Engineering PapersSearch

SEARCH · Engineering Papers

Results for “onsite energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Electricity Rate Designs for Large Loads: Evolving Practices and Opportunities

Electricity demand from large load customers such as data centers is projected to grow significantly in the near term. While data centers play an important role in advancing technology innovation and economic growth in the United States, data center energy needs present challenges and opportunities for electricity supply and infrastructure. This technical brief serves as a foundation for the discussion of issues and sharing of perspectives among utilities, regulators, large load customers, and other stakeholders. As utilities and regulators explore rate structures to address growing data center electricity demand, several issues have emerged: -Fair allocation of electricity system costs to large-load customers without unfair shifting of costs to other customers -Appropriate mitigation of the financial risks associated with stranded assets from underutilized utility system investments -Mitigation of operational and resource adequacy risks if electricity demand exceeds supply -Appropriate risk-sharing in commercializing newer electricity technologies such as advanced geothermal, small modular reactors, and long duration energy storage -Accommodating the diverse needs of large-load customers, such as having the option to match electricity consumption with output from carbon-free resources or using onsite generation to provide system capacity The technical brief also identifies key design elements that aim to address these issues and uses leading examples from pending and approved rate structures, agreements, and special contracts to ground the elements in practice.

24 POWER TRANSMISSION AND DISTRIBUTION

Industrial Electrification Technologies Booklet

Electrification refers to transitioning from fuel-powered systems to electrically-powered alternatives. In an industrial context, this primarily refers to the electrification of process heat, but there are also widespread opportunities to electrify space heating and cooling as well as onsite transportation (e.g., forklifts). Electrification does not refer to one particular technology, but a wide range of technologies that use different methods to transfer electrical energy into a usable form – usually heat.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Evaluation of Technologies to Mitigate the Presence of Gaseous Elemental Mercury in Waste Disposal Containers

A study was conducted to evaluate sorbent technologies that can mitigate the presence of elemental mercury (Hg⁰) in waste containers for mercury-contaminated debris (MCD). Decontamination and demolition (D&D) activities at the Y-12 National Security Complex (Y-12) and other U.S. Department of Energy (DOE) Oak Ridge Reservation (ORR) facilities generate MCD requiring offsite disposal. The debris is packaged in appropriate waste containers and may be temporarily stored onsite prior to transport for treatment and/or disposal. During transportation of loads that had no visible liquid Hg at the point of origin, temperature changes can cause Hg⁰ to evaporate, condense, and form droplets on container walls. Furthermore, vibration during transportation could cause beads of Hg to be released from the debris, container walls, and ceiling, resulting in pools of liquid Hg⁰ on the container floor. Waste acceptance criteria (WAC) limitations for commercial disposal facilities, the Nevada National Security Site (NNSS), and ORR mixed low-level waste landfills prohibit the presence of any free liquids in containers identified as a solid waste form. Potential solutions to mitigate the presence of residual liquids that could be formed through vapor condensation include the use of sorbents or similar materials to capture and stabilize volatile Hg⁰ vapors and thus ensure compliance with landfill WAC requirements. This report summarizes data from small-scale laboratory experiments conducted to evaluate sorbent materials for Hg⁰ vapor suppression and sorption of liquid Hg⁰ that could form under relevant transportation and disposal conditions. A series of experiments was conducted to evaluate commercial sorbent materials and their effectiveness for Hg⁰ sorption across a temperature range from 19.4°C to 60°C. The impact of residual moisture on sorption was investigated under relevant conditions, and leaching tests were performed to assess the stability of Hg⁰ captured sorbent materials. The results provide estimates for sorbent quantities needed for a given Hg⁰ mass loading based on experimental results exposing sorbents to gaseous and liquid Hg⁰ at various mass ratios. Overall, sorbents that were most effective for Hg⁰ vapor suppression were brominated activated carbons, mackinawite-based sorbents coated on vermiculite, and sulfur-modified granular activated carbon. Elevated temperatures and moisture conditions did not result in significant increases of Hg⁰ headspace concentrations, and the materials also demonstrated high sorption capacities for the sorption of liquid Hg⁰.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

New Particle Formation Event Dataset at the Southern Great Plains (SGP) Observatory from 2018 to 2023

This data set contains observations of new particle formation (NPF) events collected at the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) observatory from 2018 to 2023. Measurements include particle number size distributions, radiance measurements, and associated meteorological variables from onsite instrumentation relevant for identifying and characterizing NPF events. Events were identified using standardized criteria and documented to support investigations of aerosol nucleation, growth dynamics, and their interactions with local atmospheric conditions. The data set provides a multi-year record that enables evaluation of seasonal and interannual variability in NPF occurrence and intensity at a mid-continental site. These data are intended to support studies of aerosol-cloud-climate interactions and model evaluation within both ARM and the broader atmospheric science community. More information can be found within the README_NPF_SGP_2018_2023.docx file.

event

Solar-heated bank-Marks Mississippi

Report describes air solar-energy collectors which supply 60 percent of space heating load for full-service bank. Contemporary structure supports 468 square feet of flat-plate arrays, and features onsite temperature and power measurement readouts. Air-flow collectors minimize problems experienced with conventional liquid solar equipment and eliminate need for heat exchanger for space heating.

Source record

Behind-the-Meter Energy Storage and Generation in Support of Electrified Rental Car Centers

Electrification of rental car centers at major airports is expected to generate tens of MW in additional power loads. The magnitude of these loads poses challenges including high utility costs, expensive and lengthy distribution capacity upgrades, and disruptions to traditional operation. Behind-the-meter stationary battery storage and onsite photovoltaic generation offer a viable solution to these challenges without impacting the operation and business model of rental car companies, defined by minimal fleet inventory and short vehicle dwell time. Using data-driven syn-thetic charging loads for the rental car center at the Dallas/Fort Worth airport in the United States, we show that optimally-designed and controlled behind - the- meter resources can reduce the lifecycle cost of electrified rental centers by an average 41 % and reduce peak grid demand by 64 %, deferring the need for distribution upgrades or potentially avoiding it altogether.

battery storage

Cost Effective Electrochromic Glazing Repositioning For Insulating Glass & Secondary Windows

This project addressed both technical and economic objectives toward significantly increasing the availability of ElectroChromic (EC) dynamic architectural glass at reduced cost. In contrast to the prevailing industry location of the EC device layer on the exterior light of an Insulating Glass (IG) unit, Project Objectives assessed the feasibility of a) repositioning the device layer midway between two IG panes to configure triple glazing, and b) independently framed to enable positioning to the building interior independent of the original glass configured as a dynamic secondary window. Parallel research complementing both EC-IG and EC-WinSert configurations addressed integral Photo Voltaic, and ceiling mounted “broadcast” power to circumvent the significant onsite electrical con tracting normally associated with the installation of commercial EC glazing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Grid Resilience Analysis on Geothermal District Heating and Cooling Implementation Alongside Four Existing Oil and Gas Wells in Tuttle, Oklahoma: Preprint

This study builds on the existing techno-economic and environmental life cycle assessments performed for a geothermal district heating and cooling system implementation in Tuttle Oklahoma with four existing oil and gas wells. Its resilience in meeting the peak annual heating and cooling loads of the district assuming a temporary disconnection from the electrical grid is assessed both qualitatively and quantitatively. Attributes of resilience and qualitative criteria established by Kolker et al. (2022) for geothermal district heating systems are applied to the proposed case to highlight its vulnerabilities. Results indicate that increasing the redundancy and diversity in the physical configuration of the distributional piping can considerably increase the system’s resilience. A quantitative assessment executed via the REopt tool predicts that the ancillary electricity required to power the geothermal system’s heating and cooling can be met by an onsite emergency diesel generator during times of grid outages for over 28 days.

district heating and cooling

Grid Resilience Analysis on Geothermal District Heating and Cooling Implementation Alongside Four Existing Oil and Gas Wells in Tuttle, Oklahoma

This study builds on the existing techno economic and environmental life cycle assessments performed for a geothermal district heating and cooling system implementation in Tuttle Oklahoma with four existing oil and gas wells. Its resilience in meeting the peak annual heating and cooling loads of the district assuming a temporary disconnection from the electrical grid is assessed both qualitatively and quantitatively. Attributes of resilience and qualitative criteria established by Kolker et al. (2022) for geothermal district heating systems are applied to the proposed case to highlight its vulnerabilities. Results indicate that increasing the redundancy and diversity in the physical configuration of the distributional piping can considerably increase the system's resilience. A quantitative assessment executed via the REopt tool predicts that the ancillary electricity required to power the geothermal system's heating and cooling can be met by an onsite emergency diesel generator during times of grid outages for over 28 days.

district heating and cooling

Autonomous Operations for Advanced Reactors Utilizing Supervisory Control

Automation is a critical tenet of reactor plant operations as reliance on nuclear energy increases. Nuclear power plants require a large workforce which does not scale with output; that is, the cost per megawatt increases as reactor output becomes smaller. The economic viability of advanced reactors, particularly small modular reactors (SMRs) and microreactors, requires a significantly reduced onsite workforce. The logical solution is establishing a systematic process of elimination of reliance on human operators, and to the extent possible, replacing these actions with automated functions. In this paper, we propose a method for such transformation to establish a robust technical basis to enable transition to autonomy. Our method is based on finite state automata (FSA)—also known as finite state machines (FSMs). Relying on this method allows us to exploit the rich set of mathematical proofs available in the field of regular languages. FSA are one of the mathematical tools to model discrete event systems (DES). These properties are applied to produce an automated startup controller for the Massachusetts Institute of Technology Research Reactor (MITR). The startup procedure is captured in terms of discrete changes from one state to another while an independent supervisory control system directs the sequence of states and alerts a human in the event of an abnormal operation. First, the design and behavior of the MITR rod control system were modeled in Simulink. Then, the startup procedure was applied to the rod control system and the DES performed a startup by procedurally withdrawing rods to the subcritical position. The simulation also stops rod motion in response to an uncontrollable event and restarts rod motion once the event has been cleared.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN

Oscillate and renormalize: Fast phonons reshape the Kondo effect in flat-band systems

Here, we examine the interplay between electron correlations and phonons in an Anderson-Holstein impurity model with an Einstein phonon. When the phonons are slow compared to charge fluctuations (frequency 𝜔 0 ≪ 𝑈/2, the onsite Coulomb scale 𝑈/2), we demonstrate analytically that the expected phonon-mediated reduction of interactions is completely suppressed, even in the strong-coupling regime. This suppression arises from the oscillator's inability to respond to rapid charge fluctuations, manifested as a compensation effect between the polaronic cloud and the excited-state phonons associated with valence fluctuations. We identify a frozen mixed valence phase, above a threshold dimensionless electron-phonon coupling 𝛼* when the phonons are slow, where the static phonon cloud locks the impurity into specific valence configurations, potentially explaining the puzzling coexistence of mixed valence behavior and insulating properties in materials like rust. Conversely, when the phonon is fast (𝜔 0 ≳ 𝑈/2), the system exhibits conventional polaronic behavior with renormalized onsite interactions effectively 𝑈 eff due to phonon-mediated attraction, with additional satellite features in the local spectral function due to phonon excitations. Using numerical renormalization group calculations, a fully dynamic renormalization technique, we confirm these behaviors in both regimes. These findings have important implications for strongly correlated systems where phonon energy scales may be comparable to the Coulomb scale, such as in twisted bilayer graphene, necessitating careful consideration of interaction renormalizations in theoretical models.

Anderson impurity model

Memorial Pools Energy Efficiency Retrofits

The National September 11 Memorial & Museum completed a retrofit of the submergible LED lighting fixtures in its North and South Memorial Pools, located at the World Trade Center site in New York City. The two one-acre pools are illuminated nightly by custom LED fixtures set into their base, and the original lights — in place since 2011 — had begun reaching the end of their useful life, leaving sections of the pools dim or dark. Rather than fully replacing the fixtures, the project team worked with the original manufacturer, Acuity Brands, to retrofit and reuse existing components across all eight pool walls (34 fixtures per wall), reducing cost and waste. Fixtures were shipped in custom crates to Minnesota for retrofitting, then reinstalled onsite by Memorial & Museum staff and contractor ABM. The team addressed two key technical challenges during the project: early leakage in retrofitted fixtures, resolved by introducing vacuum-sealing and nitrogen-fill testing before shipment; and chord damage during transit, resolved with custom-designed shipping crates. All eight pool walls were successfully retrofitted and reinstalled by August 27, 2025, ahead of the 25th anniversary of the September 11, 2001 attacks. Sitewide electrical consumption in September 2025 reflected an approximate 7% reduction, contributing to the institution's broader net-zero and LEED Gold sustainability goals.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Targeted Mobile Measurements to Isolate the Impacts of Aerosols and Meteorology on Deep Convection

One of the main goals of the Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Tracking Aerosol Convection Interactions Experiment (TRACER) field campaign near Houston, TX was to improve understanding of meteorology and aerosol effects on deep convective storms. To help TRACER achieve its goals of disentangling aerosol-cloud interactions from meteorology, the Texas A&M University (TAMU) team deployed the new fully mobile Rapid Onsite Atmospheric Measurement Van (ROAM-V) carrying instruments to measure aerosol and atmospheric properties that was moved to multiple locations on a deployment day of isolated convection initiated by the sea breeze.

54 ENVIRONMENTAL SCIENCES

EMP - Environmental Radiological Air Monitoring Plan: PNNL Operations in Washington

The Environmental Radiological Air Monitoring Plan (EMP) for Pacific Northwest National Laboratory (PNNL) describes systems/processes/practices related to radiological operations in Richland and Sequim, Washington, that are associated with environmental radiological air monitoring and surveillance activities. The activities described support the lab’s responsibility to maintain safe operations and minimize negative impacts to both onsite and offsite persons and environment. Dose assessments required by regulations and DOE Orders for the public and biota are described. PNNL conducts environmental air surveillance monitoring as part of the PNNL Site Radioactive Air Emissions License (RAEL)-005 for Richland Campus, issued in 2010 with its most recent renewal effective in January 2021. The radioactive air emissions license for the PNNL-Sequim campus (RAEL-014) was issued to the U.S. Department of Energy in 2012 with its most recent renewal effective in January 2023. The EMP is a compilation of the following four documents: - Environmental Radiological Air Monitoring Plan (this main document) (PNNL-20919) - Sampling and Analysis Plan (Attachment 1) (PNNL-20919-1) - Data Management Plan (Attachment 2) (PNNL-20919-2) - Dose Assessment Guidance (Attachment 3) (PNNL-20919-3).

40 CFR 61 Subpart H

Renewable Hydrogen to Vehicle (RH2V) – Operation Verification and Risk Mitigation Studies: Original Agreement (Modification 0) (CRADA Final Report)

Toyota has announced plans for commercial fuel cell vehicle deployment in 2015. To fully realize the benefits of fuel cell vehicles (zero emission with no performance loss in terms of vehicle range and capability), hydrogen produced efficiently from renewable sources is necessary. Most of the hydrogen fueling stations today utilize hydrogen reformed from natural gas (produced onsite or delivered). This enables more stations to be deployed cost-effectively within a network. Producing and using cost-effective renewable hydrogen in fuel cell vehicles will enable realization of the full potential. A viable option of green hydrogen that reliably delivers on the full suite of benefits for Toyota fuel cell vehicle drivers is needed. NREL is in a unique position to analyze and optimize renewable hydrogen production scenarios using the Energy Systems Integration Facility (ESIF), a facility that is specifically designed to evaluate renewable energy integration technologies. As the U.S. Department of Energy's (DOE) primary national laboratory for renewable energy and energy efficiency research and development, NREL has extensive knowledge of photovoltaic systems as well as alternative renewable technologies for efficient and reliable production of green hydrogen.

08 HYDROGEN

Princeton Plasma Physics Laboratory Annual Site Environmental Report for Calendar Year 2024

This report provides the US Department of Energy (DOE) and the public with information on the level of radioactive and non-radioactive pollutants (if any) that are added to the environment as a result of Princeton Plasma Physics Laboratory’s (PPPL) operations. This report fulfills the annual public reporting requirements of DOE Order 231.1B. The results of PPPL’s 2024 environmental surveillance and monitoring program are presented and discussed. The report also summarizes environmental initiatives, assessments, and community involvement programs that were undertaken in 2024. PPPL has engaged in fusion energy research since 1951 and at its current locations since 1958. The Laboratory’s mission is to develop the scientific knowledge and advanced engineering to enable fusion to power the US and the world, and to develop the understanding of plasmas from the nano- to the astrophysical scale. PPPL’s primary experiment, the National Spherical Torus Experiment-Upgrade (NSTX-U) is a collaboration among national laboratories, universities, and national and international research institutions and is a major element in the US Fusion Energy Sciences Program. Its design tests the physics principles of spherical torus (ST) plasmas, playing an important role in the development of smaller, more economical fusion reactors. Due to previous operational issues, NSTX-U did not operate in 2024. PPPL is engaged in a project to replace key NSTX-U components and systems to enable the operation of this international magnetic fusion user facility. In 2024, PPPL’s radiological environmental monitoring program measured tritium in the air at onsite sampling stations. Using highly sensitive air monitors, PPPL is capable of detecting small changes in the ambient levels of tritium. The operation of monitors located on D-site is used to demonstrate compliance with the National Emission Standard for Hazardous Air Pollutants (NESHAPs) regulations. Also included in PPPL’s radiological environmental monitoring program, are water monitoring – ground, surface, and waste waters. PPPL’s radiological monitoring program characterized the background levels of tritium in the environment and those data are presented in this report. Ground water monitoring continued under New Jersey Department of Environmental Protection’s (NJDEP) Site Remediation Program regulations. PPPL monitored for nonradiological contaminants, mainly volatile organic compounds (components of common degreasing solvents). In 2024, PPPL complied with permit limits for surface water and sanitary wastewater discharges. PPPL was honored with an award for EPEAT-certified electronics purchasing from the Global Electronics Council on July 25, 2024.

54 ENVIRONMENTAL SCIENCES

Annual Site Environment Report for Calendar Year 2023 - Princeton Plasma Physics Laboratory

This report provides the US Department of Energy (DOE) and the public with information on the level of radioactive and non-radioactive pollutants (if any) that are added to the environment as a result of Princeton Plasma Physics Laboratory’s (PPPL) operations. This report fulfills the annual public reporting requirements of DOE Order 231.1B. The results of PPPL’s 2023 environmental surveillance and monitoring program are presented and discussed. The report also summarizes environmental initiatives, assessments, and community involvement programs that were undertaken in 2023. This report provides the US Department of Energy (DOE) and the public with information on the level of radioactive and non-radioactive pollutants (if any) that are added to the environment as a result of Princeton Plasma Physics Laboratory’s (PPPL) operations. This report fulfills the annual public reporting requirements of DOE Order 231.1B. The results of PPPL’s 2023 environmental surveillance and monitoring program are presented and discussed. The report also summarizes environmental initiatives, assessments, and community involvement programs that were undertaken in 2023. In 2023, PPPL’s radiological environmental monitoring program measured tritium in the air at onsite sampling stations. Using highly sensitive air monitors, PPPL is capable of detecting small changes in the ambient levels of tritium. The operation of monitors located on D-site is used to demonstrate compliance with the National Emission Standard for Hazardous Air Pollutants (NESHAPs) regulations. Also included in PPPL’s radiological environmental monitoring program, are water monitoring – ground, surface, and waste waters. PPPL’s radiological monitoring program characterized the background levels of tritium in the environment and those data are presented in this report. Ground water monitoring continued under New Jersey Department of Environmental Protection’s (NJDEP) Site Remediation Program regulations. PPPL monitored for non-radiological contaminants, mainly volatile organic compounds (components of common degreasing solvents). In 2023, PPPL complied with permit limits for surface water and sanitary wastewater discharges. PPPL was honored with an award for EPEAT-certified electronics purchasing from the Global Electronics Council on July 27, 2023.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Techno-Economic Analysis of Green Hydrogen Energy Storage in a Cryogenic Flux Capacitor

Abstract The Cryogenic Flux Capacitor (CFC) is a cold, dense energy storage core that is being studied in the cryo-compressed, about 300 bar and 80K, region of gaseous hydrogen (GH2) storage and liquid hydrogen (LH2) region near the normal boiling point. Hydrogen storage is improved by physically bonding the molecules within the nanoscale pores of the aerogel composite blanket material. The process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (∼1,000 m2/g) allows its storage performance to easily exceed capacities of high-pressure GH2 storage for an equivalent volume. With the integrated aerogel, subscale tests have shown that storage is increased by about 36% over a simple tank filled with GH2 at the same operating temperature and pressure. For LH2 conditions, the CFC is shown to operate at improved densities, but testing is ongoing. For the techno-economic analysis (TEA), the source of hydrogen is compared between onsite steam methane reforming (SMR) and onsite solar photovoltaic (PV) panels providing power to electrolyzers to produce green GH2. The TEA compares pure hydrogen produced at a small scale for a 25 MW power system and at a large scale in a 500 MW power system. The system allowed for hydrogen imports and exports at a set price with a tank sized for 10 hours of power production. The two power producing technologies are a combined cycle gas turbine (CCGT) and hydrogen fuel cells. The SMR system uses natural gas as an input and includes a carbon capture and storage (CCS) system. The levelized cost of electricity (LCOE), levelized cost of hydrogen (LCOH), and levelized cost of storage (LCOS) are developed based on the capital cost and operating cost of the systems. The results are shown for current costs using a 2021 benchmark and DOE projections for cost improvements by 2030. The TEA showed that onsite hydrogen generation from SMR has an LCOH of about 1.4 to 2 USD per kg over the life of the plant and the PV hydrogen production LCOH is about 5.2 to 5.5 USD per kg. The LCOS of conventional GH2 systems is estimated to be $210/MWh and cost of storage for LH2 systems is $205/MWh for fuel cell systems and $249/MWh for CCGT systems. CFC improved the LCOS of all these systems to $198/MWh, $191/MWh and $233/MWh respectively. The LCOE also improved with conventional systems between $171/MWh and $228/MWh improved by CFC to between $167/MWh and $212/MWh. Using projections for improvement in costs following DOE’s goals by 2030, green hydrogen improved to as low as $78/MWh LCOS and LCOE for conventional cases. CFC improved over conventional storage with the lowest LCOS being $62/MWh and the lowest LCOE being $73/MWh. These results correspond to an LCOH of $2/kg. Finally, the TEA shows how LCOE is improved for hydrogen conditioning and storage over conventional systems and caverns in the 10 to 50 hour range.

08 HYDROGEN