Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “negative transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Polarity Asymmetries in Rocket‐Triggered Lightning

Abstract The dissonant development of positive and negative lightning leaders is a central question in atmospheric electricity. It is also the likely root cause of other reported asymmetries between positive and negative lightning flashes, including the ones regarding: stroke multiplicity, recoil activity, leader velocities, and emission of energetic radiation. In an effort to contrast lightning leaders of different polarities, we highlight the staggering differences between two rocket‐triggered lightning flashes. The flash beginning with upward positive leaders exhibits an initial continuous current stage followed by multiple sequences of dart leaders and return strokes. On the other, in its opposite‐polarity counterpart, the upward development of negative leaders is by itself the entire flash. As a result, the flash with negative leaders is faster, briefer, transfers less charge to the ground, has lower currents, and smaller spatial extent. We conclude by presenting a discussion on the three fundamental leader propagation modes.

54 ENVIRONMENTAL SCIENCES↗

Corn grown on dredged sediments alters rat behavior in the elevated plus maze via the gut mycobiome

The use of marginal lands for growing food has increased worldwide. Many of these lands are supplemented with soil amendments to enhance their productivity, but they may also introduce contaminants depending on their origin. The use of sediments dredged from commercial waterways as a soil amendment has increased in recent years. However, there is significant concern regarding their potential to negatively affect public health by transferring contaminants, like metals, to the food supply. This study examined the behavior, microbiome and physiology of rats fed corn grown on dredged sediments with rats fed commercial feed corn and related those metrics to kernel metal content. Metal content did not differ between kernels grown on dredged sediments and feed corn for most metals except iron which was greater in commercial feed corn. Although there is some variability by animal response, animals fed corn grown on dredged sediments had a gut microbial community that generally promoted anxiety-like behavior while animals fed feed corn had a gut microbial community that promoted a more typical response. These findings suggest the effect of corn grown on dredged sediments on public health is complex and highlights the need for further investigation.

Rua, Megan [Wright State University, Dayton, OH]↗

The Use of Pristine and Intercalated Graphite Fiber Composites as Buss Bars in Lead-Acid Batteries

This study was conducted as a part of the Firefly Energy Space Act Agreement project to investigate the possible use of composite materials in lead acid batteries. Specifically, it examined the use of intercalated graphite composites as buss bars. Currently, buss bars of these batteries are made of lead, a material that is problematic for several reasons. Over time, the lead is subject to both corrosion at the positive plate and sulfation at the negative plate, resulting in decreased battery life. In addition, the weight and size of the lead buss bars make for a heavy and cumbersome battery that is undesirable. Functionality and practicality of lead buss bars is adequate at best; consequently, investigation of more efficient composite materials would be advantageous. Practically speaking, graphite composites have a low density that is nearly one fourth that of its lead counterpart. A battery made of less dense materials would be more attractive to the consumer and the producer because it would be light and convenient. More importantly, low weight would be especially beneficial because it would result in greater overall power density of the battery. In addition to power density, use of graphite composite materials can also increase the life of the battery. From a functional standpoint, corrosion and sulfation at the positive and negative plates are major obstacles when considering how to extend battery life. Neither of these reactions are a factor when graphite composites replace lead parts because graphite is chemically non-reactive with the electrolyte within the battery. Without the problem of corrosion or sulfation, battery life expectancy can be almost doubled. The replacement of lead battery parts with composite materials is also more environmentally favorable because of easy disposal of organic materials. For this study, both pristine and bromine intercalated single-ply graphite fiber composites were created. The composites were fabricated in such a way as to facilitate their use in a 3" x 1/2" buss bar test cell. The prime objective of this investigation was to examine the effectiveness of a variety of graphite composite materials to act as buss bars and carry the current to and from the positive and negative battery plates. This energy transfer can be maximized by use of materials with high conductivity to minimize the buss resistance. Electrical conductivity of composites was measured using both a contactless eddy current probe and a four point measurement. In addition, the stability of these materials at battery-use conditions was characterized.

Opaluch, Amanda M.↗

Can Charge Transfer Across C─H⋅⋅⋅O Hydrogen Bonds Stabilize Oil Droplets in Water?

Oil-water emulsions resist aggregation due to the presence of negative charges at their surface that leads to mutual repulsion between droplets, but the molecular origin of oil charge is currently under debate. Although much evidence has suggested that ionic species must accumulate at the interface, an alternative perspective attributes the negative charge on the oil droplet to charge transfer of electron density from water to oil molecules. Although the charge transfer mechanism is consistent with the correct sign of oil charge, it is just as important to provide good estimates of the charge magnitude to explain emulsion stability and electrophoresis experiments. Here, we show using energy decomposition analysis that the amount of net flow of charge from water to oil is negligibly small due to nearly equal forward and backward charge transfer through weak oil-water interactions, such that oil droplets would be unstable and coalesce, contrary to experiment. The lack of charge transfer also explains why vibrational sum frequency scattering reports a blue shift in the oil C-H frequency when forming emulsions with water, which arises from Pauli repulsion due to localized confinement at the interface. Finally, unlike ions, neither charge transfer nor dynamic polarization can produce a finite conductivity needed to couple to electric fields that would explain electrophoretic mobility.

Zhao, Ruoqi↗

Negative-ion formation in the explosives RDX, PETN, and TNT using the Reversal Electron Attachment Detection (READ) technique

In the search for high sensitivity and direct atmospheric sampling of trace species, techniques have been developed such as atmospheric-sampling, glow-discharge ionization (ASGDI), corona discharge, atmospheric pressure ionization (API), electron-capture detection (ECD), and negative-ion chemical ionization (NICI) that are capable of detecting parts-per-billion to parts-per-trillion concentrations of trace species. These techniques are based on positive- or negative-ion formation via charge-transfer to the target, or electron capture under multiple-collision conditions in a Maxwellian distribution of electron energies at the source temperature. One drawback of the high-pressure, corona- or glow-discharge devices is that they are susceptible to interferences either through indistinguishable product masses, or through undesired ion-molecule reactions. The ASGDI technique is relatively immune from such interferences, since at target concentrations of less than 1 ppm the majority of negative ions arises via electron capture rather than through ion-molecule chemistry. A drawback of the conventional ECD, and possibly of the ASGDI, is that they exhibit vanishingly small densities of electrons with energies in the range 0-10 millielectron volts (meV), as can be seen from a typical Maxwellian electron energy distribution function at T = 300 K. Slowing the electrons to these subthermal (less than 10 meV) energies is crucial, since the cross section for attachment of several large classes of molecules is known to increase to values larger than 10(exp -12) sq cm at near-zero electron energies. In the limit of zero energy these cross sections are predicted to diverge as epsilon(exp -1/2), where epsilon is the electron energy. In order to provide a better 'match' between the electron energy distribution function and attachment cross section, a new concept of attachment in an electrostatic mirror was developed. In this scheme, electrons are brought to a momentary halt by reversing their direction with electrostatic fields. At this turning point the electrons have zero or near-zero energy. A beam of target molecules is introduced, and the resultant negative ions extracted. This basic idea has been recently improved to allow for better reversal geometry, higher electron currents, lower backgrounds, and increased negative-ion extraction efficiency. We present herein application of the so-called reversal electron attachment detector (READ) to the study of negative-ion formation in the explosives molecules RDX, PETN, and TNT under single-collision conditions.

Chutijian, Ara↗

EVSE Characterization: V2G EVSE Comparison

As part of the U.S. Department of Energy EVs@Scale consortium Next-Generation Profiles project, results and analysis from the characterization of high-power conductive and wireless charging infrastructure are presented. This characterization is conducted over a wide range of direct current (DC) current and DC voltage operation for nominal test conditions and off-nominal test conditions. Test plans and procedures were developed to define the test configurations and requirements, measurement parameters, and test procedures used throughout testing. Results from a 2024 study conducted on electric vehicle supply equipment (EVSE) characterization by the Idaho National Laboratory (INL) include two bi-directional vehicle-to-grid (V2G) capable EVSEs. These EVSE are referred to as V2G-EVSE9 and V2G-EVSE10. Laboratory testing is conducted at nominal test conditions to characterize the power transfer capabilities, efficiency, power factor, and other power quality metrics of the two DC EVSEs capable of V2G bi-directional power transfer. Results from testing show the performance is consistent for V2G-EVSE9 and V2G-EVSE10 when comparing charging to discharging performance, except for V2G-EVSE10 for power transfer when operating above 70% of the rated DC current. V2G-EVSE10 efficiency is >98% while charging and <91% while discharging at the same operating conditions, near maximum-rated current, at 300VDC. In contrast, V2G-EVSE9 results are consistent for charging and discharging. This EVSE is nearly 96% efficient while charging or discharging when operating over 50% of rated AC power. V2G EVSE performance is also characterized during off-nominal AC grid conditions involving AC voltage deviation (426 VAC to 518 VAC), AC frequency deviation of +2% (58.8 Hz to 61.2 Hz), and AC voltage harmonics injection. Many test conditions have little-to-no impact on performance characteristics of the two EVSEs; however, there are a few notable findings with significant power transfer capability impacts. AC voltage harmonics injection resulted in negative impacts on power quality attributes for both EVSEs, but with no impact on power transfer capability. Off-nominal AC voltage and frequency conditions resulted in unstable or lack of power transfer capability for both EVSEs. V2G-EVSE9 is unable to transfer power when AC voltage is >300V L-N. V2G-EVSE10 is unable to transfer power when AC frequency deviation exceeds +0.8%. V2G energy management system transient response and latency are quantified during laboratory testing. V2G-EVSE9 and V2G-EVSE10 utilize cloud-based V2G energy management systems that command the power transfer level between the EVSE and EV. The latency and response characteristics of the entire systems (web-based user interface, V2G energy management system, cellular communications, and EVSE response) are quantified through laboratory testing for V2G-EVSE9 and V2G-EVSE10. V2G-EVSE9 latency ranges from 0.8 to 1.8 seconds, whereas V2G-EVSE10 latency ranges from 3.4 to 8.8 seconds. The ramp rate to a change in power transfer request also differs between the two EVSEs. V2G-EVSE10 ramp rate ranges from 50% to -250% of rated AC power per second, whereas V2G-EVSE9 rate ranges from 95% to -95% of rated AC power per second. At the highest rate of change in power transfer, V2G-EVSE10 can change from full charge power to full discharge power in less than one second. The V2G EVSE characterization presented in this report provides valuable insights and results for use by numerous entities. This includes modeling and simulation organizations, decision makers, fleet planning, industry stakeholders, and many others involved with the development and deployment of electrified transportation technologies. Additional high-power DC chargers, bidirectional chargers, and inductive power transfer EVSE characterization results are anticipated from additional EVSE brands and models, which will be detailed in future publications in support of the U.S. Department of Energy EVs@Scale consortium Next-Gen Profiles project.

25 ENERGY STORAGE↗

Electron-Induced Proton Transfer

The pathway of activationless proton transfer induced by an electron-transfer reaction is studied theoretically. Long-range electron transfer produces highly nonequilibrium medium polarization that can drive proton transfer through an activationless transition during the process of thermalization, dynamically altering the screening of the electron–proton Coulomb interaction by the medium. The cross electron–proton reorganization energy is the main energy parameter of the theory, which exceeds in magnitude the proton-transfer reorganization energy roughly by the ratio of the electron-transfer to proton-transfer distance. This parameter, which can be either positive or negative, is related to the difference in pK a values in two electron-transfer states. The relaxation time of the medium is on the (sub)picosecond time scale, which establishes the characteristic time for activationless proton transfer. Microscopic calculations predict substantial retardation of the collective relaxation dynamics compared to the continuum estimates due to the phenomenology analogous to de Gennes narrowing. As a result, nonequilibrium medium configuration promoting proton transfer can be induced by either thermal or photoinduced charge transfer.

14 SOLAR ENERGY↗

The Evaluation of Methicillin Resistance in Staphylococcus aboard the International Space Station

The International Space Station (ISS) represents a semi-closed environment with a high level of crewmember interaction. As community-acquired methicillin-resistant Staphylococcus aureus (MRSA) has emerged as a health concern in environments with susceptible hosts in close proximity, an evaluation of isolates of clinical and environmental Staphylococcus aureus and coagulase negative Staphylococcus was performed to determine if this trend was also present in astronauts aboard ISS or the space station itself. Rep-PCR fingerprinting analysis of archived ISS isolates confirmed our earlier studies indicating a transfer of S. aureus between crewmembers. In addition, this fingerprinting also indicated a transfer between crewmembers and their environment. While a variety of S. aureus were identified from both the crewmembers and the environment, phenotypic evaluations indicated minimal methicillin resistance. However, positive results for the Penicillin Binding Protein, indicative of the presence of the mecA gene, were detected in multiple isolates of archived Staphylococcus epidermidis and Staphylococcus haemolyticus. Phenotypic analysis of these isolates confirmed their resistance to methicillin. While MRSA has not been isolated aboard ISS, the potential exists for the transfer of the gene, mecA, from coagulase negative environmental Staphylococcus to S. aureus creating MRSA strains. This study suggests the need to expand environmental monitoring aboard long duration exploration spacecraft to include antibiotic resistance profiling.

Ott, C. M.↗

Demonstration and Validation of Additively Manufactured Intensified Device for Enhanced Carbon Capture

In FY 2018 and 2019, ORNL personnel designed, prototyped, characterized, and tested the enhancement of amine-based carbon capture using additively manufactured intensified devices, i.e., devices combining multiple thermodynamic and kinetic processes into one unit operation. State of the art scrubbing technology often employs inter-stage cooling which requires multiple stages of single-purpose unit operations, leading to larger equipment size, higher capital cost, and sometimes less than optimal operating conditions for each piece of equipment. It was proposed that integrating multiple thermodynamic and kinetic operations into one unit could mitigate or negate these drawbacks. Heat and mass transfer studies demonstrated that an additively manufactured intensified device could significantly improve capture efficiency at bench scale. This project is a continuation of FEAA130 and aims at (1) demonstration and validation of enhanced CO 2 capture with 3D printed intensified devices (i.e., mass exchanger packing with internal cooling channels), for low-aqueous-solvent (LAS) based capture at the ORNL-constructed laboratory-scale (4.5-feet tall) column, namely Column A, with built-in cooling and (2) computational scoping on the conceptual design of a flexible and modular larger column, namely Column B, at ORNL for further demonstration of enhanced capture for aqueous solvent. To execute this multi-faceted project scope, an integrated project team from ORNL’s Manufacturing Science Division is tasked with applying capabilities in computational fluid dynamics (CFD), additive manufacturing, and absorber-scale demonstration/validation experiments.

42 ENGINEERING↗

Effects of solution mass transport on the ECC ozonesonde background current

Measurement of the mass transport rate constant for the electrochemical concentration cell in an ozonesonde as a function of the pressure is reported. The investigation was performed to accurately model the residual current present in the ECC cell in the absence of ozone. The convective mass transport for two sondes were determined while maintaining a sufficiently negative cathodic potential to eliminate electron transfer at the cathode surface. A sonde was placed in a bell jar and subjected to varying pressure levels. When the background current was kept below 0.1 microamp and pressure was from 100-1000 mb, the necessary correction term for the pressure was independent of pressure. However, below 100 mb, a logarithmic decrease in the background current with pressure is expected. Present practices, involving a sensitivity to oxygen, are calculated to result in overestimation of the total ozone between 1000-10 mb by 0.0096 atm-cm with a background current of 0.1 microamp at 1000 mb.

Thornton, D. C.↗

Protecting the GEO Environment: Policies and Practices

The geosynchronous orbital regime has long been recognized as a unique space resource, dictating special measures to ensure its continuing use for future generations. During the past 20 years a variety of national and international policies have been developed to preserve this environment. A review of current practices involving the deployment and disposal of geosynchronous spacecraft, associated upper stages and apogee kick motors, and geosynchronous orbit transfer objects indicates both positive and negative trends. Most spacecraft operators are indeed performing end-of-mission maneuvers, but the boost altitudes normally fall short of policy guidelines. Russia, a major operator in geosynchronous orbit, maneuvers only 1 in 3 spacecraft out of the region, while China has never refired a spacecraft above GEO. The viability of voluntary protection measures for this regime depends upon the responsible actions of the aerospace community as a whole.

Johnson, Nicholas L.↗

THEMIS Observations of a Transient Event at the Magnetopause

This study focuses on Time History of Events and Macroscale Interactions During Substorms (THEMIS) observations of a long \duration transient event in the vicinity of the dayside magnetopause at approx.15:34 UT on 18 July 2008 that was characterized by features typical of a magnetospheric flux transfer event (FTE): a bipolar negative-positive 5-7 nT signature in the Bn component, a positive monopolar variation in the Bl and Bm components, a approx.5-7 nT enhancement in the total magnetic field strength, and a transient density and flow enhancement. The interplanetary magnetic field (IMF) was mostly radial and disturbed during the intervals studied; that is, it was favorable for the repeated formation, disappearance and reformation of the foreshock just upstream from the subsolar bow shock. We show that varying IMF directions and solar wind pressures created significant effects that caused the compressions of the magnetosphere and the bow shock and magnetopause motions and triggered the transient event. Global signatures of magnetic impulse events (MIEs) in ground magnetograms during the period suggest a widespread pressure pulse instead of a localized FTE as the cause of the event in the magnetosphere. The directions of propagation and the flow patterns associated with the event also suggest an interpretation in terms of pressure pulses.

Korotova, G. I.↗

Biomedical technical transfer. Applications of NASA science and technology

Lower body negative pressure testing in cardiac patients has been completed as well as the design and construction of a new leg negative unit for evaluating heart patients. This technology is based on NASA research, using vacuum chambers to stress the cardiovascular system during space flight. Additional laboratory tests of an intracranial pressure transducer, have been conducted. Three new biomedical problems to which NASA technology is applicable are also identified. These are: a communication device for the speech impaired, the NASA development liquid-cooled garment, and miniature force transducers for heart research.

Source record↗

Architected stamps for liquid transfer printing

The present invention relates to architected stamps having beneficial printing properties. In particular, negative Poisson ratio structures and/or porous reservoirs can be employed to control fluid dynamics and to provide metered ink transfer.

Kaehr, Bryan James↗

Deciphering Distinct Overpotential-Dependent Pathways for Electrochemical CO 2 Reduction Catalyzed by an Iron–Terpyridine Complex

[Fe(tpyPY2Me)] 2+ ([Fe] 2+ ) is a homogeneous electrocatalyst for converting CO 2 into CO featuring low overpotentials of <100 mV, near-unity selectivity, and high activity with turnover frequencies faster than 100 000 s -1 . To identify the origins of its exceptional performance and inform future catalyst design, we report a combined computational and experimental study that establishes two distinct mechanistic pathways for electrochemical CO 2 reduction catalyzed by [Fe] 2+ as a function of applied overpotential. Electrochemical data shows the formation of two catalytic regimes at low (η TOF/2 of 160 mV) and high (η TOF/2 of 590 mV) overpotential plateaus. We propose that at low overpotentials [Fe] 2+ undergoes a two-electron reduction, two-proton-transfer mechanism (electrochemical-electrochemical-chemical-chemical, EECC), where turnover occurs through the dicationic iron complex, [Fe] 2+ . Computational analysis supports the importance of the singlet ground-state electronic structure for CO 2 binding and that the rate-limiting step is the second protonation in this low-overpotential regime. When more negative potentials are applied, an additional electron-transfer event occurs through either a stepwise or proton-coupled electron-transfer (PCET) pathway, enabling catalytic turnover from the monocationic iron complex ([Fe] + ) via an electrochemical-chemical-electrochemical-chemical (ECEC) mechanism. Comparison of experimental kinetic data obtained from variable controlled potential electrolysis (CPE) experiments with direct product detection with calculated rates obtained from the energetic span model supports the PCET pathway as the most likely mechanism. Moreover, we build upon this mechanistic understanding to propose the design of an improved ligand framework that is predicted to stabilize the key transition states identified in our study and explore their electronic structures using an energy decomposition analysis. Finally, taken together, this work highlights the value of synergistic computational/experimental approaches to decipher mechanisms of new electrocatalysts and direct the rational design of improved platforms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Longitudinal variability of methane and ammonia bands on Jupiter

Results of a quantitative study of the longitudinal variations of methane and ammonia absorption on Jupiter are presented. A total of 78 high signal-to-noise ratio photoelectric spectra in the range 6000 to 6600 A were obtained on two consecutive nights, with complete longitudinal equatorial coverage each night through 9-min exposures covering a total of over 9 h. Analysis of the equivalent widths of the CH4 6190 A and NH3 6450 A absorption bands by means of a blind, automated, self-consistent method of continuum determination reveals large equivalent widths in both bands near longitudes of 35 and 340 deg and small equivalent widths near 150 deg, with a high degree of correlation between the equivalent widths of the bands. Continuum molecular absorption is found to be slightly negatively correlated with band equivalent widths. Radiative transfer calculations based on the model of Sato and Hansen (1979) using a doubling and adding technique indicate that the observed longitudinal variables of equivalent widths and continuum reflectivity are the results of longitudinal variations in ammonia cloud altitude.

Cochran, W. D.↗

Water-enhanced bifunctional metal-acid catalyst for C=C bond hydrogenation

Water-assisted proton shuttling can promote hydrogenation of polar functional groups, and it is generally believed that such an effect can be hardly applied to hydrogenation of C═C bonds due to the latter's weak interaction with water. Here, we report density functional theory calculations and metadynamics simulations, through which we show a dynamic bifunctional metal–acid site that can be transformed, when interacting with water, into an active configuration for unexpected water-enhanced proton shuttling to C═C bonds. In particular, we investigated B(OH)3 anchored to a Ni catalyst for hydrogenation of cyclohexene in an organic solvent, which showed in experiments an increased rate by 100 times when adding a small amount of water. Metadynamics simulations suggest that a B(OH)3–H2O cluster can form on Ni(111), which promotes the proton transfer in the first hydrogenation step, while the second hydrogenation is still driven by metal-mediated direct H-transfer. The recovery process of B(OH)3–H2O also involves a proton shuttling step. We find that the boric species on the surface serves as an electron reservoir and carries the negative charge to balance the positive charge in the proton transfer steps. This work thus provides fundamental insights into this dynamic transformation process of the metal–acid interface, which can in principle be applied to many other bifunctional systems for hydrogenating non-polar unsaturated groups by engineering the interfacial charge separation.

Sun, Shoutian↗

Charge Transfer Process During Collision of Riming Graupel Pellet with Small Ice Crystals within a Thundercloud

A charge transfer process during the collision of a riming graupel pellet and an ice-crystal at low temperature is proposed. During riming, the surface structure of graupel deviates from perfect crystalline structure. A concept of quasi-solid layer (QSL) formation on the surface is introduced. This QSL contains defects formed during riming. In absence of impurities, positively charged X-defect abundance is considered in the outer layer. These defects are assumed to be the charge carriers during the charge transfer process. Some part of the QSL is stripped off by the colliding ice crystals, which thereby gain some positive charge, leaving the graupel pellet negatively charged. With the proposed model, fC to pC of charge transfer is observed per collision. A transition temperature between -10 C to -15 C is also noted beyond which the QSL concept does not hold. This transition temperature is dependent on the bulk liquid water content of the cloud.

Datta, Saswati↗