Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “medical image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Octave bandwidth photonic fishnet-achromatic-metalens

Planar structured interfaces, also known as metasurfaces, are continuously attracting interest owing to their ability to manipulate fundamental attributes of light, including angular momentum, phase, or polarization. However, chromatic aberration, limiting broadband operation, has remained a challenge for metasurfaces-based optical components and imagers. The limitation stems from the intrinsic dispersion of existing materials and design principles. Here we report and experimentally demonstrate polarization-independent fishnet-achromatic-metalenses with measured average efficiencies over 70% in the continuous band from the visible (640 nm) to the infrared (1200 nm). Results of the scalable platform are enabling for applications requiring broad bandwidth and high efficiency including energy harvesting, virtual reality and information processing devices, or medical imaging.

36 MATERIALS SCIENCE↗

Fiber-Coupled Acousto-Optical-Filter Spectrometer

Fiber-coupled acousto-optical-filter spectrometer steps rapidly through commanded sequence of wavelengths. Sample cell located remotely from monochromator and associated electronic circuitry, connected to them with optical fibers. Optical-fiber coupling makes possible to monitor samples in remote, hazardous, or confined locations. Advantages include compactness, speed, and no moving parts. Potential applications include control of chemical processes, medical diagnoses, spectral imaging, and sampling of atmospheres.

Levin, Kenneth H.↗

SU-F-J-57: Effectiveness of Daily CT-Based Three-Dimensional Image Guided and Adaptive Proton Therapy

Purpose: Daily CT-based three-dimensional image-guided and adaptive (CTIGRT-ART) proton therapy system was designed and developed. We also evaluated the effectiveness of the CTIGRT-ART. Methods: Retrospective analysis was performed in three lung cancer patients: Proton treatment planning was performed using CT image datasets acquired by Toshiba Aquilion ONE. Planning target volume and surrounding organs were contoured by a well-trained radiation oncologist. Dose distribution was optimized using 180-deg. and 270-deg. two fields in passive scattering proton therapy. Well commissioned Simplified Monte Carlo algorithm was used as dose calculation engine. Daily consecutive CT image datasets was acquired by an in-room CT (Toshiba Aquilion LB). In our in-house program, two image registrations for bone and tumor were performed to shift the isocenter using treatment CT image dataset. Subsequently, dose recalculation was performed after the shift of the isocenter. When the dose distribution after the tumor registration exhibits change of dosimetric parameter of CTV D90% compared to the initial plan, an additional process of was performed that the range shifter thickness was optimized. Dose distribution with CTV D90% for the bone registration, the tumor registration only and adaptive plan with the tumor registration was compared to the initial plan. Results: In the bone registration, tumor dose coverage was decreased by 16% on average (Maximum: 56%). The tumor registration shows better coverage than the bone registration, however the coverage was also decreased by 9% (Maximum: 22%) The adaptive plan shows similar dose coverage of the tumor (Average: 2%, Maximum: 7%). Conclusion: There is a high possibility that only image registration for bone and tumor may reduce tumor coverage. Thus, our proposed methodology of image guidance and adaptive planning using the range adaptation after tumor registration would be effective for proton therapy. This research is partially supported by Japan Agency for Medical Research and Development (AMED).

60 APPLIED LIFE SCIENCES↗

Microarthroscopy System With Image Processing Technology Developed for Minimally Invasive Surgery

In a joint effort, NASA, Micro Medical Devices, and the Cleveland Clinic have developed a microarthroscopy system with digital image processing. This system consists of a disposable endoscope the size of a needle that is aimed at expanding the use of minimally invasive surgery on the knee, ankle, and other small joints. This device not only allows surgeons to make smaller incisions (by improving the clarity and brightness of images), but it gives them a better view of the injured area to make more accurate diagnoses. Because of its small size, the endoscope helps reduce physical trauma and speeds patient recovery. The faster recovery rate also makes the system cost effective for patients. The digital image processing software used with the device was originally developed by the NASA Glenn Research Center to conduct computer simulations of satellite positioning in space. It was later modified to reflect lessons learned in enhancing photographic images in support of the Center's microgravity program. Glenn's Photovoltaic Branch and Graphics and Visualization Lab (G-VIS) computer programmers and software developers enhanced and speed up graphic imaging for this application. Mary Vickerman at Glenn developed algorithms that enabled Micro Medical Devices to eliminate interference and improve the images.

Steele, Gynelle C.↗

Terahertz time-domain spectroscopy imaging of pancreatic ductal adenocarcinoma tissues

Pancreatic ductal adenocarcinoma (PDAC) ranks among the malignancies with the highest fatality and morbidity rates. This is predominantly attributable to an absence of understanding the intricate and diverse microenvironment of the tumor. We use terahertz time-domain spectroscopy (THz-TDS) imaging in transmission geometry to probe ex-vivo the heterogenous microenvironment of the genetically modified murine PDAC tissue that closely resembles the PDAC heterogeneity in human malignancy. We introduced a maximum a-posteriori probability estimation algorithm to objectively the tumor’s heterogenous microenvironment using the average values of refractive index and absorption coefficient within the useable terahertz bandwidth as imaging markers. Furthermore, direct comparison of stained histopathologic images and the refractive index and the absorption coefficient high-resolution, two dimensional maps of the same PDAC samples confirms the high potential of the THz-TDS method for tumor tissue characterization.

absorption↗

SU-E-J-226: Propagation of Pancreas Target Contours On Respiratory Correlated CT Images Using Deformable Image Registration

Purpose: Respiratory Correlated CT (RCCT) scans to assess intra-fraction motion among pancreatic cancer patients undergoing radiotherapy allow for dose sparing of normal tissues, in particular for the duodenum. Contour propagation of the gross tumor volume (GTV) from one reference respiratory phase to 9 other phases is time consuming. Deformable image registration (DIR) has been successfully used for high contrast disease sites but lower contrast for pancreatic tumors may compromise accuracy. This study evaluates the accuracy of Fast Free Form (FFF) registration-based contour propagation of the GTV on RCCT scans of pancreas cancer patients. Methods: Twenty-four pancreatic cancer patients were retrospectively studied; 20 had tumors in the pancreatic head/neck, 4 in the body/tail. Patients were simulated with RCCT and images were sorted into 10 respiratory phases. A radiation oncologist manually delineated the GTV for 5 phases (0%, 30%, 50%, 70% and 90%). The FFF algorithm was used to map deformations between the EE (50%) phase and each of the other 4 phases. The resultant deformation fields served to propagate GTV contours from EE to the other phases. The Dice Similarity Coefficient (DSC), which measures agreement between the DIR-propagated and manually-delineated GTVs, was used to quantitatively examine DIR accuracy. Results: Average DSC over all scans and patients is 0.82 and standard deviation is 0.09 (DSC range 0.97–0.57). For GTV volumes above and below the median volume of 20.2 cc, a Wilcoxon rank-sum test shows significantly different DSC (p=0.0000002). For the GTVs above the median volume, average +/− SD is 0.85 +/− 0.07; and for the GTVs below, the average +/− SD is 0.75 +/−0.08. Conclusion: For pancreatic tumors, the FFF DIR algorithm accurately propagated the GTV between the images in different phases of RCCT, with improved performance for larger tumors.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 71: A 4D Multimodal Lung Phantom for Regmentation Evaluation

Segmentation and registration of medical imaging data are two processes that can be integrated (a process termed regmentation) to iteratively reinforce each other, potentially improving efficiency and overall accuracy. A significant challenge is presented when attempting to validate the joint process particularly with regards to minimizing geometric uncertainties associated with the ground truth while maintaining anatomical realism. This work demonstrates a 4D MRI, PET, and CT compatible tissue phantom with a known ground truth for evaluating registration and segmentation accuracy. The phantom consists of a preserved swine lung connected to an air pump via a PVC tube for inflation. Mock tumors were constructed from sea sponges contained within two vacuum-sealed compartments with catheters running into each one for injection of radiotracer solution. The phantom was scanned using a GE Discovery-ST PET/CT scanner and a 0.23T Phillips MRI, and resulted in anatomically realistic images. A bifurcation tracking algorithm was implemented to provide a ground truth for evaluating registration accuracy. This algorithm was validated using known deformations of up to 7.8 cm using a separate CT scan of a human thorax. Using the known deformation vectors to compare against, 76 bifurcation points were selected. The tracking accuracy was found to have maximum mean errors of −0.94, 0.79 and −0.57 voxels in the left-right, anterior-posterior and inferior-superior directions, respectively. A pneumatic control system is under development to match the respiratory profile of the lungs to a breathing trace from an individual patient.

60 APPLIED LIFE SCIENCES↗

SU-E-J-123: Assessing Segmentation Accuracy of Internal Volumes and Sub-Volumes in 4D PET/CT of Lung Tumors Using a Novel 3D Printed Phantom

Purpose: To assess the accuracy of internal target volume (ITV) segmentation of lung tumors for treatment planning of simultaneous integrated boost (SIB) radiotherapy as seen in 4D PET/CT images, using a novel 3D-printed phantom. Methods: The insert mimics high PET tracer uptake in the core and 50% uptake in the periphery, by using a porous design at the periphery. A lung phantom with the insert was placed on a programmable moving platform. Seven breathing waveforms of ideal and patient-specific respiratory motion patterns were fed to the platform, and 4D PET/CT scans were acquired of each of them. CT images were binned into 10 phases, and PET images were binned into 5 phases following the clinical protocol. Two scenarios were investigated for segmentation: a gate 30–70 window, and no gating. The radiation oncologist contoured the outer ITV of the porous insert with on CT images, while the internal void volume with 100% uptake was contoured on PET images for being indistinguishable from the outer volume in CT images. Segmented ITVs were compared to the expected volumes based on known target size and motion. Results: 3 ideal breathing patterns, 2 regular-breathing patient waveforms, and 2 irregular-breathing patient waveforms were used for this study. 18F-FDG was used as the PET tracer. The segmented ITVs from CT closely matched the expected motion for both no gating and gate 30–70 window, with disagreement of contoured ITV with respect to the expected volume not exceeding 13%. PET contours were seen to overestimate volumes in all the cases, up to more than 40%. Conclusion: 4DPET images of a novel 3D printed phantom designed to mimic different uptake values were obtained. 4DPET contours overestimated ITV volumes in all cases, while 4DCT contours matched expected ITV volume values. Investigation of the cause and effects of the discrepancies is undergoing.

60 APPLIED LIFE SCIENCES↗

SU-E-J-260: Quantitative Image Feature Analysis of Multiphase Liver CT for Hepatocellular Carcinoma (HCC) in Radiation Therapy

Purpose: To identify the effective quantitative image features (radiomics features) for prediction of response, survival, recurrence and metastasis of hepatocellular carcinoma (HCC) in radiotherapy. Methods: Multiphase contrast enhanced liver CT images were acquired in 16 patients with HCC on pre and post radiation therapy (RT). In this study, arterial phase CT images were selected to analyze the effectiveness of image features for the prediction of treatment outcome of HCC to RT. Response evaluated by RECIST criteria, survival, local recurrence (LR), distant metastasis (DM) and liver metastasis (LM) were examined. A radiation oncologist manually delineated the tumor and normal liver on pre and post CT scans, respectively. Quantitative image features were extracted to characterize the intensity distribution (n=8), spatial patterns (texture, n=36), and shape (n=16) of the tumor and liver, respectively. Moreover, differences between pre and post image features were calculated (n=120). A total of 360 features were extracted and then analyzed by unpaired student’s t-test to rank the effectiveness of features for the prediction of response. Results: The five most effective features were selected for prediction of each outcome. Significant predictors for tumor response and survival are changes in tumor shape (Second Major Axes Length, p= 0.002; Eccentricity, p=0.0002), for LR, liver texture (Standard Deviation (SD) of High Grey Level Run Emphasis and SD of Entropy, both p=0.005) on pre and post CT images, for DM, tumor texture (SD of Entropy, p=0.01) on pre CT image and for LM, liver (Mean of Cluster Shade, p=0.004) and tumor texture (SD of Entropy, p=0.006) on pre CT image. Intensity distribution features were not significant (p>0.09). Conclusion: Quantitative CT image features were found to be potential predictors of the five endpoints of HCC in RT. This work was supported in part by the National Cancer Institute Grant R01CA172638.

60 APPLIED LIFE SCIENCES↗

SU-E-J-267: Change in Mean CT Intensity of Lung Tumors During Radiation Treatment

Purpose: To evaluate CT intensity change of lung tumors during radiation therapy. Methods: Repeated 4D CT images were acquired on a CT simulator during the course of therapy for 27 lung cancer patients on IRB approved protocols. All subjects received definitive radiation treatment ± chemotherapy. CT scans were completed prior to treatment, and 2–7 times during the treatment course. Primary tumor was delineated by an experienced Radiation Oncologist. Contours were thresholded between −100 HU and 200 HU to remove airways and bone. Correlations between the change in the mean tumor intensity and initial tumor intensity, SUVmax, and tumor volume change rate were investigated. Reproducibility was assessed by evaluating the variation in mean intensity over all phases in 4DCT, for a subgroup of 19 subjects. Results: Reproducibility of tumor intensity between phases as characterized by the root mean square of standard deviation across 19 subjects was 1.8 HU. Subjects had a mean initial tumor intensity of 16.5 ± 11.6 HU and an overall reduction in HU by 10.3 ± 8.5 HU. Evaluation of the changes in tumor intensity during treatment showed a decrease of 0.3 ± 0.3 HU/day for all subjects, except three. No significant correlation was found between change in HU/day and initial HU intensity (p=0.53), initial PET SUVmax (p=0.69), or initial tumor volume (p=0.70). The rate of tumor volume change was weakly correlated (R{sup 2}=0.05) with HU change (p=0.01). Conclusion: Most lung cancer subjects showed a marked trend of decreasing mean tumor CT intensity throughout radiotherapy, including early in the treatment course. Change in HU/day is not correlated with other potential early predictors for response, such as SUV and tumor volume change. This Result supports future studies to evaluate change in tumor intensity on CT as an early predictor of response.

60 APPLIED LIFE SCIENCES↗

Interactive contour delineation of organs at risk in radiotherapy: Clinical evaluation on NSCLC patients

Purpose: Accurate delineation of organs at risk (OARs) on computed tomography (CT) image is required for radiation treatment planning (RTP). Manual delineation of OARs being time consuming and prone to high interobserver variability, many (semi-) automatic methods have been proposed. However, most of them are specific to a particular OAR. Here, an interactive computer-assisted system able to segment various OARs required for thoracic radiation therapy is introduced. Methods: Segmentation information (foreground and background seeds) is interactively added by the user in any of the three main orthogonal views of the CT volume and is subsequently propagated within the whole volume. The proposed method is based on the combination of watershed transformation and graph-cuts algorithm, which is used as a powerful optimization technique to minimize the energy function. The OARs considered for thoracic radiation therapy are the lungs, spinal cord, trachea, proximal bronchus tree, heart, and esophagus. The method was evaluated on multivendor CT datasets of 30 patients. Two radiation oncologists participated in the study and manual delineations from the original RTP were used as ground truth for evaluation. Results: Delineation of the OARs obtained with the minimally interactive approach was approved to be usable for RTP in nearly 90% of the cases, excluding the esophagus, which segmentation was mostly rejected, thus leading to a gain of time ranging from 50% to 80% in RTP. Considering exclusively accepted cases, overall OARs, a Dice similarity coefficient higher than 0.7 and a Hausdorff distance below 10 mm with respect to the ground truth were achieved. In addition, the interobserver analysis did not highlight any statistically significant difference, at the exception of the segmentation of the heart, in terms of Hausdorff distance and volume difference. Conclusions: An interactive, accurate, fast, and easy-to-use computer-assisted system able to segment various OARs required for thoracic radiation therapy has been presented and clinically evaluated. The introduction of the proposed system in clinical routine may offer valuable new option to radiation oncologists in performing RTP.

60 APPLIED LIFE SCIENCES↗

Sharp-Focus Composite Microscope Imaging by Computer

Enhanced depth of focus aids medical analysis. Computer image-processing system synthesizes sharply-focused composite picture from series of photomicrographs of same object taken at different depths. Computer rejects blured parts of each photomicrograph. Remaining in focus portions form focused composite. System used to study alveolar lung tissue and has applications in medicine and physical sciences.

Wall, R. J.↗

Utilization of Machine Learning Techniques for Managing the Tracking and Data Relay Satellite Constellation

National Aeronautics and Space Administration’s (NASA) Goddard Space Flight Center (GSFC) operates a constellation of ten geosynchronous Tracking and Data Relay Satellites (TDRS). The TDRS constellation consists of multiple geosynchronous communication relay satellites located around the equator so they can provide continual coverage of any mission in low earth orbit. The TDRS are located primarily in three oceanic regions around the earth. NASA’s White Sands Complex provides the ground communication support for TDRS located over the Atlantic and Pacific Oceans. Another TDRS ground station in Guam supports the TDRS over the Indian Ocean. With these satellites the TDRS network can provide continuous coverage of satellites in low-earth orbit. The NASA Space Network (SN) project office at GSFC manages the constellation of spacecraft. Major customers of the TDRS constellation include, but are not limited to, the International Space Station and the Hubble Space Telescope. The TDRS constellation has three generations of satellites and has been active for over 30 years providing reliable communication links between customer satellites and corresponding ground stations. However, one of the major concerns for TDRS, and in any space mission, is to ensure the health and safety of the spacecraft. Generally, engineers use telemetry data to monitor and analyze the performance and state of health of the spacecraft. Telemetry data contains hundreds of parameters that monitor each important component in the spacecraft, which can be utilized to recognize and characterize the behavior of the spacecraft. Each parameter contains considerable information to represent time-dependent properties of each spacecraft subsystem and component. During the entire life of a TDRS spacecraft, thousands of gigabytes of telemetry data are transmitted in real-time from the spacecraft to the ground station at the White Sands Complex in Las Cruces, New Mexico, and recorded as historical data sets for engineers to process and analyze the events that occurred on-orbit. These parameters contain the function of multiple spacecraft subsystems, such as the attitude control system (ACS), Thermal, Electrical Power Subsystem (EPS), etc. . The first and second generations have exceeded their required lifetime and NASA is keen to manage these spacecrafts carefully in order to maximize the remaining life using the spacecraft telemetry. The challenge is to know when the risk of losing a spacecraft in geosynchronous orbit exceeds the benefit of continued operations for customer support. In the TDRS fleet, the EPS is the most critical subsystem related to spacecraft operations. Failure of the EPS would strand a spacecraft in geosynchronous orbit. Since EPS provides power to the spacecraft, component failures ultimately lead to the inability to support the spacecraft loads and the communications payload. For instance, TDRS-8 has several anomalies in EPS including the Bus Voltage Limiter (BVL) shunt current, solar array loss of circuits, and failed battery cells. Any of these anomalies can cause critical issues to the spacecraft. Therefore, developing a system to analyze and perform early detection of a potential anomaly is an important issue in telemetry data analysis. In recent years, Telemetry Mining (TM) has been proposed to process telemetry data by using Data Mining (DM) techniques such as classification, clustering, regression and anomaly detection. Anomaly detection, also known as outlier detection, has been widely used in many data mining areas such as remote sensing, medical data processing and digital image processing. The goal of anomaly detection is to detect abnormal data, which contains a relatively low probability of occurrence among the entire data set. Early detection of anomalies is one of the most significant issues in managing the spacecraft configuration. If anomalies can be detected early enough, then the redundant resources can be used to extend the life of the operational spacecraft. We present an unsupervised anomaly detection method to process the EPS data extracted from TDRS-8. This is different from traditional analytical methods, which use telemetry data to illustrate behavior and physical meaning of each spacecraft component. TM connects multiple parameters as a vector and then conducts data analysis on this high dimension telemetry vector. This method is looking at the properties of a high dimensional vector that is able to consider the relationship between different parameters in the anomaly detection problem. This kind of method performs much better than the traditional limit checking method. In addition, we propose a new approach of real-time anomaly detection to process telemetry data in real-time, which can then be applied to spacecraft monitoring with high reliability, low cost and high accuracy.

Machine Learning (ML)↗

Medical Imaging System

The MD Image System, a true-color image processing system that serves as a diagnostic aid and tool for storage and distribution of images, was developed by Medical Image Management Systems, Huntsville, AL, as a "spinoff from a spinoff." The original spinoff, Geostar 8800, developed by Crystal Image Technologies, Huntsville, incorporates advanced UNIX versions of ELAS (developed by NASA's Earth Resources Laboratory for analysis of Landsat images) for general purpose image processing. The MD Image System is an application of this technology to a medical system that aids in the diagnosis of cancer, and can accept, store and analyze images from other sources such as Magnetic Resonance Imaging.

Source record↗

Medical Imaging

This video shows how satellite data processing techniques (multispectral scanning) can improve disease detection and treatment.

Source record↗

Potential medical applications of TAE

In cooperation with scientists in the University of Washington Medical School, a microcomputer-based image processing system for quantitative microscopy, called DMD1 (Digital Microdensitometer 1) was constructed. In order to make DMD1 transportable to different hosts and image processors, we have been investigating the possibility of rewriting the lower level portions of DMD1 software using Transportable Applications Executive (TAE) libraries and subsystems. If successful, we hope to produce a newer version of DMD1, called DMD2, running on an IBM PC/AT under the SCO XENIX System 5 operating system, using any of seven target image processors available in our laboratory. Following this implementation, copies of the system will be transferred to other laboratories with biomedical imaging applications. By integrating those applications into DMD2, we hope to eventually expand our system into a low-cost general purpose biomedical imaging workstation. This workstation will be useful not only as a self-contained instrument for clinical or research applications, but also as part of a large scale Digital Imaging Network and Picture Archiving and Communication System, (DIN/PACS). Widespread application of these TAE-based image processing and analysis systems should facilitate software exchange and scientific cooperation not only within the medical community, but between the medical and remote sensing communities as well.

Fahy, J. Ben↗

SU-E-P-59: A Graphical Interface for XCAT Phantom Configuration, Generation and Processing

Purpose: To design a comprehensive open-source, publicly available, graphical user interface (GUI) to facilitate the configuration, generation, processing and use of the 4D Extended Cardiac-Torso (XCAT) phantom. Methods: The XCAT phantom includes over 9000 anatomical objects as well as respiratory, cardiac and tumor motion. It is widely used for research studies in medical imaging and radiotherapy. The phantom generation process involves the configuration of a text script to parameterize the geometry, motion, and composition of the whole body and objects within it, and to generate simulated PET or CT images. To avoid the need for manual editing or script writing, our MATLAB-based GUI uses slider controls, drop-down lists, buttons and graphical text input to parameterize and process the phantom. Results: Our GUI can be used to: a) generate parameter files; b) generate the voxelized phantom; c) combine the phantom with a lesion; d) display the phantom; e) produce average and maximum intensity images from the phantom output files; f) incorporate irregular patient breathing patterns; and f) generate DICOM files containing phantom images. The GUI provides local help information using tool-tip strings on the currently selected phantom, minimizing the need for external documentation. The DICOM generation feature is intended to simplify the process of importing the phantom images into radiotherapy treatment planning systems or other clinical software. Conclusion: The GUI simplifies and automates the use of the XCAT phantom for imaging-based research projects in medical imaging or radiotherapy. This has the potential to accelerate research conducted with the XCAT phantom, or to ease the learning curve for new users. This tool does not include the XCAT phantom software itself. We would like to acknowledge funding from MRA, Varian Medical Systems Inc.

60 APPLIED LIFE SCIENCES↗

MO-DE-201-03: This course presents a review of radiologic anatomy and physiology as it applies to projection radiography, fluoroscopy, CT, MRI, U/S, and nuclear medicine

Fundamental knowledge of radiologic anatomy and physiology is critical for medical physicists. Many physicists are exposed to this topic only in graduate school, and knowledge is seldom formally evaluated or assessed after Part I of the ABR exam. Successful interactions with clinicians, including surgeons, radiologists, and oncologists requires that the medical physicist possess this knowledge. This course presents a review of radiologic anatomy and physiology as it applies to projection radiography, fluoroscopy, CT, MRI, U/S, and nuclear medicine. We will review structural anatomy, manipulation of tissue contrast, the marriage between anatomy and physiology, and explore how medical imaging exploits normal and pathological processes in the body to generate contrast. Learning Objectives: Review radiologic anatomy. Examine techniques to manipulate tissue contrast in radiology. Integrate anatomy and physiology in molecular imaging.

60 APPLIED LIFE SCIENCES↗