Programmable high voltage power supply with regulation confined to the high voltage section

A high voltage power supply in a dc-dc converter configuration includes a pre-regulator which filters and regulates the dc input and drives an oscillator which applies, in turn, a low voltage ac signal to the low side of a step-up high voltage transformer. The high voltage side of the transformer drives a voltage multiplier which provides a stepped up dc voltage to an output filter. The output voltage is sensed by a feedback network which then controls a regulator. Both the input and output of the regulator are on the high voltage side, avoiding isolation problems. The regulator furnishes a portion of the drive to the voltage multiplier, avoiding having a regulator in series with the load with its attendant, relatively high power losses. This power supply is highly regulated, has low power consumption, a low parts count and may be manufactured at low cost. The power supply has a programmability feature that allows for the selection of a large range of output voltages.

Castell, Karen D.↗

Bipolar Membrane Electrodialyzers as Flexible Demand Response Resources: Co-Optimization of Cost Savings and Product Formation

Bipolar membrane electro dialyzers (BPMED) are widely used for chemical production and processing, including in the emerging ocean alkalinity enhancement (OAE) industry. In this paper, we explore the potential of BPMED devices as flexible electrochemical loads within power system operations. Using a multi-objective optimization framework, we evaluate BPMED operation across 24-hour and monthly horizons to examine how dispatch strategies respond to electricity price and grid conditions. Simulation results show that altering the relative weights of the choices in the objective function strongly shape the operating patterns, with cost-focused strategies that suppress the operation during peak prices. Furthermore, we propose alternative formulations that optimize operations to achieve both cost savings and alignment with periods of lower grid-side carbon intensity (CI), as low grid-side CI is key to maximize OAE efficiency. Additionally, a detailed sensitivity analysis highlights the importance of device properties, where low area-specific resistance (ASR) of membrane and high current efficiency (CE) are observed to jointly unlock cost-effective operation. However, even modest shunt efficiency losses are observed to erode performance and decrease system value. Importantly, the analysis demonstrates that BPMED can serve as a controllable and flexible demand response resource, shifting load to support multiple grid-side objectives, including (but not limited to) renewable integration, alleviate peak demand, and provide co-benefits for system reliability. These findings underscore BPMED’s dual role as a process technology and a grid-supporting asset, pointing to promising pathways for operational optimization of multiple objectives.

Bhattacharya, Saptarshi (ORCID:0000000308902060)↗

Sulfurized Polyacrylonitrile for High-Performance Lithium–Sulfur Batteries: In-Depth Computational Approach Revealing Multiple Sulfur’s Reduction Pathways and Hidden Li + Storage Mechanisms for Extra Discharge Capacity

Like no other sulfur host material, polyacrylonitrile-derived sulfurized carbon (SPAN) promises improved electrochemical performance for lithium–sulfur batteries, based on its compatibility with carbonate solvents and ability to prevent self-discharge and shuttle effect. However, a complete understanding of the SPAN’s lithiation mechanism is still missing because its structural features vary widely with synthesis conditions, and its electrochemical performance deviates from elemental sulfur. This study continues our research on the elucidation of the SPAN’s structural characteristics and lithiation mechanisms via computational approaches. Here, our models reproduce most experimental data regarding carbon’s graphitization level and conjugated ordering, sulfur–carbon covalent bonding, sulfur loading, and elemental composition. Our simulations emulate the discharge voltage observed in experiments for the first discharge, which reveals that sulfur follows multiple reduction pathways based on its interaction with the carbon backbone. Sulfur reduction takes place above 1.0 V vs Li/Li + mostly in the SPAN-like material, with no long-chain lithium polysulfide formation. Below 1.0 V vs Li/Li + , the backbone’s electrochemical activity occurs via multiple C–Li and N–Li interactions, mostly with edge carbon atoms and pyridinic nitrogen. Moreover, we identify Li + binding sites throughout the graphitized backbone that might lead to prohibited energy costs for Li + deintercalation, which may explain the irreversible capacity loss between the first and second discharges. This work improves understanding of lithiation mechanisms in sulfurized carbon, which is useful for rationally designing SPAN synthesis pathways tailored to increase sulfur loading and enhanced electrochemical performance.

25 ENERGY STORAGE↗

Iteration-based Linearized Distribution-level Locational Marginal Price for Three-phase Unbalanced Distribution Systems

Distributed energy resources (DERs) are rocking the utilities’ business landscape. It calls for competitive market environments that incentivize DERs to form maximum operating efficiency. Among proposed pricing schemes, distribution-level locational marginal price (DLMP) is effective in signaling the marginal generation cost differences driven by energy losses and network constraints. It can be derived from a distribution-level optimal power flow (OPF) framework, as it essentially presents the sensitivity of optimized generation cost towards incremental loads. However, due to the high resistance-to-inductance ratio and unbalanced characteristics of distribution networks, computational affordable DLMPs are highly challenged. This article provides a linear-approximated DLMP that can be solved efficiently and generalized to account for reactive power flow, three-phase unbalanced loads and meshed network structure. The successive linear programming technique is introduced to enhance the model accuracy. Case studies on an IEEE 123-Bus system validate its accuracy against a nonlinear benchmark and capability in offering proper incentives.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Austin Sustainable and Holistic Integration of Energy Storage and Solar PV [Austin SHINES]. Final Report, Version 2

The Austin SHINES project and solution is a software management platform, for an electric grid with a high penetration of dispersed photovoltaic (PV) solar generation sites, which maintains the traditional power quality and reliability associated with grid service. This project developed and deployed the platform as a Distributed Energy Resource Management System (DERMS), engaging multiple advanced controls, to evaluate operation and optimization of a fleet of diverse DER assets, installed at several locations among Austin Energy’s customers and distribution system. The project also produced a methodology to create a replicable DERMS template, adaptable to other regions and market structures. Last, Austin SHINES aimed to demonstrate the solution’s methodology would enable the DER grid ecosystem to serve load at a technical cost (System Levelized Cost of Electricity, or System LCOE) of less than the U.S. Department of Energy SHINES program metric of $0.14/kWh, in a defined boundary, while enabling a high penetration of distributed PV. Research was categorized in 6 reports (Final Deliverables = FD) listed below, with titles and descriptions indicating which area of understanding was investigated: FD-1: System Levelized Cost of Electricity (System LCOE) Methodology The creation and use of the System LCOE to Serve Load metric that encompasses the holistic, system-level costs and benefits of all resources, and enables them to be evaluated based on their ability to support an efficient and low-cost integrated grid ecosystem. FD-2: Software Platform Product Description The creation of new DER control methodologies deployable within a utility-grade software platform that enable DER's to maximize their benefit within a grid, that is capable of serving load enabling a high penetration of distributed PV generation. FD-3: Optimal Design Methodology Optimal design methodologies for individual DER installations that enable utilities to determine the optimal combinations and sizing for individual DER sites. FD-4: Austin SHINES Ownership and Operation Models for DER System Performance A comparison of multiple DER aggregation and ownership methodologies including direct utility control, third-party aggregator, and autonomous. FD-5: Economic Modeling & Optimization A comparison of multiple DER technology mixes and configurations within the distribution system, providing insight into an optimal blend of technologies that best enable the distribution system to serve load at the lowest cost at high penetrations of solar. FD-6: Fielded Assets Deployed DER assets within the Austin Energy SHINES circuits. Austin SHINES provided an opening for state-of-the-art technology products to be deployed, providing a rich opportunity for improving how each of the products perform as stand-alone products, and in concert with other complementary products. The Austin SHINES project comprised of two key metrics for System LCOE: SystemLCOE_SHINES<$0.14/kWh Modeled ΔSystemLCOE_SHINES/ΔSystemLCOE_Base≥20% at same solar penetration The System LCOE calculation uses the costs of the utility-owned infrastructure as it exists today, the cost of the DERs that exist in the system today, and the cost of the purchase of energy from ERCOT wholesale markets over the course of the calendar year. All costs are on an annualized basis. The capital and operating costs are derived from the rate case, which produces a yearly cost. The net cost of energy and services imported to the system is integrated over the test year, as is the load served and solar penetration. The first metric was easily achieved by every scenario considered. The goal was set when the Department of Energy’s SHINES Funding Opportunity Announcement was written in 2015 and was a more difficult target at the time. Due mostly to rapidly declining costs for DERs and the significant decrease in the Electric Reliability Council of Texas (ERCOT) energy market prices, which results in lower net cost of energy purchases, the System LCOE is well below this target for all scenarios considered. A fleet of DERs can assume different mixtures, each of which serves the load at a different LCOE. The optimal mixture of DERs serves load at the smallest System LCOE. The second metric (hereinafter %delta metric) asks that the holistic DERMS controls reduce the incremental cost above the baseline of going to a high solar penetration future by at least 20% as compared to the case of a DER deployment with no sophisticated controls (autonomous). Many comparison sets were created throughout this project. Physical technology was installed for informing utility engineering and testing several types of operational control schemes, through the DERMS. The types of operational control which were compared for valuation of the System LCOE Metric were: Holistic control = using the full suite of the DERMS platform to decide and optimize how/why the systems operate depending on weather, market, and reliability signal input. Autonomous control = a local mode at the asset site, wherein a schedule operates the asset, with visibility into performance only No control = the baseline for comparing value against the other two types of control The types of ownership control included: Direct Utility control = the utility dispatches a signal to each asset Third-Party Aggregator = a third party aggregates a fleet of assets and the utility dispatches one signal for all Autonomous = a local mode is set for operation at the asset site, wherein a schedule operates the asset, with visibility into performance only The types of control methodologies deployable within a utility-grade software platform included: Utility Peak Load Reduction = Lower transmission cost obligation Day-Ahead Energy Arbitrage = Realize economic value through price differential Real-Time Price Dispatch = Realize economic value from real-time price spikes Voltage support = Reduce losses and increase solar generation Distribution Congestion Management = Increase local grid reliability Demand Charge Reduction = Lower customer bills and realize system benefit The fielded assets deployed for the project were: Utility Scale Kingsbery Energy Storage System: 1.5 MW / 3 MWh Li-Ion battery storage Mueller Energy Storage System: 1.75 MW / 3.2 MWh Li-Ion battery storage, 7 Energy Storage Units (250 kW each) La Loma Community Solar: 2.6 MW Commercial Scale Aggregated storage installations at 3 sites, with existing solar (300+ kW): One 18 kW / 36 kWh Li-Ion battery storage Two 72 kW / 144 kWh Li-Ion battery storage Residential Scale Aggregated storage installations: -Six stationary battery storage systems (10 kWh each) at homes with existing solar -One Electric Vehicle installed as Vehicle-to-Grid (V2G) Utility-Controlled Solar via Smart Inverters at 12 homes Autonomously-Controlled Smart Inverters at 6 homes Over the course of the project, Austin SHINES undertook installing more than 3 MW of distributed battery energy storage, smart PV inverters, a DER control platform, and other enabling technologies utilizing customer and utility locations and aggregation models. All of these resources were to be integrated and optimized at the utility level. DER assets and control methodologies were designed to achieve a credible pathway to a System LCOE for energy delivered to load of $0.14//kWh or less by 2020, while maximizing distributed solar generation and maintaining acceptable standards of power quality. The project also established a template for other regions to follow, to maximize the adoption of distributed solar PV in support of an economic and efficient grid. In total, the Austin SHINES project added value to the DER subject area in each layer of integration. From utility, to commercial to residential scales, the sheer hierarchy of communication and coordination was a significant accomplishment in addition to learnings from what these communications revealed was unique to each. Economically, the most effective method demonstrated was the criticality of planning phases. Contingencies and multiple projection scenarios helped guide the project to deploy optimal design as close as feasible, in real world conditions. The project and reports will serve public benefit by outlining specific areas of DER strategy and installation where many stakeholders and needs can be addressed with improved efficiency. Overall, communities and utilities should use the results to guide the increasing options available for powering the grid with DER, renewables, and carbon considerate energy.

14 SOLAR ENERGY↗

A Preliminary Investigation on the Cost Reduction Potential of Optimizing Bore Fields for Commercial Ground Source Heat Pump Systems

The high initial cost of ground heat exchangers (GHE) is a primary hurdle preventing wider adoption of ground source heat pump (GSHP) systems. GHEs used for commercial GSHP systems commonly consist of vertical boreholes installed on a grid with equal spacing between boreholes. Significant thermal loads require a large number of boreholes to be present in the field. However, due to thermal interactions among boreholes, the ground formation in the center of a bore field can, over time, become thermally saturated when the thermal load is not balanced on an annual basis. The loss of effectiveness due to thermal saturation at the center boreholes in regularly spaced borehole fields suggests that larger spacing near the center of the bore field could be more optimal, and in return reduce initial costs. Through computer simulations using the latest development of a GHE modeling tool, this study evaluates the impacts of various unconventional designs of the borehole field on the performance and cost of the GHEs of a typical commercial GSHP system. The unconventional designs include irregular spacing among boreholes with decreased spacing around the perimeter and increased spacing in the interior of the field. The unconventional bore field design shortens the total drilling length by up to 42% while giving better heat transfer performance than a conventional bore field design. The significant total bore length reduction is due to improved heat transfer effectiveness of each borehole in the unconventional bore field.

Spitler, Jeffery↗

Understanding Line Losses and Transformer Losses in Rural Isolated Distribution Systems: Preprint

Rural, isolated power systems in the mainland U.S. and in states like Alaska and Hawaii are powered by assets like diesel generators. These rural, isolated power systems also cannot operate at the higher band of medium voltage (like 69kV). They are primarily in the 12 to 14 kV range to keep the cost of the distribution investments lower. Because of this mid-band medium voltage range, the line losses and distribution transformers losses consume significant diesel consumption (almost 10 percent of the peak load). This work considers one such power system powering an isolated system and presents key findings online losses, and transformer losses. Understanding and documenting the impacts is critical for these communities operating their power systems and take actions to reduce expensive diesel consumption. In this paper, we will present one such typical grid and model it in electromagnetic transients (EMT) domain. We used the tower structure, under ground cabling installation to develop high fidelity models of lines. We also used high fidelity models of distribution transformers to present the no-load losses and full load loses. We will also present technical solutions available commercially off-the-shelf to reduce these losses and reduce diesel consumption. This work will be a primer for communities to understand the technical challenges and to understand the possible solution available to solve such challenges for rural, isolated power system operators.

blackstart↗

Achieving high rate performance in hybrid pristine-recycled cathodes using model-informed electrode designs

Direct recycling lithium-ion battery cathodes, a process that retains the engineered oxide structures from end-of-life materials, presents a cost-effective and energy-efficient alternative to other battery recycling methods. However, while direct-recycled cathodes have demonstrated performance comparable to that of pristine materials at low cycling rates, their high-rate performance remains uncertain. Morphology changes in cathode particles, a main mode of degradation, directly impact rate performance by limiting surface kinetics and solid-phase diffusion. If direct recycling processes do not sufficiently restore pristine-like morphologies, the recycled materials may retain structural defects that hinder high-rate performance. The present work uses a physics-based pseudo-2D model to simulate hybrid electrodes with pristine and artificially “aged/recycled” NMC materials to investigate potential impacts of incorporating performance-limited aged cathode materials into cells. The study highlights how differences in transport and kinetic properties can influence rate capabilities in mixed electrodes — particularly in high-loading cells in high-demand applications. However, model results also reveal a possible mitigation strategy via dual-layer electrode architectures with lower-performing materials positioned near the current collector. Simulations of 4.0 mAh cm −2 cells cycled at 4C using a dual-layer architecture provided approximately 5%–30% more capacity in constant-current protocols compared to homogeneously blended electrode architectures with the same loadings and mixed-material compositions. These findings highlight the importance of strategic electrode design in minimizing potential performance losses and facilitating the integration of recycled materials into high-performance batteries, advancing sustainable and cost-effective battery manufacturing.

25 ENERGY STORAGE↗

A Comprehensive Approach towards Multi-Objective EMI Filter Design Optimization in High-Frequency SiC-Based Motor Drives

With rapid penetration of high-frequency, highdensity power electronics into the industry, controlling the system generated EMI becomes one of the major design challenges. Designing practical optimized EMI filters require simultaneous consideration of multiple aspects - including electromagnetic couplings, magnetic materials, practical component parasitics and their impacts at high-frequencies, and also the overall manufacturing costs. The multi-dimensional nature of the problem often results in overcompensated designs that hurt the system efficiency and power density. This paper focuses on a comprehensive design platform (developed in MATLAB) towards designing high-density, optimized, highly efficient EMI filters by analyzing the generated noise spectrum and evaluating a vast array of potential solutions before outputting an optimized filter solution. The proposed tool includes database-based component selection, optimal topology selection, multistage filter design, overall optimization for volume, mass, cost and total loss. The proposed filter has been thoroughly evaluated in a PSIM simulation environment emulating the hardware in CRD300DA12EXM3, a 300kW three-phase inverter from Wolfspeed with an RL load representing a motor drive application. Furthermore, a 20kHz switching frequency is chosen and impacts of the motor high-frequency characteristics on the generated EMI noise spectrum of the overall system have been analyzed.

42 ENGINEERING↗

The Relationship Between Constraint and Ductile Fracture Initiation as Defined by Micromechanical Analyses

The use of small laboratory specimens to predict the integrity of large, complex structures relies on the validity of single parameter fracture mechanics. Unfortunately, the constraint loss associated with large scale yielding, whether in a laboratory specimen because of its small size or in a structure because it contains shallow flaws loaded in tension, can cause the breakdown of classical fracture mechanics and the loss of transferability of critical, global fracture parameters. Although the issue of constraint loss can be eliminated by testing actual structural configurations, such an approach can be prohibitively costly. Hence, a methodology that can correct global fracture parameters for constraint effects is desirable. This research uses micromechanical analyses to define the relationship between global, ductile fracture initiation parameters and constraint in two specimen geometries (SECT and SECB with varying a/w ratios) and one structural geometry (circumferentially cracked pipe). Two local fracture criteria corresponding to ductile fracture micromechanisms are evaluated: a constraint-modified, critical strain criterion for void coalescence proposed by Hancock and Cowling and a critical void ratio criterion for void growth based on the Rice and Tracey model. Crack initiation is assumed to occur when the critical value in each case is reached over some critical length. The primary material of interest is A516-70, a high-hardening pressure vessel steel sensitive to constraint; however, a low-hardening structural steel that is less sensitive to constraint is also being studied. Critical values of local fracture parameters are obtained by numerical analysis and experimental testing of circumferentially notched tensile specimens of varying constraint (e.g., notch radius). These parameters are then used in conjunction with large strain, large deformation, two- and three-dimensional finite element analyses of the geometries listed above to predict crack initiation loads and to calculate the associated (critical) global fracture parameters. The loads are verified experimentally, and microscopy is used to measure pre-crack length, crack tip opening displacement (CTOD), and the amount of stable crack growth. Results for A516-70 steel indicate that the constraint-modified, critical strain criterion with a critical length approximately equal to the grain size (0.0025 inch) provides accurate predictions of crack initiation. The critical void growth criterion is shown to considerably underpredict crack initiation loads with the same critical length. The relationship between the critical value of the J-integral for ductile crack initiation and crack depth for SECT and SECB specimens has been determined using the constraint-modified, critical strain criterion, demonstrating that this micromechanical model can be used to correct in-plane constraint effects due to crack depth and bending vs. tension loading. Finally, the relationship developed for the SECT specimens is used to predict the behavior of circumferentially cracked pipe specimens.

Panontin, Tina L.↗

Solar+ Optimizer: A Model Predictive Control Optimization Platform for Grid Responsive Building Microgrids

With the falling costs of solar arrays and battery storage and reduced reliability of the grid due to natural disasters, small-scale local generation and storage resources are beginning to proliferate. However, very few software options exist for integrated control of building loads, batteries and other distributed energy resources. The available software solutions on the market can force customers to adopt one particular ecosystem of products, thus limiting consumer choice, and are often incapable of operating independently of the grid during blackouts. In this paper, we present the “Solar+ Optimizer” (SPO), a control platform that provides demand flexibility, resiliency and reduced utility bills, built using open-source software. SPO employs Model Predictive Control (MPC) to produce real time optimal control strategies for the building loads and the distributed energy resources on site. SPO is designed to be vendor-agnostic, protocol-independent and resilient to loss of wide-area network connectivity. The software was evaluated in a real convenience store in northern California with on-site solar generation, battery storage and control of HVAC and commercial refrigeration loads. Preliminary tests showed price responsiveness of the building and cost savings of more than 10% in energy costs alone.

14 SOLAR ENERGY↗

SolarPlus-Optimizer v0.1

With the falling costs of solar arrays and battery storage and reduced reliability of the grid due to natural disasters, small-scale local generation and storage resources are beginning to proliferate. However, very few software options exist for integrated control of building loads, batteries and other distributed energy resources. The available software solutions on the market can force customers to adopt one particular ecosystem of products, thus limiting consumer choice, and are often incapable of operating independently of the grid during blackouts. In this software package, we present the "Solar+ Optimizer" (SPO), a control platform that provides demand flexibility, resiliency and reduced utility bills, built using open-source software. SPO employs Model Predictive Control (MPC) to produce real time optimal control strategies for the building loads and the distributed energy resources on site. SPO is designed to be vendor-agnostic, protocol-independent and resilient to loss of wide-area network connectivity. The software was evaluated in a real convenience store in northern California with on-site solar generation, battery storage and control of HVAC and commercial refrigeration loads. Preliminary tests showed price responsiveness of the building and cost savings of more than 10% in energy costs alone.

Prakash, AnandKrishnan↗

Optimal operation of multi-plant steam district heating systems for enhanced efficiency and sustainability

Despite their crucial role in supplying heat and power to universities, industries, and healthcare facilities, many steam-based district heating systems rely on outdated control methods. Among these, multi-central plant districts are particularly challenging due to the complexities of coordinating multiple plants, optimizing load distributions, and managing system downtime. In response, new operational strategies are developed to enhance the efficiency and sustainability of steam districts while utilizing existing resources. These strategies include reducing plant operational pressure without compromising the reliable supply to buildings and optimizing load allocation across multiple plants. The load allocation considers boiler part-load efficiency, runtime, network losses, and building pressure set points, and is compared with traditional multi-boiler controls. To support this exploration, new dynamic Modelica models are developed. In addition, methods to reduce modeling complexities are incorporated, enhancing their suitability for practical applications. A holistic district-wide analysis using a real university case study demonstrates a 4.7% fuel savings by lowering boiler operational pressure from 900 kPa to 600 kPa, along with a 13.3% reduction in condensation losses across the distribution network. Furthermore, the load allocation approach results in a 13.1% reduction in fuel consumption during peak winter periods and 15.3% during shoulder periods, with corresponding decreases in carbon emissions and fuel costs. This approach can also save maintenance costs by reducing the boiler runtime by 49.6%. In conclusion, this research underscores the benefits of retrofitting aging steam district heating systems, offering immediate operational improvements by enhancing efficiency, meeting regulatory compliance, and extending infrastructure lifespans while delaying costly overhauls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microgrid Assisted Design for Remote Areas

In this work, we present a three-stage multiobjective mixed-integer linear programming (MILP) for the optimal expansion planning and operation of isolated multienergy microgrids in remote areas. By selecting the optimal distributed generators (DGs) and energy storage systems (ESSs) mix selection, siting, sizing, and scheduling in the remote microgrid, the proposed model is targeted to minimize the annualized total cost of microgrids while enhancing the performance of the system, i.e., minimizing the voltage deviations and line power loss. To represent the electricity and heat flow between generation resources and various electrical, heating, and cooling loads in the isolated microgrid, linearized power flow, and heat flow constraints are employed in the proposed optimization model. The available capacity of DGs and ESSs are modeled as discrete constants instead of continuous variables for practical purpose. Numerical simulation results on a remote microgrid consisting of DGs, ESSs, and various loads validate the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Highly Loaded Low Pressure Turbine (LPT)

The goal of this study is to evaluate aspirated and non-aspirated aerodynamics on highly loaded LPT design. The objective is to increase stage loading by 30 to 50 percent without loss of efficiency for an existing low pressure turbine design. A study conducted on a NASA highly loaded multistage fan drive turbine (NASA CR-1964) indicated that end-wall bleed at the hub is a more significant parameter compared to aspirated airfoil. Based on this study, a 3-stage LPT is redesigned to 2-stage LIT with and without end-wall bleed. Both aerodynamic design and mechanical design are completed. In addition to end-wall bleed, exit guide vanes are designed with aspirated airfoils to reduce the losses. The LPT is redesigned with all constraints necessary for practical application. The benefit of the high-performance, highly loaded LPT shows up in reduced stage and part count, reduced size and weight, and reduced cost.

Ortiz, Milt↗

A High-Efficient Solution for Electro-Hydraulic Actuators with Energy Regeneration Capability

This paper proposes a cost-effective, robustly practical solution for a high-efficient electro-hydraulic actuator (EHA) for linear drives. The solution addresses the challenges of high costs and limited efficiency that limit the application of EHA for the electrification of many off-road vehicles. Based on a variable-speed electric motor and a low-cost technology for a fixed-displacement pump, the proposed solution is suitable for a compact implementation and it is capable of energy regeneration under overrunning load conditions. Two different architectures—an open circuit and a closed circuit one—are considered to determine the most practical and efficient configuration as well as the control features. Both architectures minimize throttling losses associated with the conventional regulation of hydraulic actuators. Actuator velocities below the minimum and beyond the maximum allowable pump flow rate are achieved in both architectures using a proportional valve that bypasses the pump flow. The paper describes the design methodology as well as the simulation and experimental activities performed to verify the control strategies as well as energy efficiency. Considering an EHA system of about 20 kW, a complete efficiency map of the system is determined for all the possible four quadrants of operation thus including both resistive and overrunning loads, where energy recuperation is implemented. Simulation and experimental results show that the energy efficiency of the hydraulic systems can reach 84.7% in resistive phases. In assistive phases, the hydraulic system can recover up to 81.8% of the actuator energy. Here, the comparison between open-circuit and closed-circuit structures shows the advantages of the former in terms of energy efficiency. The proposed solution is suitable for electrified hydraulic actuation systems, in both industrial and mobile applications. With the advantages of the low cost of the hydraulic unit and high energy efficiency, it is particularly suitable for mobile applications such as construction machines, that are recently experiencing a significant electrification trend.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of a 3-D boundary layer code to predict heat transfer and flow losses in a turbine

The prediction of the complete flow field in a turbine passage is an extremely difficult task due to the complex three dimensional pattern which contains separation and attachment lines, a saddle point and horseshoe vortex. Whereas, in principle such a problem can be solved using full Navier-Stokes equations, in reality methods based on a Navier-Stokes solution procedure encounter difficulty in accurately predicting surface quantities (e.g., heat transfer) due to grid limitations imposed by the speed and size of the existing computers. On the other hand the overall problem is strongly three dimensional and too complex to be analyzed by the current design methods based on inviscid and/or viscous strip theories. Thus there is a strong need for enhancing the current prediction techniques through inclusion of 3-D viscous effects. A potentially simple and cost effective way to achieve this is to use a prediction method based on three dimensional boundary layer (3-DBL) theory. The major objective of this program is to assess the applicability of such a 3-DBL approach for the prediction of heat loads, boundary layer growth, pressure losses and streamline skewing in critical areas of a turbine passage. A brief discussion of the physical problem addressed here along with the overall approach is presented.

Vatsa, V. N.↗

Towards a Unified Low-Cost Flow Plate, Flow-Field, PTL Solution for Proton Exchange Membrane Electrolyzers

Proton exchange membrane (PEM) water electrolysis is a highly efficient method for hydrogen production. Research cells typically consist of one proton exchange membrane, two catalyst layers, two porous transport layers, two flow-field plates, and two endplates. In commercial systems, the machined flow-field plates that are employed in research cells are typically replaced by stamped parts or open mesh material solutions to reduce manufacturing cost at scale. Nonetheless, the cell contains about 8 total interfaces: bipolar plate / flow plate material / porous transport medium / electrode / membrane / electrode / porous transport medium / flow plate material / bipolar plate. All these materials and interfaces need to be optimized for maximum performance and efficiency. Reducing the amount of interfaces by combining individual cell components directly benefits the fabrication cost (by reducing the parts count and the needs for surface coatings) and the electrochemical performance (by reducing ohmic losses). We have designed a novel PEM electrolysis cell with a piece of channeled titanium felt functioning as both the anode flow-field and the PTL, referred to as the channeled diffusion layer (CDL). The pores of the felt facilitate both in-plane and through-plane diffusion, ensuring maximum catalyst utilization while also minimizing mass transport loss. The titanium felt can be mass manufactured with existing stamping and forming methods and is therefore a promising candidate to reduce the capital cost of PEM electrolyzers whilst improving hydrogen production efficiency. Experiments conducted with 3mg IrOx/cm2 loading MEAs have shown a approximately 40% boost in peak current by implementing the CDL design. Low catalyst-loading MEAs are being tested in ongoing experiments and their results will be discussed and compared.

08 HYDROGEN↗