Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiple faults”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Forward and inverse modeling of fault transmissibility in subsurface flows

Characterizing physical properties of faults, such as their transmissibility, is crucial for performing predictive numerical simulation of subsurface flows, such as those encountered in petroleum engineering and remediation of subsurface contamination. Here, this paper provides a complete investigation of the inverse problem for fault transmissibility in subsurface flow models, under appropriate assumptions on fault structure. In particular, the following aspects are considered: 1) fault modeling and well-posedness of the forward problem; 2) finite element (FEM) discretizations of the forward problem and their rigorous a priori convergence analysis; 3) Well-posedness of the Bayesian inverse problem, FEM discretization of the infinite dimensional Bayesian inverse formulation, and its rigorous a priori analysis. Moreover, computation of the maximum a posteriori (MAP) point via fast inexact Newton-conjugate gradient optimization and a Laplace approximation of the Bayesian posterior are also presented. Numerical results illustrate the use of the proposed fault model in forward and inverse problems for subsurface flows in two dimensional domains with multiple faults.

97 MATHEMATICS AND COMPUTING↗

An Innovative Fault Impact Analysis Framework for Enhancing Building Operations

The main goal of this paper is to rank building faults based on their impacts on the building energy penalty and occupant thermal comfort penalty considering multiple faults and fault occurrence rates. A fault impact analysis framework is created by incorporating the fault model library with the whole building energy performance simulation (e.g., EnergyPlus used in this study). The fault occurrence rate is introduced as a 'meta' parameter in the simulation. This framework involves three essential aspects of conducting a fault impact analysis: fault constructing, fault simulation, and fault impact analysis. A parametric sensitivity analysis was used to determine and rank the criticality of the faults considering the fault concurrence frequency, by using the deep-learning based response surface model (i.e., the multi-layer perceptron regression). The proposed fault analysis framework with ranking was tested and demonstrated for the DOE's prototype medium-sized office in four different climate zones (i.e., Atlanta, Chicago, Miami, and San Francisco) with 12,000 EnergyPlus fault simulations. A total of 129 fault modes from 41 groups of fault models were simulated for the medium-sized office case. The results demonstrate the proposed framework is robust and scalable for the fault impact analysis. The top critical fault for the medium-sized office is the fault of HVAC-Left-ON for the packaged rooftop unit, regarding the site energy, source energy, and HVAC energy. Excluding the fault of HVAC-Left-ON, the top critical faults vary significantly among the four climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal well placement and brine extraction for pressure management during CO 2 sequestration

Large-scale pressure increases resulting from carbon dioxide (CO 2 ) injection in the subsurface can potentially impact caprock integrity, induce reactivation of critically stressed faults, and drive CO 2 or brine through conductive features into shallow groundwater. Pressure management involving the extraction of native fluids from storage formations can be used to reduce such pressure increases. However, dealing with large volumes of extracted brine can be technically challenging and expensive. Selection of optimal well locations and pumping rates are critical for maximizing CO 2 storage and minimizing brine extraction during geologic CO 2 sequestration (GCS). Robust and efficient computerized algorithms combining reservoir models and optimization methods are needed to make proper decisions on well placement and pumping rates. This work presents a constrained differential evolution (CDE) algorithm for solving global optimization problems involving pressure management of GCS projects. Application of the CDE optimization methodology was demonstrated for a hypothetical CO 2 storage scenario in a deep sandstone reservoir in the Southern San Joaquin Basin in California, USA. Industrial-scale storage of CO 2 would generate significant pressure buildup in this formation, which in turn would raise concerns about induced seismicity due to presence of multiple faults surrounding the injection site. Through the CDE optimization algorithm coupled to a vertically-averaged reservoir simulator, we successfully estimated optimal solutions for brine extraction wells in the reservoir that would limit the local pressure along the faults to a prescribed threshold. Multiple realizations of the reservoir permeability field were created to understand the impact of reservoir heterogeneity on optimization results. Our results indicate that the reservoir slope and heterogeneity have significant impact on optimum extraction rates. Reservoir heterogeneity is also a significant factor for extraction well locations, suggesting that in practice decisions about extraction well placement through optimization should be made at later project stages when data from a few years of CO 2 injection have allowed iterative updating and refining of the reservoir forward models. Although the study focused on optimization of brine extraction, the CDE optimization methodology presented in this paper has also potential to solve other complex optimization problems related to GCS, such as increasing storage efficiency by enhancing injectivity and capillary and dissolution trapping.

58 GEOSCIENCES↗

Experience Report for WOPR

One of the purposes of the SQA effort at LLNL is to attempt to determine the 'goodness' of the research codes used for various scientific applications. Typically these are two and three dimensional multi-physics simulation and modeling codes. These legacy research codes are used for applciations such as atmospheric dispersion modeling and analysis and prediction of the performance of engineered systems. These codes are continually subjected to automated regression test suites consisting of verified and validated expected results. Code is managed in repositories. Experience level of developers is high in the knowledge domain, platforms, and languages used. Code size of the multi-physics code used in this study was 578,242 lines excluding comment and blank lines or 5538.7 function points. Languages were 70% C++, 20% C, and 10% Fortran. The code has 130 users and a development team of 14 and an embedded SQE. The code has achieved 100% prime feature test coverage, 73.6% functional test coverage, and 71.5% statement test coverage. The average cyclomatic complexity of the code was 6.25. The codes have evolved over 10 years. Research codes are challenging because there is a desire to balance agility with discipline as well as compliance with DOE standards. Agility is important to allow experimentation with new algorithms and addition of the latest physics features. Discipline is important to increase the quality of the codes. Automation of processes and defect prevention/detection are deployed throughout the software development process. Since resarch codes are a small segment of the software industry, not much information exists in terms of reliability studies on these types of codes. This paper describes attempts to determine the goodness of these research codes. Goodness defined as both correctness of the codes and their fault densities. Correctness is determined by user interviews, peer review; feature based automated testing, and coverage measurement. This paper focuses on the fault density aspect of goodness and reliability of the codes in particular. The approach taken was to use multiple fault density prediction methods and compare results to actual experimentation and other industry studies on fault density. As a result of the predictions and experiments our confidence in the prediction methods was increased and our confidence in the goodness of the code from a fault density perspective was given more context. A large unintended benefit of these experiments was to find defects hidden for years in the codes when using the Monte Carlo reliability testing results to develop heuristic based bug driven tests.

99 GENERAL AND MISCELLANEOUS↗

The software-implemented fault tolerance /SIFT/ approach to fault tolerant computing

SIFT is an experimental computer designed for highly reliable flight-control service in advanced air transports. Its development was intended to integrate and demonstrate the latest techniques in fault-tolerant computing. During its development, several new problems of some generality were uncovered and solved. The technology developed for the validation of its design is seen as being perhaps as important as the design itself. The SIFT design is described, as is the way in which the design and its validation were shaped by the requirements of its intended application. Attention is also given to reliability and fault tolerance. The most significant feature of the hardware design is the absence of elements that can generate multiple faults, such as shared clocks or data buses. It is noted that the software is realized in only 800 lines of code, of which 80% are in a high-level language.

Goldberg, J.↗

Stress field rotation or block rotation: An example from the Lake Mead fault system

The Coulomb criterion, as applied by Anderson (1951), has been widely used as the basis for inferring paleostresses from in situ fault slip data, assuming that faults are optimally oriented relative to the tectonic stress direction. Consequently if stress direction is fixed during deformation so must be the faults. Freund (1974) has shown that faults, when arranged in sets, must generally rotate as they slip. Nur et al., (1986) showed how sufficiently large rotations require the development of new sets of faults which are more favorably oriented to the principal direction of stress. This leads to the appearance of multiple fault sets in which older faults are offset by younger ones, both having the same sense of slip. Consequently correct paleostress analysis must include the possible effect of fault and material rotation, in addition to stress field rotation. The combined effects of stress field rotation and material rotation were investigated in the Lake Meade Fault System (LMFS) especially in the Hoover Dam area. Fault inversion results imply an apparent 60 degrees clockwise (CW) rotation of the stress field since mid-Miocene time. In contrast structural data from the rest of the Great Basin suggest only a 30 degrees CW stress field rotation. By incorporating paleomagnetic and seismic evidence, the 30 degrees discrepancy can be neatly resolved. Based on paleomagnetic declination anomalies, it is inferred that slip on NW trending right lateral faults caused a local 30 degrees counter-clockwise (CCW) rotation of blocks and faults in the Lake Mead area. Consequently the inferred 60 degrees CW rotation of the stress field in the LMFS consists of an actual 30 degrees CW rotation of the stress field (as for the entire Great Basin) plus a local 30 degrees CCW material rotation of the LMFS fault blocks.

Ron, Hagai↗

Fault Slip and Fluid Flow: Seismic Source Analysis to Assess Role of Multiple Slip Patches in Fault Permeability

The relationship between fault reactivation, microearthquakes (MEQs), and permeability evolution during fluid injection plays a critical role in energy harvesting and waste disposal. Recent studies have demonstrated the possibility of predicting fault permeability using cumulative seismic moments of MEQs quantitatively. To understand the underlying physical processes, we conduct fault reactivation experiments using Utah FORGE granitoid and analyze acoustic emission (AE) signals generated during stepwise increases in fluid injection pressure. Frequency analysis of thousands of calibrated AE signals reveals that fault reactivation produces multiple AE source patches with millimeter-scale radii—smaller than the sample fault radius. The cumulative area of the reactivated patches covers the fault multiple times over (∼10x–50x area) for each pressure step. These findings provide mechanistic insight that measured permeability enhancement is not driven by a single large slip event, but by the sequential and interacting activation of multiple slip patches that create a continuous flow pathway.

Nurshal, M. E. M. [Pennsylvania State University, ↗

A multi-agent approach to distribution system fault section estimation in smart grid environment

We report that Multi-Agent Systems (MAS) are seen from different areas as one of the paramount trends for the next generation of power systems. Numerous published studies about MAS discuss its utilization in power distribution networks but none focuses on the prior step to restoration and self-healing that is fault section estimation. This paper aims to show how MAS can improve the utilities’ reliability indexes and consumer satisfaction by overcoming the multiple fault section estimation problem. In order to do this, the authors considered using MAS as a means of communication between smart meters. The purpose of smart meters usage is to employ devices that are already present in smart grids, mainly because of their reading and saving data capacity. The proposed method was tested on a radial feeder generated by the authors. The network was built on HYPERSIM, a software platform of OPAL-RT Technologies. The simulation results show that this MAS provides speed, efficiency, and automation for the process of fault section estimation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tectonic motion in the western United States inferred from very long baseline interferometry measurements, 1980-1986

Over six years of mobile very long baseline interferometry (VLBI) baseline measurements between 12 sites in the western U.S. were used to infer their velocities relative to the North American plate. These velocities were found to be generally consistent with those determined from geologic data and contemporaneous satellite laser ranging measurements in the same region. The discrepancy between the largest velocities determined from the VLBI measurements of 40-48 mm/yr and the relative plate velocity of 50-56 mm/yr predicted from plate motion models is found to be consistent with a broadened distribution of interseismic strain from cyclic activity on the San Andreas and subsidiary faults. The VLBI data are best explained by a cumulative rate of strike-slip motion near the plate boundary of approximately 48 mm/yr, although exclusion of competing values of 56 and 41 mm/yr is based upon very few data. The rates of offshore fault slip inferred from this study range from about 15 mm/yr in central California to negligible amounts in the San Francisco region. Finite element calculations of multiple fault strain distributions show good agreement with systematic variations in the distribution of shear strain along the San Andreas system, as revealed by previous geodetic measurements.

Kroger, Peter M.↗

Computing Fault Displacements from Surface Deformations

Simplex is a computer program that calculates locations and displacements of subterranean faults from data on Earth-surface deformations. The calculation involves inversion of a forward model (given a point source representing a fault, a forward model calculates the surface deformations) for displacements, and strains caused by a fault located in isotropic, elastic half-space. The inversion involves the use of nonlinear, multiparameter estimation techniques. The input surface-deformation data can be in multiple formats, with absolute or differential positioning. The input data can be derived from multiple sources, including interferometric synthetic-aperture radar, the Global Positioning System, and strain meters. Parameters can be constrained or free. Estimates can be calculated for single or multiple faults. Estimates of parameters are accompanied by reports of their covariances and uncertainties. Simplex has been tested extensively against forward models and against other means of inverting geodetic data and seismic observations. This work

Lyzenga, Gregory↗

Real-Time Distributed Embedded Oscillator Operating Frequency Monitoring

A document discusses the utilization of embedded clocks inside of operating network data links as an auxiliary clock source to satisfy local oscillator monitoring requirements. Modem network interfaces, typically serial network links, often contain embedded clocking information of very tight precision to recover data from the link. This embedded clocking data can be utilized by the receiving device to monitor the local oscillator for tolerance to required specifications, often important in high-integrity fault-tolerant applications. A device can utilize a received embedded clock to determine if the local or the remote device is out of tolerance by using a single link. The local device can determine if it is failing, assuming a single fault model, with two or more active links. Network fabric components, containing many operational links, can potentially determine faulty remote or local devices in the presence of multiple faults. Two methods of implementation are described. In one method, a recovered clock can be directly used to monitor the local clock as a direct replacement of an external local oscillator. This scheme is consistent with a general clock monitoring function whereby clock sources are clocking two counters and compared over a fixed interval of time. In another method, overflow/underflow conditions can be used to detect clock relationships for monitoring. These network interfaces often provide clock compensation circuitry to allow data to be transferred from the received (network) clock domain to the internal clock domain. This circuit could be modified to detect overflow/underflow conditions of the buffering required and report a fast or slow receive clock, respectively.

Pollock, Julie↗

Summary Article: IEA HPP Annex 36: Quality Installation / Quality Maintenance Sensitivity Studies

The outcome from this Annex activity clearly identifies that poorly designed, installed, and/or maintained heat pumps operate inefficiently and waste considerable energy compared to their as-designed potential. Additionally, it is clear that small faults for a given field-observed practice are significant, that some attribute deviations (in various equipment applications and geographical locations) have a larger impact than others, and that multiple faults or deviations have a cumulative impact on heat pump performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A SIMULATION BASED APPROACH TO IMPACT ASSESSMENT OF PHYSICAL FAULTS: LARGE COMMERCIAL BUILDING HVAC CASE STUDY

We develop a simulation-based approach to fault impact analysis for a single duct VAV system, and analyze the dynamic and steady-state impact of equipment physical faults on building operation. The simulation model, a virtual testbed, can capture physical faults in the HVAC system of a large commercial building. The model can be utilized for generating data that can then be analyzed to quantify the impact of single or multiple faults. We illustrate the implementation of three physical faults: supply air temperature sensor bias, outdoor air temperature sensor bias, and cooling coil valve stuck. We simulate each fault with several fault intensity levels and at different seasonal operating conditions. Then, we analyze the impact of the above-mentioned faults using the metrics. The results show that the impact of a given physical fault depends on implemented control logic sequence and the seasonal operating conditions.

Chen, Yan↗

Incipient fault detection study for advanced spacecraft systems

A feasibility study to investigate the application of vibration monitoring to the rotating machinery of planned NASA advanced spacecraft components is described. Factors investigated include: (1) special problems associated with small, high RPM machines; (2) application across multiple component types; (3) microgravity; (4) multiple fault types; (5) eight different analysis techniques including signature analysis, high frequency demodulation, cepstrum, clustering, amplitude analysis, and pattern recognition are compared; and (6) small sample statistical analysis is used to compare performance by computation of probability of detection and false alarm for an ensemble of repeated baseline and faulted tests. Both detection and classification performance are quantified. Vibration monitoring is shown to be an effective means of detecting the most important problem types for small, high RPM fans and pumps typical of those planned for the advanced spacecraft. A preliminary monitoring system design and implementation plan is presented.

Milner, G. Martin↗

The Soil Moisture Acttive Passive Mission: Fault Protection Performance and Lessons Learned

Fault protection as a discipline involves a collection of flight software logic and operational processes for detecting unacceptable anomalous behavior, responding prior to reaching criticality, restricting the propagation of a failure beyond a fault containment region, and recovering the vehicle back to full or degraded functionality if possible. The System Fault Protection (SFP) design for the SMAP Earth orbiter was put to the test during its 90-day vehicle commissioning activities. During this time, the SFP software autonomously protected the vehicle from multiple faults to critical hardware, and the operations team successfully returned the observatory to its science state. The SFP also performed well in the presence of anomalous behavior below true safety limits by not taking unnecessary response actions, instead allowing the operations team time to monitor the behavior. Certain aspects of the SFP design were modified during operations via both parameter updates and a full flight software update in order to better match the vehicle behavior in the flight environment. An evaluation of the SMAP SFP performance during vehicle Commissioning will be provided in this paper, as well as a set of lessons learned largely focused on visibility, SFP mutability in operations, responses to peripheral device faults, and Safe Mode recovery and design. By capturing some of the knowledge gained during SMAP Commissioning, it is intended that this paper provide guidance for making future System Fault Protection designs more robust and supportive of operations.

Clark, Jessica↗

Bearing Fault Detection on Wind Turbine Gearbox Vibrations Using Generalized Likelihood Ratio-Based Indicators: Preprint

Studies in condition monitoring literature often aim to detect rolling element bearing faults because they have one of the biggest shares among defects in turbo machinery. Accordingly, several prognosis and diagnosis methods have been devised to identify fault signatures from vibration signals. The underlying idea behind traditional indicators often revolves around tracking both cyclostationarity and abnormal impulses in the vibration signals without distinguishing the two. A recently proposed method to capture the rolling element bearing degradation lays out the groundwork for new indicator families utilizing generalized likelihood ratio test. This novel approach exploits the cyclostationarity and the impulsiveness of vibration signals independently in order to estimate the most suitable indicators for a given fault. However, the method has yet to be tested on complex experimental vibration signals such as those of a wind turbine gearbox. In this study, the approach is applied to the NREL Wind Turbine Gearbox Condition Monitoring Round Robin Study data set for bearing fault detection purposes. The data set is measured on an experimental test rig of a wind turbine gearbox, hence the complexity of the vibration signals is similar to a real case. Furthermore, the new indicators are also tested with signals that carry multiple fault signatures. The outcome demonstrates that the proposed method is capable of distinguishing between healthy and damaged vibration signals measured on a complex wind turbine gearbox.

condition monitoring↗

Model-Based Diagnostics for Propellant Loading Systems

The loading of spacecraft propellants is a complex, risky operation. Therefore, diagnostic solutions are necessary to quickly identify when a fault occurs, so that recovery actions can be taken or an abort procedure can be initiated. Model-based diagnosis solutions, established using an in-depth analysis and understanding of the underlying physical processes, offer the advanced capability to quickly detect and isolate faults, identify their severity, and predict their effects on system performance. We develop a physics-based model of a cryogenic propellant loading system, which describes the complex dynamics of liquid hydrogen filling from a storage tank to an external vehicle tank, as well as the influence of different faults on this process. The model takes into account the main physical processes such as highly nonequilibrium condensation and evaporation of the hydrogen vapor, pressurization, and also the dynamics of liquid hydrogen and vapor flows inside the system in the presence of helium gas. Since the model incorporates multiple faults in the system, it provides a suitable framework for model-based diagnostics and prognostics algorithms. Using this model, we analyze the effects of faults on the system, derive symbolic fault signatures for the purposes of fault isolation, and perform fault identification using a particle filter approach. We demonstrate the detection, isolation, and identification of a number of faults using simulation-based experiments.

Daigle, Matthew John↗

Airborne Advanced Reconfigurable Computer System (ARCS)

A digital computer subsystem fault-tolerant concept was defined, and the potential benefits and costs of such a subsystem were assessed when used as the central element of a new transport's flight control system. The derived advanced reconfigurable computer system (ARCS) is a triple-redundant computer subsystem that automatically reconfigures, under multiple fault conditions, from triplex to duplex to simplex operation, with redundancy recovery if the fault condition is transient. The study included criteria development covering factors at the aircraft's operation level that would influence the design of a fault-tolerant system for commercial airline use. A new reliability analysis tool was developed for evaluating redundant, fault-tolerant system availability and survivability; and a stringent digital system software design methodology was used to achieve design/implementation visibility.

Bjurman, B. E.↗