Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nonequilibrium dynamics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Aerodynamics of the Mars Microprobe Entry Vehicles

The selection of the unique aeroshell shape for the Mars Microprobes is discussed. A description of its aerodynamics in hypersonic rarefied, hypersonic continuum, supersonic and transonic flow regimes is then presented. This description is based on Direct Simulation Monte Carlo analyses in the rarefied-flow regime, thermochemical nonequilibrium Computational Fluid Dynamics in the hypersonic regime, existing wind tunnel data in the supersonic and transonic regime, additional computational work in the transonic regime, and finally, ballistic range data. The aeroshell is shown to possess the correct combination of aerodynamic stability and drag to convert the probe's initial tumbling attitude and high velocity at atmospheric-interface into the desired surface-impact orientation and velocity.

Mitcheltree, R. A.↗

Computation of thermochemical nonequilibrium flows around a simple and a double ellipse

The nonequilibrium viscous reactive flows over a simple and a double ellipse at a 30 degree angle of attack were computed. The geometry and the free stream conditions are given by INRIA/GAMNI/SMAI workshop test cases 6.2-2 and 6.2-4. The governing Navier-Stokes equations coupled with thermochemical nonequilibrium processes are solved numerically using a fully coupled, implicit, finite volume technique with a dynamically adaptive grid. The nonequilibrium gas model and the numerical method used in the calculations are briefly described.

Gokcen, Tahir↗

Computation of thermochemical nonequilibrium flows around a simple and a double ellipse

The nonequilibrium viscous reactive flows over a simple and a double ellipse at a 30 degree angle of attack were computed. The geometry and the free stream conditions are given by INRIA/GAMNI/SMAI workshop test cases 6.2-2 and 6.2-4. The governing Navier-Stokes equations coupled with thermochemical nonequilibrium processes are solved numerically using a fully coupled, implicit, finite volume technique with a dynamically adaptive grid. The nonequilibrium gas model and the numerical method used in the calculations are briefly described.

Gokcen, Tahir↗

Determination of the Accommodation Coefficient Using Vapor/gas Bubble Dynamics in an Acoustic Field

Nonequilibrium liquid/vapor phase transformations can occur in superheated or subcooled liquids in fast processes such as in evaporation in a vacuum. The rate at which such a phase transformation occurs depends on the "condensation" or "accommodation" coefficient, Beta, which is a property of the interface. Existing measurement techniques for Beta are complex and expensive. The development of a relatively inexpensive and reliable technique for measurement of Beta for a wide range of substances and temperatures is of great practical importance. The dynamics of a bubble in an acoustic field strongly depends on the value of Beta. It is known that near the saturation temperature, small vapor bubbles grow under the action of an acoustic field due to "rectified heat transfer." This finding can be used as the basis for an effective measurement technique of Beta. We developed a theory of vapor bubble behavior in an isotropic acoustic wave and in a plane standing acoustic wave. A numerical code was developed which enables simulation of a variety of experimental situations and accurately takes into account slowly evolving temperature. A parametric study showed that the measurement of Beta can be made over a broad range of frequencies and bubble sizes. We found several interesting regimes and conditions which can be efficiently used for measurements of Beta. Measurements of Beta can be performed in both reduced and normal gravity environments.

Gumerov, Nail A.↗

Theoretical and experimental studies of reentry plasmas

A viscous shock-layer analysis was developed and used to calculate nonequilibrium-flow species distributions in the plasma layer of the RAM vehicle. The theoretical electron-density results obtained are in good agreement with those measured in flight. A circular-aperture flush-mounted antenna was used to obtain a comparison between theoretical and experimental antenna admittance in the presence of ionized boundary layers of low collision frequency. The electron-temperature and electron-density distributions in the boundary layer were independently measured. The antenna admittance was measured using a four-probe microwave reflectometer and these measured values were found to be in good agreement with those predicted. Measurements were also performed with another type of circular-aperture antenna and good agreement was obtained between the calculations and the experimental results. A theoretical analysis has been completed which permits calculation of the nonequilibrium, viscous shock-layer flow field for a sphere-cone body. Results are presented for two different bodies at several different altitudes illustrating the influences of bluntness and chemical nonequilibrium on several gas dynamic parameters of interest. Plane-wave transmission coefficients were calculated for an approximate space-shuttle body using a typical trajectory.

Dunn, M. G.↗

Effects of plasma microfields on radiative transitions from atomic levels above the ionization threshold

The effects of plasma electric microfields on line-like optical features arising from atomic levels above the ionization threshold are investigated within the framework of the quasi-static and single-frequency dynamic-field theories of spectral-line broadening. The 2p(23)P to 1s2p(3)P and 2s2p(3)P to 1s2s(3)S transitions in helium and helium-like ions are treated as examples. The mixing of the doubly excited levels in the perturbing microfields produces Stark broadening of the emission lines and induces autoionization of the 2p(23)P level, which, unlike the 2s2p(3)P level, is metastable against autoionization in the field-free environment. Determination of the complete Stark-broadening profiles in thermal plasmas is complicated by the need to include the effects of both the (quasi-static) ion and the (dynamic) electron fields. Under nonequilibrium conditions, where electric fields from either electron or ion plasma waves can far exceed nearby particle fields, the calculation and interpretation of the line shapes may be simplified and could provide a diagnostic probe of the wave-field properties.

Davis, J.↗

Flow Characterization Studies of the 10-MW TP3 Arc-Jet Facility: Probe Sweeps

This paper reports computational simulations and analysis in support of calibration and flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted in the NASA Ames 10-MW TP3 facility using flat-faced stagnation calorimeters at six conditions corresponding to the steps of a simulated flight heating profile. Data were obtained using a conical nozzle test configuration in which the models were placed in a free jet downstream of the nozzle. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were also performed at these arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. Two different sets of pitot pressure and heat probes were used: 9.1-mm sphere-cone probes (nose radius of 4.57 mm or 0.18 in) with null-point heat flux gages, and 15.9-mm (0.625 in) diameter hemisphere probes with Gardon gages. The probe survey data clearly show that the test flow in the TP3 facility is not uniform at most conditions (not even axisymmetric at some conditions), and the extent of non-uniformity is highly dependent on various arc-jet parameters such as arc current, mass flow rate, and the amount of cold-gas injection at the arc-heater plenum. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. Comparisons of computations with the experimental measurements show reasonably good agreement except at the extreme low pressure conditions of the facility envelope.

Goekcen, Tahir↗

Flow Characterization Studies of the 10-MW TP3 Arc-Jet Facility: Probe Sweeps

This paper reports computational simulations and analysis in support of calibration and flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted in the NASA Ames 10-MW TP3 facility using flat-faced stagnation calorimeters at six conditions corresponding to the steps of a simulated flight heating profile. Data were obtained using a conical nozzle test configuration in which the models were placed in a free jet downstream of the nozzle. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were also performed at these arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. Two different sets of pitot pressure and heat probes were used: 9.1-mm sphere-cone probes (nose radius of 4.57 mm or 0.18 in) with null-point heat flux gages, and 15.9-mm (0.625 in) diameter hemisphere probes with Gardon gages. The probe survey data clearly show that the test flow in the TP3 facility is not uniform at most conditions (not even axisymmetric at some conditions), and the extent of non-uniformity is highly dependent on various arc-jet parameters such as arc current, mass flow rate, and the amount of cold-gas injection at the arc-heater plenum. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. Comparisons of computations with the experimental measurements show reasonably good agreement except at the extreme low pressure conditions of the facility envelope.

CFD↗

Computational Simulations of the 10-MW TP3 Arc-Jet Facility Flow

This paper reports computational simulations and analysis in support of calibration tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted using stagnation calorimeters and two different blunted wedge models with calibration plates at a wide range of conditions in the NASA Ames 10-megawatt TP3 (Test Position 3) facility. Data were obtained using four different conical nozzles with the same test configuration in which the models were placed in a free jet downstream of the nozzle. Experimental surveys of arc-jet test flow with pitot and null-point heat flux probes were also performed at several arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested, and comparisons with the experimental measurements. These computational simulations provide estimates of the arc-jet test environment parameters that are not measured but are needed to evaluate the performance of thermal protection system materials, along with further valuable insights into the arc-jet testing environment. Simulation results are used to estimate centerline total enthalpy, surface shear, boundary layer thickness, and boundary layer edge Mach number and to verify that specific test requirements from the Orion program are met.

CFD↗

CFD Simulations of the IHF Arc-Jet Flow: 9-Inch Nozzle, Flow Surveys, LEAF Wedge Calibration Data

This paper reports computational analyses and flow characterization studies in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted using a wedge model placed in a free jet downstream of new 9-inch diameter conical nozzle in the Ames 60-MW Interaction Heating Facility. Both the nozzle and wedge model were specifically designed for testing in the new Laser-Enhanced Arc-jet Facility. Data were obtained using stagnation calorimeters and wedge models placed downstream of the nozzle exit. Two instrumented wedge calibration plates were used: one water-cooled and the other RCG-coated tile plate. Experimental surveys of arc-jet test flow with pitot and heat flux probes were also performed at three arc-heater conditions, providing assessment of the flow uniformity and valuable data for the flow characterization. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested, and comparisons with the experimental measurements. By taking into account nonuniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields, these simulations approximately reproduce the probe survey data and predict the wedge model surface pressure and heat flux measurements.

Arc-jets↗

CFD Simulations of the IHF 13-Inch Nozzle Flow: 55-deg Sphere-Cone Model, Manufactured Fences and Gaps

This paper reports computational analyses of testsin a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted using 55-deg sphere-cone models placed in a free jet downstream of the 13-inch diameter conical nozzle in the Ames 60-MW Interaction Heating Facility. Some of the sphere-cone models include surface features such as manufactured fences and gaps intended to simulate effects of differential recession, all of which disturb the flow, producing augmented heating locally and downstream.Test calibration data were obtained using slug and Gardon gage stagnation calorimeters, and a sphere-cone calorimeter model with six Gardon gages and five pressure tabs.The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested, and comparisons with the experimental measurements. These simulations take into account nonuniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields.

Arc-jets↗

Analysis of Probe Surveys Conducted in the 10-MW TP3 Arc-Jet Facility 15-Inch Nozzle Flow

Computational simulations and analysis of flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center are reported. These tests were conducted in the 10-MW TP3 facility 15-inch conical nozzle, and pitot pressure and heat flux probes are used to survey test flow downstream of the nozzle exit. Two 1.59-cm (0.625 in) diameter hemisphere probes were used: one with a stagnation-point pressure port, the other with a Gardon heat flux gage. Calibration data were also obtained using 10.16-cm iso-q and 20.32-cm flat-faced slug calorimeters. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were obtained at eight arc-heater conditions, covering wide ranges in arc current (316–1756 A) and mass flow rate (32–500 g/s, without any cold-gas injection at the arc-heater plenum) and providing assessment of the flow uniformity in the facility. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. These simulations take into account non-uniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields. Comparisons of computations with the experimental measurements are presented, showing reasonably good agreement. The probe survey data and accompanying analysis show that the test flow in the TP3 15-inch nozzle is highly non-uniform at most conditions, and the extent of flow non-uniformity depends on arc current and mass flow rate.

Arc-jets↗

CFD Simulations of the Truncated IHF Semi-Elliptical Nozzle Flow: Convective Calibration Plate

This paper reports computational simulations of a high-enthalpy panel test facility at NASA Ames Research Center. The recently developed facility configuration uses a truncated version of an existing semi-elliptical nozzle in the 60-MW Interaction Heating Facility, and it provides testing capability for panel test articles as large as 43.2 cm x 43.2 cm (17 in x 17 in). A water-cooled calibration plate, which is attached to the semi-elliptical nozzle bottom surface and instrumented with twenty Gardon-gage heat flux calorimeters and twelve pressure gages, is used to characterize the convective heating environment over the panel test articles. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, and flowfield over panel test articles. Both laminar and turbulent simulations are performed, and the computational results are compared with the calibration plate measurements. Comparisons of computed and measured heat fluxes indicate that the boundary layer in the semi-elliptical nozzle is transitional at certain conditions (relatively higher arc-heater pressures or mass flow rates).

Arc-jets↗

Analysis of Probe Surveys Conducted in the 10-MW TP3 Arc-Jet Facility 15-Inch Nozzle Flow

Computational simulations and analysis of flow characterization tests in a high enthalpy arc-jet facility at NASA Ames Research Center are reported. These tests were conducted in the 10-MW TP3 facility 15-inch conical nozzle, and pitot pressure and heat flux probes are used to survey test flow downstream of the nozzle exit. Two 1.59-cm (0.625 in) diameter hemisphere probes were used: one with a stagnation-point pressure port, the other with a Gardon heat flux gage. Calibration data were also obtained using 20.32-cm flat-faced slug calorimeters. Experimental surveys of arc-jet test flow with pitot pressure and heat flux probes were obtained at eight arc-heater conditions, covering wide ranges in arc current (316–1756 A) and mass flow rate (32–500 g/s, without any cold-gas injection at the arc-heater plenum) and providing assessment of the flow uniformity in the facility. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested. These simulations take into account non-uniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields. Comparisons of computations with the experimental measurements are presented, showing reasonably good agreement. The probe survey data and accompanying analysis show that the test flow in the TP3 15-inch nozzle is highly non-uniform at most conditions, and the extent of flow non-uniformity depends on arc current and mass flow rate.

Arc-jets↗

CFD Simulations of the Truncated IHF Semi-Elliptical Nozzle Flow: Convective Calibration Plate

This paper reports computational simulations of a high-enthalpy panel test facility at NASA Ames Research Center. The recently developed facility configuration uses a truncated version of an existing semi-elliptical nozzle in the 60-MW Interaction Heating Facility, and it provides testing capability for panel test articles as large as 43.2 cm x 43.2 cm (17 in x 17 in). A water-cooled calibration plate, which is attached to the semi-elliptical nozzle bottom surface and instrumented with twenty Gardon-gage heat flux calorimeters and twelve pressure gages, is used to characterize the convective heating environment over the panel test articles. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, and the flowfields over panel test articles. Both laminar and turbulent simulations are performed, and the computational results are compared with the calibration plate measurements. Comparisons of computed and measured heat fluxes indicate that the boundary layer in the semi-elliptical nozzle is transitional at certain conditions (relatively higher arc-heater pressures or mass flow rates).

Arc-jets↗

On Characterization of Laminar to Turbulent Transitional Flow in the Truncated IHF Semi-Elliptical Nozzle

This paper reports computational analysis and experimental data to characterize the laminar to turbulent flow transition in a high-enthalpy panel test facility at NASA Ames Research Center. The recently developed facility configuration uses a truncated version of an existing semi-elliptical nozzle in the 60-MW Interaction Heating Facility, and it provides testing capability for panel test articles as large as 43.2 cm x 43.2 cm (17 in x 17 in). A water-cooled calibration plate, which is attached to the semi-elliptical nozzle bottom surface and instrumented with twenty Gardon-gage heat flux calorimeters and twelve pressure gages, is used to characterize the convective heating environment over the panel test articles. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, and the flowfields over panel test articles, and comparisons with the measured test data. Both laminar and turbulent simulations are performed. Constant current studies are performed: the measured data are grouped at the same arc current levels with varying mass flow rates, and they are compared with corresponding computations. For all currents studied, these studies indicate that the semi-elliptical nozzle flow is transitional at relatively higher mass flow rates within the facility operating envelope.

Arc-jets↗

CFD Simulations of the IHF 13-Inch Nozzle Flow: 55-deg Sphere-Cone Model, Manufactured Fences and Gaps

This paper reports computational analyses of tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted using 55-deg sphere-cone models placed in a free jet downstream of the 13-inch diameter conical nozzle in the Ames 60-MW Interaction Heating Facility. Some of the sphere-cone models include surface features such as manufactured fences and gaps intended to simulate effects of differential recession, all of which disturb the flow, producing augmented heating locally and downstream. Test calibration data were obtained using slug and Gardon gage stagnation calorimeters, and a sphere-cone calorimeter model with six Gardon gages and five pressure tabs. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested, and comparisons with the experimental measurements. These simulations take into account nonuniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields.

Arc-jets↗