Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microwave sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Spin Squeezing with Itinerant Magnetic Dipoles

Entanglement can improve the measurement precision of quantum sensors beyond the shot noise limit. Neutral atoms, the basis of some of the most precise and accurate optical clocks and interferometers, do not naturally exhibit the all-to-all interactions traditionally used to generate such entangled states. On the other hand, these systems exhibit exceedingly high degrees of experimental control over parameters such as temperature, spatial entropy, and itinerancy. In this work, we investigate spin squeezing in a highly coherent itinerant system of neutral atoms with magnetic dipole-dipole interactions. We achieve 7.1 dB of metrologically useful squeezing using finite-range spin-exchange interactions in an erbium quantum gas microscope, and we demonstrate that introducing atomic motion, realizing a dipolar 𝑡−𝐽 model, protects the spin sector coherence at low fillings, significantly improving the achievable spin squeezing in a 2D dipolar system. This work’s protocol can be implemented with most neutral atoms, opening the door to quantum-enhanced metrology in other itinerant dipolar systems, such as molecules or optical lattice clocks, and serves as a novel method for studying itinerant quantum magnetism with long-range interactions.

Atomic, optical & lattice clocks↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino, Rafael [Unlisted]↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

Quantum Entanglement between Optical and Microwave Photonic Qubits

Entanglement is an extraordinary feature of quantum mechanics. Sources of entangled optical photons were essential to test the foundations of quantum physics through violations of Bell’s inequalities. More recently, entangled many-body states have been realized via strong nonlinear interactions in microwave circuits with superconducting qubits. Here, we demonstrate a chip-scale source of entangled optical and microwave photonic qubits. Our device platform integrates a piezo-optomechanical transducer with a superconducting resonator which is robust under optical illumination. We drive a photon-pair generation process and employ a dual-rail encoding intrinsic to our system to prepare entangled states of microwave and optical photons. We place a lower bound on the fidelity of the entangled state by measuring microwave and optical photons in two orthogonal bases. This entanglement source can directly interface telecom wavelength time-bin qubits and gigahertz frequency superconducting qubits, two well-established platforms for quantum communication and computation, respectively. Published by the American Physical Society 2024

Physics↗

Detection of Galactic and Extragalactic Millimeter-wavelength Transient Sources with SPT-3G

High angular resolution cosmic microwave background experiments provide a unique opportunity to conduct a survey of time-variable sources at millimeter wavelengths, a population that has primarily been understood through follow-up measurements of detections in other bands. Here we report the first results of an astronomical transient survey with the South Pole Telescope (SPT) using the SPT-3G camera to observe 1500 deg 2 of the southern sky. The observations took place from 2020 March to November in three bands centered at 95, 150, and 220 GHz. This survey yielded the detection of 15 transient events from sources not previously detected by the SPT. The majority are associated with variable stars of different types, expanding the number of such detected flares by more than a factor of two. Additionally, the stellar flares are unpolarized and bright, in some cases exceeding 1 Jy, and have durations from a few minutes to several hours. Another population of detected events last for 2–3 weeks and appear to be extragalactic in origin. Though data availability at other wavelengths is limited, we find evidence for concurrent optical activity for two of the stellar flares. Future data from SPT-3G and forthcoming instruments will provide real-time detection of millimeter-wave transients on timescales of minutes to months.

79 ASTRONOMY AND ASTROPHYSICS↗

Aspects of Spodumene Lithium Extraction Techniques

Lithium (Li), a leading cathode material in rechargeable Li-ion batteries, is vital to modern energy storage technology, establishing it as one of the most impactful and strategical elements. Given the surge in the electric car market, it is crucial to improve lithium recovery from its rich mineral deposits using the most effective extraction technique. In recent years, both industry and academia have shown significant interest in Li recovery from various Li-bearing minerals. Of these, only extraction from spodumene has established a reliable industrial production of Li salts. The current approaches for cracking of the naturally occurring, stable α-spodumene structure into a more open structure—β-spodumene—involve the so-called decrepitation process that takes place at extreme temperatures of ~1100 °C. This conversion is necessary, as β-spodumene is more susceptible to chemical attacks facilitating Li extraction. In the last several decades, many techniques have been demonstrated and patented to process hard-rock mineral spodumene. The objective of this review is to present a thorough analysis of significant findings and the enhancement of process flowsheets over time that can be useful for both research endeavors and industrial process improvements. The review focuses on the following techniques: acid methods, alkali methods, carbonate roasting/autoclaving methods, sulfuric acid roasting/autoclaving methods, chlorinating methods, and mechanochemical activation. Recently, microwaves (MWs), as an energy source, have been employed to transform α-spodumene into β-spodumene. Considering its energy-efficient and short-duration aspects, the review discusses the interaction mechanism of MWs with solids, MW-assisted decrepitation, and Li extraction efficiencies. Finally, the merits and/or disadvantages, challenges, and prospects of the processes are summarized.

25 ENERGY STORAGE↗

Experimental Investigation of the Effects of Magnetic Mirrors on Plasma Transport in the Prototype Material Plasma Exposure Experiment

The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) at Oak Ridge National Laboratory is developing a helicon radio frequency (RF) source for plasma production along with microwave electron heating and RF ion heating. Proto-MPEX has several magnetic mirrors that affect plasma transport. The magnetic field near the helicon source is ~ 0.05 T, and the peak magnetic field in Proto-MPEX is ~ 1.8 T, which results in a large magnetic well for particles sourced at the helicon transporting toward the target region. Keeping the helicon source field and the target field constant, experiments have been conducted by methodically changing the magnetic field, at a local axial location, within the source and the target. Plasma flow measurements using Mach probes have shown a decrease in the flow as a function of the magnetic mirror ratio. Plasma flows were further investigated with ion cyclotron resonant heating (ICH). Results with the addition of ICH measured upstream of the antenna have shown a decrease in Mach number as a function of mirror ratio when compared to helicon discharges. Such flow behavior demonstrated slowing down of the plasma due to the increased reverse plasma flow toward the helicon plasma source. However, in high magnetic fields, when the resonant magnetic field moved away from the ICH antenna, no effects on the plasma flow due to ICH were observed.

Kafle, Nischal↗

Developing a microwave-driven reactor for ammonia synthesis: insights into the unique challenges of microwave catalysis

Rapid development of new ammonia (NH 3 ) synthesis techniques that enable modular, intermittent production is essential to actualizing NH 3 's potential as a clean energy carrier, since contemporary methods are configured to centralized, continuous production methods with high emissions and are incompatible with renewable sources. Here, in this mission, microwave-driven catalysis is promising for its ability to enhance reaction kinetics and apply targeted heating for efficient energy use. However, owing to an incomplete understanding of the interaction between microwave fields and catalyst beds, the development of such microwave-catalysis systems remains underexplored and challenging. This paper investigates the 10× scale-up of a microwave-based NH 3 synthesis reactor using numerical and experimental approaches, achieving the largest reported microwave-driven NH 3 reactor to date. Results elucidate phenomena unique to microwave processes that are only predictable through numerical modeling, including how a catalyst's dielectric properties influence microwave field distribution by affecting penetration depth and how energy utilization can be poor even with sufficient attenuation. These dynamics change with scale, constrain reactor geometry, and potentially hamper performance. Nonetheless, we demonstrate a production rate of 56.6 g NH$_3$ per day, the highest reported NH 3 synthesis rate for laboratory-scale alternative techniques; correspondingly, the benchmark energy efficiency achieved in this paper (45.6 g NH$_3$ kW h -1 ) is the highest reported for such reactors of sufficient scale. Even with this exemplary energy efficiency, energy losses were found in excess of 50%, an issue resolvable through scale and reactor design. The efficiencies imparted by microwaves were key in these achievements, warranting further investigation toward development of microwave-driven NH 3 systems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Apparatus and method to measure semiconductor optical absorption using microwave charge sensing

A time-resolved microwave reflectance apparatus comprises a pulsed or modulated optical source that irradiates a semiconductor sample with an excitation pump beam, a microwave oscillator that irradiates the sample with a continuous beam of microwaves, and a microwave detector that detects the microwaves reflected by the sample. Therefore, charge detection, rather than conventional absorption measurements (that detect the loss of photons), can be used to extract the absorption coefficient and band edge of a semiconductor material.

Shaner, Eric A.↗

The Atacama Cosmology Telescope: R eionization kSZ trispectrum methodology and limits

Patchy reionization generates kinematic Sunyaev–Zel’dovich (kSZ) anisotropies in the cosmic microwave background (CMB). Large-scale velocity perturbations along the line of sight modulate the small-scale kSZ power spectrum, leading to a trispectrum (or four-point function) in the CMB that depends on the physics of reionization. We investigate the challenges in detecting this trispectrum and use tools developed for CMB lensing, such as realization-dependent bias subtraction and cross-correlation based estimators, to counter uncertainties in the instrumental noise and assumed CMB power spectrum. We also find that both lensing and extragalactic foregrounds can impart larger trispectrum contributions than the reionization kSZ signal. We present a range of mitigation methods for both of these sources of contamination, validated on microwave-sky simulations. We use ACT DR6 and Planck data to calculate an upper limit on the reionization kSZ trispectrum from a measurement dominated by foregrounds. The upper limit is about 50 times the signal predicted from recent simulations.

cosmic background radiation↗

Sidelobe modeling and mitigation for a three mirror anastigmat cosmic microwave background telescope

Telescopes measuring cosmic microwave background (CMB) polarization on large angular scales require exquisite control of systematic errors to ensure the fidelity of the cosmological results. In particular, far-sidelobe contamination from wide angle scattering is a potentially prominent source of systematic error for large aperture microwave telescopes. Here we describe and demonstrate a ray-tracing-based modeling technique to predict far sidelobes for a three mirror anastigmat telescope designed to observe the CMB from the South Pole. Those sidelobes are produced by light scattered in the receiver optics subsequently interacting with the walls of the surrounding telescope enclosure. After comparing simulated sidelobe maps and angular power spectra for different enclosure wall treatments, we propose a highly scattering surface that would provide more than an order of magnitude reduction in the degree-scale far-sidelobe contrast compared to a typical reflective surface. Finally, we conclude by discussing the fabrication of a prototype scattering wall panel and presenting measurements of its angular scattering profile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Double source lensing probing high redshift cosmology

Double source lensing, with two sources lensed by the same foreground galaxy, involves the distance between each source and the lens and hence is a probe of the universe away from the observer. The double source distance ratio also reduces sensitivity to the lens model and has good complementarity with standard distance probes. We show that using this technique at high redshifts z > 1, to be enabled by data from the Euclid satellite and other surveys, can give insights on dark energy, both in terms of w 0 –w a and redshift binned density. We find a dark energy figure of merit of 245 from combination of 256 double source systems with moderate quality cosmic microwave background and supernova data. Using instead five redshift bins between z = 1.1–5, we could detect the dark energy density out to z ≈ 5, or make measurements ranging between 31σ and 2.5σ of its values in the bins.

79 ASTRONOMY AND ASTROPHYSICS↗

The Simons Observatory: impact of bandpass, polarization angle and calibration uncertainties on small-scale power spectrum analysis

We study the effects due to mismatches in passbands, polarization angles, and temperature and polarization calibrations in the context of the upcoming cosmic microwave background experiment Simons Observatory (SO). Using the SO multi-frequency likelihood, we estimate the bias and the degradation of constraining power in cosmological and astrophysical foreground parameters assuming different levels of knowledge of the instrumental effects. We find that incorrect but reasonable assumptions about the values ofall the systematics examined here can have significant effects on cosmologicalanalyses, hence requiring marginalization approaches at the likelihood level.When doing so, we find that the most relevant effect is due to bandpass shifts. When marginalizing over them, the posteriors of parameters describing astrophysical microwave foregrounds (such as radio point sources or dust) get degraded, while cosmological parameters constraints are not significantly affected.Marginalization over polarization angles with up to 0.25$^{°}$ uncertainty causes an irrelevant bias ≲ 0.05 σ in all parameters.Marginalization over calibration factors in polarization broadens the constraints on the effective number of relativistic degrees of freedom N$_{eff}$ by a factor 1.2, interpreted here as a proxy parameter for non standard model physics targeted by high-resolution CMB measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon Frequency Conversion in High-Q Superconducting Resonators: Axion Electrodynamics, QED, and Nonlinear Meissner Radiation

High-Q superconducting resonators have been proposed and developed as detectors of light-by-light scattering mediated by the hypothesized axion or virtual electron–positron pairs in quantum electrodynamics: the Euler–Heisenberg (EH) interaction. Photon frequency and mode conversion is central to the scheme for detecting such rare events. Superconducting resonators are nonlinear devices. The Meissner screening currents that confine the electromagnetic fields to the vacuum region of a superconducting RF cavity are nonlinear functions of the EM field at the vacuum–superconducting interface, and as a result can generate source currents and frequency conversion of microwave photons in the cavity. In this report we consider photon frequency and mode conversion in superconducting resonators with high quality factors from Meissner currents in single- and dual-cavity setups proposed for axion and QED searches based on light-by-light scattering. In a single cavity with two pump modes, photon frequency conversion by the Meissner screening current dominates photon generation by the EH interaction for cavities with Q≲1012⁠. The Meissner currents also generate background photons that limit the operation of the resonator for axion detection in three-mode, single-cavity setups. We also consider the leakage of photons from pump modes into the signal mode for both axion- and EH-mediated light-by-light scattering. Photon frequency conversion by the EH interaction can compete with Meissner and leakage radiation in ultra-high-Q cavities that are beyond the current state of the art. Meissner radiation and leakage backgrounds can be suppressed in dual-cavity setups with appropriate choices for pump and spectator modes, as well as the single-cavity setup proposed for heterodyne detection of galactic axion dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Signatures of primordial energy injection from axion strings

Axion strings are horizon-size topological defects that may be produced in the early Universe. Ultralight axion-like particles may form strings that persist to temperatures below that of big bang nucleosynthesis. Such strings have been considered previously as sources of gravitational waves and cosmic microwave background (CMB) polarization rotation. In this work we show, through analytic arguments and dedicated adaptive mesh refinement cosmological simulations, that axion strings deposit a subdominant fraction of their energy into high-energy Standard Model (SM) final states, for example, by the direct production of heavy radial modes that subsequently decay to SM particles. This high-energy SM radiation is absorbed by the primordial plasma, leading to novel signatures in precision big bang nucleosynthesis, the CMB power spectrum, and gamma-ray surveys. In particular, we show that CMB power spectrum data constrains axion strings with decay constants f a ≲ 10 12 GeV , up to model dependence on the ultraviolet completion, for axion masses m a ≲ 10 − 29 eV ; future CMB surveys could find striking evidence of axion strings with lower decay constants. Published by the American Physical Society 2024

79 ASTRONOMY AND ASTROPHYSICS↗

Frequency comb ptychoscopy

Multiheterodyne techniques using frequency combs—radiation sources whose lines are perfectly evenly-spaced—have revolutionized science. By beating sources with the many lines of a comb, their spectra are recovered. Even so, these approaches are fundamentally limited to probing coherent sources, such as lasers. They are unable to measure most spectra that occur in nature. Here we present frequency comb ptychoscopy, a technique that allows for the spectrum of any complex broadband source to be retrieved using a comb. In this approach, the spectrum is reconstructed by unfolding the simultaneous beating of a source with each comb line. We demonstrate this both theoretically and experimentally, at microwave frequencies. This approach can reconstruct the spectrum of nearly any complex source to high resolution, and the speed, resolution, and generality of this technique will allow chip-scale frequency combs to have an impact in a wide swath of new applications, such as remote sensing and passive spectral imaging.

42 ENGINEERING↗

An upgraded frequency-selectable laser source (FLS) calibrator for CMB bandpass characterization

One of the biggest challenges for Cosmic Microwave Background (CMB) experiments comes from the uncertainty in instrument bandpass calibration. Uncertainties in bandpass can limit foreground removal and spectral fitting, which are critical for inflationary and galaxy cluster measurements. CMB experiments currently use Fourier Transform Spectrometers (FTSes) to measure instrument bandpasses. However, FTS systems are currently systematics-limited, so significant improvements in bandpass measurements require novel calibrators. To this end, we developed a Frequency-selectable Laser Source (FLS) calibrator, which uses a laser with adjustable frequency coupled to a system that allows for laser power attenuation. Following initial testing with the first FLS prototype, we developed an upgraded version of the calibrator with improved performance. We present the upgrades to the FLS calibrator, the characterization of the upgraded calibrator and new laser source, and plans for testing with microwave instruments in the field.

Saunders, Lauren J. [Fermilab] (ORCID:000000016367↗