A review of functions, attributes, properties and measurements for the quality control of proton exchange membrane fuel cell components

Quality control (QC) is an essential part of fuel cell technology industrialization, providing means to reduce cost of components, enhancing the reliability of the final product, and offering specification guidance for new entrants in the supply chain. The membrane electrode assembly (MEA), including membrane, catalyst layer (CL), and gas diffusion layer (GDL), as well as bipolar plate (BP), are key components of a proton exchange membrane (PEM) fuel cell, and the attributes of each component strongly correlate with the cell performance and longevity. To ensure the quality of the fuel cell, it is of great importance to characterize the properties with respect to the standardization of component/sub-component specifications. In collaboration with the fuel cell industry, this work aims at establishing compendiums of attributes, or so-called books of attributes, of key fuel cell components for the QC of PEM fuel cells through reviewing, identifying, categorizing, and prioritizing the main attributes/properties that determine their functionalities. The books of attributes for the major PEM fuel cell components include catalyst coated membrane (CCM) as a sub-assembly, GDL, and BP. To address the full spectrum of fuel cell components, gaskets and sub-gaskets are also included.

25 ENERGY STORAGE↗

Nanostructured catalyst supports

The present invention relates to SiC nanostructures, including SiC nanopowder, SiC nanowires, and composites of SiC nanopowder and nanowires, which can be used as catalyst supports in membrane electrode assemblies and in fuel cells. The present invention also relates to composite catalyst supports comprising nanopowder and one or more inorganic nanowires for a membrane electrode assembly.

30 DIRECT ENERGY CONVERSION↗

Mitigation and Diagnosis of Pin-Hole Formation in Polymer Electrolyte Membrane Fuel Cells

In this work, we implement a calendering technique to flatten stray fibers within the gas diffusion media, thereby mitigating pin-hole formation in the hot-pressed MEAs. We have investigated the influence of calendering on the long-term durability for several types of gas diffusion electrodes (GDEs) using a combined chemical and mechanical accelerated stress test (AST). The calendered MEAs demonstrate an average AST lifetime improvement of 77% relative to the as-fabricated MEAs.

AMR↗

High-Performance AEM LTE with Advanced Membranes, Ionomers and PGM-Free Electrodes

Alkaline low temperature electrolysis (LTE) systems enjoy several potential advantages over acid-based LTE systems including facile oxygen evolution reaction (OER) kinetics and electrodes that can use little to no platinum group metals (PGM). The polymer membranes and membrane electrode assembly (MEA) structures going into alkaline electrochemical systems have seen significant advances in recent years. The objective of this project is to combine state-of-the-art alkaline polymer electrolyzer components into one optimized membrane electrode assembly (MEA) system to achieve DOE low temperature electrolysis (LTE) goals. The benefit of individual component advances cannot be fully appreciated until all aspects and components of the MEA are working at an equally high level of performance. New electrode fabrication methods were developed where solvent cast catalyst/ionomer solutions were used in place of insoluble ionomers to significantly improve adhesion. The membranes were improved in terms of durability and mechanical properties. The OER and HER catalysts were improved and made more durable.

08 HYDROGEN↗

Controlling Mass Transport in Direct Carbon Dioxide Zero-Gap Electrolyzers via Cell Compression

The development of high-performance CO 2 electrolyzers is crucial for accelerating the sustainable production of fuels and chemicals integrated with renewable energy sources. Here, we introduce a methodology to actively control mass transport inside a realistic zero-gap membrane electrode assembly of a CO 2 electrolyzer by varying the gasket thickness, which consequently changes the cell compression. This allows control over the thickness and porosity of the gas diffusion electrodes, influencing the overall electrolyzer performance, as demonstrated using Ag-deposited electrodes. At low operating voltages (<2.9 V), both high- and low-compression electrolyzers exhibit similar faradaic efficiencies and partial current densities for CO formation. However, at high voltages, the low-compression electrolyzer with high electrode porosity demonstrates superior CO selectivity and activity with suppressed H 2 formation. These experimental results are validated by the computational membrane electrode assembly (MEA) model developed by using the measured in situ electrode thicknesses and electrode porosities. Additionally, liquid electrolyte saturation at the catalyst layer is found to play a dominant role in determining the mass transport, resulting in a decreased electrolyzer performance with low electrode porosity. Finally, the systematic investigation in this study improves the understanding of the transport dynamics in MEA-based devices and provides insights into optimizing device design parameters for industry-relevant CO 2 electrolysis.

30 DIRECT ENERGY CONVERSION↗

Modeling ammonia-fueled co-flow dual-channel protonic-ceramic fuel cells

This paper reports the model development for a dual-channel protonic-ceramic fuel cell (PCFC) operating on ammonia fuel. The model considers the coupled interactions of several physical and chemical processes, including three-dimensional heat conduction within the bipolar plates and the membrane-electrode assembly (MEA), one-dimensional flow within the fuel and air channels, detailed heterogeneous catalytic reactions within the porous composite anode structure, Butler–Volmer representation of the charge-transfer chemistry, and Nernst–Planck transport of three charged defects (protons, oxygen vacancies, and small polarons) within the dense electrolyte membrane. The membrane-electrode assembly is composed of a Ni-BCZYYb (BaCe 0.7 Zr 0.1 Y 0.1 Yb 0.1 O 3-δ ) anode, a BCZYYb electrolyte membrane, and a BCFZY (BaCo 0.4 Fe 0.4 Zr 0.1 Y 0.1 O 3-δ ) cathode. Chemical and physical parameters for the MEA model are established using previously published button-cell data. One aspect of the study is to investigate the partial ammonia decomposition upstream of the fuel cell. Such fuel cracking increases the H 2 content of the fuel entering the PCFC, which may have benefits. However, endothermic ammonia pyrolysis within the composite anode structure assists with thermal control of the cell. The dual-channel model can be considered as the unit cell of a full fuel-cell stack.

25 ENERGY STORAGE↗

Degradation Effects at the Porous Transport Layer/Catalyst Layer Interface in Polymer Electrolyte Membrane Water Electrolyzer

The porous transport layer (PTL)/catalyst layer (CL) interface plays a crucial role in the achievement of high performance and efficiency in polymer electrolyte membrane water electrolyzers (PEMWEs). This study investigated the effects of the PTL/CL interface on the degradation of membrane electrode assemblies (MEAs) during a 4000 h test, comparing the MEAs assembled with uncoated and Ir-coated Ti PTLs. Our results show that compared to an uncoated PTL/CL interface, an optimized interface formed when using a platinum group metal (PGM) coating, i.e., an iridium layer at the PTL/CL interface, and reduced the degradation of the MEA. The agglomeration and formation of voids and cracks could be found for both MEAs after the long-term test, but the incorporation of an Ir coating on the PTL did not affect the morphology change or oxidation of IrO x in the catalyst layer. In addition, our studies suggest that the ionomer loss and restructuring of the anodic MEA can also be reduced by Ir coating of the PTL/CL interface. Optimization of the PTL/CL interface improves the performance and durability of a PEMWE.

30 DIRECT ENERGY CONVERSION↗

High-Current Density Durability of Pt/C and PtCo/C Catalysts at Similar Particle Sizes in PEMFCs

The durability of carbon supported PtCo-alloy based nanoparticle catalysts play a key role in the longevity of proton-exchange membrane fuel cells (PEMFC) in electric vehicle applications. To improve its durability, it is important to understand and mitigate the various factors that cause PtCo-based cathode catalyst layers (CCL) to lose performance over time. These factors include i) electrochemical surface area (ECSA) loss, ii) specific activity loss, iii) H + /O 2 -transport changes and iv) Co 2+ contamination effects. We use a catalyst-specific accelerated stress test (AST) voltage cycling protocol to compare the durability of Pt and PtCo catalysts at similar average nanoparticle size and distribution. Our studies indicate that while Pt and PtCo nanoparticle catalysts suffer from similar magnitudes of electrochemical surface area (ECSA) losses, PtCo catalyst shows a significantly larger cell voltage loss at high current densities upon durability testing. The distinctive factor causing the large cell voltage loss of PtCo catalyst appears to be the secondary effects of the leached Co 2+ cations that contaminate the electrode ionomer. A 1D performance model has been used to quantify the cell voltage losses arising from various factors causing degradation of the membrane electrode assembly (MEA).

08 HYDROGEN↗

Revealing in-plane movement of platinum in polymer electrolyte fuel cells after heavy-duty vehicle lifetime

Fuel cell heavy-duty vehicles (HDVs) require increased durability of oxygen-reduction-reaction electrocatalysts, making knowledge of realistic degradation mechanisms critical. Here identical-location micro-X-ray fluorescence spectroscopy was performed on membrane electrode assemblies. The results exposed heavy in-plane movement of electrocatalyst after HDV lifetime, suggesting that electrochemical Ostwald ripening may not be a local effect. Development of local loading hotspots and preferential movement of electrocatalyst away from cathode catalyst layer cracks was observed. The heterogeneous degradation exhibited by a modified cathode gas diffusion layer membrane electrode assembly after HDV lifetime was successfully quantified by the identical-location approach. Further synchrotron micro-X-ray diffraction and micro-X-ray fluorescence experiments were performed to obtain the currently unknown correlation between electrocatalyst nanoparticle size increase and loading change. A direct correlation was discovered which developed only after HDV lifetime. Finally, the work provides a route to engineer immediate system-level mitigation strategies and to develop structured cathode catalyst layers with durable electrocatalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Amino-tethering synthesis strategy toward highly accessible sub-3-nm L1 0 -PtM catalysts for high-power fuel cells

Because of the poor accessibility of embedded active sites, platinum (Pt)-based electrocatalysts suffer from insufficient Pt utilization and mass transport in membrane electrode assemblies (MEAs), limiting their performance in polymer electrolyte membrane fuel cells. Here, we report a simple and universal approach to depositing sub-3-nm L1 0 -PtM nanoparticles over external surfaces of carbon supports through pore-tailored amino (NH 2 )-modification, which enables not only excellent activity for the oxygen reduction reaction, but also enhanced Pt utilization and mass transport in MEAs. Using a low loading of 0.10 mg Pt ∙cm -2 , the MEA of PtCo/KB-NH 2 delivered an excellent mass activity of 0.691 A∙mgPt -1 , a record-high power density of 0.96 W∙cm -2 at 0.67 V, and only a 30-mV drop at 0.80 A∙cm -2 after 30,000 voltage cycles, which meets nearly all targets set by the Department of Energy. Finally, this work provides an efficient strategy for designing advanced Pt-based electrocatalysts and realizing high-power fuel cells.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nanoporous Iridium Nanosheets for Polymer Electrolyte Membrane Electrolysis

The growth of the hydrogen economy is predicated on advancements in electrochemical energy technologies, with water electrolysis as a key component to the technological portfolio. Much of the focus on anode catalyst development for polymer electrolyte membrane water electrolyzers (PEMWE) is centered on activity as controlled by compositional and morphological impacts on reactant/intermediate/product adsorption. However, the effectiveness of this strategy is found to be limited upon integration of these materials into PEMWE membrane electrode assemblies (MEA). Regardless of catalyst activity, the combination of electrode inhomogeneity, ionomer integration, and high density of oxide-oxide interfaces yields significant performance losses associated with poor catalytic electrode conductivity. Here many of these limitations are addressed through the development of a unique catalyst morphology composed of nanoporous Ir nanosheets (npIr(x)-NS) that exhibit high catalytic activity for the anodic oxygen evolution reaction and superior electrode electronic conductivity in comparison to a commercial IrO2 nanoparticle catalyst. The utility of the npIr(x)-NS is demonstrated through incorporation into PEMWE MEAs where their performance exceeds that of commercial catalyst coated membranes at loadings as low as 0.06 mg(Ir) cm(-2) while exhibiting a negligible loss in performance following 50 000 accelerated stress test cycles.

Polymer Electrolyte Membrane Electrolysis↗

Challenges and strategies for probing the composite interface of PEM electrolyzers and fuel cells using operando AP-XPS

Left: cross-section schematic of a membrane electrode assembly, the working electrode changing state with applied potential. Center: the operando cell design that enables snapshot data acquisition during trajectory movement. Right: resulting spectra. Understanding the surface chemistry of electrocatalyst systems under operando conditions is central to revealing the electrocatalytic cell's working mechanisms. Determination of these catalytic processes on a molecular scale and the involved components is fundamental to streamlining material design for energy conversion and storage applications. X-ray photoelectron spectroscopy (XPS) is an established technique used to study the chemical and electronic states of materials. While the surface sensitivity of XPS is typically high, use of tender X-ray energies and technical advancements have allowed for the direct probing of solid–vapor and solid–liquid interfaces. However, protocols and documentation of experimental considerations for operando XPS probing of working electrolyzers and fuel cells remain scarce. Herein, we report an approach for the study of working polymer electrolyte membrane (PEM) electrolysis cells using ambient pressure X-ray photoelectron spectroscopy (AP-XPS). This approach directly probes the composite electrode surface on the membrane electrode assembly (MEA) in 100% relative humidity to establish a meaningful liquid layer for electrocatalysis. We carry out a systematic investigation from the cell constituent components to a fully assembled working operando electrolytic system and establish a method for AP-XPS study of the complex composite MEA, providing recommendations for data acquisition and component analysis.

Hamlyn, Rebecca↗

Characterization of a Sulfonated Poly(Ionic Liquid) Block Copolymer as an Ionomer for Proton Exchange Membrane Fuel Cells using Rotating Disk Electrode

Ionic liquid (IL) additives to both traditional and advanced oxygen reduction reaction (ORR) electrocatalysts have yielded remarkable improvements in catalyst performance and durability. However, incorporating ILs or IL-modified catalysts into the electrodes of a proton exchange membrane fuel cell (PEMFC) membrane electrode assembly (MEA) has proven to be challenging. Sulfonated poly(ionic liquid) block copolymers (S-PILBCP) present an opportunity to incorporate IL functionality directly into the ionomer, orthogonal to protonic conductivity. Here, we use a rotating disc electrode (RDE) to characterize the interface between a S-PILBCP and Pt catalyst in comparison to Nafion. Catalyst thin films prepared with S-PILBCP show an 80% improvement in the ORR activity over those containing Nafion. Thin films of S-PILBCP also show a significantly reduced degree of poisoning sulfonate adsorption on a Pt(111) surface in comparison to Nafion. Furthermore, these half-cell results provide useful insights that help to highlight the source of the impact of the S-PILBCP on PEMFC MEA performance.

25 ENERGY STORAGE↗

Tailoring electrode microstructure via ink content to enable improved rated power performance for platinum cobalt/high surface area carbon based polymer electrolyte fuel cells

Improvements in polymer electrolyte fuel cell (PEFC) electrode performance have primarily focused on catalyst and ionomer developments, marginalizing the importance of catalyst ink formulation. In this study, the effect of ink formulation is examined across a series of cathodes comprised of PtCo supported on high surface area carbon (PtCo/ HSC ) and Nafion ionomer using an array of in situ electrochemical and ex situ characterization techniques. In contrast to prior work on Pt/Vu systems, ink water content had little effect on the electrochemically determined ionomer coverage for the PtCo/HSC electrocatalyst examined here. Characterization using nano-scale resolution X-ray computed tomography (nano-CT) demonstrated that water-rich ink formulations lead to a reduction in aggregate size (ionomer + PtCo/HSC), improving local O 2 transport. This understanding, combined with the use of a commercially-available electrocatalyst was used to produced state-of-the-art membrane electrode assemblies with Pt loadings of 0.03/0.08 mg Pt /cm 2 on the anode and cathode respectively, having; i) > 1 A/mg Pt (0.9 V iR-free , 150 kPa, 80 °C, 100% RH, H 2 /O 2 ), ii) 320 mA/cm 2 at 0.8 V, 150 kPa, 80 ° C, 100% RH, H 2 /Air), and iii) > 1 W/cm 2 elec at rated power (0.67 V, 250 kPa, 94 °C, 65% RH, H 2 /Air) or < 0.11 g Pt /kW rated .

25 ENERGY STORAGE↗

Editors’ Choice—Examining Performance and Durability of Anion Exchange Membrane Fuel Cells with Novel Spirocyclic Anion Exchange Membranes

A series of spirocyclic copolymer membranes with varying ion exchange capacities (IECs) were investigated to probe the impact of polymer properties on in situ fuel cell performance and stability. In-situ electrochemical tests and post-mortem electron microscopy analysis of cross-sectioned membrane electrode assemblies (MEAs) have been combined with voltage loss breakdown analysis to evaluate the performance and degradation of different MEAs, and to probe the catalyst morphology and electrode structure at different stages of operation. Voltage loss breakdown results show that membrane degradation and kinetic losses played only a minor role in observed performance degradation and that performance losses were primarily related to increasing mass transport losses. From microscopy studies, carbon corrosion and Pt nanoparticle growth were identified at both the cathode and anode although more pronounced on the cathode resulting in significant structural changes. The membrane with the lowest IEC (1.3 mmolg −1 ) demonstrated the lowest peak power density ~ 1.16 W cm −2 , however, it showed the most stable performance (constant 0.6 A cm −2 hold) with ~ 5% degradation over 540 h. Isolation of performance losses and microscopic analysis of electrodes for anion exchange membrane fuel cells has not been reported previously, and these results help identify critical performance degradation concerns.

25 ENERGY STORAGE↗

Membrane Thickness Impact on Chemical Degradation Rates

Abstract A comprehensive investigation of PFSA membrane chemical degradation rates as a function of thickness (8-20 µm) is reported. The two-pronged study was conducted on bare membranes and as components of chemically-mitigated and mechanically-reinforced, state-of-the-art (SOA) membrane electrode assemblies (MEAs). The bare membranes were subjected to H2O2 vapor test and MEAs were degraded under OCV conditions, both at 90°C. Both test types employed fluoride release rates (FRR) to monitor chemical degradation rates. Vapor tests revealed that area-specific degradation rates were positively correlated with membrane thickness, but thickness normalized degradation rates were independent of thickness. Open-circuit voltage (OCV) investigations spanning the membrane thickness series of MEAs was probed via a 27-experiment 3(4-1) fractional factorial experimental design. Statistical analysis of the FRR values revealed that chemical degradation rates were dominated by the relative humidity value and that the area-specific degradation rates of MEAs were independent of membrane thickness. The OCV chemical durability insensitivity to membrane thickness is supported by on-load membrane chemical durability studies at the stack level. The results suggest that ,despite smaller ionomer inventory, SOA thin membranes and MEAs are not greatly disadvantaged relative to thicker membranes from a chemical durability perspective, provided oxidative stress levels are controlled throughout application lifetime.

Coms, Frank D. (ORCID:0000000249160350)↗