Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “noise diodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The Aquarius Salinity Retrieval Algorithm: Early Results

The Aquarius L-band radiometer/scatterometer system is designed to provide monthly salinity maps at 150 km spatial scale to a 0.2 psu accuracy. The sensor was launched on June 10, 2011, aboard the Argentine CONAE SAC-D spacecraft. The L-band radiometers and the scatterometer have been taking science data observations since August 25, 2011. The first part of this presentation gives an overview over the Aquarius salinity retrieval algorithm. The instrument calibration converts Aquarius radiometer counts into antenna temperatures (TA). The salinity retrieval algorithm converts those TA into brightness temperatures (TB) at a flat ocean surface. As a first step, contributions arising from the intrusion of solar, lunar and galactic radiation are subtracted. The antenna pattern correction (APC) removes the effects of cross-polarization contamination and spillover. The Aquarius radiometer measures the 3rd Stokes parameter in addition to vertical (v) and horizontal (h) polarizations, which allows for an easy removal of ionospheric Faraday rotation. The atmospheric absorption at L-band is almost entirely due to O2, which can be calculated based on auxiliary input fields from numerical weather prediction models and then successively removed from the TB. The final step in the TA to TB conversion is the correction for the roughness of the sea surface due to wind. This is based on the radar backscatter measurements by the scatterometer. The TB of the flat ocean surface can now be matched to a salinity value using a surface emission model that is based on a model for the dielectric constant of sea water and an auxiliary field for the sea surface temperature. In the current processing (as of writing this abstract) only v-pol TB are used for this last process and NCEP winds are used for the roughness correction. Before the salinity algorithm can be operationally implemented and its accuracy assessed by comparing versus in situ measurements, an extensive calibration and validation (cal/val) activity needs to be completed. This is necessary in order to tune the inputs to the algorithm and remove biases that arise due to the instrument calibration, foremost the values of the noise diode injection temperatures and the losses that occur in the feedhorns. This is the subject of the second part of our presentation. The basic tool is to analyze the observed difference between the Aquarius measured TA and an expected TA that is computed from a reference salinity field. It is also necessary to derive a relation between the scatterometer backscatter measurements and the radiometer emissivity that is induced by surface winds. In order to do this we collocate Aquarius radiometer and scatterometer measurements with wind speed retrievals from the WindSat and SSMIS F17 microwave radiometers. Both of these satellites fly in orbits that have the same equatorial ascending crossing time (6 pm) as the Aquarius/SAC-D observatory. Rain retrievals from WindSat and SSMIS F 17 can be used to remove Aquarius observations that are rain contaminated. A byproduct of this analysis is a prediction for the wind-induced sea surface emissivity at L-band.

Meissner, Thomas↗

Calibration of Hurricane Imaging Radiometer C-Band Receivers

The laboratory calibration of airborne Hurricane Imaging Radiometer's C-Band multi-frequency receivers is described here. The method used to obtain the values of receiver frontend loss, internal cold load brightness temperature and injected noise diode temperature is presented along with the expected RMS uncertainty in the final calibration.

HURRICANE IMAGING RADIOMETER↗

Design of a Combined Beacon Receiver and Digital Radiometer for 40 GHz Propagation Measurements at the Madrid Deep Space Communications Complex

NASA Glenn Research Center (GRC) and the Jet Propulsion Laboratory (JPL) have jointly developed an atmospheric propagation terminal to measure and characterize propagation phenomena at 40 GHz at the Madrid Deep Space Communications Complex (MDSCC) in Robledo de Chavela, Spain. The hybrid Q-band system utilizes a novel design which combines a 40 GHz beacon receiver and digital radiometer into the same RF front-end and observes the 39.402 GHz beacon of the European Space Agencys Alphasat Aldo Paraboni TDP5 experiment. Atmospheric measurements include gaseous absorption, rain fade, and scintillation. The radiometric measurement is calibrated by means of an included noise diode as well as tipping calibration. The goals of these measurements are to assist MDSCC mission operations as the facility increasingly supports Ka-band missions, as well as to contribute to the development and improvement of International Telecommunications Union (ITU) models for prediction of communications systems performance within the Q-band through the Aldo Paraboni Experiment. Herein, we provide an overview of the system design, characterization, and plan of operations which commenced at the MDSCC beginning in March 2017.

Radiowave Propagation↗

Soil Moisture Active/Passive (SMAP) L-Band Microwave Radiometer Post-Launch Calibration Upgrade

Current performance and existing problems in SMAP radiometer L1B_TB version 3 data product are described. The post-launch calibration algorithm has been updated by calibrating the three calibration parameters (the equivalent noise temperature of the noise diode, the offset of the reference load, and the antenna gain) jointly by using the global ocean and CS with both 110o and 180o pitch maneuvers after the reflector emissivity is calibrated. The results show that both calibration drift during eclipse season and bias over CS are removed. The RMSDs of the calibration drift over both the global ocean and CS are less than 0.1 K, and the goals of the calibration algorithm upgrade are achieved for coming L1B_TB version 4 data release.

Validation↗

The Aquarius ocean salinity mission high stability L-band radiometer

The NASA Earth Science System Pathfinder (ESSP) mission Aquarius, will measure global ocean surface salinity with ~120 km spatial resolution every 7-days with an average monthly salinity accuracy of 0.2 psu (parts per thousand) [1]. This requires an L-band low-noise radiometer with the long-term calibration stability of ≤0.15 K over 7 days. The instrument utilizes a push-broom configuration which makes it impractical to use a traditional warm load and cold plate in front of the feedhorns. Therefore, to achieve the necessary performance Aquarius utilizes a Dicke radiometer with noise injection to perform a warm – hot calibration. The radiometer sequence between antenna, Dicke load, and noise diode has been optimized to maximize antenna observations and therefore minimize NEDT. This is possible due the ability to thermally control the radiometer electronics and front-end components to 0.1 °Crms over 7 days.

Freedman, Adam↗

Development of a high stability microstrip-based L-band radiometer for ocean salinity measurements.

The development of a microstrip-based L-band Dicke radiometer with the long-term stability required for future ocean salinity measurements to an accuracy of 0.1 psu is presented. This will require the L-band radiometer requirements and configuration to achieve this objective. System configuration and component performance have been evaluated with radiometer test beds at both JPL and GSFC. The GSFC testbed uses a cryogenic chamber that al-lows long-term characterization at radiometric temperatures in the range of 70 - 120 K. The research has addressed several areas including component characterization as a function of temperature and bias, system linearity, optimum noise diode injection calibration and precision temperature control of components. A breadboard radiometer, utilizing microstrip-based technologies, has been built to demonstrate this long-term stability. This system is partially polarimetric providing V, H, -45 and +45 signals. Test results are compared to current and future ocean salinity radiometer requirements to show that the desire performance is possible.

Tanner, Alan B.↗

Lessons Learned from SMAP Radiometer Pre-/Post-launch Calibration

The Soil Moisture Active Passive(SMAP) mission was launched on 31stJanuary 2015 in a 6 AM/ 6 PM sun-synchronous orbit at 685 km altitude to measure soil moisture and free/thaw globally [1]. The passive instrument of SMAP is a fully polarimetric L-band radiometer (1.4GHz) operating with a bandwidth of 24MHz. The radiometer uses a combination of noise-diodes and Dicke-loads for internal calibration with a design similar to that used by the Aquarius or Jason series radiometers[2,3].Pre-launch calibration activities had been performed since 2012on the engineering model of the radiometer. Post-launch calibration activities have been performed to fine-tune and validate the results from the pre-launch calibration. The major calibration activities and lessons learned in the past 8 years will be described in the following sections.

Jinzheng Peng↗

Intensity noise in diode-pumped single-frequency Nd:YAG lasers and its control by electronic feedback

The power spectrum of the relative intensity noise (RIN) of single-frequency diode-pumped Nd:YAG lasers is observed to be shot-noise limited at frequencies above 20 MHz for a photocurrent of up to 4.4 mA. Relaxation oscillations result in noise 60-70 dB above shot noise at a few hundred kHz. These relaxation oscillations have been suppressed using electronic feedback.

Kane, Thomas J.↗

Frequency noise measurement of diode-pumped Nd:YAG ring lasers

The combined frequency noise spectrum of two model 120-01A nonplanar ring oscillator lasers was measured by first heterodyne detecting the IF signal and then measuring the IF frequency noise using an RF frequency discriminator. The results indicated the presence of a 1/f-squared noise component in the power-spectral density of the frequency fluctuations between 1 Hz and 1 kHz. After incorporating this 1/f-squared into the analysis of the optical phase tracking loop, the measured phase error variance closely matches the theoretical predictions.

Chen, Chien-Chung↗

Excess noise in high-current diamond diodes

We report the results of an investigation of low-frequency excess noise in high-current diamond diodes. It was found that the electronic excess noise of the diamond diodes is dominated by the 1/f and generation-recombination noise, which reveals itself as Lorentzian spectral features (f is the frequency). The generation-recombination bulges are characteristic of diamond diodes with lower turn-on voltages. The noise spectral density dependence on forward current, I, reveals three distinctive regions in all examined devices—it scales as I 2 at the low (I < 10 μA) and high (I > 10 mA) currents and, rather unusually, remains nearly constant at the intermediate current range. The characteristic trap time constants, extracted from the noise data, show a uniquely strong dependence on current. Interestingly, the performance of the diamond diodes improves with the increasing temperature. The obtained results are important for the development of noise spectroscopy-based approaches for device reliability assessment for high-power diamond electronics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-frequency noise characteristics of GaN vertical PIN diodes—Effects of design, current, and temperature

We report low-frequency noise characteristics of vertical GaN PIN diodes, focusing on the effects of the diode design, current, and temperature. The as-grown and regrown diodes, with and without surface treatment, have been studied. The noise in most of the GaN devices had a characteristic 1/f spectrum at high and moderate currents, while some devices revealed generation-recombination bulges at low currents (f is the frequency). The predominant trend of the noise spectral density, S I , dependence on the current was S I ~ I. All tested GaN PIN diodes had rather low normalized noise spectral densities of 10 –18 –10 –16 cm 2 /Hz (f = 10 Hz) at the current density J = 1 A/cm 2 at room temperature. The noise temperature dependences at different currents revealed peaks at T = 375–400 K. Temperature, current, and frequency dependences of noise suggest that the noise mechanism is of the recombination origin. Here, we argue that the noise measurements at low currents can be used to efficiently assess the quality of GaN PIN diodes.

36 MATERIALS SCIENCE↗

Low-frequency noise in β-(Al x Ga1 −x )2O3 Schottky barrier diodes

We report on the low-frequency electronic noise in β-(AlxGa1−x)2O3 Schottky barrier diodes. The noise spectral density reveals 1/f dependence, characteristic of the flicker noise, with superimposed Lorentzian bulges at the intermediate current levels (f is the frequency). The normalized noise spectral density in such diodes was determined to be on the order of 10−12 cm2/Hz (f = 10 Hz) at 1 A/cm2 current density. At the intermediate current regime, we observed the random telegraph signal noise, correlated with the appearance of Lorentzian bulges in the noise spectrum. The random telegraph signal noise was attributed to the defects near the Schottky barrier. The defects can affect the local electric field and the potential barrier and, correspondingly, impact the electric current. The obtained results help in understanding the noise in Schottky barrier diodes made of ultra-wide bandgap semiconductors and can be used for the material and device quality assessment.

Physics↗

Projected noise in submillimeter-wave mixers with InSb Schottky diodes

The reduction of the equivalent noise temperature in liquid-nitrogen-cooled submillimeter-wave mixers by the use of Schottky barriers on InSb instead of GaAs is evaluated by an analytical model that assumes limited local oscillator power and matched impedances. The calculations, executed at 1.0 and 1.8 THz, take plasma resonance and skin effect into account. For single and multiple contacts on homogeneous semiconductor materials of optimum doping, the noise of InSb diodes is smaller than that of GaAs diodes by a factor of 3 to 14. A simplified model is used to predict the performance of epitaxial structures as well as alternative materials.

Lieneweg, U.↗

Noise effects in an optical heterodyne spectrometer using tunable diode lasers

A comparison of measured and predicted signal-to-noise ratio is made in an optical heterodyne spectrometer utilizing a tunable diode laser which exhibited excess noise. It is shown that good agreement between predicted and measured signal-to-noise ratios results if excess noise effects due to tunable diode lasers are included in the predictions. The methods used to quantify excess noise and to incorporate their effects into predictions of signal-to-noise ratio are discussed.

Katzberg, S. J.↗

Guidance and control research

Effective work function of metal contacts to vacuum cleaved photoconducting cadmium sulfide, Curie point switching experiments, and germanium diodes for noise measurements

Source record↗

Determining the Nonlinearity of Microwave Receivers

Nonlinearity of microwave receiver measured and automatically corrected for by noise-adding radiometer built into microwave receiving circuit. Radiometer includes noise-adding diode, turned on and off by computer controlled processor.

Stelzried, C. T.↗