Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “noble liquids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Molecular hydrodynamic theory of the velocity autocorrelation function

The velocity autocorrelation function (VACF) encapsulates extensive information about a fluid’s molecular-structural and hydrodynamic properties. We address the following fundamental question: How well can a purely hydrodynamic description recover the molecular features of a fluid as exhibited by the VACF? To this end, we formulate a bona fide hydrodynamic theory of the tagged-particle VACF for simple fluids. Our approach is distinguished from previous efforts in two key ways: collective hydrodynamic modes and tagged-particle self-motion are modeled by linear hydrodynamic equations; the fluid’s spatial velocity power spectrum is identified as a necessary initial condition for the momentum current correlation. This formulation leads to a natural physical interpretation of the VACF as a superposition of products of quasinormal hydrodynamic modes weighted commensurately with the spatial velocity power spectrum, the latter of which appears to physically bridge continuum hydrodynamical behavior and discrete-particle kinetics. The methodology yields VACF calculations quantitatively on par with existing approaches for liquid noble gases and alkali metals. Furthermore, we obtain a new, hydrodynamic form of the self-intermediate scattering function whose description has been extended to low densities where the Schmidt number is of order unity; various calculations are performed for gaseous and supercritical argon to support the general validity of the theory. Excellent quantitative agreement is obtained with recent MD calculations for a dense supercritical Lennard-Jones fluid.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Production and testing of the large-area photon detector ArCLight

Compact large-area dielectric photon detectors that ensure modular noble liquid detectors can sense scintillation light signals for triggering and reconstruction purposes with minimal impact to the overall target volume. ArCLight is a small-volume, sizeable sensitive-area detector that consists of a light trap covered in a thin layer of TPB that can be placed inside a time projection chamber's electric field. These sensors are used in the Deep Underground Neutrino Experiment Near Detector liquid argon (DUNE ND-LAr). They are constructed and tested at the University of Bern and will be deployed in the prototype experiment ProtoDUNE-ND. The talk discusses the details of assembling ArCLights, the quality control methods, and the test studies done with LEDs to assess their performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing of a Line Driver With Configurable Pre-Emphasis on Lossy Transmission Lines

Rare-event physics experiments such as the Deep Underground Neutrino Experiment (DUNE) or the next Enriched Xenon Observatory (nEXO) experiment search for rare, low-energy events, detected by sensitive detectors immersed in a cryogenic noble liquid (e.g., liquid argon or xenon). Readout electronics used within such detectors must consume minimal power while operating reliably in cryogenic environments. Furthermore, in the case of nEXO, maximizing the radiopurity of the environment is vital to minimize background noise, thus placing strict limits on the volume of dielectric materials, leading to high-loss data cables spanning distances up to 12 m. Such cables cause high attenuation and intersymbol interference (ISI), resulting in a high bit-error rate (BER). These issues were addressed by developing an integrated line driver with configurable pre-emphasis in a 65-nm CMOS process. The pre-emphasis parameters can be programmed to minimize BER for specific cables and data rates under power constraints. Here, the driver was tested at both room and cryogenic temperatures. In both cases, the output BER was found to be strongly correlated with the pre-emphasis settings. Furthermore, analysis and simulation showed that adapting the pre-emphasis settings based on the incoming bit sequence can further improve performance with minimal changes to the current solution.

47 OTHER INSTRUMENTATION↗

Snowmass2021 cosmic frontier white paper: Ultraheavy particle dark matter

We outline the unique opportunities and challenges in the search for "ultraheavy" dark matter candidates with masses between roughly 10 TeV and the Planck scale $m_{\rm pl} ≈ 10^{16}$ TeV. This mass range presents a wide and relatively unexplored dark matter parameter space, with a rich space of possible models and cosmic histories. We emphasize that both current detectors and new, targeted search techniques, via both direct and indirect detection, are poised to contribute to searches for ultraheavy particle dark matter in the coming decade. We highlight the need for new developments in this space, including new analyses of current and imminent direct and indirect experiments targeting ultraheavy dark matter and development of new, ultra-sensitive detector technologies like next-generation liquid noble detectors, neutrino experiments, and specialized quantum sensing techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Snowmass Neutrino Frontier NF10 Topical Group Report: Netrino Detectors

We discuss here future neutrino detectors with physics goals ranging from the eV to the EeV scale. The focus is on future enabling technologies for such detectors, rather than existing detectors or those under construction. The report includes methodologies across the broad spectrum of neutrino physics: liquid noble and other cryogenic detectors, including LAr and LXe TPCs; photon-based detectors including technologies enabling hybrid Cherenkov/scintillation detectors; low-threshold detectors which use a wide variety of technologies to probe physics like coherent neutrino-nucleus scattering or detection of cosmic background neutrinos; and ultra-high energy detectors including optical and radio detectors, as well as tracking detectors for use at the forward physics facility of the LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analog optical signal transmission for HEP experiments

A critical element in all high-energy physics experiments is the signal transmission from the active elements to the data acquisition system. It is especially challenging in large volume detectors based on noble liquids that are extensively being used for dark matter and neutrino detection.The topic of this contribution is the optical signal transmission of the signals acquired with silicon photomultipliers, which is able to satisfy many stringent experimental requirements. It is RF-noise immune and operates in cryogenic liquids and in high-electric fields.This transmission system is based on commercially available electronics components and customized Fabry-Perot laser diodes.I will talk about encountered challenges, breakthrough, and advances from the original concept of this system up to final validation tests, demonstrating progressive developments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of the X-ARAPUCA Systems' Response for SBND's Light Detection

X-ARAPUCA waveform data, collected at a test stand at the Noble Liquid Test Facility (NLTF) and the Short Baseline Near Detector (SBND), were analyzed via python scripts. For the ARARA system, various distributions and correlations were studied, including the area and amplitude distributions of the waveform peaks for identifying single photoelectron peaks, as well as characterizing the behavior of the baseline artifact. The ARARA system is being studied in order to be implemented into SBND, just as the APSAIA X-ARAPUCAs have been.

Novotny, Andrew [U. Illinois, Chicago]↗

Studies to Improve the Sensitivity to Low Energy Interactions in Dual-Phase Xenon Dark Matter Detectors. Department of Energy Office of Science Graduate Student Research (SCGSR) Program, Final project report

Noble liquid time projection chambers (TPCs) are some of the most sensitive particle detectors ever developed. They see use in searches for new physics with neutrinos, or for new particles like dark matter. They work by sensing light and charge signals left behind by particle interactions in a volume of liquified xenon or argon. TPCs are so sensitive that even a single electron liberated in an interaction can be readily detected. However this sensitivity to signals comes with a sensitivity to background noise, with one example being single electrons that arrive long after the signals from a true particle interaction. This type of noise has been the subject of multiple studies, which have concluded that single electron backgrounds are well correlated with prior events in the TPC, as well as impurities in the detection medium. At Lawrence Livermore National Laboratory (LLNL), the XeNu TPC is a testbed for a novel study of these backgrounds by generating data with new components made of aluminum and Shapal--the latter being an exotic ceramic which can be machined using standard tools. These materials were selected to replace plastic components which introduce impurities in the TPC during operation. Without plastic, the hope is that electron backgrounds will be reduced, leaving new opportunities for studying their origins and dependence on impurities. The SCGSR fellowship served as a springboard to help meet these objectives. Over the course of a year, the new components were designed, fabricated, and installed in XeNu. Following their installation, data was taken for use in a future study that will enable the electron background contributions from plastic components to be studied directly. In the interim, preliminary analysis results indicate that electron backgrounds with the new components are roughly 50% lower. This has established the efficacy of Shapal as a low-background replacement for plastic components where electrical and thermal stability are needed

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Studies on the scintillation light detection in the ProtoDUNE Dual Phase liquid-argon TPC and its capability for the supernova trigger in DUNE

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims at addressing key questions in neutrino physics in the next decades. Its scientific program includes the detection of the neutrino flux from a core-collapse supernova. The DUNE far detector will have four 17-kt mass liquid-argon (LAr) time-projection chamber (TPC) modules. ProtoDUNE Dual Phase (DP), a dual-phase LAr TPC with 300 t of active mass and 6 m of drift distance, was operated with cosmic muons in 2019-2020 as part of an R&D program at the CERN Neutrino Platform to demonstrate the feasibility of the technology at such a large scale. In a LAr TPC, the photon detection system (PDS) provides fun- damental timing information and trigger capabilities. The PDS of ProtoDUNE-DP, which consisted of 36 photomultiplier tubes (PMTs), counted on a dedicated light calibration system (LCS) to monitor the PMT response. In this dissertation, the characterization and validation of the ProtoDUNE-DP PDS and LCS components before their installation will be reviewed, highlighting the results of general interest for experiments that use liquid noble gasses as target medium. The results from the stable performance of both systems in the detector during 15 months will be presented next as well as the studies on the scintillation light detection in ProtoDUNE-DP, where the collection of light produced in LAr at 7 m from the photosensors has been achieved for the first time. It is worth pointing out that the excellent LAr purity and the large size of the detector have enabled to develop a unique data-driven investigation on aspects that are critical for LAr- based experiments but that are not completely understood. The analyses cover the characterization of the low-energy background detected by the PDS, the quantification of the electric field impact on the light yield, the evaluation of the Rayleigh scattering affecting the light propagation, and the analysis of the PMT detection efficiency. The effect of the VUV reflectivity of the detector materials will be also discussed. In addition, the estimation of the cosmic muon flux crossing the TPC and the study of the observed light yield by the PDS will be reported. Finally, the results from the simulation-based study of the supernova burst trigger capability with the PDS of a 12.1-kt active mass dual-phase LAr TPC as the one proposed for DUNE will be summarized. Several configurations of reflective foils installed in the TPC to enhance the light collection will be compared

Gallego-Ros, Ana↗

Studies on the scintillation light detection in the ProtoDUNE Dual Phase liquid-argon TPC and its capability for the supernova trigger in DUNE

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims at addressing key questions in neutrino physics in the next decades. Its scientific program includes the detection of the neutrino flux from a core-collapse supernova. The DUNE far detector will have four 17-kt mass liquid-argon (LAr) time-projection chamber (TPC) modules. ProtoDUNE Dual Phase (DP), a dual-phase LAr TPC with 300 t of active mass and 6 m of drift distance, was operated with cosmic muons in 2019-2020 as part of an R&D program at the CERN Neutrino Platform to demonstrate the feasibility of the technology at such a large scale. In a LAr TPC, the photon detection system (PDS) provides fundamental timing information and trigger capabilities. The PDS of ProtoDUNE-DP, which consisted of 36 photomultiplier tubes (PMTs), counted on a dedicated light calibration system (LCS) to monitor the PMT response. In this dissertation, the characterization and validation of the ProtoDUNE-DP PDS and LCS components before their installation will be reviewed, highlighting the results of general interest for experiments that use liquid noble gasses as target medium. The results from the stable performance of both systems in the detector during 15 months will be presented next as well as the studies on the scintillation light detection in ProtoDUNE-DP, where the collection of light produced in LAr at 7 m from the photosensors has been achieved for the first time. It is worth pointing out that the excellent LAr purity and the large size of the detector have enabled to develop a unique data-driven investigation on aspects that are critical for LAr-based experiments but that are not completely understood. The analyses cover the characterization of the low-energy background detected by the PDS, the quantification of the electric field impact on the light yield, the evaluation of the Rayleigh scattering affecting the light propagation, and the analysis of the PMT detection efficiency. The effect of the VUV reflectivity of the detector materials will be also discussed. In addition, the estimation of the cosmic muon flux crossing the TPC and the study of the observed light yield by the PDS will be reported. Finally, the results from the simulation-based study of the supernova burst trigger capability with the PDS of a 12.1-kt active mass dual-phase LAr TPC as the one proposed for DUNE will be summarized. Several configurations of reflective foils installed in the TPC to enhance the light collection will be compared.

Gallego Ros, Ana↗

Characterization of the X-ARAPUCA systems' response for SBND's light detection

X-ARAPUCA waveform data, collected at a test stand at the Noble Liquid Test Facility (NLTF) and the Short Baseline Near Detector (SBND), were analyzed via python scripts. For the ARARA system, various distributions and correlations were studied, including the area and amplitude distributions of the waveform peaks for identifying single photoelectron peaks, which was able to be accomplished. The behavior of the baseline artifact was also characterized, which appeared only at high voltages/bright events, and separates further from the prompt peak as the voltage/brightness increases. The ARARA system is being studied in order to be implemented into SBND, just as the APSAIA X-ARAPUCAs have been.

Novotny, Andrew [Fermilab]↗

Catalytic combustion of coal-derived liquids

A noble metal catalytic reactor was tested with three grades of SRC 2 coal derived liquids, naphtha, middle distillate, and a blend of three parts middle distillate to one part heavy distillate. A petroleum derived number 2 diesel fuel was also tested to provide a direct comparison. The catalytic reactor was tested at inlet temperatures from 600 to 800 K, reference velocities from 10 to 20 m/s, lean fuel air ratios, and a pressure of 3 x 10 to the 5th power Pa. Compared to the diesel, the naphtha gave slightly better combustion efficiency, the middle distillate was almost identical, and the middle heavy blend was slightly poorer. The coal derived liquid fuels contained from 0.58 to 0.95 percent nitrogen by weight. Conversion of fuel nitrogen to NOx was approximately 75 percent for all three grades of the coal derived liquids.

Bulzan, D. L.↗

Investigations on a fuzzy process: effect of diffusion on calibration and particle identification in Liquid Argon Time Projection Chambers

Ionization electron diffusion in Liquid Argon Time Projection Chambers (LArTPCs) has typically been considered at the detector design stage, but little attention has been given to its effects on calibration and particle identification. We use a GEANT4-based simulation to study how diffusion impacts these techniques, and give consideration to how this effect is simulated. We find that diffusion can cause a drift-dependent bias to both the median and Most Probable Value (MPV) of dQ/dx distributions. The bias is estimated to be ~2.5% (median) and ~5.0% (MPV) for typical maximum drift times in currently running LArTPCs before adding detector specific considerations such as electric field non-uniformities. This information indicates that these metrics should not be used for calibration without care, contrary to the conventional wisdom. The impact of diffusion on the ability of LArTPCs to separate muons and protons is small, and not expected to pose any problems in future detectors. Diffusion may however be a significant source of systematic uncertainty when separating particles of more similar masses (muons and pions, kaons and protons). Separation of such populations may be improved by implementation of a drift-time dependent particle identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parameterization of electron attachment rate constants for impurities in LArTPC detectors

The ability of free electrons to drift long distances at high velocities in pure liquid argon under an applied electric field has been exploited for the past forty years to implement detectors with increasingly larger volumes for high energy physics research. The attachment of free electrons to impurities in the LAr is an important limit on the free instrumented volume of these extremely large detectors, and impurity concentrations as small as 100 ppt can reduce their resolution and efficiency. In this paper, we summarize the electron attachment rate constants as a function of the applied electric field, for common impurities in LArTPCs, obtained from data in the literature. Here, we further provide analytical functions to parameterize the data, which are useful to compare with new measurements, to model and analyze the performance of existing detectors, and to predict the performance of new detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of angle-resolved reflectivity of PTFE in liquid xenon with IBEX

Abstract Liquid xenon particle detectors rely on excellent light collection efficiency for their performance. This depends on the high reflectivity of polytetrafluoroethylene (PTFE) at the xenon scintillation wavelength of 178 nm, but the angular dependence of this reflectivity is not well-understood. IBEX is designed to directly measure the angular distribution of xenon scintillation light reflected off PTFE in liquid xenon. These measurements are fully described by a microphysical reflectivity model with few free parameters. Dependence on PTFE type, surface finish, xenon pressure, and wavelength of incident light is explored. Total internal reflection is observed, which results in the dominance of specular over diffuse reflection and a reflectivity near 100% for high angles of incidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and production of the high voltage electrode grids and electron extraction region for the LZ dual-phase xenon time projection chamber

The dual-phase xenon time projection chamber (TPC) is a powerful tool for direct-detection experiments searching for WIMP dark matter, other dark matter models, and neutrinoless double-beta decay. Successful operation of such a TPC is critically dependent on the ability to hold high electric fields in the bulk liquid, across the liquid surface, and in the gas. Careful design and construction of the electrodes used to establish these fields is therefore required. We present the design and production of the LUX-ZEPLIN (LZ) experiment's high-voltage electrodes, a set of four woven mesh wire grids. Grid design drivers are discussed, with emphasis placed on design of the electron extraction region. Here, we follow this with a description of the grid production process and a discussion of steps taken to validate the LZ grids prior to integration into the TPC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental partitioning of Zr, Ti, and Nb between silicate liquid and a complex noble metal alloy and the partitioning of Ti between perovskite and platinum metal

El Goresy et al.'s observation of Nb, Zr, and Ta in refractory platinum metal nuggets (RPMN's) from Ca-Al-rich inclusions (CAI's) in the Allende meteorite led them to propose that these lithophile elements alloyed in the metallic state with noble metals in the early solar nebula. However, Grossman pointed out that the thermodynamic stability of Zr in the oxide phase is vastly greater than metallic Zr at estimated solar nebula conditions. Jones and Burnett suggested this discrepancy may be explained by the very non-ideal behavior of some lithophile transition elements in noble metal solutions and/or intermetallic compounds. Subsequently, Fegley and Kornacki used thermodynamic data taken from the literature to predict the stability of several of these intermetallic compounds at estimated solar nebula conditions. Palme and Schmitt and Treiman et al. conducted experiments to quantify the partitioning behavior of certain lithophile elements between silicate liquid and Pt-metal. Although their results were somewhat variable, they did suggest that Zr partition coefficients were too small to explain the observed 'percent' levels in some RPMN's. Palme and Schmitt also observed large partition coefficients for Nb and Ta. No intermetallic phases were identified. Following the work of Treiman et al., Jurewicz and Jones performed experiments to examine Zr, Nb, and Ti partitioning near solar nebula conditions. Their results showed that Zr, Nb, and Ti all have an affinity for the platinum metal, with Nb and Ti having a very strong preference for the metal. The intermetallic phases (Zr,Fe)Pt3, (Nb,Fe)Pt3, and (Ti,Fe)Pt3 were identified. Curiously, although both experiments and calculations indicate that Ti should partition strongly into Pt-metal (possibly as TiPt3), no Ti has ever been observed in any RPMN's. Fegley and Kornacki also noticed this discrepancy and hypothesized that the Ti was stabilized in perovskite which is a common phase in Allende CAI's.

Jurewicz, Stephen R.↗

Lifetime study of the ColdADC for the Deep Underground Neutrino Experiment

ColdADC is a custom ASIC digitizer implemented in 65 nm CMOS technology using specialized techniques for long-term reliability in cryogenic environments. ColdADC was developed for use in the DUNE Far Detector complex, which will consist of four liquid argon time projection chambers. Each contains 17 kilotons liquid argon as the target material in order to measure neutrino oscillations. Approximately 40,000 ColdADC ASICs will be installed for DUNE in the first two large detectors and will be operated at cryogenic temperatures during the experiment without replacement. The lifetime of the ColdADC is a critical parameter affecting the data quality and physics sensitivity of the experiment. A measurement of the lifetime of the ColdADC was carried out, and the results shown in this paper assure orders of magnitude longer lifetime of the ColdADC than the planned operation time of the detectors.

Front-end electronics for detector readout↗