Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loading frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Load Control for Frequency Response - A Literature Review

As electricity grids employ greater fractions of renewable energy, which introduce additional variability and uncertainty in the net load, balancing electrical load and generation becomes more challenging. This paper reviews the literature documenting physical simulations and real systems that employ load control (LC) for frequency response and other grid services, which balance net load on the grid and prevent unwanted frequency excursions. Apart from academic and simulation studies, few sources exist on large-scale laboratory hardware testing or actual real-world systems that employ LC for frequency response, and we review them here. Four types of systems that we consider are: 1) Laboratory-based LC experiments, 2) Isolated microgrids that employ LC, 3) Larger grids that employ LC and 4) vehicle-to-grid (V2G) technology, using electric vehicles (EVs). In general, these systems have successfully used LC to meet their objectives, which are often keeping grid frequency within a required band. However, LC struggled to balance grid frequency in an isolated system powered by a single wind turbine, and V2G technology requires refinement in communication and control to provide optimal regulation that adheres to industry standards. As LC grows in the energy industry, we have three main recommendations: 1) encouraging system operators who use LC to publish system characteristics and lessons learned; 2) transitioning more LC theoretical/simulated systems to physical experiments, and physical experiments to real-world pilot systems; 3) demonstrating load control to support isolated, high-wind-contribution systems.

17 WIND ENERGY↗

Physics-based Multiscale Additively Manufactured Superalloy Design for Optimized High Cycle Fatigue Life (Final Report)

The objectives of this project are to: (i) Gain fundamental understandings towards the microscopic damage mechanisms, as impacted by pertinent materials properties (e.g. stacking fault energy (SFE) and microstructure (e.g., grain size), leading to high-cycle fatigue (HCF) damage to AM Ni-based superalloy parts; (ii) Provide scientific insight into the effect of testing frequency on damage mechanisms and fatigue life of AM Ni-based superalloy parts under HCF regime, thereby establishing an appropriate correlation between accelerated testing and materials’ true service life; (iii) Devise an accurate, experimentally validated multiscale model across atomic, micro- and meso-scales, to predict the cyclic stress-strain responses and fatigue damage accumulation for AM Ni-based superalloys under various loading frequencies.

36 MATERIALS SCIENCE↗

An investigation into the effects of cyclic strain rate on the high cycle and very high cycle fatigue behaviors of wrought and additively manufactured Inconel 718

Additive Manufacturing (AM) has increasingly been used to fabricate parts in aerospace applications, which may require service lives beyond ten-million cycles due to the imposed high loading frequencies. Understanding the very high cycle fatigue (VHCF) behavior of these additive manufactured (AM) parts is an important step towards their design and qualification processes. This study focuses on the high cycle fatigue (HCF) and VHCF behaviors of both wrought and laser beam-powder bed fusion (LB-PBF) fabricated Inconel 718 in machined/polished surface condition, emphasizing on the influence of test frequency (i.e., cyclic strain rate). Uniaxial, fully-reversed force- and stress-controlled fatigue tests were conducted utilizing a servo-hydraulic and an ultrasonic test system operating at 5 Hz and 20 kHz, respectively, on wrought as well as LB-PBF vertically and diagonally built specimens. Fatigue cracks in the majority of the specimens were found to initiate from intra-granular slip bands near or at the surface, which gives rise to strong anisotropy in fatigue resistance in LB-PBF specimens due to the presence of columnar grains along the build directions. Longer fatigue lives were obtained at 20 kHz, which was ascribed to possibly lower-than-intended stresses applied in the ultrasonic tests. The corrected stress-life fatigue data at 20 kHz were found to converge to the one obtained from conventional testing at 5 Hz, implying no effect of cyclic strain rate on the fatigue behavior of Inconel 718 regardless of the fabrication process. The findings of this work confirm the use of ultrasonic fatigue testing to expedite generation of AM materials data to keep up with the current demand; however, the applied stress may need to be corrected.

36 MATERIALS SCIENCE↗

Crack Propagation Modeling of a High-Speed Outer Rotor Motor

This study aims to investigate the propagation of initial cracks in electric motors and their rate of spread through the rotor structure under various operating conditions. Traction motors are subjected to high centrifugal load owing to their speed and rapid acceleration and deceleration. In the manufacturing process, some initial imperfections or cracks in the rotor components are likely to occur. Under the influence of loading, these cracks will grow, and factors such as loading frequency, material strength, and location of material voids will affect this threshold speed. In the current study, a fracture mechanics–based approach has been used to investigate the crack growth rate for a 100 kW outer rotor motor with a rated speed of 6,000 rpm and a peak speed of 20,000 rpm for an integrated drive application.

Barua, Himel↗

Implementational Aspects for the Characterization of Low-Inertia in Power Systems

The replacement of conventional generating units with non-conventional renewable energy resources impacts the stability of the power system. While the general goal of supplying demand could be achieved from both generation resources, inverter-based energy resources are different from traditional synchronous machines in the sense that they do not inherently provide inertia to the system. The latter obviously worsen the system ability to maintain the balance between supply and demand after certain contingencies such as generator outages. With high integration of renewable-based generation resources, there is a reduction in total system inertia, which could lead to systems with less time to react for frequency restoration in case of such unexpected unit failures. While conceptually it is true, there is a missing gap in the field of power system stability community in terms of test-bed power systems for characterizing low-inertia conditions. In this paper, a framework for low-inertia power systems is presented. The purpose of the test-bed is to establish an environment for testing and conducting research on power systems experiencing low-inertia issues. The frequency nadir, the rate of change of frequency, and the under-frequency load shedding scheme are used as a measure of the healthiness of power grids.

Baquedano-Aguilar, Mario D.↗

Vulnerability of a VOC-Based Inverter Due to Noise Injection and Its Mitigation

Even though virtual oscillator control (VOC)-based inverters do not communicate with each other, they need to make local measurements for control. The impact of tampering with these measured or sensed signals on the performance of a VOC-based inverter and synchronization of multiple such inverters is an important but open-ended issue. As such, this letter explores the impact of intentional side-channel noise intrusion (SNI) on the synchronization of VOC-based communication-free self-synchronizing inverters (CFSIs). Two different scenarios are investigated via experimental and analytical studies using a half-bridge neutral point clamped (NPC) single-phase CFSI. Furthermore, they address the impact of SNI on the ability of a CFSI to ensure a stable 60-Hz limit cycle and on the parallel operation of two such CFSIs to ensure synchronism to a common 60-Hz load frequency.

42 ENGINEERING↗

Status of the Fuel Fragment Dispersal Studies at Oak Ridge National Laboratory

During a loss-of-coolant accident, a nuclear fuel rods undergo balloon and burst. High burnup fuel is known to fragment and pulverize leading to the potential for the fuel to disperse through the burst opening either during the initial burst or following the burst during the reflood event. This milestone summarizes the design and assembly of a system to study dispersal in a postburst event. Surrogate fuel material (HfO2, tungsten, and yttria-stabilized zirconia [YSZ]) dispersing from as-burst loss-of-coolant accident (LOCA) test specimens was extensively investigated, along with dispersal of actual nuclear fuel following a LOCA Severe Accident Test Station (SATS) test. Surrogate material tests spanned a variety of burst geometries, particle types, particle size distributions, and rod oscillation loadings (frequency and amplitude combinations).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reducing the Cost of Fatigue Crack Growth Testing for Storage Vessel Steels in Hydrogen Gas

Hydrogen storage pressure vessels are designed against fatigue crack growth, and the ASME Boiler and Pressure Vessel Code requires the fatigue crack growth rate (da/dN) vs. stress-intensity factor range (ΔK) relationship of the construction steel to be measured directly in hydrogen gas. These measurements are notoriously slow and expensive: the cyclic loading frequencies prescribed by standards (often 0.1 Hz) are two or more orders of magnitude below those for conventional fatigue testing, individual tests run for days to weeks, and the high-pressure test-chamber set-up imposes a significant per-specimen labor cost. Due to these time and cost constraints, near-threshold data—the regime most valuable for extending design fatigue life—are rarely generated for ferritic storage vessel steels in hydrogen gas.

08 HYDROGEN↗

High frequency medium voltage drive system for high speed machine applications

In one aspect, a medium voltage power converter includes a plurality of slices each having: a transformer including a plurality of primary windings to couple to a utility source of input power and a plurality of secondary windings; and a plurality of power cubes coupled to the plurality of secondary windings, each of the plurality of power cubes comprising a low frequency front end stage, a DC link, and a high frequency silicon carbide (SiC) inverter stage to couple to a high frequency load or to a high speed machine.

Ledezma, Enrique↗

Improving Frequency Stability and Minimizing Load Shedding Events by Adopting Grid-Scale Energy Storage with Grid Forming Inverters

The upward adoption trend of renewable generation not only means cleaner energy integrated into modern power grids, but also that most new generation sources are based on front-end inverter bridges, used as interfaces to most wind generation and all the solar PV. It is well known that due to their power electronics-based construction rather than rotational shafts, these sources do not provide inertia inherently, nor substantial amounts of short-circuit currents. However, stable energy such as what can be stored in energy storage systems, although interfaced via inverters, can be controlled to respond to system disturbances in a manner that emulates inertial behavior. This paper focuses on the application of such energy storage systems to augment inertia in the island of Puerto Rico. To do so, a user defined inverter model that contains grid forming capabilities and fast frequency response is modeled and integrated into the real transmission system in power flow and dynamics software. Energy storage is then connected to two selected areas so that it not only provides frequency regulation to avoid widespread load shedding events, but also other tangible benefits. The simulated cases suggest that even relatively small energy storage systems can avert load shedding events if adequately placed in the transmission network.

Grid-forming inverters, IBR, Inertia↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

27 ARPA - Advanced Research Projects Agency-Energy↗

Extracting maximal frequency response potential in controllable loads

Methods and apparatus are disclosed for extracting maximal frequency response potential in controllable loads. In one example, a method includes assigning a fitness metric to at least one electrical device coupled to a power grid, assigning a frequency threshold based on the fitness metric, and transmitting the assigned frequency threshold to the at least one electrical device. The fitness metric can be based at least in part on an availability component and a quality component associated with the at least one device and the frequency threshold can cause the at least one electrical device to activate autonomously based on a frequency of the power grid.

Lian, Jianming↗

Sparse Control Synthesis for Uncertain Responsive Loads With Stochastic Stability Guarantees

In this report, recent studies have demonstrated the potential of flexible loads in providing frequency response services, predominantly due to their availability and cost-effectiveness. However, uncertainty and variability in various weather-related and end-use behavioral factors often impact the reliability of demand-side control performance. This work addresses this problem with the design of a demand-side control to achieve frequency response under load uncertainties. Our approach involves modeling the load uncertainties via stochastic processes that appear as both multiplicative and additive in the power system dynamics. Recently developed mean square exponential stability (MSES) results for continuous-time linear stochastic systems are applied to pose the control synthesis problem which results in an LMI-based optimization problem. Additional costs and constraints are added to the LMI-based controller synthesis to ensure MSES, improve closed-loop transient performance, maximize tolerable uncertainties, and promote sparsity in the controller. Additionally, the fundamental limitations between the tolerable uncertainties and control efforts while ensuring MSES are discussed. Further, the control synthesis problem for the case of the full-state measurement is generalized to the case of partial-state measurements. The proposed control synthesis is illustrated on an IEEE 39 bus system with rigorous studies to demonstrate the role of sparsity, closed-loop transient performance, tolerable uncertainties, and control efforts while ensuring MSES and achieving frequency response.

42 ENGINEERING↗

Characterizing patterns and variability of building electric load profiles in time and frequency domains

The rapid development of advanced metering infrastructure provides a new data source—building electrical load profiles with high temporal resolution. Electric load profile characterization can generate useful information to enhance building energy modeling and provide metrics to represent patterns and variability of load profiles. Such characterizations can be used to identify changes to building electricity demand due to operations or faulty equipment and controls. In this study, we proposed a two-path approach to analyze high temporal resolution building electrical load profiles: (1) time-domain analysis and (2) frequency-domain analysis. Furthermore, the commonly adopted time-domain analysis can extract and quantify the distribution of key parameters characterizing load shape such as peak-base load ratio and morning rise time, while a frequency-domain analysis can identify major periodic fluctuations and quantify load variability. We implemented and evaluated both paths using whole-year 15-minute interval smart meter data of 188 commercial office building in Northern California. The results from these two paths are consistent with each other and complementary to represent full dynamics of load profiles. The time- and frequency-domain analyses can be used to enhance building energy modeling by: (1) providing more realistic assumptions about building operation schedules, and (2) validating the simulated electric load profiles using the developed variability metrics against the real building load data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Intensive and extensive margins of the peak load: Measuring adaptation with mixed frequency panel data

In this work we investigate the response of daily electricity peak load to daily maximum temperatures across states in Europe and India. We propose a method that decomposes short- from medium/long-run effects, retains the high frequency nature of the load-weather covariation and treats economic growth as a modulating factor. By simultaneously exploiting variation in unexpected daily weather anomalies and decade-long climatic changes in each location we decompose transitory - intensive margin - adjustments from permanent - extensive margin - adjustments. We find that the shocks over the long-run differ substantially from the short-run dynamics. Furthermore, we find evidence that per capita income modulates the adjustments over the short- and long-run. We project that in response to climate change around 2050 the peak load may increase by up to 20%-30% in Southern Europe and in several states in India, depending on the degree of warming and the evolution of socio-economic conditions. Even with a limited scope to two world regions, we identify that the structure of the economy and differences in future income growth matter in shaping the adaptation to climate change. Our decomposition allows to identify how future weather anomalies can further amplify the relative increase associated to the shift in the climate norm. Assuming that the interannual variability of maximum temperatures follows the distribution observed in the past, we find a doubling of the impacts of climate change during the summer in Europe. Uncertainty around the distribution of future weather anomalies may lead to further unexpected peak load amplifications. Our results have important policy implications for power systems’ generation capacity, transmission and storage, as we show that the challenges to accommodate the peak load in days with extreme temperatures may substantially increase already around mid-century.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗