Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiphase power system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

43 records · Page 3

Transient simulation of biomass combustion in a circulating fluidized bed riser

Interest in circulating fluidized bed (CFB) boilers as a power generation technology has sky-rocketed in recent years because of several advantages this technology offers over conventional boilers, such as increased gas-solid mixing, which results in higher combustion efficiency and the ability to use lower rank fuels. CFB combustors are operated at lower temperatures than conventional thermal power generation combustors, thus reducing NO x emissions, while SO 2 emissions can be conveniently controlled through the addition of Ca-based sulfur sorbents within the combustor. Herin this paper summarizes the modeling effort on a 50 kW th CFB combustor designed, built, and operated at CanmetENERGY in Ottawa, Canada. The numerical model employs the multiphase particle-in-cell (PIC) approach in the open-source Multiphase Flow with Interphase eXchanges (MFiX) Software Suite. The MFiX-PIC model parameters for the simulation are tuned against cold-flow experiments from CanmetENERGY using olivine sand as the inert bed material. It is shown that for the relatively coarse fluid meshes and large parcel sizes necessitated by the scale of the simulation, filter size dependent corrections to the drag law must be incorporated to ensure accuracy of the simulation results. The validated cold flow model is extended to simulate reacting flow with torrefied hardwood as the feedstock and to validate the combustion reaction scheme. The species concentrations at the riser outlet are compared against CanmetENERGY’s experiments and show satisfactory agreement. The simulations demonstrate the ability of MFiX-PIC to accurately capture both the physics and chemistry of a CFB combustor at bench scales, which can be further extended to pilot- and industrial-scale systems.

09 BIOMASS FUELS↗

Insights into mixing of non-isothermal multi-polymer melts for complex plastics recycling

Catalytic recycling or upcycling of plastics is often limited not by catalyst performance, but by transport, arising from highly viscous, non-Newtonian polymer melts. In this work, we develop a reactor-scale framework that integrates rheological measurements, constitutive modeling, computational fluid dynamics (CFD), and experiments to quantify mixing, heat transfer, and dispersion in surrogate hydrocarbon melts representing mixed plastics systems. Temperature- and shear rate-dependent viscosity of low-density polyethylene (LDPE) and high-density polyethylene (HDPE) is measured to create two surrogate polymers (PLD and PHD) that capture the dominant shear-thinning flow behavior while neglecting strong elastic effects, enabling tractable simulation of non-isothermal, polymer-melt mixing using a Carreau-Arrhenius generalized Newtonian framework. Three-dimensional CFD simulations are employed to evaluate impeller performance in PLD using mixing time, cavern volume, thermal uniformity, and interfacial area for regimes in which viscoelastic effects are not dominant. We show that magnetic stir bars commonly used in lab-scale studies produce large thermal gradients (~60 °C) and poor mixing, even under idealized power delivery and polymer flow conditions. In contrast, close-clearance anchor impellers achieve near-isothermal operation, reduce mixing times by up to 5×, and provide >90% active circulation volume. We further demonstrate that, at low pseudo-Deborah number (De*), motor power requirements can be predicted directly from shear rate-dependent rheology using the Carreau-Arrhenius framework, enabling rational selection of operating conditions. Extension to surrogate immiscible multi-polymer systems based on PLD and PHD shows that interfacial area is highly sensitive to operating conditions and impeller design, with coaxial anchor-turbine configurations enhancing dispersion by up to 4 × .

Close-clearance impellers↗

Geometric Scale-up Experiments on Fluidization of Geldart B Glass Beads

The objective of this work is to provide a valuable database from controlled experiments for validating computational models. Recently, coarse-grained techniques such as particle-in-cell (PIC) or coarse-grained discrete element modeling (DEM) have gained popularity due to their computational efficiency while modeling large-scale systems; however, the influence of model parameters and their sensitivities at different geometric scales and flow conditions remain to be analyzed. These datasets are critical for the multiphase flow research community to assess predictive capability of modeling techniques as well as elucidate the hydrodynamic behavior in these systems. This study performed fluidization experiments using three different test sections with internal diameters of 2.5, 4, and 6 in. The operating conditions, bed material, and range of flow velocities at the inlet were constant in all the units, which were not hydrodynamically scaled. Glass beads having a Sauter Mean Diameter of 332 μm were used. Superficial velocity was varied from 2.97 to 5.35 times the minimum fluidization velocity and the initial static bed height was 0.1524 m. The order in which the experiments were performed was randomized and replicates were included to provide uncertainty in measurements. Statistics of differential pressure and bed height from these tests were reported. Future plans include validating PIC methodology in the open-source software, MFiX (Multiphase Flow with Interphase Exchanges) using results from this study. This could further be extended to determine optimal model parameters using inverse techniques such as deterministic calibration or Bayesian inference.

20 FOSSIL-FUELED POWER PLANTS↗

Microstructural characterization of phase-separated co-deposited Cu–Ta immiscible alloy thin films

Elevated temperature co-sputtering of immiscible elements ends in a variety of self-organized morphologies due to phase separation. Cu–Ta is used as a model system to understand the evolution of phase-separated microstructural morphologies by co-sputtering thin films with nominal 50–50 at.% composition at four temperatures: 25, 400, 600, and 800 °C. Scanning/transmission electron microscopy of the film cross sections showed the microstructure morphology varied from nanocrystalline Cu–Ta at 25 °C to a wavy ribbon-like structure at 400 °C, to Cu-rich agglomerates surrounded by Ta-rich veins at 600 and 800 °C. In the agglomerate-vein morphology, microstructural features were present on two length scales, from a few nanometers to a few tens of nanometers, thus making the structures hierarchical. On the nanoscale, the Cu-rich agglomerates contained Ta precipitates, whereas the Ta-rich veins had embedded Cu nanocrystals. The various microstructures can be attributed to the highly disparate constituent element interdiffusion at the deposition temperatures with the Cu having orders of magnitude higher mobility than Ta at the deposition temperatures. This research of processing–microstructure relationship will be useful in guiding the design of hierarchical multiphase microstructures in binary or multicomponent thin films with tailored mechanical properties.

36 MATERIALS SCIENCE↗

Full-Loop Simulation of the Combustion of Biomass in a Circulating Fluidized Bed Combustor

Interest in circulating fluidized bed (CFB) boilers as a power generation technology has skyrocketed in recent years because of several advantages this technology offers over conventional boilers, such as increased gas-solid mixing, which results in higher combustion efficiency, and the ability to use lower rank fuels. CFB combustors are operated at lower temperatures than conventional thermal power generation combustors, thus reducing NO x emissions, while SO 2 emissions can be conveniently controlled through the addition of Ca-based sulfur sorbents within the combustor. This report summarizes the development of a comprehensive computational fluid dynamics (CFD) model for biomass combustion in a 50 kW th CFB combustor employing the multiphase particle-in-cell (PIC) approach in the open-source Multiphase Flow with Interphase eXchanges (MFiX) Software Suite at the U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL). The experimental combustor was designed, built, and operated at CanmetENERGY, Natural Resources Canada in Ottawa, Canada. This work is the culmination of a multi-year collaboration between NETL and CanmetENERGY. The hydrodynamics in the full loop are validated against cold-flow experiments conducted at CanmetENERGY. To mimic the dense packing in the standpipe in the absence of a collisional model in the MFiX-PIC approach, the ram valve in the return leg is partially closed to obstruct the flow. A combustion reaction scheme was developed that considers the volatiles released by the fuel as a lumped species that fully converts to CO 2 and H 2 O. The so-called enhanced simplified combustion scheme produces an excellent match with experimental data in terms of the species concentrations of CO 2 and O 2 at the outlet and the freeboard, demonstrating the utility of the comprehensive model for a range of flow conditions and operating temperatures. Furthermore, the model can be readily adapted to simulate combustion of a variety of biomass fuels as well as co-fired systems under air and oxy-fuel conditions.

09 BIOMASS FUELS↗

Temperature Homogeneity under Selective and Localized Microwave Heating in Structured Flow Reactors

Selective heating of different phases of multiphase systems via microwaves can result in energy savings and suppression of side reactions. However, materials properties and operating conditions that maximize temperature gradients are poorly understood. Here we utilize computational fluid dynamics (CFD) computations and temperature measurements in structured flow reactors (monoliths) in a monomodal microwave cavity to assess the temperature difference between the walls and the fluid and develop a simple lumped model to estimate when temperature gradients exist. We also explore the material’s thermal and electrical properties of structured reactors for isothermal catalyst conditions. We propose that CFD simulations can be used as a nonintrusive, predictive tool of temperature homogeneity. Importantly, we demonstrate that localized heating in the bed under several conditions rather than selective heating is responsible for the selectivity enhancement. Furthermore, our results indicate that structured beds made of high thermal conductivity materials avoid arcing and enable temperature homogeneity and low electrical conductivity materials allow microwaves to penetrate the domain.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Velocity Profiling of a Gas–Solid Fluidized Bed Using Electrical Capacitance Volume Tomography

In this study, a method of producing velocity profile maps from electrical capacitance volume tomography (ECVT) measurements by reconstructing displacement from measured changes in capacitance is developed and applied to fluidized bed systems. The mapping of the reconstruction leverages the gradient of the sensitivity distribution of the ECVT sensor to circumvent the need for image cross correlation techniques. Experimental data of both bubbling and slugging fluidized beds are collected in a cold flow model. Adaptation of the technique is discussed in detail, and velocity profiles are obtained for a range of gas flow rates. The produced velocity maps are compared against the established methods of cross correlation and against empirical correlations from the literature and are found to agree well in tracking slug and bubble velocity. The exception is when the tracked object is large relative to the ECVT sensor dimensions, a scenario that can be avoided through proper sensor design. The quantities of average velocity, momentum, and solid and gas volume fraction are derived from the image and velocity profiles. The results demonstrate and extend the power of ECVT as a measurement tool for the study and monitoring of gas–solid fluidized beds by providing a computationally cheaper alternative to 3-D cross correlation for deriving velocity profiles.

47 OTHER INSTRUMENTATION↗