Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microneedle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

43 records · Page 3

Printing of small molecular medicines from the vapor phase

There is growing need to develop efficient methods for early-stage drug discovery, continuous manufacturing of drug delivery vehicles, and ultra-precise dosing of high potency drugs. Here we demonstrate the use of solvent-free organic vapor jet printing to deposit nanostructured films of small molecular pharmaceutical ingredients, including caffeine, paracetamol, ibuprofen, tamoxifen, BAY 11-7082 and fluorescein, with accuracy on the scale of micrograms per square centimeter, onto glass, Tegaderm, Listerine tabs, and stainless steel microneedles. The printed films exhibit similar crystallographic order and chemistry as the original powders; controlled, order-of-magnitude enhancements of dissolution rate are observed relative to powder-form particles. In vitro treatment of breast and ovarian cancer cell cultures in aqueous media by tamoxifen and BAY 11-7082 films shows similar behavior to drugs pre-dissolved in dimethyl sulfoxide. In conclusion, the demonstrated precise printing of medicines as films, without the use of solvents, can accelerate drug screening and enable continuous manufacturing, while enhancing dosage accuracy.

60 APPLIED LIFE SCIENCES↗

Direct conversion of h-BN into c-BN and formation of epitaxial c-BN/diamond heterostructures

We have created a new state of BN (named Q-BN) through rapid melting and super undercooling and quenching by using nanosecond laser pulses. Phase pure c-BN is formed either by direct quenching of super undercooled liquid or by nucleation and growth from Q-BN. Thus, a direct conversion of hexagonal boron nitride (h-BN) into phase-pure cubic boron nitride (c-BN) is achieved by nanosecond pulsed laser melting at ambient temperatures and atmospheric pressure in air. According to the P-T phase diagram, the transformation from h-BN into c-BN under equilibrium processing can occur only at high temperatures and pressures, as the hBN-cBN-Liquid triple point is at 3500 K/9.5 GPa or 3700 K/7.0 GPa with a recent theoretical refinement. Using nonequilibrium nanosecond laser melting, we have created super undercooled state and shifted this triple point to as low as 2800 K and atmospheric pressure. The rapid quenching from super undercooled state leads to the formation of a new phase, named as Q-BN. We present detailed characterization of Q-BN and c-BN layers by using Raman spectroscopy, high-resolution scanning electron microscopy, electron-back-scatter diffraction, high-resolution TEM, and electron energy loss spectroscopy, and discuss the mechanism of formation of nanodots, nanoneedles, microneedles, and single-crystal c-BN on sapphire substrate. We have also deposited diamond by pulsed laser deposition of carbon on c-BN and created c-BN/diamond heterostructures, where c-BN acts as a template for epitaxial diamond growth. We discuss the mechanism of epitaxial c-BN and diamond growth on lattice matching c-BN template under pulsed laser evaporation of amorphous carbon, and the impact of this discovery on a variety of applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Host-Directed, Bioelectronic Immunomodulation for Protection Against Emerging Pathogens

Acute care of patients with severe infections often relies on systemic administration of pharmaceuticals and monitoring of complex physiological symptoms to identify immune system dysfunction, which can lead to increased mortality. Furthermore, determining disease-specific treatment plans often leads to a delay in patient care. To address this, we proposed an immune modulation system that electrically detects and responds to a patient’s immune system status, creating an agnostic means of treating illness and infection. Two pieces of hardware were developed for this task: a minimally-invasive sensor and a vagus nerve stimulator. Stimulation of the vagus nerve is known to modulate the immune system. The sensor is a microfabricated, silicon-based microneedle array capable of interfacing with interstitial fluid to detect small molecules such as inflammatory proteins (cytokines) and pharmaceuticals (vancomycin). Process optimization to manufacture the needles refined the silicon etch process, creating needle patches long enough to penetrate skin and reach interstitial fluid. The needles were tested for mechanical strength and stability, and did not shatter when inserted into skin models. The needles are coated with a thin film metal, turning them into electrodes for electrochemical sensing of our target molecules. We hybridized aptamers to the surface of the electrode to act as the sensing layer and were able to detect changes in the conformation of the aptamer electrochemically in the presence of the target molecule. The stimulator was a cuff electrode that encircled the vagus nerve. Rodent studies were conducted in which rodents were exposed to an inflammatory event and vagus nerve stimulation (VNS) was applied. It was demonstrated that optimized electrical stimulation of the vagus nerve created measurably different levels of cytokines in blood samples, and certain cytokines released during the inflammatory event were either upregulated or downregulated. In sum, this project successfully developed new platforms and technologies that can, with further development, enable better temporal insight into biomarker changes in the body, letting healthcare providers know of possible immune system dysfunction before they are detected physiologically. We also demonstrated the value of VNS and its possible use in treating immune system response to inflammation and illness.

59 BASIC BIOLOGICAL SCIENCES↗

Tensile stress stimulates microtubule outgrowth in living cells

Cell motility is driven by the sum of asymmetric traction forces exerted on the substrate through adhesion foci that interface with the actin cytoskeleton. Establishment of this asymmetry involves microtubules, which exert a destabilising effect on adhesion foci via targeting events. Here, we demonstrate the existence of a mechano-sensing mechanism that signals microtubule polymerisation and guidance of the microtubules towards adhesion sites under increased stress. Stress was applied either by manipulating the body of cells moving on glass with a microneedle or by stretching a flexible substrate that cells were migrating on. We propose a model for this mechano-sensing phenomenon whereby microtubule polymerisation is stimulated and guided through the interaction of a microtubule tip complex with actin filaments under tension.

NASA Discipline Cell Biology↗

Spaceflight Autonomous Multigenerational Microbial Sequencer (SAMMS) in Support of Plant-Growth Systems

As the National Aeronautics and Space Association (NASA) begins to pursue long-duration space flights, they will need to be able to provide astronauts with a nutritious and reliable food source. To meet the administration’s goal of traveling to the Moon and Mars, astronauts will need to begin to grow their own food in space. To protect their food source, extensive monitoring will occur to test for the effects of a space flight environment (e.g., radiation) as well as for early pathogen and disease detection. Genomic sequencing allows for both concerns to be tested on a regular basis. However, NASA’s current sequencer is unable to process plant tissues. Therefore, a novel method for plant DNA extraction using microneedle (MN) patches that will be able to feed into NASA’s existing system, but also require minimal human input is proposed. To support this, the design was broken down into four components (1) MN patch fabrication (2) MN patch extraction, (3) automated sampling motion control, and (4) a processing module. The MN patch is fabricated using a custom mold with conically shaped needles. The mold is filled with Polyvinyl alcohol (PVA) solution and placed in a vacuum desiccator. The mold is left in the vacuum overnight until the patch is dry and ready for use. The protocol was tested with varying pressures, drying times, volume amounts, and preparation methods to determine if highquality needles can be produced. A MN is a method of DNA extraction where the patch is applied to a leaf, the needles penetrate the leaf, breaking the rigid plant cell wall to isolate the DNA. A protocol for this method of extraction was tested to ensure the patch could produce the needed yield and purity. The tests varied by the number of patches, number of applications, and plant type. To automate the MN extraction method, motion control will utilize two separate axis tables which move in the x and y directions. The y-axis table will have an end effector that fits a MN patch and will have the ability to apply the patch to the leaf sample. This end effector will also act as a lid for a downstream processing module. The other axis will position the leaf sample and processing container so that the patch can be applied accurately. The Joint Comprehensive Sequencing System (JCSS) module integrates all the components together. The output of this module feeds into the NASA Charged Information-Storage Polymer Preparation System (CHIPPS) for genomic sequencing. The extraction module operates using a series of syringes and tubing to pump the varying reagents needed for the extraction protocol. The results of the study proved that MN patches are a viable method of DNA extraction. While fabrication of high-quality needles was unsuccessful, the protocol was able to be further developed using centrifugation. The integrated design between the motion control and the JCSS enabled the potential for automation with a complete conceptual design and prototype. Future research and development for this study would include (1) further testing for fabrication (2) expanding the range of plant species compatible with the MN patch, and (3) building a working prototype for the integrated system.

Peter Ling↗

Miniature sensors with probe insertable into and for obtaining measurements from plants and a variety of other mediums

Apparatus, methods, and systems for transducing measurements from a medium of interest. One non-limiting example is in planta monitoring of plants. In one aspect, a micro- or nano-scale probe body includes one or more microprobes (e.g. microneedles or waveguides) to access desired plant tissue, and one or more microsensors on the probe body. A microcircuit on or in the probe body transduces relevant measurements from the microsensor(s). An output interface allows storage, communication, or transfer of the transduced measurement for further use. Non-limiting examples are processing into estimations of chemical concentrations or the like for biochemical sensing. As such, if used as in planta sensors, they can be minimally invasive and cost effective for both single use and use in sets for plural plants with one central station.

Dong, Liang↗

Miniature sensors with probe insertable into and for obtaining measurements from plants and a variety of other mediums

Apparatus, methods, and systems for transducing measurements from medium of interest. One non-limiting example is in planta monitoring of plants. In one aspect, a micro- or nano-scale probe body includes one or more microprobes (e.g. microneedles or waveguides) to access desired plant tissue, and one or more microsensors on the probe body. A microcircuit on or in the probe body transduces relevant measurements from the microsensor(s). An output interface allows storage, communication, or transfer of the transduced measurement for further use. Non-limiting examples are processing into estimations of chemical concentrations or the like for biochemical sensing. As such, if used as in planta sensors, they can be minimally invasive and cost effective for both single use and use in sets for plural plants with one central station.

Dong, Liang↗