Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiwire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Soft X-ray astronomy proportional counter electronics

The X-ray multiwire proportional counter is designed to measure cosmic X-ray fluxes at sounding rocket altitudes in the energy range of 0.1 to 10 keV. Four instruments will be launched in a Black Brant 4 rocket employing different combinations of detector windows and gas. The detector is constructed with two layers of twelve cells. A columnator is mounted on the face of one layer whose cells are wired together alternately to form two main detector sections. The electronics and gas regulation systems are mounted on the face of the second layer whose cells are wired together to form one anticoincidence detector section. Normally X-rays will have short ionization paths in only one of the main detector cells at a time and won't enter the anticoincidence detector cells. To distinguish between X-rays and charged particles, the instrument includes a coincidence discriminator, an anticoincidence discriminator, and a pulse rise time discriminator.

Gardner, W. R.↗

Planetary X ray experiment

Design studies for an X-ray experiment using solid state detectors and for an experiment using a proportional counter for investigating Jovian and Saturnian magnetospheres are reported. Background counting rates through the forward aperture and leakage fluxes are discussed for each design. It is concluded that the best choice of instrument appears to have following the characteristics: (1) two separate multiwire proportional counters for redundancy; (2) passive collimation to restrict the field to about 5 deg, wiregrid modulation collimation to about 0.1 deg angular resolution; (3) no active shielding system around the counter body; and (4) light passive shielding around any portion of the counter body exposed to space to absorb most of the cosmic X-ray background.

Anderson, K. A.↗

Remote analysis of planetary soils: X-ray diffractometer development

A system is described suitable for remote low power mineralogical analysis of lunar, planetary, or asteroid soils. It includes an X-ray diffractometer, fluorescence spectrometer, and sample preparation system. A one Curie Fe-55 source provides a monochromatic X-ray beam of 5.9 keV. Seeman-Bohlin or focusing geometry is employed in the camera, allowing peak detection to proceed simultaneously at all angles and obviating the need for moving parts. The detector system is an array of 500-600 proportional counters with a wire-spacing of 1 mm. An electronics unit comprising preamplifier, postamplifier, window discriminators, and storage flipflops requiring only 3.5 milliwatts was designed and tested. Total instrument power is less than 5 watts. Powder diffraction patterns using a flat breadboard multiwire counter were recorded.

Gregory, J. C.↗

A new magnetic spectrometer system for cosmic ray studies

The balloon flight prototype or a cosmic ray superconducting magnet experiment designed for operation on the Space Shuttle is described. The physical and operating parameters of the scintillation, Cerenkov, emulsion and multiwire proportional counters used in the system for charge and rigidity measurements is given as well as the on-board data handling procedures.

Golden, R. L.↗

Measurements of cosmic ray trajectories with a proportional counter hodoscope

A 50 by 50 cm, 8-layer multiwire proportional counter hodoscope has been developed for performing trajectory measurements in a large geometrical factor cosmic ray experiment. The hodoscope has a nominal position accuracy of 0.5 cm and a 1-deg angular accuracy. Data obtained from a balloon exposure show tracks of heavy cosmic rays are efficiently recovered from the copious triggers due to secondary electrons through the use of two discriminators on each wire. The spatial distribution of counts produced by secondary electrons from the iron group nuclei is compared with calculations of energy deposition from the secondaries.

Parnell, T. A.↗

The efficient identification of relativistic particles by transition radiation

A system of transition radiation detectors has been constructed and exposed to beams of electrons and pions in the energy range of 3 to 15 GeV at SLAC. Transition radiation was generated in a variety of stacks of mylar foils (radiators), and its intensity was detected with 7 multiwire proportional chambers. The raw data demonstrate a good separation between electron and pion induced signals. A more detailed analysis shows that a very efficient identification of individual particles is possible. Typically, a detection efficiency for electrons above 90%, combined with a pion-electron discrimination ratio of .001, has been achieved. Some conclusions with respect to the design of a practical detector for relativistic particles are drawn.

Cherry, M. L.↗

Atmospheric X-ray emission experiment for shuttle

An experiment designed to measure the spatial, temporal, and energy distribution of X-ray aurorae produced by precipitating electrons, is presented. The experiment will provide vital data on solar-terrestrial relationships that may lead to defining the transfer mechanism that causes certain terrestrial weather events and climatological behavior. An instrument concept is discussed, and is based on a spatially sensitive multiwire proportional counter, combined with collimators to produce X-ray images of the aurorae. An instrument pointing system, on which the counter can be mounted, will provide the required altitude control, and can be operated by a Spacelab payload specialist for full control over its observing and data taking modes.

Goldberg, R. A.↗

One-dimensional focusing X-ray telescope for stellar X-ray astronomy

A one-dimensional X-ray telescope of the Kirkpatrick-Baez design is described. The instrument consists of a grazing-incidence X-ray telescope and a multiwire proportional counter. The optics were provided with a gold reflecting surface to yield an energy response from below 0.25 to above 4.0 keV. The angular resolution of the system is 6 min by 9.5 deg over a 1.1 deg by 9.5 deg field of view.

Helava, H.↗

Atmospheric X-ray Emission Experiment for Shuttle

The Atmospheric X-ray Emission Experiment (AXEE) for Shuttle is designed to measure the spatial, temporal, and energy distribution of X-ray aurorae produced by precipitating electrons. It will provide vital data on solar-terrestrial relationships that may lead to defining the transfer mechanism that causes certain terrestrial weather events and climatological behavior. The instrument concept is based on a spatially sensitive multiwire proportional counter, combined with collimators to produce X-ray images of the aurorae. It will be mounted on an instrument pointing system to provide the required attitude control and is operated by the Spacelab payload specialist who has full control over its observing and data taking modes.

Goldberg, R. A.↗

An experiment to measure cosmic ray 2H and 3He in the 4-10 GV range

It is known that the mean matter traversed by cosmic rays, X, can be obtained from the observed ratio of the flux of daughter nuclei to that of the parent nuclei provided X is much less than the attenuation mean free of the daughter nuclei. This condition is well satisfied in the case of 2H and 3He. We propose to measure the 2H/1H and 3He/4He ratios, using a multiwire proportional counter array and a superconducting magnet to measure the rigidity, and a set of aerogel Cerenkov counters to measure the velocity, thus yielding the mass of the particle. Results of a Monte-Carlo calculation based on actual experimental conditions are presented to show the resolution of the instrument. The area solid angle of the telescope is 90 sq cm sr with an average maximum detectable momentum of 140 GV.

Badhwar, G. D.↗

Design of a transition radiation detector for cosmic rays

Transition radiation detectors consisting of sandwiches of plastic foam radiators and multiwire proportional chambers can be used to identify cosmic ray particles with energies gamma ? E/mc-squared is greater than 10 to the 3rd and to measure their energy in the region gamma is roughly equal to 10 to the 3rd

Hartmann, G.↗

Nuclear Science Symposium, 4th, and Nuclear Power Systems Symposium, 9th, San Francisco, Calif., October 19-21, 1977, Proceedings

Consideration is given to the following types of high energy physics instrumentation: drift chambers, multiwire proportional chambers, calorimeters, optical detectors, ionization and scintillation detectors, solid state detectors, and electronic and digital subsystems. Attention is also paid to reactor instrumentation, nuclear medicine instrumentation, data acquisition systems for nuclear instrumentation, microprocessor applications in nuclear science, environmental instrumentation, control and instrumentation of nuclear power generating stations, and radiation monitoring. Papers are also presented on instrumentation for the High Energy Astronomy Observatory.

Source record↗

Nuclear Science Symposium, 25th, and Symposium on Nuclear Power Systems, 10th, Washington, D.C., October 18-20, 1978, Proceedings

Detectors of various types are discussed, taking into account drift chambers, calorimetry, multiwire proportional chambers, signal processing, the use of semiconductors, and photo/optical applications. Circuits are considered along with instrumentation for space, nuclear medicine instrumentation, data acquisition and systems, environmental instrumentation, reactor instrumentation, and nuclear power systems. Attention is given to a new approach to high accuracy gaseous detectors, the current status of electron mobility and free-ion yield in high mobility liquids, a digital drift chamber digitizer system, the stability of oxides in high purity germanium, the quadrant photomultiplier, and the theory of imaging with a very limited number of projections.

Source record↗

Low-cost, high-efficiency silicon by heat exchanger method and fixed abrasive slicing technique

The paper describes the heat exchanger method (HEM) for growing silicon crystals. The problem of ingot cracking was solved by using a graded structure silica crucible, and vacuum processing eliminated expensive high-purity argon. Solar cells fabricated from HEM silicon demonstrated conversion efficiencies up to 15% (AM1) at low cost, using square cross-section, single crystal silicon. A modified multiblade slurry machine was adapted for multiwire fixed abrasive slicing of silicon which uses a diamond attached to wires; this method provides a conversion ratio of 1.08 sq m of wafer per kg of silicon ingot, and produces wafers free of edge chipping with a surface damage of 3-5 microns.

Khattak, C. P.↗

The mean-mass of cosmic-ray Ne, Mg and Si at 1.0 GeV/amu

The results of a new measurement of the mean mass of the cosmic-ray nuclei Ne, Mg and Si at an energy of 1.0 GeV/amu are presented. The method employs the filtering effect of the geomagnetic field on the incoming cosmic-ray fluxes. The results were obtained in two balloon flights from Muskogee, Oklahoma (vertical cutoff rigidity = 3.4 GV) yielding an exposure factor of 20 sq m srh. The instrument consists of a counter telescope containing 2 plastic scintillators, 2 Cerenkov radiators and a multiwire proportional chamber hodoscope for trajectory identification.

Dwyer, R.↗