Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Planck intermediate results

We present the NPIPE processing pipeline, which produces calibrated frequency maps in temperature and polarization from data from the Planck Low Frequency Instrument (LFI) and High Frequency Instrument (HFI) using high-performance computers. NPIPE represents a natural evolution of previous Planck analysis efforts, and combines some of the most powerful features of the separate LFI and HFI analysis pipelines. For example, following the LFI 2018 processing procedure, NPIPE uses foreground polarization priors during the calibration stage in order to break scanning-induced degeneracies. Similarly, NPIPE employs the HFI 2018 time-domain processing methodology to correct for bandpass mismatch at all frequencies. In addition, NPIPE introduces several improvements, including, but not limited to: inclusion of the 8% of data collected during repointing manoeuvres; smoothing of the LFI reference load data streams; in-flight estimation of detector polarization parameters; and construction of maximally independent detector-set split maps. For component-separation purposes, important improvements include: maps that retain the CMB Solar dipole, allowing for high-precision relative calibration in higher-level analyses; well-defined single-detector maps, allowing for robust CO extraction; and HFI temperature maps between 217 and 857 GHz that are binned into 0'.9 pixels (Nside = 4096), ensuring that the full angular information in the data is represented in the maps even at the highest Planck resolutions. The net effect of these improvements is lower levels of noise and systematics in both frequency and component maps at essentially all angular scales, as well as notably improved internal consistency between the various frequency channels. Based on the NPIPE maps, we present the first estimate of the Solar dipole determined through component separation across all nine Planck frequencies. The amplitude is (3366.6 ± 2.7) μK, consistent with, albeit slightly higher than, earlier estimates. From the large-scale polarization data, we derive an updated estimate of the optical depth of reionization of τ = 0.051 ± 0.006, which appears robust with respect to data and sky cuts. There are 600 complete signal, noise and systematics simulations of the full-frequency and detector-set maps. As a Planck first, these simulations include full time-domain processing of the beam-convolved CMB anisotropies. The release of NPIPE maps and simulations is accompanied with a complete suite of raw and processed time-ordered data and the software, scripts, auxiliary data, and parameter files needed to improve further on the analysis and to run matching simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling of Inductive Constant Power Load for Electromagnetic-Transient Simulations-Part II

This paper improves the dynamic constant power (CP) load model that was published in Part I, which is appropriate for electromagnetic-transient (EMT). The improved model conserves all features of its predecessor. For instance, it maintains a fixed power consumption (both active and reactive parts) and a fixed power factor for loads that are predominantly inductive. Furthermore, as the proposed model is a time-dependent system, it is applicable to both sinusoidal and non-sinusoidal case studies. However, the previous model cannot be easily integrated with numeric solvers because it simulated load data over one cycle all together, not sequentially in a time-step manner, due to the limitation involved with the power factor. The improved version, on the contrary, allows the load to be simulated at every time step, which would facilitate its integration with numeric solvers. The model's validity is confirmed by comparing its response with data that is synthesized from constant impedance load, and the result is satisfactory.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Guide for Improved Resource Adequacy Assessments in Evolving Power Systems: Institutional and Technical Dimensions

This paper identifies and evaluates issues in traditional resource adequacy (RA) assessment practices, and how adjusting these practices may affect and depend on existing institutional arrangements for planning and procurement. The paper proposes a technical-institutional roadmap that would allow regulators in vertically-integrated jurisdictions and system planners and operators in restructured jurisdictions to revise RA practices across a range of components. First, we compile a critical review of current RA assessment practices based on (1) interviews with RA practitioners and (2) a review of recent technical literature. We find that (i) RA may need to expand beyond capacity adequacy to ensure energy adequacy – relevant for energy-limited resources such as storage – and potentially some form of ancillary service adequacy (e.g. enough ramping-up and ramping-down capability in the system); (ii) chronological hourly simulations for all hours in the year are the current best practice; (iii) metrics and models used do not reflect economic criteria in system operation and loss of load; and (iv) there is a need to improve representation of weather dependencies and weather data. Second, we review planning and RA reports for several private and public entities that plan generation and/or transmission infrastructure in the continental U.S. to look for existing practices involving resilience assessments. We find no systematic treatment of the costs of extreme weather and other hazards, the benefits of resilience, and resilience metrics in planning analyses and no systematic treatment of resilience metrics, methods, and outcomes for resource adequacy purposes. Third, we create a technical framework for probabilistic RA assessment and use it to study how key choices about how to model power system operations affect the values that are obtained for RA metrics. We find that (i) non-economic dispatch schemes that ignore economic objectives can lead to accurate RA assessments when coordinated with detailed operational strategies; (ii) multi-year data is critical to capture a wide variety of system conditions; (iii) not incorporating transmission limits into RA assessment could lead to substantial underestimation of traditional “expected value” RA metrics; and (iv) new RA metrics that capture event-specific shortfall characteristics should be used as supplements to traditional metrics. Finally, we examine RA assessments and use this information to propose a guide of evolving industry standards for resource adequacy assessments in resource planning and transmission planning. We report minimum, best, and frontier practices for temporal resolution of assessments, metrics and targets, weather data, load forecasting, characterization of variable renewable resources, characterization of transmission and market transactions, RA modeling and integration with planning processes, and capacity accreditation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Powered by dsgrid [Slides]

NREL's demand-side grid (dsgrid) toolkit harnesses decades of sector-specific energy modeling expertise to understand current and future U.S. electricity load for power systems analyses. The primary purpose of dsgrid is to create comprehensive electricity load data sets at high temporal, geographic, sectoral, and end-use resolution. These data sets enable detailed analyses of current patterns and future projections of end-use loads. This presentation will include NREL power grid researcher Elaine Hale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extrapolation of the Rainflow-Counted Load Ranges for Fatigue Assessment of the Wind Turbine's Blades

Wind turbine design standards recommend the use of statistical modeling coupled with extrapolation of the short-term load data to long-term periods for fatigue reliability assessment. However, statistical error and computational expense can limit the accuracy of such approaches. In the case of wind turbine blades, the errors are more significant because of the high material fatigue exponent that makes the damage estimations more sensitive to variations. In addition, due to different excitation sources, the flapwise load range histogram is not unimodal, and thus its statistical modeling is complex. In the present work, we provide three methods for statistical modeling of the flapwise bending moment ranges including a novel approach based on frequency-based separation of the modes. The first two methods are simplified approaches for modeling the most crucial load ranges using unimodal distributions and the third method involves multimodal distribution fitting. The research is based on 3600 10-minute aeroelastic simulations of DTU 10MW case study wind turbine from which a benchmark damage equivalent load (DEL) is calculated. The DEL calculated by each of the three proposed methods is compared to this reference. The results show that the conventional approach based on using 6 seeds as well as using mixture models fitted on the limited data lead to under-conservative results with errors up to 23%. On the other hand, the simplified unimodal approaches provided in this work can provide conservative estimations of the fatigue damage with mean values 5% and 12% higher than the benchmark. However, the variability of the DEL estimates is higher when using unimodal extrapolation of the load ranges, and the data can be conservative by 17.5%. The proposed unimodal fits suggested for modeling and extrapolation of the blade's load ranges provide less errors relatively and most importantly conservative DEL estimations while maintaining computational efficiency.

blade fatigue↗

Online learning of quadratic manifolds from streaming data for nonlinear dimensionality reduction and nonlinear model reduction

Here, this work introduces an online greedy method for constructing quadratic manifolds from streaming data, designed to enable in situ analysis of numerical simulation data on the Petabyte scale. Unlike traditional batch methods, which require all data to be available upfront and take multiple passes over the data, the proposed online greedy method incrementally updates quadratic manifolds in one pass as data points are received, eliminating the need for expensive disk input/output operations as well as storing and loading data points once they have been processed. A range of numerical examples demonstrate that the online greedy method learns accurate quadratic manifold embeddings while being capable of processing data that far exceed common disk input/output capabilities and volumes as well as main-memory sizes.

97 MATHEMATICS AND COMPUTING↗

CEC Quest: Long Duration Energy Storage Impact Analysis Tool

SAND2025-14389O CEC Quest is a Python tool with a user interface designed to analyze the greenhouse gas impacts of long-duration energy storage projects in California. The tool automates data collection from public sources and uses an Application Programming Interface (API) to enable users to download photovoltaic resource availability, marginal operating emissions rate, and utility rate data. It guides users in inputting parameters for a battery energy storage model and uploading site electrical load data, while also prompting for relevant analysis parameters like timestep and grid limits. CEC Quest performs monthly optimization of one year of data to assess impacts on the site’s electrical bill and the grid’s greenhouse gas emissions. Finally, it conducts a lifecycle analysis to evaluate changes over a defined quantification period, with results aggregated through automated report generation. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Rosewater, David [Sandia National Lab. (SNL-CA), L↗

Knowledge Oriented Graph Unified Transformer (KOGUT) v0.1

KOGUT — Knowledge Oriented Graph Unified Transformer KOGUT implements the Relational Graph Transformer (RelGT) architecture for knowledge graph link prediction in biological domains, with a primary focus on microbial growth media prediction. While the original RelGT (arXiv:2505.10960) targets relational tables, time series, and multi-table databases, KOGUT adapts this architecture for heterogeneous biological knowledge graphs, providing first-in-class AI predictive models for microbial cultivation. Key Adaptations Beyond Original RelGT: - Knowledge Graph Focus: Applied to biological KGs with semantic node types (taxa, chemicals, media, phenotypes, environments) versus generic relational database tables, trained on the KG-Microbe knowledge graph (1.3M entities, 2.9M edges, 24 relation types). - Multimodal Node Encoding: Integrates node labels, categories, descriptions, and synonyms from KG metadata through learned embedding layers—adapting relational column features to graph node attributes with textual semantics. - Extended K-Hop Subgraph Strategy: Optimized neighborhood sampling (3-hop default, configurable up to 200 nodes) tuned for sparse biological networks, building on the original local-global attention framework with biological relation preservation. - Biolink Predicate Preservation: Type-specific transformations for 24 biological edge semantics (occurs_in, consumes, produces, has_phenotype, subclass_of) beyond standard relational foreign keys, enabling multi-relation link prediction. - Inductive Learning Support: Enables zero-shot predictions for novel taxa through feature-based embeddings (temperature, oxygen requirements, gram stain, cell shape), extending the original transductive relational benchmark scope to uncultured microorganisms. CheapSOTA Performance Optimizations (This Distribution): - VQ-EMA Centroid Attention: Vector quantization with exponential moving average for improved global context modeling (+5-10% MRR improvement). - HDF5 Precomputed Data Loading: One-time preprocessing of k-hop subgraphs to eliminate redundant graph traversals (2-5× training speedup). - Distributed Data Parallel Training: Multi-GPU support for scaling to larger knowledge graphs (tested on 4× NVIDIA A100 GPUs at NERSC Perlmutter). - Mixed Precision Training: Automatic mixed precision (AMP) for memory efficiency and faster training. Advantages Over Standard Knowledge Graph Embedding Models: Combines RelGT's proven multi-element tokenization (features, type, hop, structure) with graph-native biological representations, enabling interpretable link prediction across heterogeneous entities that standard embedding models (TransE, RotatE, ComplEx) and table-based transformers cannot directly model. Achieves near-perfect performance on microbial growth media prediction (MRR: 0.9966, Precision@1: 0.9932, Hit@10: 1.0000) while maintaining explainability through attention-based reasoning over biological pathways. Training Data: - KG-Microbe merged knowledge graph: 1,379,337 nodes, 2,960,472 edges - 24 biological relation types including taxonomic hierarchies, metabolic interactions, phenotype associations, and environmental relationships - Primary prediction task: Growth media suitability for microbial taxa (biolink:occurs_in, 50K edges) - Multi-relation capability: Predicts links for any of the 24 relation types, including chemical consumption/production, phenotype associations, and taxonomic classification Citation: Original RelGT Architecture: Dwivedi et al., "Relational Graph Transformer", arXiv:2505.10960, 2025 KOGUT Implementation: Knowledge Oriented Graph Unified Transformer for Microbial Growth Media Prediction Developed at Lawrence Berkeley National Laboratory (LBNL) Trained on NERSC Perlmutter supercomputer

Joachimiak, Marcin [Lawrence Berkeley National Lab↗

Differentially Private K -Means Clustering Applied to Meter Data Analysis and Synthesis

The proliferation of smart meters has resulted in a large amount of data being generated. It is increasingly apparent that methods are required for allowing a variety of stakeholders to leverage the data in a manner that preserves the privacy of the consumers. The sector is scrambling to define policies, such as the so called ‘15/15 rule’, to respond to the need. However, the current policies fail to adequately guarantee privacy. Here, in this paper, we address the problem of allowing third parties to apply K-means clustering, obtaining customer labels and centroids for a set of load time series by applying the framework of differential privacy. We leverage the method to design an algorithm that generates differentially private synthetic load data consistent with the labeled data. We test our algorithm’s utility by answering summary statistics such as average daily load profiles for a 2-dimensional synthetic dataset and a real-world power load dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sustainable Campus with PEV and Microgrid

Market penetration of electric vehicles (EVs) is gaining momentum, as is the move towards increasingly distributed, clean and renewable electricity sources. EV charging shifts a significant portion of transportation energy use onto building electricity meters. Hence, integration strategies for energy-efficiency in buildings and transport sectors are of increasing importance. This paper focuses on a portion of that integration: the analysis of an optimal interaction of EVs with a building-serving transformer, and coupling it to a microgrid that includes PV, a fuel cell and a natural gas micro-turbine. The test-case is the Nanyang Technological University (NTU), Singapore campus. The system under study is the Laboratory of Clean Energy Research (LaCER) Lab that houses the award winning Microgrid Energy Management System (MG-EMS) project. The paper analyses three different case scenarios to estimate the number of EVs that can be supported by the building transformer serving LaCER. An approximation of the actual load data collected for the building into different time intervals is performed for a transformer loss of life (LOL) calculation. The additional EV loads that can be supported by the transformer with and without the microgrid are analyzed. The numbers of possible EVs that can be charged at any given time under the three scenarios are also determined. The possibility of using EV fleet at NTU campus to achieve demand response capability and intermittent PV output leveling through vehicle to grid (V2G) technology and building energy management systems is also explored.

Singh, Reshma↗

Error containment for enabling local checkpoint and recovery

Various embodiments include a parallel processing computer system that detects memory errors as a memory client loads data from memory and disables the memory client from storing data to memory, thereby reducing the likelihood that the memory error propagates to other memory clients. The memory client initiates a stall sequence, while other memory clients continue to execute instructions and the memory continues to service memory load and store operations. When a memory error is detected, a specific bit pattern is stored in conjunction with the data associated with the memory error. When the data is copied from one memory to another memory, the specific bit pattern is also copied, in order to identify the data as having a memory error.

Cherukuri, Naveen↗

Detection of significant antiviral drug effects on COVID-19 with reasonable sample sizes in randomized controlled trials: A modeling study

Development of an effective antiviral drug for Coronavirus Disease 2019 (COVID-19) is a global health priority. Although several candidate drugs have been identified through in vitro and in vivo models, consistent and compelling evidence from clinical studies is limited. The lack of evidence from clinical trials may stem in part from the imperfect design of the trials. We investigated how clinical trials for antivirals need to be designed, especially focusing on the sample size in randomized controlled trials. A modeling study was conducted to help understand the reasons behind inconsistent clinical trial findings and to design better clinical trials. We first analyzed longitudinal viral load data for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) without antiviral treatment by use of a within-host virus dynamics model. The fitted viral load was categorized into 3 different groups by a clustering approach. Comparison of the estimated parameters showed that the 3 distinct groups were characterized by different virus decay rates (p-value < 0.001). The mean decay rates were 1.17 d -1 (95% CI: 1.06 to 1.27 d -1 ), 0.777 d -1 (0.716 to 0.838 d -1 ), and 0.450 d -1 (0.378 to 0.522 d -1 ) for the 3 groups, respectively. Such heterogeneity in virus dynamics could be a confounding variable if it is associated with treatment allocation in compassionate use programs (i.e., observational studies). Subsequently, we mimicked randomized controlled trials of antivirals by simulation. An antiviral effect causing a 95% to 99% reduction in viral replication was added to the model. To be realistic, we assumed that randomization and treatment are initiated with some time lag after symptom onset. Using the duration of virus shedding as an outcome, the sample size to detect a statistically significant mean difference between the treatment and placebo groups (1:1 allocation) was 13,603 and 11,670 (when the antiviral effect was 95% and 99%, respectively) per group if all patients are enrolled regardless of timing of randomization. The sample size was reduced to 584 and 458 (when the antiviral effect was 95% and 99%, respectively) if only patients who are treated within 1 day of symptom onset are enrolled. We confirmed the sample size was similarly reduced when using cumulative viral load in log scale as an outcome. We used a conventional virus dynamics model, which may not fully reflect the detailed mechanisms of viral dynamics of SARS-CoV-2. The model needs to be calibrated in terms of both parameter settings and model structure, which would yield more reliable sample size calculation. In this study, we found that estimated association in observational studies can be biased due to large heterogeneity in viral dynamics among infected individuals, and statistically significant effect in randomized controlled trials may be difficult to be detected due to small sample size. The sample size can be dramatically reduced by recruiting patients immediately after developing symptoms. We believe this is the first study investigated the study design of clinical trials for antiviral treatment using the viral dynamics model.

60 APPLIED LIFE SCIENCES↗

WISP: Watching grid Infrastructure Stealthily through Proxies (Final Technical Report)

The complex interdependencies of cyber systems (sensors and communications), physical grids and associated electricity market operations make protecting electric power grids a significant challenge. The energy sector is constantly under new, targeted, advanced and dangerous cyber-attacks that have the potential to result in the loss of human life. These threats are further exacerbated by our need to modernize the grid. One focus of cyber security research in smart grids is the securing of the SCADA system through advanced intrusion detection systems (IDS) and bad data detection algorithms in state estimation. These methods either require full knowledge of the system topology and parameters or fail to understand the physical behaviors under attack. WISP (Watching grid Infrastructure Stealthily through Proxies) is designed to provide additional protection to the power grid using only publicly available data. In particular, WISP exploits the spatio-temporal nature of the real time locational marginal prices (LMPs), in conjunction with other information such as bids, weather, outages and load data to analyze anomalous power pricing behaviors and then correlate those observations to localize regions of interest and identify potential cyber events. WISP is non-intrusive as the tool is deployed as a service in the Cloud or on premise and provides reliable information to system operators for enhanced situational awareness, without impeding energy delivery functions. The WISP technology comprises three modules: the data-driven anomaly detection core, the vulnerability and risk analysis and the root cause analysis. The data-driven anomaly detection core performs the tasks of feature selection, anomaly detection and attack region localization. The vulnerability and risk analysis module provides system level information of the vulnerable variables and times, assisting the operators in selecting monitoring and protection nodes. The root cause analysis module takes the detection results and identifies potential operational conditions that contribute to the detected anomalies. In Phase I, we have demonstrated the feasibility and effectiveness of WISP. We developed a realistic electricity market simulator capable of generating normal and attack market data under various operational conditions. We developed a series of cyber-attack detection and analysis algorithms and evaluated them under multiple data sources. Finally, we integrated all modules into an end-to-end software, providing functions for data management, data analytics and visualization. Specifically, we have achieved: (i) real-time data acceptance from external utility interfaces with >99% acceptance rate; (ii) high performance anomaly detection algorithms with >98% detection accuracy and <0.1% false alarm rate; and (iii) ultra-low computing delay <50 milliseconds. Additionally, our team developed algorithms to identify the vulnerable variables in electricity market operations and root cause analysis functions to identify major contributors to the price spikes. These ancillary modules are necessary when deploying WISP in real world industry environment. In Phase II, we have demonstrated the effectiveness of WISP software on realistic largescale power systems. We performed red team testing for the Phase I WISP software and identified software vulnerabilities and implemented corresponding mitigation solutions. We adapted the electricity market simulator for the Texas synthetic 2000-bus system and generated datasets for the false data injection attacks. We created database and visualization interfaces for the Texas system and the ISO New England system. We performed software optimization in terms of operation efficiency, computing speed and detection accuracy. Finally, we tested the software on the Texas system and the ISO New England system and evaluated the detection performance. Overall, we achieved above 89% detection rate, below 3% false alarm rate and below 37 seconds of end-to-end detection delay.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BuildingsBench: A Benchmark for Universal Building Load Forecasting [SWR-23-51]

The residential and commercial building stock in the United States is responsible for a significant percentage of energy consumption and greenhouse gas emissions. Electrification of end-uses, as well as decarbonizing the electrical grid through renewable energy sources such as solar and wind, constitutes the pathway to zero-emission buildings. Forecasting day-ahead building energy consumption is an integral part of this solution. Currently, specialized forecasting models are hand-made for each individual building, which is time-consuming, expensive, and leads to duplicated efforts. BuildingsBench is a Python software framework for training and comparing generalized machine learning models for universal building load forecasting. This challenge tasks a single foundational model to generalize its forecasts for a wide variety of buildings, across geographic regions, building types, weather patterns, and more. This software provide code for pre-training such models and subsequently evaluating their performance on a suite of hundreds of diverse real and synthetic buildings. BuildingsBench is a platform for: - Large-scale pretraining with the synthetic Buildings-900K dataset for short-term load forecasting (STLF). Buildings-900K is statistically representative of the entire U.S. building stock and is extracted from the NREL End-Use Load Profiles database. - Benchmarking on two tasks evaluating generalization: zero-shot STLF and transfer learning for STLF. We provide an index-based PyTorch Dataset for large-scale pretraining, easy data loading for multiple real building energy consumption datasets as PyTorch Tensors or Pandas DataFrames, simple (persistence) to advanced (transformer) baselines, metrics management, and more.

Emami, Patrick↗

Phase 1: Duke Energy Zero Emission Resource Integration Study (ZERIS); Phase 2: Carbon-Free Resource Integration Study for Duke Energy (Final Report)

Phase 1: This statement of work makes up Phase 1 of a larger effort. During this Phase 1 effort, NREL will work with Duke Energy to analyze the impacts of integrating significant amounts of new solar power into the Duke Energy power system under a variety of different penetrations scenarios, with a maximum of ten (10) full scenarios examined. The existing fleet, particularly the nuclear generation, will be considered in the quantitative assessments and discussions. Duke Energy is looking to quantify how much solar generation its system can handle. NREL will work with Duke Energy to quantify solar potential, identify likely integration challenges and possible opportunities for wind, storage, demand side resources and other technologies. Phase 2: This Statement of Work consists of a follow-up effort (Phase 2) to a recently completed Phase 1 modeling effort. During Phase 2, NREL will work closely with Duke Energy to analyze the impacts of integrating significant amounts of variable generation resources (wind and solar) and storage into Duke Energy's system in the Carolinas. The existing fleet, particularly nuclear generation, will be considered in the quantitative assessment and discussions. This Statement of Work also includes an extension to Phase II of the Carbon-Free Resource Integration Study for Duke Energy. In this extension, NREL will work closely with Duke Energy to extend the production cost analysis developed in Phase II to 2018 weather and load data for Duke Energy's territory. This extension leverages the modeling tools and datasets developed as part of Phase II. The analysis will compare results from Phase II (using 2012 weather and load) with 2018 results to assess system operations with increased penetration of renewables and storage. Simplifying assumptions will be made for modeling Duke Energy's neighbors in the production cost model.

14 SOLAR ENERGY↗

TASTI-GRID: Improving Electric Grid Resilience across the State of Tennessee

Residential, industrial, and large load data center facility expansion have exacerbated management backlogs. Additionally, as newer technologies emerge in larger utility providers, a chasm between urban and rural resilience grows – creating segmentation across the state. With new development, industries, and large load additions to the electric grid across the Volunteer state, utilities must contend with these new connections, management backlogs, and technology gaps – while addressing an increase in major outages with more frequent extreme weather events, such as Hurricane Helene in 2024. This issues, in turn, have given way to greater vulnerabilities in adjacent infrastructure – including transportation and emergency management services, among others.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An ICA-Based HVAC Load Disaggregation Method Using Smart Meter Data

This paper presents an independent component analysis (ICA) based unsupervised-learning method for heat, ventilation, and air-conditioning (HVAC) load disaggregation using row-resolution (i.e., 15 minutes) smart meter data. We first demonstrate that the electricity consumption profiles on mild-temperature days can be used to approximate the base load on hot days. A residual load profile can then be calculated by subtracting the mild-day load profile from the hot-day load profile. The residual load profiles are processed using ICA for HVAC load extraction. An optimization-based algorithm is proposed for post-adjustment of the ICA results, considering two bounding factors for enhancing the robustness of the ICA algorithm. First, we use the hourly HVAC energy bounds computed from the relationship between HVAC load and temperature to remove unrealistic HVAC load spikes. Second, we exploit the dependency between the daily nocturnal and diurnal loads extracted from historical meter data to smooth the base load profile. Pecan Street data with sub-metered HVAC data were used to test and verify the proposed methods. Simulation results demonstrated that the proposed method is computationally efficient and robust across multiple customers.

Kim, Hyeonjin↗

A Fast Dynamic Internal Predictive Power Scheduling Approach for Power Management in Microgrids: Preprint

This paper presents a Dynamic Internal Predictive Power Scheduling (DIPPS) approach for optimizing power management in microgrids, particularly focusing on external power exchanges among diverse prosumers. DIPPS utilizes a dynamic objective function with a time-varying binary parameter to control the timing of power transfers to the external grid, facilitated by efficient usage of energy storage for surplus renewable power. The microgrid power scheduling problem is modeled as a mixed-integer nonlinear programming (MINLP-PS) and subsequently transformed into a mixed-integer linear programming (MILPPS) optimization through McCormick's relaxation to reduce computational complexity. A predictive window window with 6 data points is solved at an average of 0.92s, a 97.6% improvement over the 38.27s required for the MINLP-PS formulation, implying the numerical feasibility of the DIPPS approach for real-time implementation. Finally, the approach is validated against a static objective using real-world load data across three case studies with different time-varying parameters, demonstrating the ability of DIPPS to optimize power exchanges and efficiently utilize distributed resources while shifting the external power transfers to specified time durations.

24 POWER TRANSMISSION AND DISTRIBUTION↗