Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Analyzing count data with measurement error

In this article, we analyze observed count data such as the number of defects in a steel product where the observed counts are the true counts measured with errors. We account for the measurement error by using a measurement error model based on a latent lognormal (LLN) distribution. We consider making inference about a single population (e.g., from samples of a production lot) and a regression model (e.g., from runs of a designed experiment), where the measurement system properties are known, that is, the parameters of the LLN distribution are known. Then, we consider simultaneous inference for the single population and regression model as well as the measurement system. We demonstrate the proposed methodology with both simulated and real observed counts.

42 ENGINEERING↗

SU-E-J-88: The Study of Setup Error Measured by CBCT in Postoperative Radiotherapy for Cervical Carcinoma

Purpose: To compare two registration methods in the CBCT guided radiotherapy for cervical carcinoma, analyze the setup errors and registration methods, determine the margin required for clinical target volume(CTV) extending to planning target volume(PTV). Methods: Twenty patients with cervical carcinoma were enrolled. All patients were underwent CT simulation in the supine position. Transfering the CT images to the treatment planning system and defining the CTV, PTV and the organs at risk (OAR), then transmit them to the XVI workshop. CBCT scans were performed before radiotherapy and registered to planning CT images according to bone and gray value registration methods. Compared two methods and obtain left-right(X), superior-inferior(Y), anterior-posterior (Z) setup errors, the margin required for CTV to PTV were calculated. Results: Setup errors were unavoidable in postoperative cervical carcinoma irradiation. The setup errors measured by method of bone (systemic ± random) on X(1eft.right),Y(superior.inferior),Z(anterior.posterior) directions were(0.24±3.62),(0.77±5.05) and (0.13±3.89)mm, respectively, the setup errors measured by method of grey (systemic ± random) on X(1eft-right), Y(superior-inferior), Z(anterior-posterior) directions were(0.31±3.93), (0.85±5.16) and (0.21±4.12)mm, respectively.The spatial distributions of setup error was maximum in Y direction. The margins were 4 mm in X axis, 6 mm in Y axis, 4 mm in Z axis respectively.These two registration methods were similar and highly recommended. Conclusion: Both bone and grey registration methods could offer an accurate setup error. The influence of setup errors of a PTV margin would be suggested by 4mm, 4mm and 6mm on X, Y and Z directions for postoperative radiotherapy for cervical carcinoma.

60 APPLIED LIFE SCIENCES↗

Comparing range data across the slow-time dimension to correct motion measurement errors beyond the range resolution of a synthetic aperture radar

Motion measurement errors that extend beyond the range resolution of a synthetic aperture radar (SAR) can be corrected by effectively decreasing the range resolution of the SAR in order to permit measurement of the error. Range profiles can be compared across the slow-time dimension of the input data in order to estimate the error. Once the error has been determined, appropriate frequency and phase correction can be applied to the uncompressed input data, after which range and azimuth compression can be performed to produce a desired SAR image.

Doerry, Armin W↗

Mitigating the Impacts of Measurement Error in the Quesst Mission Community Noise Study

Beginning in 2025, the NASA Quesst mission will conduct a series of community response tests involving flyovers of the X-59 aircraft at select localities across the United States. Several waves of a longitudinal survey will be administered over approximately one month of testing in order to capture perceptual responses to low-amplitude sonic booms, or “sonic thumps”. Simultaneously, noise exposure levels will be estimated by fusing model-based predictions with measurements taken from a sparse network of monitors in the region. As one of the aims of the study is to produce a dose-response curve, a regression model relating perceptual response to noise exposure levels, it is important to acknowledge the potential attenuation bias that results from measurement error in the estimated noise exposure levels. In this presentation we review and compare several methods for dealing with measurement error in generalized linear mixed models. The methods are demonstrated on simulated data and real data collected during past NASA risk reduction studies.

measurement error↗

Machine Straightness Error Measurement Based on Optical Fiber Fabry–Pérot Interferometer Monitoring Technique

Abstract In this research, we propose an Error Separation Technique (EST) based on optical fiber sensors for on-machine straightness error measurement. Two fiber optic Fabry–Pérot interferometers have been developed serving as two displacement sensors. The displacement distance is computed according to the reflected spectrum from interferometers, which can achieve a sub-micrometer resolution. The two-point method has been employed to separate the straightness error of the slides and the profile error of a fine-polished standard block. The spacing distance between two interferometers is determined by the diameter of optical fibers so that the EST's resolution has the potential to reach the sub-millimeter scale. In the experiment, the straightness error has been measured on a commercially available computer numerical control machine tool, and the measurement has been conducted on its x-axis. The spacing distance between two optical fiber sensors is 1.5 mm which equals the EST's resolution along the machine tool's x-axis. The separated profile error of the measured standard block is around 30 µm which has been verified by a high precision Coordinate Measurement Machine (CMM). The magnitude of the separated straightness error is around 40 µm. This technique is flexible and simple to be conducted, which can contribute to the micro-machine tool calibration and other straightness error applications.

Engineering↗

Self-calibration strategies for reducing systematic slope measurement errors of autocollimators in deflectometric profilometry

Deflectometric profilometers are used to precisely measure the form of beam shaping optics of synchrotrons and X-ray free-electron lasers. They often utilize autocollimators which measure slope by evaluating the displacement of a reticle image on a detector. Based on our privileged access to the raw image data of an autocollimator, novel strategies to reduce the systematic measurement errors by using a set of overlapping images of the reticle obtained at different positions on the detector are discussed. It is demonstrated that imaging properties such as, for example, geometrical distortions and vignetting, can be extracted from this redundant set of images without recourse to external calibration facilities. This approach is based on the fact that the properties of the reticle itself do not change – all changes in the reticle image are due to the imaging process. Firstly, by combining interpolation and correlation, it is possible to determine the shift of a reticle image relative to a reference image with minimal error propagation. Secondly, the intensity of the reticle image is analysed as a function of its position on the CCD and a vignetting correction is calculated. Thirdly, the size of the reticle image is analysed as a function of its position and an imaging distortion correction is derived. It is demonstrated that, for different measurement ranges and aperture diameters of the autocollimator, reductions in the systematic errors of up to a factor of four to five can be achieved without recourse to external measurements.

47 OTHER INSTRUMENTATION↗

Spectrally Dependent Radiometric Measurement Errors Due to Ccd Serial Pixel-to-Pixel Readout Interference in the Ocean Color Instrument of the NASA PACE Mission

The Ocean Color Instrument on NASA’s PACE mission is a 322 887 nm hyperspectral imager with 1 km x 1 km nadir spatial resolution and 5 nm spectral resolution utilizing charge-coupled devices (CCDs) operating in Time Delay Integration (TDI) mode where each TDI column represents a different wavelength in 0.625 nm increments. After TDI, the charge is moved into serial output pixels and read out. The spatial resolution requires an 8.5 MHz readout rate. This only allows 59 ns for the CCD reset and video to be asserted and settled before sampling. The response exhibits serial pixel-to-pixel readout interference due to the lack of full settling. Each serial pixel value has a dependence on the value of the preceding pixel value. This leads to a spectrally dependent radiometric measurement error of up to 0.3 %. We explain the operation of the detection system, the behavior of the interference, and show the resulting measurement error based on data from both ground testing and on-orbit characterization.

Remote Sensing↗

Spectrally Dependent Radiometric Measurement Errors Due to CCD Serial Pixel-to-Pixel Readout Interference in the Ocean Color Instrument of the NASA PACE Mission

The Ocean Color Instrument on NASA’s PACE mission is a 322 887 nm hyperspectral imager with 1 km x 1 km nadir spatial resolution and 5 nm spectral resolution utilizing charge-coupled devices (CCDs) operating in Time Delay Integration (TDI) mode where each TDI column represents a different wavelength in 0.625 nm increments. After TDI, the charge is moved into serial output pixels and read out. The spatial resolution requires an 8.5 MHz readout rate. This only allows 59 ns for the CCD reset and video to be asserted and settled before sampling. The response exhibits serial pixel-to-pixel readout interference due to the lack of full settling. Each serial pixel value has a dependence on the value of the preceding pixel value. This leads to a spectrally dependent radiometric measurement error of up to 0.3 %. We explain the operation of the detection system, the behavior of the interference, and show the resulting measurement error based on data from both ground testing and on-orbit characterization.

Remote Sensing↗

The Effect of Measurement Error on Surveillance Metrics

The purpose of this manuscript is to describe different simulation studies that CCS-6 has performed for the purpose of understanding the effects of measurement error on the surveillance metrics. We assume that the measured items come from a larger population of items. We denote the random variable associate with an item's value of an attribute of interest as X and that $X \text{~} N(\mu, \sigma^2$). This distribution represents the variability in the population of interest and we wish to make inference on the parameters $\mu$ and $\sigma$ or on some function of these parameters. When an item X is selected from the larger population, a measurement is made on some attribute of it. This measurement is made with error and the true value of X is not observed. The rest of this section presents simulation results for different measurement cases encountered.

42 ENGINEERING↗

Sensitivity of mesoscale-model forecast skill to some initial-data characteristics, data density, data position, analysis procedure and measurement error

The effects of horizontal and vertical data resolution, data density, data location, different objective analysis algorithms, and measurement error on mesoscale-forecast accuracy are studied with observing-system simulation experiments. Domain-averaged errors are shown to generally decrease with time. It is found that the vertical distribution of error growth depends on the initial vertical distribution of the error itself. Larger gravity-inertia wave noise is produced in forecasts with coarser vertical data resolution. The use of a low vertical resolution observing system with three data levels leads to more forecast errors than moderate and high vertical resolution observing systems with 8 and 14 data levels. Also, with poor vertical resolution in soundings, the initial and forecast errors are not affected by the horizontal data resolution.

Warner, Thomas T.↗

System Measures Errors Between Time-Code Signals

System measures timing errors between signals produced by three asynchronous time-code generators. Errors between 1-second clock pulses resolved to 2 microseconds. Basic principle of computation of timing errors as follows: central processing unit in microcontroller constantly monitors time data received from time-code generators for changes in 1-second time-code intervals. In response to any such change, microprocessor buffers count of 16-bit internal timer.

Cree, David↗

Theoretical analysis on the measurement errors of local 2D DIC: Part I temporal and spatial uncertainty quantification of displacement measurements

This study presents a theoretical uncertainty quantification of displacement measurements by subset-based 2D-digital image correlation. A generalized solution to estimate the random error of displacement measurement is presented. The obtained solution suggests that the random error of displacement measurements is determined by the image noise, the summation of the intensity gradient in a subset, the subpixel part of displacement, and the interpolation scheme. The proposed method is validated with virtual digital image correlation tests.

2D-DIC↗

A study of GPS measurement errors due to noise and multipath interference for CGADS

This report describes a study performed by the Colorado Center for Astrodynamics Research (CCAR) on GPS measurement errors in the Codeless GPS Attitude Determination System (CGADS) due to noise and multipath interference. Preliminary simulation models fo the CGADS receiver and orbital multipath are described. The standard FFT algorithms for processing the codeless data is described and two alternative algorithms - an auto-regressive/least squares (AR-LS) method, and a combined adaptive notch filter/least squares (ANF-ALS) method, are also presented. Effects of system noise, quantization, baseband frequency selection, and Doppler rates on the accuracy of phase estimates with each of the processing methods are shown. Typical electrical phase errors for the AR-LS method are 0.2 degrees, compared to 0.3 and 0.5 degrees for the FFT and ANF-ALS algorithms, respectively. Doppler rate was found to have the largest effect on the performance.

Axelrad, Penina↗

Measurement Error of Interferometers with Diffraction Reference Wave

An experimental setup and results on aberration of sources of a reference spherical wave (SRSW) based on a single-mode optical fiber with a subwavelength output aperture obtained with the aid of an optical part of recording system (OPRS) are presented. SRSW and OPRS are developed for referenceless interferometer with diffraction reference wave. Methods for minimization of the measurement error are proposed. The SRSW and OPRS provide subnanometer measurement accuracy for optics. An increase in the measurement accuracy of the interferometer to a picometer level is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗