azimuth gimbal. Thus, any deviation of the Porro prism from its predetermined heading is optically detected by the autotheodolite. The error signal produced is used to torque the azimuth gimbal back to its required launch azimuth. The heading of the U-accelerometer input axis is therefore maintained automatically. Previously, the autotheodolite system could not distinguish between vehicle sway and rotational motion of the inertial platform unless at least three prisms were used. One prism was mounted on the inertial platform to maintain azimuth alignment, and two prisms were mounted externally on the vehicle to track sway. For example, the automatic azimuth-laying theodolite (AALT-SV-M2) on the Saturn vehilce used three prisms. The results of testing and modifying the AALT-SV-M2 autotheodolite to simultaneously monitor and maintain alignment of the inertial platform and track the sway of the vehicle from a single Porro prism.

Gordan, Andrew L.↗

Optical alignment of electrodes on electrical discharge machines

Shadowgraph system projects magnified image on screen so that alignment of small electrodes mounted on electrical discharge machines can be corrected and verified. Technique may be adapted to other machine tool equipment where physical contact cannot be made during inspection and access to tool limits conventional runout checking procedures.

Boissevain, A. G.↗

LEAPS (Laser electro-optical alignment pole for surveying)

Azimuthal bearing between two obscured points is measured by placing laser beam at one of the points. Beam is directed straight up into the air so that some part of it may be detected from any position a reasonable distance away.

Caudill, L.↗

Real-time Optical Alignment and Diagnostic System (ROADS)

The ultimate and most frequent usage of ROADS will be the alignment of subassemblies (collector and collimator) prior to their installation in a chamber. The system as designed has inherent associated capabilities well applied to acceptance testing of the No. 4 mirror, prediction of in-chamber performance, generation of a catalog of test results and other data, providing data for the plotting of isointensity lines, and other applications which are discussed. The ROADS system will collect, process, display, analyze, and retain data as required for components, partial subassemblies, complete subassemblies, complete modules, and multimodular arrays.