Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “model reference control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Influence of Control and Limiter Schemes on Sequence-Domain Fault Models of Grid-Forming Inverter-Interfaced Distributed Generators

Unlike synchronous generators, the fault response of grid-forming (GFM) inverter-interfaced distributed generators (IIDGs) is notably governed by the selection of control and current limiting strategies rather than inherent physical traits. While recent research has focused on the sequence domain fault model of GFM IIDGs, a research gap exists in elucidating the influence of control and current limiting schemes on this model's characteristics. This article aims to fill this void by examining how different control and current limiting schemes influence the positive and negative sequence impedances in the phasor-domain fault model of GFM IIDGs. This investigation encompasses droop-based, virtual synchronous machine-based, and virtual oscillator-based reference generation controls alongside rotating and stationary reference-frame-based voltage controls. Furthermore, saturation-based, latching-based, circular and virtual impedance-based current limiting schemes are analyzed. To achieve this goal, a thorough numerical simulation study is conducted. Findings indicate that outer reference generation controls exhibit minimal impact. Conversely, the choice of voltage control and various current limiting schemes emerge as the predominant factors shaping the sequence models of GFM IIDGs. These analyses and results are instrumental in devising reliable protection strategies within inverter-based grids, as a comprehensive understanding of electrical elements in the sequence domain is imperative for effective protective measures.

current limiters↗

Modeling Losses in a Three Electrode System Towards Fast Charge Control

In this work we demonstrate the applicability of a versatile separator-reference mounted electrode in a three-electrode setup to accurately capture the primary current pathway in the battery cell during operation, calibrate a porous electrode model to the individual anode and cathode potential signals, and assign the various resistances to electrochemical phenomena in the battery cell. This calibrated electrochemical model is validated using continuous rate discharges associated with highway driving scenarios in an electric vehicle, and in turn utilized to predict the local anode potential and proximity to lithium plating onset. Finally, we demonstrate the strategy associated with utilization of the model to estimate constant anode potential charging during fast charge scenarios at various rates and starting conditions as a future look to fast charge calibration development and controls.

Garrick, Taylor R. (ORCID:0000000322518129)↗

Adaptive Control for Residential HVAC Systems to Support Grid Services

In this paper, we propose an adaptive control strategy for residential buildings' heating ventilation and air conditioning (HVAC) systems to support grid services. The proposed control strategy captures the time-varying characteristics of the building and weather environments. It assigns to each building a local controller to maintain the indoor temperature within a desired comfort level, while the load aggregator allocates the assigned reference power provided by the distribution system operator to support a specific grid service, such as demand peak reduction, balancing supply and demand, and consuming the solar photovoltaic (PV) power locally. Simulation results are presented to verify the performance of the proposed control strategy in terms of maintaining the indoor temperatures of several buildings within the desired comfort bands while tracking the reference power profile. Also, a comparison with a recently developed model-free control strategy is presented.

Wu, Tumin↗

Large-signal Stability Analysis of Grid-forming Inverters with Equivalent-circuit Models

Here, this paper proposes an energy function-based direct method for large-signal stability assessment of grid-forming (GFM) inverters leveraging an equivalent-circuit representation of all involved control- and physical-layer dynamics. Three different primary controls, a standard inner-current outer-voltage cascaded-control architecture, output LCL filter, and reference-current saturation limiting are featured in the modeling and analysis framework. A composite energy function for the GFM inverter is obtained by summing up individual energy contributions gleaned from the circuit representation. The approach can readily be generalized to different primary controls, output-filter arrangements, and current limiters since it is based on a circuit-theoretic foundation. Numerical simulations validate the efficacy of the approach in estimating the critical clearing time following a large-signal disturbance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulation of CEFR neutronic start-up tests with FENNECS

This paper presents simulation results of selected Neutronic Start-up Tests of the China Experimental Fast Reactor (CEFR) obtained by the neutronics code FENNECS that have been performed within the frame of the IAEA Coordinated Research Program I31032. The Finite Element Neutronics code FENNECS is developed at GRS and solves the few-group steady-state and transient diffusion equation using a Galerkin-based finite element approach. Its main purpose is the safety assessment of Small Modular Reactors and Micro Reactors with complex geometry (e.g., rotating control drums) which gain increased interest internationally. Serpent has been applied to create reference models of the CEFR and cross-section libraries in 10 energy groups for FENNECS. Using these libraries, the following experiments have been simulated with FENNECS: net criticality, control rod integral and differential worth, void reactivity effect, subassembly exchange reactivity effects and reaction rate distribution. The obtained satisfactory agreements with the measurements represent a valuable contribution to the validation of FENNECS. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental investigation of advanced turbine control strategies and load-mitigation measures with a model-scale floating offshore wind turbine system

To advance the control co-design of offshore wind energy systems, the authors perform basin-scale experiments with a fully instrumented and actuated floating offshore wind turbine model. The model consists of a 1:70 scale performance-matched model of the International Energy Agency Wind Technology Collaboration Programme 15-MW reference turbine atop the VolturnUS-S semisubmersible platform. The Reference OpenSource Controller provides real-time blade pitch and generator torque control. Here we aim to develop an open data set for the validation of numerical models in predicting the influence of turbine control and load-mitigation measures. For this purpose, we measure the effects of advanced turbine control features, including peak shaving and floating feedback as well as hull-based control using tuned mass dampers on the system. Overall, the results demonstrate measurable and consistent influences from the control and load-mitigation measures, thus confirming the usefulness as a validation data set. Peak shaving attenuates the response to wind turbulence at near-rated wind speed. Floating feedback reduces the load and platform pitch motion associated with the negative damping induced by blade pitch control. The tuned mass dampers also attenuate the system response near the targeted frequencies under suitable conditions. We also identify detrimental side effects of each load-mitigation measure.

17 WIND ENERGY↗

Dynamic Model of Active Front-End Converters with 2DOF-PI Controllers for DC Bus Voltage Control

In most of the research, a conventional one degree-of-freedom type proportional-integral controller (1DOF-PI) is used for the regulation of the dc bus voltage in an Active Front-End Converter (AFEC). This paper proposes a two degree-of-freedom type proportional-integral controller (2DOF-PI) for the regulation of dc bus voltage in an AFEC. Such a controller eliminates the left-half plane (LHP) zero in the command-to-output transfer function for dc bus voltage regulation that is inherent to the conventional 1DOF-PI for this application. The dynamic model of an AFEC in the synchronous reference frame (SRF) is presented. An inner current control and outer dc voltage control loop is built for controlling the AFEC. Vector-control scheme is employed to achieve decoupled control of direct-axis and quadrature-axis currents. The outer dc voltage control loop is designed with a 2DOF-PI to complete the control system. Transfer function (TF) of the controller is derived based on the presented model and used to calculate the controller gains. Transient and steady state performance of the designed controllers are investigated in MATLAB/Simulink and results presented.

Thapa, Anup↗

A New Proposal Generalized Predictive Control Algorithm With Polynomial Reference Tracking Applied for Sodium Fast Reactors

This paper proposes a generalized predictive control (GPC) with constraints and orthonormal Laguerre functions using the simplified model of the primary system (reactor core and intermediate heat exchanger (IHX)) of a prototypical sodium fast reactor (SFR). This paper develops a multiple-input multiple-output (MIMO) GPC with input constraints able to track polynomial references of any degree applied in coolant temperature difference across the core and fractional power. The manipulated variables of the GPC-SFR are the reactivity and the sodium flow rate of the primary and secondary pipes. Moreover, orthonormal Laguerre functions and step down condition number techniques were also applied to avoid the numerical ill-conditioning issue in quadratic programming of large systems. Thus, a GPC type-2 was designed to control fractional power, coolant temperature difference across the core and sodium tank temperature of the SFR primary system when temperature references change according to a linear ramp after reaching their steady-state operation, sustaining 100% power operation on the reactor. In order to analyze the load tracking capability of the GPC-SFR type-2, the load following from 100% fractional power (FP) to 60% FP at 0.8% FP/min rate is simulated. Constraints on the rate of coolant temperature difference across the core and reactivity were applied for the design safety. For comparison criteria, this paper compares the GPC-SFR type-2 with the GPC-SFR type-1, i.e., standard model predictive control (MPC), to verify the viability and superior performance of the proposal regarding: (a) ramp-tracking capability of temperature and load; (b) the rejections of a reactivity disturbance of -1 cent and a secondary sodium inlet temperature disturbance of +10°F; and (c) a simulation with uncertainty in reactor design. The simulations show that the GPC-SFR type-2 overcome the GPC-SFR type-1 robustness and performance.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

H ∞ Control for Energy Dispatch in Autonomous Nanogrid With Communication Delays

This paper proposes an optimal controller and estimator for energy dispatch to balance the power supply and demand considering communication delays. The proposed algorithm involves modeling an autonomous nanogrid (ANG) consisting of distributed energy resources, energy storage systems, loads, an $H$ ∞ controller with a reference power modulation technique, and a state estimator. The ANG was developed to express the dynamic supply-demand energy balance of a nanogird system. Reference power modulation was designed to generate the desired ESS power based on the imbalanced energy. Random communication delays were modeled using a stochastic variable satisfying the Bernoulli random binary distribution. The optimal $H$ ∞ controller and estimator were developed using a linear matrix inequality approach to exponentially stabilize the closed-loop system. Simulations were performed using real daily demand forecasts obtained from the Korea Meteorological Administration to demonstrate the effectiveness of the proposed real-time optimization algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Identification and control of the exhaust using gas perturbations in the DIII-D tokamak

This paper presents perturbative experiments that enable the validation and development of control-oriented models for exhaust control. We identify the response of the divertor plasma and scrape-off layer in the DIII-D tokamak to deuterium and nitrogen multi-sine perturbations, in favorable and unfavorable field directions for H-mode access. We obtained good signal-to-noise ratios in the 1–10 Hz frequency range by measuring Balmer-alpha, Lyman-alpha, and N 4+ line emission, radiated power, and neutral pressure. We find a similar phase response across gas species and magnetic field directions, while the gain response is nonlinear. With these experiments, we identify a control-oriented model to design a divertor radiated power controller to track specified reference waveforms in conjunction with resonant magnetic perturbations. Although the physics basis for compatibility between detachment and resonant magnetic perturbation edge-localized mode suppression remains to be demonstrated, the present results provide a robust controller that represents a promising step toward future joint control strategies.

detachment control↗

An Introduction to the Federated Architecture for Secure and Transactive Distributed Energy Management Solutions (FAST-DERMS)

Deployment and capability of distributed energy resources (DER) in power systems is growing rapidly. These resources present an opportunity for low-cost provision of energy and grid services. The Federal Energy Regulatory Commission recently provided rulings to enable market participation of these distribution-connected resources, but the prevailing strategies for their management may not scale well to meet future needs. This paper introduces the Federated Architecture for Secure and Transactive Distributed Energy Management Solutions (FAST-DERMS) which was designed to address this need. In it we describe the architectural features of the approach, and a reference controls implementation employing a hierarchical coordination that includes stochastic optimization, model predictive control, and a simple real-time management scheme. Sample results from simulation show firm transmission-level service provision measured at the distribution substation.

grid architecture↗

Simulating Energy and Security Interactions in Semiconductor Manufacturing: Insights from the Intel Minifab Model

Semiconductor manufacturing is a highly complex. Fabrication plants must deal with re-entrant flows to support multiple types of wafers being produced simultaneously, each with their own deadlines and specifications. The manufacturing process itself depends upon the ability to control and programmatically adjust a variety of environmental conditions including temperature, humidity, and air quality. In addition, wafer fabrication consumes large amounts of electricity. Emerging technologies may help reduce the energy footprint of such facilities but can introduce cybersecurity risks. Therefore, this paper presents a modeling and simulation framework to quantify tradeoffs between operational measures of performance, energy consumption, and cybersecurity controls. We augment the Intel Minifab model, with the Purdue Enterprise Reference Architecture (PERA) for cybersecurity as well as tool-level energy consumption data from a real-world semiconductor manufacturing testbed. In this manner, we intend to provide stakeholders with a systematic, data-driven approach to evaluate emerging risks within the manufacturing process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Introduction to the Federated Architecture for Secure and Transactive Distributed Energy Management Solutions (FAST-DERMS): Preprint

Deployment and capability of distributed energy resources (DER) in power systems is growing rapidly. These resources present an opportunity for low-cost provision of energy and grid services. The Federal Energy Regulatory Commission recently provided rulings to enable market participation of these distribution-connected resources, but the prevailing strategies for their management may not scale well to meet future needs. This paper introduces the Federated Architecture for Secure and Transactive Distributed Energy Management Solutions (FASTDERMS) which was designed to address this need. In it we describe the architectural features of the approach, and a reference controls implementation employing a hierarchical coordination that includes stochastic optimization, model predictive control, and a simple real-time management scheme. Sample results from simulation show firm transmission-level service provision measured at the distribution substation.

DERMS↗

Results from the FOCAL Experiment Campaign 1: Turbine Control Co-Design

This paper summarizes the scaling approach and results from the first experimental campaign of the Floating Offshore-wind and Controls Advanced Laboratory (FOCAL) Experimental Program, which is focused on developing public data sets to support the validation of numerical models for floating wind control co-design. A 1:70 Froude-scale performance-matched model of the IEA Wind 15-MW reference turbine was designed, built, and characterized on a fixed base. The National Renewable Energy Laboratory's Reference Open-Source COntroller (ROSCO) was integrated into the scale testing to examine the impact advanced turbine and generator control strategies have on turbine performance and loads, enabling validation of control strategies for floating wind design optimization.

17 WIND ENERGY↗

Magneto mitochondrial dysfunction mediated cancer cell death using intracellular magnetic nano-transducers

Mitochondria are crucial regulators of the intrinsic pathway of cancer cell death. The high sensitivity of cancer cells to mitochondrial dysfunction offers opportunities for emerging targets in cancer therapy. Herein, magnetic nano-transducers, which convert external magnetic fields into physical stress, are designed to induce mitochondrial dysfunction to remotely kill cancer cells. Spindle-shaped iron oxide nanoparticles were synthesized to maximize cellular internalization and magnetic transduction. The magneto-mechanical transduction of nano-transducers in mitochondria enhances cancer cell apoptosis by promoting a mitochondrial quality control mechanism, referred to as mitophagy. Furthermore, in the liver cancer animal model, nano-transducers are infused into the local liver tumor via the hepatic artery. After treatment with a magnetic field, in vivo mitophagy-mediated cancer cell death was also confirmed by mitophagy markers, mitochondrial DNA damage assay, and TUNEL staining of tissues. This study is expected to contribute to the development of nanoparticle-mediated mitochondria-targeting cancer therapy and biological tools, such as magneto-genetics.

60 APPLIED LIFE SCIENCES↗

Zero Voltage Switching AC-DC Converter Based on Zero State Modulation (ZSM)

In this paper, a half-bridge building block that can achieve soft switching across the complete operating range while operating under fixed frequency is proposed. In addition, dead-beat model predictive controls to control the same are also proposed. The proposed converter, referred to as zero-state modulated (ZSM) converter, uses a zero state, enabled by a small auxiliary switch, to achieve soft-switching. The approach allows lower switching loss, controlled dv/dt, small filter inductor, fixed frequency operation allowing interleaving to reduce filter capacitor. A single half-bridge building block can used to realize a ZVS DC-DC converter or multiple of these building blocks can be used to achieve soft switching 1-phase or 3-phase AC-DC converters.

Kandula, Prasad↗

Control of hybrid boosting in highly diluted internal combustion engines

A novel hybrid system enabling both flexible supercharging and limited torque assist is studied to mitigate transient response challenges of a turbocharged spark ignition engine equipped with low pressure exhaust gas recirculation. The hybrid system, called a power split supercharger (SC), is configured with a planetary gear set that splits the supercharging power between a small low-voltage electric motor and the engine crankshaft. The air path controller relies on the coordination of four actuators on the engine side and three low-level actuators on the hybrid boosting device. A decentralized control scheme is used in this work, in which the master–slave structure of the boost pressure controller decreases the turbo-lag associated with exhaust gas recirculation, while minimizing the SC operation for fuel economy. A vector reference governor is used to prevent compressor surge during engine tip-outs. In addition, the desired intake manifold pressure is modified to provide time for evacuating the exhaust gas recirculation and avoiding misfires when transitioning to low load, while the hybrid capability of the power split SC is used to recuperate the unwanted generated power. All controllers are validated on both a mean value engine model and a high-fidelity engine model. Practical challenges of implementing the vector reference governor to the highly nonlinear engine air path with pressure pulsations originating from the engine reciprocation are discussed and some solutions are proposed.

Engineering↗

Dynamic P-Q Capability and Abnormal Operation Analysis of a Wind Turbine with Doubly-Fed Induction Generator

After several accidents occurred in wind farms in the United States and around the world, the subsynchronous oscillation (SSO) issues in grid-connected wind farms have gained serious attention. Particularly, these issues have caused significant challenges to wind turbines with a doubly fed induction generator (DFIG) because it is connected to the grid via both its stator and rotor paths. Traditionally, a P-Q capability chart is utilized to assure the safe operation boundary for a synchronous generator. But the energy conversion characteristics of a DFIG wind turbine are completely different. A critical factor to affect the reliable operation of a DFIG wind turbine is the rated current and pulse-width modulation (PWM) saturation constraints of its power converters. These constraint conditions can be affected by the wind turbine rotating speed and grid conditions. However, a detailed study of DFIG P-Q capability from these perspectives has not been conducted, which has hindered adequate understanding of many abnormal wind turbine operations reported in the literature and the development of advanced control technologies to overcome the challenges. The proposed study in this paper considers vector control implementation to DFIG power electronic converters in the dq reference frame, and the models and algorithms developed for the P-Q capability study have addressed specific DFIG power converter constraints that are different from those of a traditional synchronous generator. The paper especially focuses on exploring the dynamic natures of DFIG P-Q capability under uncertain and variable conditions to explore the root causes of many abnormal operations of DFIG wind turbines reported in the literature. The proposed study is validated through an electromagnetic transient simulation model of a grid-connected DFIG wind turbine. The proposed study has the potential to lead to the development of new DFIG control technologies that can help overcome the challenges for many abnormal operations of DFIG wind turbines.

17 WIND ENERGY↗