Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microwave oscillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

High-Q Microsphere Cavity for Laser Stabilization and Optoelectronic Microwave

With submillimeter size and optical Q up to ~ 10(sup 10), microspheres with whispering-gallery (WG) modes are attractive new component for fiber-optics/photonics applications and a potential core in ultra-compact high-spectral-purity optical and microwave oscillators.

microspheres fiber optics microwave photonics↗

MMIC Replacement for Gunn Diode Oscillators

An all-solid-state replacement for high-frequency Gunn diode oscillators (GDOs) has been proposed for use in NASA s millimeter- and submillimeter-wave sensing instruments. Highly developed microwave oscillators are used to achieve a low-noise and highly stable reference signal in the 10-40-GHz band. Compact amplifiers and high-power frequency multipliers extend the signal to the 100-500-GHz band with minimal added phase noise and output power sufficient for NASA missions. This technology can achieve improved output power and frequency agility, while maintaining phase noise and stability comparable to other GDOs. Additional developments of the technology include: a frequency quadrupler to 145 GHz with 18 percent efficiency and 15 percent fixed tuned bandwidth; frequency doublers featuring 124, 240, and 480 GHz; an integrated 874-GHz subharmonic mixer with a mixer noise temperature of 3,000 K DSB (double sideband) and mixer conversion loss of 11.8 dB DSB; a high-efficiency frequency tripler design with peak output power of 23 mW and 14 mW, and efficiency of 16 and 13 percent, respectively; millimeter-wave integrated circuit (MMIC) power amplifiers to the 30-40 GHz band with high DC power efficiency; and an 874-GHz radiometer suitable for airborne observation with state-of-the-art sensitivity at room temperature and less than 5 W of total power consumption.

Crowe, Thomas W.↗

Improved Tracking of an Atomic-Clock Resonance Transition

An improved method of making an electronic oscillator track the frequency of an atomic-clock resonance transition is based on fitting a theoretical nonlinear curve to measurements at three oscillator frequencies within the operational frequency band of the transition (in other words, at three points within the resonance peak). In the measurement process, the frequency of a microwave oscillator is repeatedly set at various offsets from the nominal resonance frequency, the oscillator signal is applied in a square pulse of the oscillator signal having a suitable duration (typically, of the order of a second), and, for each pulse at each frequency offset, fluorescence photons of the transition in question are counted. As described below, the counts are used to determine a new nominal resonance frequency. Thereafter, offsets are determined with respect to the new resonance frequency. The process as described thus far is repeated so as to repeatedly adjust the oscillator to track the most recent estimate of the nominal resonance frequency.

Prestage, John D.↗

A New OEO Design Using Optical Phase Modulation and Modulation Suppression

We present the design for a phase-modulated Opto-Electronic Oscillator (OEO) that incorporates asymmetric Mach- Zehnder (AMZ) interferometers as phase demodulators together with PM modulation suppression. The new design promises to obtain in the electro-optical domain the low-noise advantages previously achieved in RF and microwave oscillators by the use of carrier suppression but which have been achieved only to a limited extent in OEO's.

oscillator↗

Ultra-stable performance of the superconducting cavity maser

Recent measurements on the superconducting cavity maser (SCM) oscillator show frequency stability of parts in 10 exp 15 for times from 1 to 1000 sec. Phase noise of approximately -80 dB/f-cubed was also measured. This short- and mid-term performance is believed to be better than that of any known microwave oscillator. In particular, stability at a measuring time of 1 sec is 10 times better than that of a hydrogen maser, and phase noise at 8 GHz is more than 20 dB below that of the best multiplied quartz crystal oscillators. Substantial technical improvements have been made to eliminate frequency instability due to operational parameters. They are temperature, pump frequency, pump power, pump frequency polarization, temperature gradient, coupling strength, and output VSWR. Either the parameter was stabilized or the coefficient which couples the parameter to the operating frequency was minimized. A frequency pulling coil has been implemented and tested to enable the SCM to be slaved to a hydrogen maser with a time constant of approximately 50 sec. This combination would allow the excellent long term performance of the hydrogen maser to be improved by the newly available short term performance of the SCM.

Dick, G. J.↗

NASA Tech Briefs, November 2009

Topics covered include: Cryogenic Chamber for Servo-Hydraulic Materials Testing; Apparatus Measures Thermal Conductance Through a Thin Sample from Cryogenic to Room Temperature; Rover Attitude and Pointing System Simulation Testbed; Desktop Application Program to Simulate Cargo-Air-Drop Tests; Multimodal Friction Ignition Tester; Small-Bolt Torque-Tension Tester; Integrated Spacesuit Audio System Enhances Speech Quality and Reduces Noise; Hardware Implementation of a Bilateral Subtraction Filter; Simple Optoelectronic Feedback in Microwave Oscillators; Small X-Band Oscillator Antennas; Free-Space Optical Interconnect Employing VCSEL Diodes; Discrete Fourier Transform Analysis in a Complex Vector Space; Miniature Scroll Pumps Fabricated by LIGA; Self-Assembling, Flexible, Pre-Ceramic Composite Preforms; Flight-speed Integral Image Analysis Toolkit; Work Coordination Engine; Multi-Mission Automated Task Invocation Subsystem; Autonomously Calibrating a Quadrupole Mass Spectrometer; Determining Spacecraft Reaction Wheel Friction Parameters; Composite Silica Aerogels Opacified with Titania; Multiplexed Colorimetric Solid-Phase Extraction; Detecting Airborne Mercury by Use of Polymer/Carbon Films; Lattice-Matched Semiconductor Layers on Single Crystalline Sapphire Substrate; Pressure-Energized Seal Rings to Better Withstand Flows; Rollerjaw Rock Crusher; Microwave Sterilization and Depyrogenation System; Quantifying Therapeutic and Diagnostic Efficacy in 2D Microvascular Images; NiF2/NaF:CaF2/Ca Solid-State High-Temperature Battery Cells; Critical Coupling Between Optical Fibers and WGM Resonators; Microwave Temperature Profiler Mounted in a Standard Airborne Research Canister; Alternative Determination of Density of the Titan Atmosphere; Solar Rejection Filter for Large Telescopes; Automated CFD for Generation of Airfoil Performance Tables; Progressive Classification Using Support Vector Machines; Active Learning with Irrelevant Examples; A Data Matrix Method for Improving the Quantification of Element Percentages of SEM/EDX Analysis; Deployable Shroud for the International X-Ray Observatory; Improved Model of a Mercury Ring Damper; Optoelectronic pH Meter: Further Details; X-38 Advanced Sublimator; and Solar Simulator Represents the Mars Surface Solar Environment.

Source record↗

High efficiency compact microwave sources using electrostatic potential depression

In this article, we report theoretical and design studies on the application of an electrostatic potential depression (EPD) on two types of traditional microwave sources, the klystron and the inductive output tube (IOT), both operating in the UHF band. Additionally, the EPD is implemented by a section of the metallic beam pipe on which a direct current (dc) negative high voltage is applied. Inside the EPD section, the modulated electron beam develops into bunches over a very short longitudinal distance, indicating a possible design approach for a compact device. With the application of an EPD, the peak value of the first harmonic current in a microwave tube can be further increased compared to that in a conventional design, suggesting higher circuit efficiency. As the electron beam leaves the EPD section, the reacceleration of the beam provides a longitudinal cooling effect. With the addition of an EPD, circuit power extraction efficiency above 80% is achieved in both the modified design of the IOT and the novel conceptual circuit design of the klystron.

42 ENGINEERING↗

Stability Boundaries of Discharges Generated in the Focal Region of a CW Microwave Beam

Plasma was generated in the focal region of a multikilowatt, 4.7-GHz continuous-wave (CW) microwave beam far removed from the walls of the vacuum chamber, minimizing the nonideal effects associated with plasma-wall and beam-wall interactions. Experiments were conducted with gas mixtures of argon, nitrogen, and oxygen at gas pressures ranging from 100 to 200 mtorr. Furthermore, three types of discharges were observed during these experiments: unstable, quasi-stable, and stable discharges. It was determined that the stability of the discharges could be controlled through adjustments of the gas composition, gas pressure, and power of the microwave beam. This article reports on the operational conditions in which stable discharges were achieved and the general behavior of these discharges as the control parameters were varied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multichannel VCO needs only one reference

Frequency stabilizing circuit controls output of multichannel microwave oscillator using passband filters and selector logic to eliminate need for separate crystal diode voltage controlled oscillator (VCO).

Masson, R. K.↗

Active CPW-fed slot antennas for power combining applications

We have combined integrated circuit antenna technology with microwave oscillator design to build an active slot-oscillator. The design is planar, does not require via holes and is compatible with monolithic transistor technology. The CPW-fed antenna impedance is calculated using a full-wave analysis technique. Slot-oscillators were built at 7, 13, and 22 GHz, and the predicted oscillation frequencies agree well with experiments. The design is easily scaled to millimeter-wave frequencies and can be extended to power combining arrays.

Kormanyos, Brian K.↗

Electrochemical Deposition Of Thiolate Monolayers On Metals

Electrochemical method devised for coating metal (usually, gold) surfaces with adherent thiolate monolayers. Affords greater control over location and amount of material deposited and makes it easier to control chemical composition of deposits. One important potential use for this method lies in fabrication of chemically selective thin-film resonators for microwave oscillators used to detect pollutants: monolayer formulated to bind selectively pollutant chemical species of interest, causing increase in mass of monolayer and corresponding decrease in frequency of resonance. Another important potential use lies in selective chemical derivatization for purposes of improving adhesion, lubrication, protection against corrosion, electrocatalysis, and electroanalysis.

Porter, Marc D.↗

Microwave Resonators Containing Diamond Disks

Synthetic diamond dielectric bodies proposed for use in cylindrical resonators helping to stabilize frequencies of some microwave oscillators. Acting in conjunction with metal resonator cavities in which mounted, such dielectric bodies support "whispering-gallery" waveguide modes characterized by desired frequencies of resonance and by electro-magnetic-field configurations limiting dissipation of power on metal surfaces outside dielectric bodies. Performances at room temperature might exceed those of liquid-nitrogen-cooled sapphire-based resonators.

Dick, G. John↗

The Low Temperature Microgravity Physics Facility: Progress and Status

The Jet Propulsion Laboratory (JPL) is developing the Low Temperature Microgravity Physics Facility (LTMPF). The LTMPF is a multiple user and multiple flight facility that will provide a long duration low temperature environment for performing state of the art experiments at the International Space Station (ISS). During each mission, two distinct primary experiments will be accommodated. Secondary experiments utilizing the hardware built for the primary experiments will also be accommodated during each mission. Over the past year, much progress has occurred on the LTMPF as the flight hardware has started to be built. Also, many changes have occurred. Last summer, the initial flight of the LTMPF was delayed until early 2008 by a 2-year slip in the delivery of the Japanese Experiment Module (KIBO) Exposed Facility of the ISS, where the LTMPF will be attached when it flies. Finally, the experiments that will fly as part of the first mission have been changed so that one Gravitational and Relativistic experiment and one Low Temperature Condensed Matter experiment will fly on each flight of the LTMPF. Therefore, the experiments that will fly on the initial mission of the LTMPF will be DYNAMX and the Superconducting Microwave Oscillator Experiment (SUMO).

Larson, Melora↗

Photonic frequency synthesis and control with Whispering Gellery Mode microresonators

We report here on experimental and theorectical studies of electro-optical tunability of WGM's in high-Q monolithic lithium niobate resonators and applicability of such resonators for light modulation and filtering. Properties of an optoelectronic microwave oscillator (EOE) based on an WGM LiNbO3 resonator are discussed.

Whispering Gallery Modes↗

NASA Tech Briefs, December 2005

Topics covered include: Video Mosaicking for Inspection of Gas Pipelines; Shuttle-Data-Tape XML Translator; Highly Reliable, High-Speed, Unidirectional Serial Data Links; Data-Analysis System for Entry, Descent, and Landing; Hybrid UV Imager Containing Face-Up AlGaN/GaN Photodiodes; Multiple Embedded Processors for Fault-Tolerant Computing; Hybrid Power Management; Magnetometer Based on Optoelectronic Microwave Oscillator; Program Predicts Time Courses of Human/ Computer Interactions; Chimera Grid Tools; Astronomer's Proposal Tool; Conservative Patch Algorithm and Mesh Sequencing for PAB3D; Fitting Nonlinear Curves by Use of Optimization Techniques; Tool for Viewing Faults Under Terrain; Automated Synthesis of Long Communication Delays for Testing; Solving Nonlinear Euler Equations With Arbitrary Accuracy; Self-Organizing-Map Program for Analyzing Multivariate Data; Tool for Sizing Analysis of the Advanced Life Support System; Control Software for a High-Performance Telerobot; Java Radar Analysis Tool; Architecture for Verifiable Software; Tool for Ranking Research Options; Enhanced, Partially Redundant Emergency Notification System; Close-Call Action Log Form; Task Description Language; Improved Small-Particle Powders for Plasma Spraying; Bonding-Compatible Corrosion Inhibitor for Rinsing Metals; Wipes, Coatings, and Patches for Detecting Hydrazines; Rotating Vessels for Growing Protein Crystals; Oscillating-Linear-Drive Vacuum Compressor for CO2; Mechanically Biased, Hinged Pairs of Piezoelectric Benders; Apparatus for Precise Indium-Bump Bonding of Microchips; Radiation Dosimetry via Automated Fluorescence Microscopy; Multistage Magnetic Separator of Cells and Proteins; Elastic-Tether Suits for Artificial Gravity and Exercise; Multichannel Brain-Signal-Amplifying and Digitizing System; Ester-Based Electrolytes for Low-Temperature Li-Ion Cells; Hygrometer for Detecting Water in Partially Enclosed Volumes; Radio-Frequency Plasma Cleaning of a Penning Malmberg Trap; Reduction of Flap Side Edge Noise - the Blowing Flap; and Preventing Accidental Ignition of Upper-Stage Rocket Motors.

Source record↗

Terahertz local oscillator for the Microwave Limb Sounder on the Aura satellite

The Microwave Limb Sounder on the Aura satellite has a radiometer at 2.5 THz to perform global mapping of OH in the atmosphere. The OH radiometer utilizes two Schottky-diode mixers pumped by an optically pumped THz gas laser local oscillator. The laser was first turned on in space on July 22, 2004, and has performed without issue for more than 30 months. The specifications, design, and modeling of this 2.5 THz laser local oscillator are presented here, along with some of the important design validation and test results.

Pickett, Herbert M.↗

BICEP/ Keck XII: Constraints on axionlike polarization oscillations in the cosmic microwave background

Here, we present a search for axionlike polarization oscillations in the cosmic microwave background (CMB) with observations from the Keck Array . A local axion field induces an all-sky, temporally sinusoidal rotation of CMB polarization. A CMB polarimeter can thus function as a direct-detection experiment for axionlike dark matter. We develop techniques to extract an oscillation signal. Many elements of the method are generic to CMB polarimetry experiments and can be adapted for other datasets. As a first demonstration, we process data from the 2012 observing season to set upper limits on the axion-photon coupling constant in the mass range 10 – 21 – 10 – 18 eV , which corresponds to oscillation periods on the order of hours to months. We find no statistically significant deviations from the background model. For periods larger than 24 hr (mass m < 4.8 × 10 – 20 eV ), the median 95% confidence upper limit is equivalent to a rotation amplitude of 0.68°, which constrains the axion-photon coupling constant to g Φ γ < ( 1.1 × 10 – 11 GeV – 1 ) m / ( 10 – 21 eV ) , if axionlike particles constitute all of the dark matter. The constraints can be improved substantially with data already collected by the BICEP series of experiments. Current and future CMB polarimetry experiments are expected to achieve sufficient sensitivity to rule out unexplored regions of the axion parameter space.

79 ASTRONOMY AND ASTROPHYSICS↗

BICEP/ K e c k XIV: Improved constraints on axionlike polarization oscillations in the cosmic microwave background

We present an improved search for axionlike polarization oscillations in the cosmic microwave background (CMB) with observations from the Keck Array . An all-sky, temporally sinusoidal rotation of CMB polarization, equivalent to a time-variable cosmic birefringence, is an observable manifestation of a local axion field and potentially allows a CMB polarimeter to detect axionlike dark matter directly. We describe improvements to the method presented in previous work, and we demonstrate the updated method with an expanded dataset consisting of the 2012–2015 observing seasons. We set limits on the axion-photon coupling constant for mass m in the range 10 - 23 – 10 - 18 eV , which corresponds to oscillation periods on the order of hours to years. Our results are consistent with the background model. For periods between 1 and 30 d ( 1.6 × 10 - 21 ≤ m ≤ 4.8 × 10 - 20 eV ), the 95%-confidence upper limits on rotation amplitude are approximately constant with a median of 0.27°, which constrains the axion-photon coupling constant to g φ γ < ( 4.5 × 10 - 12 GeV - 1 ) m / ( 10 - 21 eV ) , if axionlike particles constitute all of the dark matter. More than half of the collected BICEP dataset has yet to be analyzed, and several current and future CMB polarimetry experiments can apply the methods presented here to achieve comparable or superior constraints. In the coming years, oscillation measurements can achieve the sensitivity to rule out unexplored regions of the axion parameter space.

79 ASTRONOMY AND ASTROPHYSICS↗