Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “magnetic SANS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Direct evidence of the effect of a moderate external magnetic field on stimulated Raman scattering in the kinetic regime

We present results from an experiment carried out at the OMEGA-EP laser facility that investigated the effect of a perpendicular magnetic field on stimulated Raman scattering (SRS) and report the first direct measurement of magnetic mitigation of SRS. A 13-T magnetic field generated by pulsed-power coils was imposed on a gas jet plasma, and a novel three-picket interaction beam was used to explore SRS reflectivity for several plasma conditions within single shots. The time-resolved backscattered light shows that SRS was mitigated by the external 13-T magnetic field in the kinetic regime (kλ D ∼ 0.3, where k is the electron plasma wave's wavenumber and λ D is electron Debye length) and at a density of n e /n cr ∼ 0.10. On the other hand, we also measured an enhancement of SRS reflectivity at lower density (n e /n cr < 0.08). We discuss experimental results in the context of magnetohydrodynamic and particle-in-cell simulations that scan SRS dynamics for a variety of plasma conditions. While the experimental evidence of SRS mitigation validates prior work on the kinetic simulation of SRS in an external magnetic field, we also find that other mechanisms such as SRS rescatter can lead to an enhancement of measured SRS reflectivity in simulations of parameters relevant to our experiment.

Gas jet↗

Fiber optic and laser sensors V; Proceedings of the Meeting, San Diego, CA, Aug. 17-19, 1987

The papers contained in this volume focus on recent developments in fiber optic and laser sensors. Topics discussed include electric and magnetic field sensors, fiber optic pressure sensors, fiber optic gyros, fiber optic sensors for aerospace applications, fiber sensor multiplexing, temperature sensors, and specialized fiber optic sensors. Papers are presented on remote fiber optic sensors for angular orientation; fiber optic rotation sensor for space missions; adaptation of an electro-optic monitoring system to aerospace structures; optical fiber sensor for dust concentration measurements; and communication-sensing system using a single optical fiber.

De Paula, Ramon P.↗

Nanosized Organo-Silica Particles with “Built-In” Surface-Initiated Atom Transfer Radical Polymerization Capability as a Platform for Brush Particle Synthesis

A facile synthetic method was developed to prepare sub-5 nm organo-silica (oSiO 2 ) nanoparticles through the self-condensation of ATRP-initiator-containing silica precursors. The obtained oSiO 2 nanoparticles were characterized by a combination of nuclear magnetic resonance (NMR), thermogravimetric analysis (TGA), transmission electron microscopy (TEM), dynamic light scattering (DLS) and small-angle neutron scattering (SANS). The accessibility of the surface -Br initiating sites was evaluated by the polymerization of poly(methyl methacrylate) (PMMA) ligands from the surface of the oSiO 2 nanoparticles using surface-initiated atom transfer radical polymerization (SI-ATRP). Here, the ultra-small size, tunable composition and ease of surface modification may render these organosilica nanoparticle systems with built-in SI-ATRP capability an interesting alternative to conventional silica nanoparticles for functional material design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Defect Characterization of Monocrystalline Silicon Solar Cells with Polysilicon Passivated Contact Using Electrically-Detected Magnetic Resonance (EDMR) Spectroscopy

As the c-Si based solar cell efficiencies are approaching over 26%, it is becoming critical to characterize the low concentrations of the defects – as low as 10^10-10^11 cm-3 (for e.g., iron contamination in high-lifetime Ga-doped wafers3 and n-type wafers), and further reduce them. Also, atomistic level understanding of the mechanisms of the low concentration process-induced-defects and reliability limiting defects (such as light and elevated temperature induced degradation, surface passivation degradation) is needed to design the mitigation strategies. The conventional characterization techniques are limited due to their detection limitations. Some of the techniques based on lifetime spectroscopies can still be used for low concentration characterization however, they are based on estimations and theoretical models and hence, indirect and cannot fully reveal information about the microscopic mechanism of the defects. Thus, we present the application of an ultrasensitive magnetic resonance-based technique for the direct spectroscopic detection of the defects in Si PV - electrically detected magnetic resonance (EDMR). In this work, we aim to focus on establishing a process flow for fabrication of minicells with (miniature replica of the larger-area cells) and setting up the routine for EDMR measurements on them with the EDMR instrumentation capability at NREL. For the EDMR measurements, sample size is limited by the dimensions of sample holder tube (width less than 3.2 mm, active area - 20 mm). Thus, we have designed c-Si based minicells with polysilicon (poly-Si) passivated contacts same as the larger-area cells that we fabricate in our group at NREL. We also modified our minicell process flow for fabricating the textured minicells for preserving the texture during processing and taking care of the laser-ablation edge damage which can significantly affect the performance of such small devices. We have achieved comparable performance on these newly fabricated minicells as that of our 4 cm2 devices with same structure (comparable VOC, JSC, FF). We also conducted EDMR measurements on the minicells and observed a distinct EDMR signal at g-value ~2.005 at temperatures 30K and above, as shown in Fig. 2. We associate this signal to the presence of silicon dangling bonds based on the g-value. We also observed an EDMR signal at g-value ~1.998 at temperature ~5K. The origin of this signal is still being investigated. Thus, we show the proof of concept of minicells and EDMR measurements with which we now aim to study some of the unknown defects in silicon solar cell devices.

EDMR↗

Nonlinear feedback model attitude control using CCD in magnetic suspension system

A model attitude control system for a CCD camera magnetic suspension system is studied in this paper. In a recent work, a position and attitude sensing method was proposed. From this result, model position and attitude of a magnetic suspension system can be detected by generating digital outputs. Based on this achievement, a control system design using nonlinear feedback techniques for magnetic suspended model attitude control is proposed.

Lin, CHIN-E.↗

Plasma shape and position control development for NSTX-U using the GSEvolve plasma simulator

NSTX-U discharges have been reproduced using the GSEvolve plasma simulator in order to improve their control and reduce oscillations during the plasma current (Ip) ramp-up phase, and with the ultimate goal of enabling reliable H-mode access with a double-null shape at high elongation, low internal inductance, and high plasma performance. The control objective is to eliminate undesired oscillations in the plasma shape and vertical position that start when the plasma diverts during the Ip ramp-up phase, and that happened recurrently during the first NSTX-U experimental campaign. Model-based control solutions have been developed, including alternative H-mode access recipes and a Multi-Input Multi-Output (MIMO) decoupling controller. These solutions have demonstrated their capability to reduce or eliminate the aforementioned oscillations in GSEvolve simulations, enabling reproducible H-mode access. The results of this work aim to inform NSTX-U experimental operations on potential control developments to maximize its scientific output, and highlight the powerful capabilities of high-fidelity control-simulation frameworks like GSEvolve.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-Volatile Memory Technology Symposium 2001: Proceedings

This publication contains the proceedings for the Non-Volatile Memory Technology Symposium 2001 that was held on November 7-8, 2001 in San Diego, CA. The proceedings contains a a wide range of papers that cover current and new memory technologies including Flash memories, Magnetic Random Access Memories (MRAM and GMRAM), Ferro-electric RAM (FeRAM), and Chalcogenide RAM (CRAM). The papers presented in the proceedings address the use of these technologies for space applications as well as radiation effects and packaging issues.

Aranki, Nazeeh↗

Mars Sample Return Using Commercial Capabilities: ERV Trajectory and Capture Requirements

Mars Sample Return was presented as the highest priority planetary science mission of the next decade [1]. Lemke et al. [2] present a Mars Sample Return mission concept in which the sample is returned directly from the surface of Mars to an Earth orbit. The sample is recovered in Earth Orbit instead of being transferred between spacecraft in Mars Orbit. This paper provides the details of this sample recovery in Earth orbit and presents as such a sub-element of the overall Mars sample return concept given in [2]. We start from the assumption that a Mars Ascent Vehicle (MAV), initially landed on Mars using a modified SpaceX Dragon capsule, has successfully delivered the sample, already contained within an Earth Return Vehicle (ERV), to a parking orbit around Mars. From the parking orbit, the ERV imparts sufficient Delta-V to inject itself into an earthbound trajectory and to be captured into an Earth orbit eventually. We take into account launch window and Delta-V considerations as well as the additional constraint of increased safety margins imposed by planetary protection regulations. We focus on how to overcome two distinct challenges of the sample return that are driven by the issues of planetary protection: (1) the design of an ERV trajectory meeting all the requirements including the need to avoid contamination of Earth's atmosphere; (2) the concept of operations for retrieving the Martian samples in Earth orbit in a safe way. We present an approach to retrieve the samples through a rendezvous between the ERV and a second SpaceX Dragon capsule. The ERV executes a trajectory that brings it from low Mars orbit (LMO) to a Moon-trailing Earth orbit at high inclination with respect to the Earth-Moon plane. After a first burn at Trans-Earth Injection (TEI), the trajectory uses a second burn at perigee during an Earth flyby maneuver to capture the ERV in Earth orbit. The ERV then uses a non-propulsive Moon flyby to come to a near-circular Moon-trailing orbit. To perform the Earth Orbit Rendezvous (EOR), a second Dragon capsule is then launched from Earth and a similar lunar flyby is performed to rendezvous with the ERV. The requirements for rendezvous, close proximity operations and capture of the sample canister are described. A concept of operations for sample retrieval is presented along with design specifications of the ERV, the required modifications to the Dragon capsule, as well as the hardware, software, sensors, actuators, and capture mechanisms used. In our concept, a container is mounted to the front hatch of Dragon, capable of accommodating the sample canister and sealing it from the rest of the capsule. The sample canister is captured using a robotic arm with a magnetic grappling mechanism. Dragon then performs a propulsive maneuver to return to Earth for a controlled re-entry while the ERV (sans sample container) is left in the Moon trailing orbit. Contingency cases and related mitigation strategies are also discussed, including the advantages and disadvantages of performing the ERV rendezvous with a crew.

Faber, Nicolas F.↗

Demonstration of reconstruction-free static magnetic control of DIII-D plasma with deep reinforcement learning

This paper presents the development and experimental validation of a reinforcement learning (RL)-based magnetic controller on the DIII-D tokamak. The controller directly maps raw magnetic diagnostic signals to actuator commands, replacing the traditional isoflux control algorithm based on equilibrium reconstruction. Four RL controllers are trained using the Soft Actor–Critic algorithm with an asymmetric Actor–Critic architecture in the NSFsim simulator. All controllers are deployed in the DIII-D Plasma Control System and operated with a 4 kHz feedback loop. Two randomization strategies are evaluated during training: evolving kinetic profiles and fixed kinetic profiles within each episode. The latter approach is found to better capture experimental deviations in the current density profile and to provide overall improved control performance. Robust operation is demonstrated across heating power scans in both L- and H-mode plasmas, as well as during transient events such as L–H transitions and pellet injections. Control errors in plasma shape and radial position remained within 1.5–2.0 cm and 1 cm, respectively. A notable discrepancy was observed in the vertical X-point position, with errors of up to approximately 4 cm, attributed to the current density distribution mismatches between simulations and experiments.

DIII-D↗

Effects of a magnetic field on hot electron generation from laser-plasma instabilities

We performed two-dimensional simulations of turbulent laser-plasma instabilities in the presence and absence of external magnetic fields using the Laser Plasma Simulation Environment (LPSE) code. The results demonstrate that, in the presence of a magnetic field, the transition from ballistic to gyrating electron motion enhances the energy transfer from electron plasma waves to the electron population. Although stronger magnetic fields produce a larger population of hot electrons, these electrons tend to remain confined near the quarter-critical density, where the instabilities also localize, thereby reducing the potential for hot electron transport deeper into the target. Additionally, we present a scaling analysis that quantifies hot electron generation as a function of plasma electron temperature, density scale length, and applied magnetic field strength. These findings may have important applications for controlling hot electron flux and mitigating preheat in inertial confinement fusion targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fiber optic and laser sensors VIII; Proceedings of the Meeting, San Jose, CA, Sept. 17-19, 1990

This issue presents topics on the advances in fiber-optic sensor technology, fiber-optic gyroscope, fiber-optic position and pressure sensors, fiber-optic magnetic and temperature sensors, and generic fiber-optic sensors. Papers included are on a novel analog phase tracker for interferometric fiber-optic sensor applications, recent development status of fiber-optic sensors in China, the magnetic-field sensitivity of depolarized fiber-optic gyros, a depolarized fiber-optic gyro for future tactical applications, fiber-optic position transducers for aircraft controls, and a metal embedded optical-fiber pressure sensor. Attention is also given to a fiber-optic magnetic field sensor using spectral modulation encoding, a bare-fiber temperature sensor, an interferometric fiber-optic accelerometer, improvement of specular reflection pyrometer, a theoretical analysis of two-mode elliptical-core optical fiber sensors, and a fiber probe for ring pattern.

Depaula, Ramon P.↗

Data Reproducibility of Spin-Echo Small-Angle Neutron Scattering Instruments

Spin-echo small-angle neutron scattering (SESANS) is a unique method to measure structures of materials in real space with length scales from ∼ 30 μm to ∼20 µm. As shown in Figure 1, the accessible length scale of SESANS is given by its ability to encode the momentum transfer into the Larmor phase, namely Φ = $\vec{𝛿}$ ⋅ $\vec{𝑄}$, where $\vec{𝑄}$ is the momentum transfer and $\vec{𝛿}$ is the encoding vector of the setup and its projection along Q (δQ) is called spin-echo length (SEL). The spin echo length, which is synonymous with the spatial correlation distance probed, is defined as the following 𝛿𝑄 ∝ 𝜆 2 𝐵𝐿cot𝜃 where 𝜆 is neutron wavelength, B is magnetic field, L is length of the parallelogram magnetic field region, and 𝜃 is the angle between the inclined magnetic field boundary and the beam direction, as shown in Figure 1. The result of the SESANS experiment is a Hankel transformation of the SANS scattering function I(Q), which yields the correlation function of the sample in real space.

47 OTHER INSTRUMENTATION↗

Laser Network US Experiments at the University of Texas at Austin

Under Subcontract B638654, The University of Texas at Austin (UT Austin) Center for High Energy Density Science supported three Laser Network US experiments and conducted upgrade planning for the Texas Petawatt Laser Facility. For the experiment “Investigation of the physics of MeV X-ray and particle generation using Compound Parabolic Concentrators” led by Dr. Andrew Mackinnon of Lawrence Livermore National Laboratory, UT Austin provided postdoctoral associate support in the person of Dr. Ganesh Tiwari. For the experiments “Megatesla magnetic fields and enhanced gamma-ray beam generation” led by Hans Rinderknecht of LLE, University of Rochester (experiment) and Alexey Arefiev of UC San Diego (theory) and “High resolution imaging of resonately accelerated electrons under tight focusing” led by Deepak Kumar of ELI-Beamlines, Czech Republic, UT Austin provided the Texas Petawatt Laser staff and a prorated share of the materials and supplies approximately equal to the average of those required for one 5-week experimental campaign. Summaries of these three experiments are provided in this report. Two staff members were hired—Dr. Sandra Bruce at 40% and Dr. Erhard Gaul at 50% time—to support Texas Petawatt Laser maintenance and operations and to plan for the Texas Relativistic Intensity Ultrafast Multi-beam Plasma Facility (TRIUMPF).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pacific-North American plate motion from very long baseline interferometry compared with motion inferred from magnetic anomalies, transform faults, and earthquake slip vectors

Geodetic VLBI measurements were used to test whether the Pacific-North American plate velocity averaged over several years of direct observation (1984-1987) equals that averaged over millions of years. It was also tested whether this velocity parallels the San Andreas fault, transform faults and earthquake slip vectors in the Gulf of California, and earthquake slip vectors along the Queen Charlotte fault, along the Alaskan peninsula, and along the Kamchatkan peninsula. The VLBI data provide an estimate of the direction of plate motion that is independent of estimates from fault azimuths and earthquake slip vectors. The Euler vector determined from VLBI was found to be nearly identical to the Euler vector of plate motion model NUVEL-1, which is based on the trends of transform faults, earthquake slip vectors, and spreading rates from marine magnetic anomalies that average motion since 3 Ma. The velocity between the Pacific and North American plates averaged over the past several years equals or nearly equals its velocity averaged over the past several million years, the difference along their boundary nowhere exceeding 4 + or - 7 mm/yr.

Argus, Donald F.↗

Metalloborophenes: Structural Diversity and Emerging Properties of Metal–Boron Two‐Dimensional Frameworks

Metalloborophenes, an emerging subclass of 2D materials, have attracted growing attention owing to their exceptional structural diversity and highly tunable electronic and magnetic properties. Constructed from vacancy‐rich borophene frameworks stabilized by electron donation from incorporated metal atoms, metalloborophenes merge the chemical versatility of boron with the functional richness of metal dopants. The first experimental realization of Cu–borophene nanoribbons in 2024 marked a pivotal advance, confirming long‐standing theoretical predictions and revitalizing interest in this new frontier of boron‐based 2D chemistry. Despite this progress, most studies to date remain conceptual and theoretical, constrained by challenges in scalable synthesis, dopant precision, and substrate control. Computational investigations have revealed a broad landscape of stable metalloborophene structures, exhibiting metallic, semiconducting, and magnetic behavior across diverse dopant families, including alkali, alkaline‐earth, transition, and lanthanide elements. These tunable characteristics open promising avenues for applications in spintronics, catalysis, and hydrogen storage. This review provides a comprehensive overview of metalloborophenes, emphasizing the interplay between structure, stability, and functionality, and outlining future directions toward bridging predictive modeling with experimental realization of this rapidly evolving class of 2D materials.

2D materials↗

Reconstruction of current profiles from external magnetic and MSE measurements on DIII-D

This work introduces a new current model into the EFIT code for plasma current profile reconstruction. Using this model, edge-localized current density profiles are reconstructed solely from external magnetic measurements. Quantitative comparisons show that edge current profiles obtained with the new current model align closely with those from kinetic equilibrium reconstruction. The new model enables current density reconstruction with fewer diagnostics than kinetic equilibrium reconstruction (Lao et al 1990 Nucl. Fusion 30 1035–49), demonstrating that edge-localized current density information can be obtained from external magnetic measurements only, without the help of kinetic profiles and internal diagnostics, and without using the bootstrap current model. Furthermore, with the constraints of external magnetic and MSE measurements, current profiles in full radius obtained from the new model are in good agreement with the results of kinetic equilibrium reconstruction, which not only improves the efficiency of current reconstruction but also helps avoid possible errors caused by different kinds of diagnoses. Possible applications are also discussed, and a brief analysis of the evolution of the full-radius current density is performed. Noticeable decreases in both the magnitude and gradient of the edge current around the time of ELM bursts are observed. Moreover, analysis of the full radius current density profiles ( ρ N = 0 − 1.0, ρN denotes to square root of the normalized toroidal flux) reveals that as the edge current changes, the inner current also changes following a sinusoidal-like pattern at almost all time slices during four type-I ELMs in discharge 161493. The current evolution in the inner region ( ρ N = 0.2 − 0.6) is synchronized with the boundary region ( ρ N = 0.89 − 1.0), while the intermediate region ( ρ N = 0.6 − 0.89) shows opposite behavior. This sinusoidal-like variations in full-radius current density profile indicates strong core-pedestal coupling, suggesting ELMs significantly affect core plasmas, though current changes manifest differently across radial regions.

EFIT↗

Giant Exfoliation Induced Magnetic Coercivity in Fe 3 GaTe 2

Permanent magnets with strong anisotropy and high coercivity underpin modern information and energy technologies, yet rare-earth-free alternatives remain limited. Here, we show that thickness engineering via mechanical exfoliation induces hard magnetic behavior in the van der Waals ferromagnet Fe 3 GaTe 2 . Bulk crystals exhibit Curie temperatures above 350 K but negligible room-temperature coercivity. When thinned below ∼100 nm, the coercive field is dramatically enhanced, reaching nearly 1 T at room temperature for in-plane fields—comparable to conventional hard magnets. Micromagnetic analysis reveals a crossover in magnetization reversal from domain-mediated processes in bulk samples to quasi-coherent rotation in thin flakes, driven by increased effective anisotropy and suppressed domain formation. This thickness-dependent transition enables tuning of magnetic hardness without chemical modification. Combined with high saturation magnetization and robust room-temperature performance, Fe 3 GaTe 2 emerges as a promising rare-earth-free material for spintronic applications. Its layered structure further allows integration into van der Waals heterostructures, where large in-plane coercivity can stabilize magnetic states against perturbations and interlayer coupling, offering potential for high-density nonvolatile memory and domain-wall-based devices.

36 MATERIALS SCIENCE↗