Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “net load management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

NREL Project CloudZero

The National Renewable Energy Laboratory's (NREL's) CloudZero project is evaluating the ability to reliably and securely manage complex energy systems from the cloud, identifying major technical and regulatory barriers to cloud adoption, suggesting new security controls and best practices for cloud applications, and empowering industry to embrace the cloud, where appropriate.

cloud↗

Community-Scale Energy Efficiency Assessment for Zero Net Energy Using the URBANopt Simulation Platform: Preprint

This project explored an innovative modeling approach for assessing the energy efficiency potential of the existing low-income Oceano neighborhood, in unincorporated San Luis Obispo County, and its effects on renewable generation requirements for achieving zero net energy (ZNE). One particular challenge faced was ascertaining the technical energy savings potential across a large neighborhood in a timely manner. The project overcame this challenge through the use of the URBANopt simulation platform, developed at the National Renewable Energy Laboratory. URBANopt manages the automated model creation, simulation, and result aggregation for different design scenarios of existing or candidate buildings in a large neighborhood. Customized energy efficiency packages considered for the residential and commercial sector in the neighborhood included lighting, HVAC, plug load, water heating, envelope, and energy education measures. As a result of the analysis for the Oceano community, energy efficiency measures that are available through incentive programs may provide a 7.4% reduction in the required distributed energy resource (DER) size, corresponding to a 25,000 ft2 decrease in PV array area, to achieve ZNE. Through this work, a computational tool was developed and is being leveraged by the County of San Luis Obispo (CoSLO). The tool has enabled the CoSLO staff to perform similar analysis of the technical potential for energy efficiency, and an understanding of the DER asset requirements and potential savings in other communities within the county.

building energy modeling↗

Analysis of combustion chamber deposit growth on temperature swing thermal barrier coatings in a spark ignition engine

Temperature swing thermal barrier coatings (TBCs) have the potential to improve efficiency and performance through thermal management of the combustion chamber. However, the effects of combustion chamber deposits (CCDs) on the surface of the TBCs are unclear. Therefore, this paper analyzes the impact of CCD formation on a temperature swing TBC. A piston and a heat flux probe coated with a novel material are installed in a single-cylinder research engine at a low-load condition for 62.5 h to promote CCD growth. Every 12.5 h, the performance at a knock limited condition is assessed and thermophysical property measurements on the heat flux probe are performed. Net thermal efficiency increased by 0.4% absolute after 12.5 h relative to the baseline condition, but further CCD growth caused a dithering of efficiency between the 12.5 h and baseline points. The KLSA retarded consistently throughout this period. As a result, external property measurements with the coated heat flux probe showed an improvement in the thermophysical properties of the TBC/CCD layer.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential of Data Center Controls in Grid Services

The rapid proliferation of large data centers brings both challenges and opportunities for grid reliability. The data center resources and their potential flexibility have the potential to contribute resources to grid operations. Through capabilities like energy shifting and resource coordination, data centers can help reduce their net demand on the transmission network, as well as provide additional grid services to support reliable operation on the grid. While transient and long-term grid planning and operations are the scenarios that draw most attention, the quasi-steady state timeseries (QSTS) operation of data centers and grid bring interesting scenarios that can help evaluate the data center controls to aid grid services. This work is focused on modeling data centers for QSTS applications – incorporating the AI data center load profiles and building on the PNNL digital twin model for the thermal management loads to enable simulation studies to reveal the impact of data center controls on grid performance. This includes the integration of a QSTS battery and natural gas generator model to incorporate local resource impacts to the system. The simulation study is performed with a modified IEEE 24-Bus transmission system. Scenarios are focused on evaluating the data center load impacts on the transmission system and leveraging both data center and local generation controls to mitigate those impacts and provide additional grid services. The data center controls revealed the ability to contribute to two main kinds of grid services: preventing congestion on a weak grid by coordinating the data center resources with the collocated BESS and onsite generation; and the ability to help the grid operations during stressed times of operation like during a contingency. Leveraging these and other capabilities has the potential to help data centers become grid responsive assets, aiding in both their integration into the power system and grid reliability.

power grid simulation↗

Laboratory Evaluation of Federated, Hierarchical Controls for Distribution Power System Management: Preprint

The connection of more loads and distributed energy resources (DERs) to the distribution power system brings both challenges and opportunities to system operators. There are opportunities to aggregate flexible loads and DERs to provide transmission grid services, but the coordinated actions of DERs being managed by independent, third-party DER aggregators to support transmission system operations can present challenges. We developed a federated DER management architecture and control framework that aims to manage heterogeneous DERs to deliver reliable transmission grid services while respecting distribution system constraints. The controls include stochastic day-ahead optimization, model predictive control, and a simple real-time management scheme. We present simulation results obtained from a realistic laboratory test bed of federated controls managing DERs within a substation service area to make the substation net power follow the optimal net power determined by the day-ahead optimization based on cost and limiting reverse power flow.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SunDial – An Integrated SHINES System to Enable High-penetration Feeder-level PV

The Project Team of Fraunhofer USA, National Grid, and IPKeys developed and conducted a pilot deployment of the SunDial system, a virtual power plant platform that enables high-penetrations of solar PV to be integrated into the distribution grid. The pilot was conducted over a 15-month period from August 2018 through October 2019 on a National Grid distribution feeder in Shirley, MA. A vendor-agnostic control platform (the “Global Scheduler”) optimally shaped the net load for a virtual portfolio of non-co-located DERs based on user-defined policy objectives. The goal of the SunDial project was to simplify and reduce the risk associated with the deployment of solar in high-penetration environments by: (1) Developing an open-source, vendor-agnostic dispatch platform that can be readily adapted to optimize control of DERs over a variety of use cases; (2) Developing auto-calibrating load and solar prediction methodologies that can be readily implemented and scaled to new deployments; (3) Developing a methodology to use demand-side management with traditional electrochemical energy storage to provide “load shaping” services in high solar penetration environments; (4) Using grid-scale storage to minimize short-term intermittency association with PV production; and (5) Deploying on the National Grid distribution system to gain experience on the potential for (and limits of) integrated storage with demand-side management.

14 SOLAR ENERGY↗

A Path to 100 Percent Renewable Energy: Grid-Forming Inverters will Give Us the Grid We Need Now

This is a more urgent problem than it might sound. The westernmost Hawaiian island of significant size, Kauai is home to around 70,000 residents and 30,000 tourists at any given time. Renewable energy accounts for 70 percent of the energy produced in a typical year - a proportion that's among the highest in the world and that can be hard to sustain for such a small and isolated grid. During the day, the local system operator, the Kauai Island Utility Cooperative, sometimes reaches levels of 90 percent from solar alone. But on 2 April, the 26-MW generator was running near its peak output, to compensate for the drop in solar output as the sun set. At the moment when it failed, that single generator had been supplying 60 percent of the load for the entire island, with the rest being met by a mix of smaller generators and several utility-scale solar-and-battery systems.

battery management systems↗

Real time side-by-side experimental validation of energy and comfort performance of a zero net energy retrofit package for small commercial buildings

Making buildings zero-net energy (ZNE) is one of the major strategies for achieving carbon emission reduction goals. For this strategy to be successful, it entails a very significant reduction in energy use – 50% or more. In small commercial buildings, however, owners and building management teams usually have limited resources for identifying, analyzing, and procuring appropriate retrofit measures for reducing such use. An approach to overcome this limitation is the development of bundles of energy efficiency measures that can be presented to building owners/operators as a comprehensive package. The research presented in this paper focuses on an experimental evaluation of the impacts of a retrofit package developed for small office buildings in California. Performing this evaluation in a full-scale whole-building integrated systems test facility allowed a side-by-side evaluation in real time, against a reference case, of the impact of the retrofit package not only on energy use but also on visual and thermal comfort. Here, the retrofit package evaluated is comprised of a combination of HVAC, lighting (including daylighting), and plug load measures. The evaluation occurred at different times of the year in order to account for seasonal variations in environmental conditions, including solar angles and weather. The experimental facility allowed testing for two different façade orientations: south and west. Results show that the proposed ZNE retrofit package can save significant amounts of energy for small commercial buildings. During cooling-prevalent periods, total energy savings were 65% for south orientation and 68% for west orientation; during heating-prevalent periods total energy savings were 22% for south orientation and 25% for west orientation. Measurements indicate that the ZNE retrofit package resulted in small but not very significant changes in comfort levels for building occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of climate change on water availability and its propagation through the Western U.S. power grid

Climate impact assessment for power systems has tended to focus on the effects of water availability on generation without explicitly considering how these impacts propagate through the interconnected grid to affect generation in other locations. We investigate the impact of projected water availability on the operations of the contemporary Western U.S. power grid, focusing specifically on regional interdependencies. Hydrologic simulations derived from three GCMs (CCSM4, INMCM4 and GFDL-CM3) and two radiative scenarios (RCP4.5 and RCP8.5) are used to force a large-scale, distributed water management model (MOSART-WM), which translates water availability into power generation constraints at hydropower plants and water-dependent thermo-electric plants. Power system dynamics are evaluated using the production cost model PLEXOS. We find that the inter-regional connections across the Western U.S. electricity infrastructure are key in managing drastic variations in regional water availability. Net generation in the Northwest and Northern California is substantially sensitive to local water availability. Generation from the Desert Southwest emerges as a critical resource to compensate for variations in water availability in those regions. Climate change impacts on Northwestern water availability therefore drive future changes in other regions’ generation and regional power flows. The large inter-annual hydrological variability of Northern California exacerbates grid stress arising from long-term changes in water availability in the Northwest. While the regional power flow directions seem insensitive to long-term variations in water availability, the analysis highlights the need to consider other compounding regional factors such as changes in Southern California net load or changes in regional fuel prices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rubisco activity and activation state dictate photorespiratory plasticity in Betula papyrifera acclimated to future climate conditions

Plant metabolism faces a challenge of investing enough enzymatic capacity to a pathway without overinvestment. As it takes energy and resources to build, operate, and maintain enzymes, there are benefits and drawbacks to accurately matching capacity to the pathway influx. The relationship between functional capacity and physiological load could be explained through symmorphosis, which would quantitatively match enzymatic capacity to pathway influx. Alternatively, plants could maintain excess enzymatic capacity to manage unpredictable pathway influx. In this study, we use photorespiration as a case study to investigate these two hypotheses in Betula papyrifera. This involves altering photorespiratory influx by manipulating the growth environment, via changes in CO 2 concentration and temperature, to determine how photorespiratory capacity acclimates to environmental treatments. Surprisingly, the results from these measurements indicate that there is no plasticity in photorespiratory capacity in B. papyrifera, and that a fixed capacity is maintained under each growth condition. The fixed capacity is likely due to the existence of reserve capacity in the pathway that manages unpredictable photorespiratory influx in dynamic environments. Additionally, we found that B. papyrifera had a constant net carbon assimilation under each growth condition due to an adjustment of functional rubisco activity driven by changes in activation state. These results provide insight into the acclimation ability and limitations of B. papyrifera to future climate scenarios currently predicted in the next century.

59 BASIC BIOLOGICAL SCIENCES↗

RAVIS: Resource Forecast and Ramp Visualization for Situational Awareness - An Introduction to the Open-Source Tool and Use Cases

The Resource Forecast and Ramp Visualization for Situational Awareness (RAVIS) is an open-source tool for visualizing variable renewable resource forecasts and ramp alerts for significant up/down ramps in renewable resource and the consequent net-load. The modular dashboard of RAVIS contains configurable panes for viewing- probabilistic time series forecasts, ramp event alerts on the look-ahead timeline, spatially resolved resource sites and forecasts, and system simulation and market clearing data such as transmission lines utilization, nodal prices and available generation flexibility. RAVIS uses a technology suite that is assembled to provide optimum visualization facility while maintaining a wide pool of potential deployment and client environments. The tool is designed to take advantage of web application technologies, open source visualization libraries and tooling. Utilizing this technology will enable deployment in any environment, using any operating system, and is scalable to much higher spatial and temporal scales of visualization. As a prototype of the tool and demonstrating a use case of variable renewable integration, RAVIS currently integrates site-specific solar power forecasts in the California Independent System Operator (CAISO) and Mid-continent ISO (MISO) footprint from the IBM WattSun forecasting platform, and also superimposes market simulation data for CAISO footprint from as in-house NREL market clearing tool. The tool has the ability to alert the viewer for excessive up or down ramps for both individual solar sites as well as regionally aggregated net-load ramps, and alerts can also be qualified with respect to available flexible generation. This report will provide an introduction to the RAVIS tool, and summarize the above mentioned capabilities, typical use cases and possible extensions of the tool. The RAVIS development team believes there are likely to be high economic and reliability benefits of integrating probabilistic forecasts of variable renewables into control center visualizations and improved ramp events situational awareness for system operators and forecasting teams in the ISOs and electric utilities in comparison with their business as usual practices.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

US building energy efficiency and flexibility as an electric grid resource

Buildings consume 75% of U.S. electricity; therefore, improving the efficiency and flexibility of building operations could increase the reliability and resilience of the rapidly-changing electricity system. We estimate the technical potential near- and long-term impacts of best available building efficiency and flexibility measures on annual electricity use and hourly demand across the contiguous U.S. Co-deployment of building efficiency and flexibility avoids up to 742 TWh of annual electricity use and 181 GW of daily net peak load in 2030, rising to 800 TWh and 208 GW by 2050; at least 59 GW and 69 GW of the peak reductions are dispatchable. Implementing efficiency measures alongside flexibility measures reduces the potential for off-peak load increases, underscoring limitations on load shifting in efficient buildings. Overall, however, we find a substantial building-grid resource that could reduce future fossil-fired generation needs while also reducing dependence on energy storage with increasing variable renewable energy penetration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Fast Flexibility-Driven Generation Portfolio Planning Method for Sustainable Power Systems

We are witnessing an acceleration in the uptake of renewable energy in power systems. Because of the associated variability and uncertainty of renewables, power systems need to have an adequate supply of flexibility to allow for suitable management of short-term operations. So far most of the work in this area has neglected how flexibility needs associated with renewables are fulfilled as part of dispatchable generation capital investments decisions. To address this challenge, we propose an approach to plan the dispatchable generation mix of a power system as needed to counteract variability and uncertainty associated with significant shares of variable renewable generation. The approach exploits the linear time-invariant feature of variable generation variability using historical phase planes of capacity (in MW) and ramp (in MW/min) to bridge the gap between long-term capacity planning and short-term intra-hour flexibility needs. This approach is much more computationally tractable than other proposals, while also being able to capture adequately short-term operational features like ramping and net load variability. Numerical tests are performed on realistic datasets to substantiate the effectiveness of the approach.

bulk power system planning↗

Potential Impacts of Dynamic Electricity Pricing in California: Load Shape and Customer Bill Impacts Under Elastic Customer Response

The increasing penetration of renewable energy in California has intensified grid management challenges, exemplified by the “duck curve” and the resulting need for steep ramping and curtailment of renewables. To address these issues, dynamic electricity tariffs that vary in near-real time are being considered to incentivize customers to shift demand and support the grid. This study extends previous work on the bill impacts of such tariffs in the absence of load response by quantifying the system-level and customer impacts of load response based on customer price elasticity. Customer-level load response modeling was conducted using meter data from 411,000 customers across residential, commercial, and industrial sectors. Customer demand elasticity was estimated using literature-based values, with scenarios ranging from low to high elasticity, including an automation-enhanced scenario. Results indicate that universal adoption of, and response to, dynamic tariffs can significantly reduce peak net load (by 15%) and maximum ramping requirements (by 20%) with moderate elasticity, delivering demand response resources comparable to or exceeding current programs at all elasticity levels. Bill analysis shows that, when responding elastically to dynamic prices, most non-PV customers experience modest savings, while PV customers may see higher effective rates due to lower compensation for exports during low-price periods. Emissions analysis reveals a reduction in per-kWh emissions system-wide, with a total absolute load increase of 2% accompanied by a negligible absolute emissions increase. The study concludes that while dynamic tariffs offer substantial grid benefits, customer bill savings under modeled response behaviors may be too modest to drive widespread adoption without additional incentives or enabling technologies. Future research should model flexible loads and advanced control technologies with greater fidelity to better represent the potential opportunities of dynamic tariffs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pathways to commercial building plug and process load efficiency and control

Abstract To accomplish net-zero carbon emissions in the built environment by 2050, we must equitably decarbonize commercial buildings, including reducing plug and process loads (PPLs). PPLs are plug-in or hardwired electric and gas loads that are not associated with major building end uses like lighting and HVAC. Research shows PPL energy reduction strategies and control technologies have the potential to save energy. But even when implemented, these savings have rarely been achieved and there has not been widespread uptake in U.S. commercial buildings. We investigate why these technologies and strategies have not seen widespread adoption and identify behavior and technology pathways to increase PPL reduction in U.S. commercial buildings. We examined behaviors of commercial building stakeholders through 44 interviews and cross-referenced qualitative analysis findings with in-depth technical knowledge of existing PPL control technologies and reduction strategies. PPL control implementation must be paired with management strategies, such as occupant engagement and training, to achieve optimal savings, and best practices should be disseminated across the industry. We found that increasing access to cost and energy savings data will promote uptake of PPL control technologies and allow designers to better incorporate PPLs into building design. Improving access to funding for PPL energy efficiency projects and addressing the split-incentive problem will increase adoption of PPL efficiency and control. Code bodies should continue to include PPL monitoring and reduction measures in energy codes. Key building stakeholders, including cybersecurity and information technology teams, should be involved in PPL monitoring and reduction strategy processes for successful implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental study of airpath electrification in an opposed-piston two stroke (OP2S) engine architecture

The opposed-piston two stroke (OP2S) engine shows potential as an alternative engine architecture to the conventional four stroke engine due to its high-power density, thermal efficiency, and versatile airpath management system. Since the pistons of a two-stroke engine do not pump the air into and out of the cylinder like in a four-stroke engine, the selection of the air induction devices and airpath actuators becomes critical to optimize engine performance. Both the pumping losses and the in-cylinder combustion process can be affected by the scavenging process in a two-stroke engine. Therefore, this study compares two different airpath configurations for the same family of OP2S engines and investigates performance metrics like scavenging control, pumping work, net indicated and brake efficiencies, and engine-out emissions associated with each airpath. Data was collected on a 3.2 L, two-cylinder OP2S engine with an electrically assisted turbocharger (EAT) and a 4.9 L displacement, three-cylinder engine with a variable geometry turbocharger (VGT) and a supercharger. The experiments consisted of speed and load sweeps for both engines at the same operating conditions to compare scavenge control in both architectures. For the three-cylinder layout, the SE sweep range was much higher, and the intake pressure could be independently varied with air flowrate, thus providing more flexibility for scavenging control. The supercharger and the VGT usage was optimized based on its efficiency map and thus, this layout had lower pumping losses compared to the EAT. The two-cylinder engine had a higher overall SE as compared to the three-cylinder engine, but the intake pressure and air flowrate could not be decoupled, leading to over scavenging and increased short circuiting of fresh charge into the exhaust.

Bhatt, Ankur [Clemson University, Clemson, SC, USA↗

California Price Response Potential Study

California's energy landscape is undergoing a significant transformation, driven by the increasing integration of renewable energy sources, the increased adoption of distributed energy resources, the electrification of end-use loads, and the growing need for grid efficiency. To address these challenges, recent revisions to the State’s Load Management Standards (LMS) require all of California’s large utilities and community choice aggregators (CCAs) to offer dynamic electricity pricing options to customers by 2027. Dynamic pricing, which involves varying electricity rates based on real-time supply and demand conditions, offers a promising solution for optimizing grid operations, reducing costs, and incentivizing efficient use of grid capacity. Effective implementation of dynamic pricing requires understanding the potential impacts on customer bills, system load, and the cost-effectiveness of automation technologies. This study aims to evaluate the load response of various end-use devices to hourly dynamic prices. The end-uses studied here are space cooling, space heating, water heating, crop irrigation, pool and spa pumps, and electric vehicle (EV) charging, all for both residential and commercial applications, except for crop irrigation. In 2030, these end uses are forecasted to account for 18% of annual electricity demand in the state, but 40% of demand in the peak net load hour. By modeling possible price-responsive load dispatch algorithms and assessing the resulting impacts on both individual bills and the overall grid, we seek to inform policymakers and utilities about the potential benefits and challenges associated with dynamic pricing, and considerations for the design of dynamic pricing tariffs. Additionally, we will explore the cost effectiveness of adopting automation technologies to enable devices to respond more effectively to real-time price signals. This study considers a range of price profiles, accounting for differences across utilities and customer classes, and presents scenarios for dynamic price design via variation in the percentage of total customer electric costs that are allocated dynamically (versus constituting a fixed portion of the hourly volumetric price). We present results focused primarily on 2030, forecasting electricity prices under both low and high-cost scenarios, to inform longer-term tariff design considerations. We design tariffs by starting with 2019 prices that were calculated according to CalFUSE guidance (CPUC, 2022) and that have been used in recent studies; these prices are all-in volumetric rates that vary by utility and are revenue-neutral to each customer class. They are developed by considering six electricity cost components that are allocated hourly based on system load indicators (gross and net load, and wholesale prices). These prices are forecasted to 2030 for low and high cost scenarios, considering recent trends in total electricity costs with and without years of substantial wildfire mitigation investments. These tariffs, which allocate all costs on an hourly basis, are considered our “Full” dynamic tariff design scenario, while two additional scenarios explore allocating a portion of costs as a flat volumetric charge: the “Medium” scenario allocates 50% of revenue dynamically (and keeps 50% flat), while the “Mild” scenario allocates 20% of revenue dynamically. The 20% dynamic allocation on the Mild scenario aims to represent a case where only the marginal operating costs of the grid are included in the dynamic price.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Stochastic Look-Ahead Commitment: A Case Study in MISO

This paper introduces the Stochastic Look Ahead Commitment (SLAC) software prototyped and tested for the Midcontinent Independent System Operator (MISO) look ahead commitment process. SLAC can incorporate hundreds of wind, load, and net scheduled interchange (NSI) uncertainty scenarios. It uses a progressive hedging method to solve a novel two-stage stochastic unit commitment. The first stage commitment decisions, made only for those generators whose decision to commit or not in each time period cannot be deferred, can cover the uncertainties within the next three hours. The second stage includes both the dispatch for each of the scenarios and the commitment decisions that can be deferred. Study results on 15 MISO production days show that SLAC may bring economic and reliability benefits under uncertainty.

MATHEMATICS AND COMPUTING↗