Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “neutron science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Volume 1: Introduction to the HFIR Futures - Enhanced Capabilities Series

Since it began operating at full power in 1966, the High Flux Isotope Reactor (HFIR) has contributed unparalleled neutron science capabilities to research on neutron scattering, isotope production, materials and fuels irradiation, and neutron activation analysis. HFIR is a high-performance, multi-mission research reactor operated on behalf of the US Department of Energy (DOE) at the Oak Ridge National Laboratory (ORNL). In 2020, a DOE Basic Energy Sciences Advisory Committee Subcommittee (BESAC) published a report recommending that DOE make significant investments in HFIR to enable continued operations beyond the year 2100 while also enabling new research and isotope production capabilities. ORNL organized an initiative to investigate how to specifically address the report’s key recommendations, including enabling long-term operation, brainstorming future scientific research needs, and outlining the infrastructure required to realize these future research capabilities. A multivolume series of reports has been developed to document the nonscattering enhancements. This volume, the introductory report, provides an overview of HFIR and the initiative.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Large field-of-view event-mode camera for high-precision epithermal neutron resonance imaging

A large-area event-mode camera system coupled with a 6 LiF-ZnS:Ag scintillator is applied for neutron resonance imaging (NRI) on the energy-resolved neutron imaging (ERNI) flight path, also known as Flight Path 5 (FP5), at the Los Alamos Neutron Science Center (LANSCE). This novel neutron imaging system, featuring a 120 x 120 mm 2 field of view, efficiently captures resonance information across the entire image in a single acquisition, significantly reducing beam time requirements compared to conventional energy-resolved neutron imaging systems. High-quality neutron radiographs with enhanced spatial resolution are achieved through the reconstruction of neutron events based on observations of individual photons emitted from the scintillator. The system demonstrates reduced background through neutron/gamma discrimination capabilities while maintaining sharpness across a large fields of view. In the measurements presented here, a spatial resolution of approximately 340 μm was achieved using center-of-gravity photon cluster centroiding. We demonstrate the system’s capability for quantitatively determining isotopic distributions in various thin samples, as well as automatically reconstructing complex scenes with overlapping resonances from diverse samples. These results are obtained using standard data analysis tools, despite the relatively slow 6 LiF-ZnS:Ag scintillator, which may not be optimal for absorption resonance detection. The capabilities demonstrated here offer a valuable, versatile, and cost-effective solution for high spatial and temporal resolution, large field-of-view energy-resolved neutron imaging, with potential applications across various scientific and industrial domains.

36 MATERIALS SCIENCE↗

Total kinetic energy release in the fast-neutron-induced fission of Np 237

The total kinetic energy (TKE) release in the fast neutron-induced fission of 237Np was measured for neutron energies from En = 2.6–100 MeV at the Los Alamos Neutron Science Center at the Weapons Neutron Research facility. The post-TKE release decreases nonlinearly with increasing incident neutron energy and can be represented as TKE(MeV) = (174.38 ± 0.72) – (5.11 ± 0.5821) log 10 E n for En > 1 MeV. Analysis of the fragment mass distributions indicates that the decrease in TKE with increasing E n is a consequence of the fading out of shell effects at high excitation energies (resulting in an increase of symmetric fission) and the decrease of the total kinetic energy associated with asymmetric fission with increasing E n .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantification of the light output anistropy in deuterated stilbene

Deuterated stilbene is an organic scintillator that is a desirable material for fast neutron spectroscopy using spectrum unfolding techniques without requiring time-of-flight information. Due to the crystal structure of the material, some anisotropy of the light output exists, which is dependent on the direction of heavy charged particle recoil relative to the crystal structure. The anisotropy of trans-stilbene (hereafter referred to as stilbene) has been well characterized in previous work, but for deuterated stilbene, the anisotropy has only been partially characterized along the a and b crystal axes, while the artificial c' axis, which shows the largest anisotropy in stilbene, has not been characterized until this publication. Here, in this work, two deuterated stilbene crystals were characterized with neutron energies up to 35 MeV at the Los Alamos Neutron Science Center. For one of the crystals, the response is characterized along the a, b, and c' axes. This characterization shows a distinct anisotropy along the axes in deuterated stilbene, which is very similar to that found in regular stilbene, such that the a axis is the brightest, while the b' and c' axes are approximately 3% and 20%–35% lower relative to the a axis.

36 MATERIALS SCIENCE↗

Oak Ridge National Laboratory Neutron Spin Echo Beamline on NB-2

Neutron Spin Echo (NSE) spectroscopy uniquely measures the Q-dependence of slow relaxation dynamics, and having such a machine at HFIR will advance polarized neutron spectroscopy and promote the study of biophysical and energy materials using neutrons. The 2018 Instrument Advisory Board (IAB) advises Neutron Sciences Directorate, ORNL to upgrade the cold neutron delivery system at HFIR, addressing geometrical challenges in neutron transfer from the bright cold source. This is being optimized now: the entrance to the guide system is moving closer to the source, and more guides are being added. However, there are still significant challenges to making the cold flux at the sample world-class. With the proposed guide system, NB-2 can deliver more than 10 6 polarized neutrons per cm 2 /sec below 8Å, and probably 10Å with further optimization. With no potential for running user experiments with neutrons longer than 15Å, the utility of such a machine for biological studies is limited. However, there is a large demand for this class of spectrometer in materials science, chemical engineering, and nanotechnology. Workshops held over the past decade and the three-source vision have highlighted the community's need for a low-angle, high-energy resolution spectrometer at HFIR. A detailed design study of this spectrometer is needed, focusing on optimizing the neutron delivery system for SANS-type studies. This neutron spectrometer would complement studies already performed on both SNSNSE and BASIS by overlapping and extend the dynamic range accessible, while acknowledging the proposed machine, EXPANSE, at the Second Target Station. Two technologies currently exist for such a spectrometer: traditional DC solenoids like those on BL-15 at SNS and IN15 at the ILL, and RF-flipper-based machines similar to RESEDA at FRMII. Either instrument would satisfy the scientific justification. However, there are strong business and scientific cases to utilize the thermal flux, the resonant expertise developed at ORNL, and the potential to utilize an entangled beam of neutrons to probe quantum matter by adopting the neutron resonant spin-echo configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LANSCE Capabilities

For more than 40 years the Los Alamos Neutron Science Center (LANSCE) has provided the scientific underpinnings in nuclear physics and material science needed to ensure the safety and surety of the nuclear stockpile into the future. In addition to national security research, the LANSCE User Facility has a vibrant research program in fundamental science, providing the scientific community with intense sources of neutrons and protons to perform experiments supporting civilian research and the production of medical and research isotopes.

43 PARTICLE ACCELERATORS↗

Irradiation damage concurrent challenges with RAFM and ODS steels for fusion reactor first-wall/blanket: a review

Reduced activation ferritic martensitic (RAFM) and oxide dispersion strengthened (ODS) steels are the most promising candidates for fusion first-wall/blanket (FW/B) structures. The performance of these steels will deteriorate during service due to neutron damage and transmutation-induced gases, such as helium/hydrogen, at elevated operating temperatures. Here, after highlighting the operating conditions of fusion reactor concepts and a brief overview, the main irradiation-induced degradation challenges associated with RAFM/ODS steels are discussed. Their long-term degradation scenarios such as (a) low-temperature hardening embrittlement (LTHE)—including dose-temperature dependent yield stress, tensile elongations, necking ductility, test temperature effect on hardening, Charpy impact ductile-to-brittle transition temperature and fracture toughness, (b) intermediate temperature cavity swelling, (c) the effect of helium on LTHE and cavity swelling, (d) irradiation creep and (e) tritium management issues are reviewed. The potential causes of LTHE are discussed, which highlights the need for advanced characterisation techniques. The mechanical properties, including the tensile/Charpy impact of RAFM and ODS steels, are compared to show that the current generation of ODS steels also suffers from LTHE, and shows irradiation hardening up to high temperatures of ~400 °C–500 °C. To minimise this, future ODS steel development for FW/B-specific application should target materials with a lower Cr concentration (to minimise α'), and minimise other elements that could form embrittling phases under irradiation. RAFM steel-designing activities targeting improvements in creep and LTHE are reviewed. The need to better understand the synergistic effects of helium on the thermo-mechanical properties in the entire temperature range of FW/B is highlighted. Because fusion operating conditions will be complex, including stresses due to the magnetic field, primary loads like coolant pressure, secondary loads from thermal gradients, and due to spatial variation in damage levels and gas production rates, an experimentally validated multiscale modelling approach is suggested as a pathway to future reactor component designing such as for the fusion neutron science facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Testing the Activation Analysis for Fusion in OpenMC

OpenMC is a community-developed Monte Carlo neutron and photon transport simulation code. It can perform fission simulations such as fixed-source, k-eigenvalue, and subcritical multiplication calculations on models built using either a constructive solid geometry or CAD representation. To explore the use of OpenMC for fusion activation analysis, a detailed model of the Fusion Neutronics Science Facility (FNSF) was first developed for comparisons against an existing SERPENT model. A 90-degree model of FNSF in Standard-Triangle-Language (STL) CAD format was converted to Constructive Solid Geometry (CSG) using each code's built-in functions, and the geometries were validated by ensuring no cells overlapped and no particles were lost during simulations. The neutron fluxes were calculated and compared for multiple components close to the plasma. The results show differences mostly below 1% in fluxes and averaged 8% for activity and decay heat. Here, the work described in this study tests the CAD-based geometry using the DagMC toolkit in OpenMC and compares the activation analysis of OpenMC to SERPENT code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Density Measurement of NaCl-MgCl 2 -PuCl 3 and NaCl-UCl 3 -PuCl 3 Molten Salt Systems by Neutron Radiographic Dilatometry

A novel neutron radiographic technique was developed and implemented to measure the change in volume as a function of temperature of select plutonium-containing liquid chloride mixtures from melt to 1250 K. These measurements were performed at Los Alamos National Laboratory by members of the molten salt research group under support from Gateway for Accelerated Innovation in Nuclear (GAIN) voucher NE-21-25117: “Density Measurements of Plutonium Bearing Salts via Neutron Beam Dilatometry”. This technical report contains a description of the experimental method and a summary of the results. Initial characterization of the {NaCl, MgCl 2 , UCl 3 , PuCl 3 } salts used in this experiment includes a combination of x-ray diffraction, differential scanning calorimetry, gamma ray spectroscopy, and inductively coupled plasma mass spectrometry. Four samples of NaCl + MgCl 2 + x mol% PuCl 3 and four samples of NaCl + UCl 3 + x mol% PuCl 3 were prepared at the Plutonium Facility, shipped to the Los Alamos Neutron Science Center (LANSCE), and radiographed with the density via neutron radiography (DvNR) apparatus. Density data in the form of meniscus heights were recorded as a function of temperature. The results show a linear dependence of density with temperature and a third order polynomial dependence of density with composition as a function of PuCl 3 addition in the corresponding halide salt mixture. Additions of PuCl 3 result in a significant increase in density of the salt mixture and a slight reduction in the coefficient of volumetric expansion. These results represent a first measurement of the density of plutonium chloride salt mixtures and, in combination with additional measurements, may lead to a generalized description of the density of such salt systems for arbitrary compositions and temperature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of the 239 Pu(n,f)/ 235 U(n,f) Cross-Section Ratio with the NIFFTE fission Time Projection Chamber

In this work, the 239 Pu(n,f)/ 235 U(n,f) cross-section ratio has been measured with the fission Time Projection Chamber (fissionTPC) from 100 keV to 100 MeV. The fissionTPC provides three-dimensional reconstruction of fission-fragment ionization profiles, allowing for a precise quantification of measurement uncertainties. The measurement was performed at the Los Alamos Neutron Science Center which provides a pulsed white source of neutrons. The data are recommended to be used as a cross-section ratio shape. A discussion of the status of the absolute normalization and comparisons to ENDF evaluations and previous measurements is included.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constraining the nuclear spin distribution using improved 197 Au neutron resonance parameters

New neutron transmission data at resonance energies using a 197 Au sample were measured using an early version of the Device for Indirect Capture Experiments on Radionuclides (DICER), which is under development at the Los Alamos Neutron Science Center (LANSCE). These data were combined with previous neutron transmission and capture data in a simultaneous R-matrix analysis to extract improved neutron resonance parameters for this nuclide. As a result, total radiation widths, Γ γ , were obtained for 33 J=1 and 44 J=2 197 Au+n resonances. Γ γ distributions for these two spins states were compared to distributions calculated according to the nuclear statistical model using published nuclear level density (NLD) and photon strength functions (PSF) measured using the Oslo technique. The calculated distributions were found to be narrower and the average values for the two spins states closer together than the data. The calculation can be brought into agreement with the data by substantial modifications to the spin distribution in 198 Au as a function of excitation energy. As far as we know, the spin distribution currently is otherwise poorly constrained. The modified spin distribution changes the shapes of the NLD and PSF extracted using the Oslo technique and so could have broad implications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laboratory Directed Research and Development Program (FY 2019 Annual Summary of Completed Projects)

Oak Ridge National Laboratory (ORNL) is the US Department of Energy’s (DOE’s) largest multiprogram science, technology, and energy laboratory with distinctive capabilities in neutron science, computing, advanced materials, and nuclear science and technology. Using these capabilities, ORNL conducts basic and applied research and development (R&D) to support DOE’s overarching mission to “ensure America’s security and prosperity by addressing its energy, environmental and nuclear challenges through transformative science and technology solutions.” As a national resource, ORNL also applies its capabilities and skills to specific needs of other federal agencies and customers through the DOE Strategic Partnership Projects (SPP) program. Information about the laboratory and its programs is available at the ORNL website. The Laboratory Directed Research and Development (LDRD) program at ORNL operates under the authority of the DOE Order 413.2C, “Laboratory Directed Research and Development,” which establishes DOE’s requirements for the program while providing the laboratory director broad flexibility for program implementation. The LDRD program funds are obtained through a charge to all laboratory programs. ORNL reports on the program status to DOE each year.

99 GENERAL AND MISCELLANEOUS↗

Development of Large-Volume-Diamond Anvil Cell for Neutron Diffraction: The Neutron Diamond Anvil Cell Project at ORNL

10 years ago, Dave Mao, director of EFree (energy frontier research in extreme environments), a DOE energy frontier recognized the importance of neutron science for energy research. The subsequent establishment of a neutron group within EFree lead to the establishment of an “Instrument Development Team” for SNAP, the High-Pressure beamline at the Spallation Neutron Source at Oak Ridge National Laboratory in Tennessee. The idea was to develop novel high pressure techniques to expand the pressure range for neutron diffraction. A goal was set to reach half megabar levels (50 GPa), which at the time was considered as extremely challenging. Here we will give a brief overview of the developments during the last decade in this novel area of research. Fortunately, during this period multi carat diamond anvils have become available mainly by the chemical vapor deposition process (CVD), making research in this pressure range and beyond rather routine. This paper shows the latest developments in large anvil designs, compact multiple ton diamond cells and some examples of high-quality neutron diffraction patterns of sample sizes far below conventional levels.

Boehler, Reinhard↗

Physical Sciences Vistas Issue 3 2021

In this issue, highlights of our contributions to mission operations include descriptions of the following. • How exact and scrupulous planning in concert with sophisticated science enabled a first-ever direct measurement of a radionuclide with a half-life as short as six days. The work, which included operations at the Los Alamos Neutron Science Centers (LANSCE) Weapons Neutron Research Facility and the Isotope Production Facility’s hot cell facility, is a boon for both astrophysics and weapons science. • An introduction to Christie Davis and her role in ensuring the Lab’s execution of simultaneous excellence. • A look at progress by AOT’s Target and Experimental Support Team in reclaiming long-dormant space in a radiological controlled area for new work improving target systems for the Lujan Center. • A story showcasing a cross-organizational effort to minimize the directorate’s legacy and environmental footprint. Staff from across the Lab joined together to ensure the safe and efficient disposal of Rocky Flats legacy waste stored in a transportainer at the Target Fabrication Facility. • How the Lab’s Utilities and Infrastructure experts collaborated with stakeholders in our directorate to safety execute preventive maintenance on the LANSCE mesa’s large electrical substation. The Safe Conduct of Research principles provided a common framework for the planning and process. • A description of the resources called upon and the procedures undertaken by MPA to inventory the division’s time-sensitive chemicals, including the careful and conscientious response of an alert team member when something seemed amiss.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A holistic approach to the optimization of neutron beam transport at the LANSCE facility

An advanced neutron beam collimation system has been developed as part of an effort to optimize neutron beam transport at the Weapons Neutron Research (WNR) Facility, located within the Los Alamos Neutron Science Center (LANSCE). The goal of this work was to develop and demonstrate techniques to tailor neutron delivery in order to provide maximum available flux on sample with a specific beam profile, while simultaneously reducing unwanted background. A holistic approach was taken, upgrading the facility spallation target, facility metrology infrastructure, and flight path shutter insert to support the implementation of this advanced collimation system. Here, modern instruments and software were employed to conduct facility surveys, characterization of as-built geometry of critical components, 3D ray tracing and neutron transport calculations. Beam images and flux measurements were acquired after installation to evaluate the performance of the collimation system and to demonstrate consistent agreement with MCNP simulations which showed an 87% increase of flux on sample while providing suppression of background neutron impingement on the sample frame by 10 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning a time-gated camera for fast neutron beamline spatial-energy characterization at LANSCE-WNR spallation source

An energy-resolved fast neutron beam imaging diagnostic has been successfully commissioned at the Weapons Neutron Research (WNR) spallation source within the Los Alamos Neutron Science Center (LANSCE) facility. This diagnostic replaces the existing analog phosphor image plates, which integrate across all neutron energies, as well as other particles, with a near-real-time energy-sensitive imaging capability. The system uses a fast plastic scintillator coupled with an intensified CCD camera. Specifically, the Teledyne Pi-MAX4 camera is coupled with either a 4 mm thick Eljen (EJ) 204 or 228 plastic scintillator. These scintillators are most sensitive to the fast neutrons (0.8-800 MeV) directly from the spallation source rather than low energy background radiation. Experimentally, these plastic scintillators were shown to have sufficiently fast decay to differentiate the bright gamma flash from the spallation neutrons. The spatial resolution is dominated by neutron beam divergence, with minimal additional contributions from scatter and light divergence. The system successfully resolved changes in neutron beam characteristics caused by intentional proton steering variations. Additionally, simulations of scintillator light yield as a function of thickness conducted using PHITS (with Scinful-QMD package) found that increasing scintillator thickness from 4 mm to 6 or 8 mm could potentially increase brightness ~ 3x. This may be explored if there is a need to reduce image acquisition time from several minutes to under one minute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physical Sciences Vistas Perspectives on LANSCE Issue 2, 2022

What’s LANSCE? The Los Alamos Neutron Science Center is a facility at the Lab with one of the nation’s most powerful linear accelerators, which is a half-mile in length. What’s an accelerator? An accelerator is a machine that uses electric or time-varying magnetic fields to accelerate nuclear particles to high velocities.

43 PARTICLE ACCELERATORS↗