Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

datacenterCoolingModel

ExaDigiT is a framework for developing comprehensive digital twins of liquid-cooled supercomputers, which has three main modules: (1) a python-based Resource Allocator and Power Simulator (RAPS), (2) a Modelica-based Thermo-Fluidic cooling model, and (3) a C++-based augmented reality model built on Unreal Engine 5. The Modelica-based cooling model is primarily built-on the open-source Transient Simulation Framework of Reconfigurable Models (TRANSFORM) library and the open-source autocsm library. The library follows the templating architecture developed in the TRANSFORM and the autocsm libraries. This tool can be easily extended to model other Frontier-like liquid cooled supercomputers.

Kumar, Vineet [Oak Ridge National Laboratory (ORNL↗

Century: Zap Energy’s 100-kW-Scale Repetitive Sheared-Flow-Stabilized Z -Pinch System with Liquid Metal Cooling

Zap Energy is developing the sheared-flow-stabilized (SFS) Z-pinch concept for commercial applications. The SFS Z pinch relies on plasma self-organization, in the sense that plasma dynamics play a critical role in confinement. Using plasma axial current for confinement and compression eliminates the need for external confinement or heating technologies. This compact magnetic confinement technology could, in turn, provide the basis for a cost-effective deuterium-tritium fusion power plant. In addition to a robust experimental program pushing plasma performance towards breakeven conditions, Zap Energy has parallel programs developing power handling systems suitable for future power plants. Technologies under development include high average-power repetitive pulsed power, high duty-cycle cathodes, and liquid metal wall systems. Century is the name of Zap Energy’s first effort to integrate these three components into an operational system capable of firing non-reacting hydrogen SFS Z-pinch plasmas into a liquid-metal-lined container at sustained repetition rates on the order of 0.1 Hz. Here, the pulsed power driver and liquid metal heat exchanger are both designed to sustain input powers of 100 kW. Construction and initial operations with an interim ~10 kW liquid metal heat exchanger are described.

Century↗

Efficient Refrigerated Display Cases - Can They Flex Their Power? Preprint

Refrigerated display cases are widely-used, critical equipment in supermarkets for maintaining product safety and quality. Energy-efficient medium temperature liquid-cooled refrigerated display cases can save 25-70% of the total supermarket energy, according to manufacturers. Traditionally, cases operate by maintaining a temperature around a user-input setpoint that is dependent on the product in the case. Although cases are major electrical energy consumers, they are hardly ever considered for implementing load-flexibility strategies. With added load-flexibility capabilities, refrigerated display cases can shed (reduce), or shift (by adding and subsequently shedding) load. Supermarkets can reduce their energy costs and enhance electric grid integrity by implementing these smart load-flexibility control strategies. Advanced controls can also enable load-shifting to coincide with optimum periods of renewable energy generation. This will further improve operational costs and reduce greenhouse gas emissions without compromising food safety and quality. In this research, we have evaluated the energy savings of liquid-cooled medium temperature display cases and developed load flexibility strategies leveraging an advanced controls system, a variable speed compressor, and heat rejection via a water-cooled condenser. This study further assessed the impact of load flexibility strategies in a controlled environment chamber for a single refrigerated display case.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Advancing Sustainability in Data Centers: Evaluation of Hybrid Air/Liquid Cooling Schemes for IT Payload Using Sea Water

Abstract-The growth in cloud computing, Big Data, AI and high-performance computing (HPC) necessitate the deployment of additional data centers (DC's) with high energy demands. The unprecedented increase in the Thermal Design Power (TDP) of the computing chips will require innovative cooling techniques. Furthermore, DC's are increasingly limited in their ability to add powerful GPU servers by power capacity constraints. As cooling energy use accounts for up to 40% of DC energy consumption, creative cooling solutions are urgently needed to allow deployment of additional servers, enhance sustainability and increase energy efficiency of DC's. The information in this study is provided from Start Campus' Sines facility supported by Alfa Laval for the heat exchanger and CO 2 emission calculations. The study evaluates the performance and sustainability impact of various data center cooling strategies including an air-only deployment and a subsequent hybrid air/water cooling solution all utilizing sea water as the cooling source. Here we evaluate scenarios from 3 MW to 15+1 MW of IT load in 3 MW increments which correspond to the size of heat exchangers used in the Start Campus' modular system design. This study also evaluates the CO 2 emissions compared to a conventional chiller system for all the presented scenarios. Results indicate that the effective use of the sea water cooled system combined with liquid cooled systems improve the efficiency of the DC, plays a role in decreasing the CO 2 emissions and supports in achieving sustainability goals.

97 MATHEMATICS AND COMPUTING↗

Machine Learning Analysis of Temperature-Strain Relationships for Structural Health Monitoring of Pipes: Self-powered wireless sensor system for health monitoring of liquid-sodium cooled fast reactors

This report presents machine learning (ML) analysis of temperature-strain relationships for structural health monitoring of nuclear reactor stainless steel (SS) pipes with the strain gauge sensor directly printed on the pipe with a 3D conformal aerosol jet printer. We investigate correlations for two sensor pairs installed on the same SS304 pipe: commercial K-type thermocouple with a printed gold strain gauge (TC3-SG3), and commercial K-type thermocouple with commercial Kyowa strain gauge (TC0-SG0). The temperature ranges for the sensor pairs TC0-SG0 and TC3-SG3 are 20.00°C to 266.37°C and 39.95°C to 219.28°C respectively. ML algorithms in this study include Linear Regression (baseline method), Ridge Regression, Lasso Regression, and Gradient Boosting. Performance evaluation metrics include Root Mean Square Error (RMSE), Mean Square Error (MSE), Mean Absolute Error (MAE), R 2 Score, and Explained Variance. Using advanced feature engineering techniques, we extracted 27 temperature-based features and 30 strategic inclusion features. The best performance was obtained with the Gradient Boosting method, which achieves prediction accuracy of R 2 = 0.9999 and RMSE = 7.69 μStrain for TC0-SG0, and R 2 = 0.9998 and RMSE = 18.03 μStrain for TC3-SG3. While the temperature-strain correlations are weaker for the gauge directly printed on the pipe than for the commercial strain gauge, deployment-ready performance exceeding industry standards is achieved for both sensor pairs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Providing Thermal Stability for an Exascale Supercomputer: A Case Study of Frontier's Cooling System

High performance computing (HPC) systems frequently produce large dynamic power swings, even under typical operating conditions, that can present a significant challenge for their direct-liquid cooling systems. Further, the primary cooling loops that must remove this waste heat have response times measured in minutes while the underlying HPC component thermal stress is measured in seconds. The per-socket power demand for both compute processing units (CPUs) and graphic processing units ( GPUs) continues to increase with each successive generation while case temperatures are declining. New HPC systems are expected to exacerbate the challenge of these dynamic power swings and the impact on effective and timely cooling systems. This paper describes the cooling and controls system for Oak Ridge National Laboratory’s Frontier Supercomputer, the first sustained exascale system, as a case study for this situation. The cooling and control system for Frontier demonstrates specific success, but with a number of trade-offs and decisions that suggest further design and operating optimizations for the community at large to consider.

42 ENGINEERING↗

Thermal Management of Discretized Heaters Using CuW Microchannel Heat Sinks and FC3283

Single-phase cooling using microchannel heat sinks (MCHS) has become a popular approach for overcoming the thermal challenges associated with high-powered microelectronic devices. Thermal management is one of the largest barriers to higher power densities in electronics and frequently limits overall device performance. The implementation of forced convective cooling via single-phase liquid cooling in MCHS reduces the thermal resistance resulting in lower device temperatures at high-power conditions, which can decrease the package size and extend the lifespan of devices. The goal of the work described in this article was to investigate practical cooling solutions for laser diode bars. This study examined the effectiveness of a copper tungsten (CuW) microchannel heat sink paired with a dielectric coolant (FC3283) for dissipating both discrete and uniform heat fluxes up to 600 W/cm2 across a 0.25-cm2 surface area through a numerical and experimental study. CuW was chosen as the MCHS material because it is thermal expansion matched to GaAs, which is a common laser diode substrate. FC3283 serves as a dielectric coolant that is compatible with power electronics cooling. The microchannels utilized in this work were approximately $365$ $μ$ m deep and $100$ $μ$ m wide resulting in a hydraulic diameter of $160$ $μ$ m. The study investigated the cooling performance across a variety of applied power loads and flow rates to determine optimal effectiveness. The resulting thermal resistance ranged from 0.15 cm2 K/W at the highest flow rate to 0.26 cm2 K/W at the lowest flow rate. Further, the resulting thermal performance from this study demonstrates the importance of considering discrete heat sources separately from uniform heat sources and proved that the unique combination of CuW microchannels with FC3283 can be a promising cooling option toward future advancements of laser diode bars and other high-power microelectronics.

42 ENGINEERING↗

Review of Tools for Modeling Core Radial Expansion in Liquid Metal-Cooled Fast Reactors

Core radial expansion in liquid-metal cooled fast reactor systems is a well-known phenomenon that produces strong reactivity feedback effects. It is crucial from a safety standpoint to design a reactor with the proper core restraint system to guide expansion of the fuel assemblies into a formation that produces negative reactivity feedback in accident conditions. However, the modeling of core radial expansion and its associated reactivity feedback is extremely challenging. Liquid metal-cooled fast reactor designers (both industry and commercial) have pointed to improved modeling of core radial expansion as a key modeling challenge for these types of reactors. The Department of Energy Nuclear Energy Advanced Modeling and Simulation (DOE-NEAMS) program has an important role to play in helping to develop a robust, predictive tool for this phenomenon. A literature review has been performed to identify current simulation capabilities applicable to the prediction of core radial expansion in liquid metal-cooled fast reactors and the resultant reactivity feedback effects. An overview as well as a detailed description of the multi-physics phenomena underlying core radial expansion is given in the first two chapters. The objective of this report is to identify existing software that has been or could be applied to the core radial expansion problem, and then to identify possible paths to develop a robust, coupled Multiphysics tool for advanced analysis, in which all three physics (radiation transport, structural mechanics, thermal fluids) are taken into account considering feedback effects from each physics to the other. Several computer codes and workflows have been developed in the United States and abroad to perform individual aspects of radial expansion calculations or to perform loosely coupled analysis. No code system currently exists which tightly and robustly couples the neutronics, thermal hydraulics, and thermal mechanical physics with enough detail to fully resolve the complex core radial expansion reactivity feedback effects. The future availability of such a code system is of vital importance to fully understanding the reactivity feedback effects that occur due to radial expansion, and consequently to optimizing the design of the core restraint system. A potential code development path forward using MOOSE-based tools is suggested in order to leverage the natural tight coupling and robustness of MOOSE-based applications. Additionally, potential gaps for modeling and common assumptions are listed which require further investigation to ensure accuracy for prediction of deformations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Control rod modeling in liquid metal-cooled fast reactors

Control rod modeling in Liquid Metal-cooled Fast Reactors (LMFRs) is important for an accurate simulation, especially in depletion calculations. Recently, control rod search and cusping models have been added to the LUPINE multiphysics fast reactor simulator. LUPINE stands for the 'LMFR Utility for Physics Informed Nuclear Engineering' and is currently being developed at North Carolina State University. LUPINE models the coupled multiphysics effects in LMFRs, including neutronics, thermal hydraulics, thermal expansion, and depletion. The control rod search has been implemented using a Newton-secant search in an inexact-Newton iteration and the cusping model uses a polynomial technique to correct for control rod cusping. The control rod cusping and search models were demonstrated by modeling the Advanced Burner Reactor (ABR) MET-1000 Sodium-cooled Fast Reactor (SFR) and a long-life Lead-cooled Fast Reactor (LFR) based on a Westinghouse Electric Company, LLC (WEC) design. A differential control rod worth curve was calculated for both reactor models to demonstrate the control rod cusping model. The SFR and LFR models were used to demonstrate the importance of modeling control rod movement during depletion calculations and the adverse effect of control rods on cycle length is demonstrated. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Long Term Per-Component Power and Thermal Measurements of the OLCF Summit System

As we move into the exascale era, the power and energy footprints of high-performance computing (HPC) systems have grown significantly larger. Due to the harsh power and thermal conditions the system, components are exposed to extreme operating conditions. Operation of such modern HPC systems requires deep insights into long term system behavior to maintain its efficiency as well as its longevity. To help the HPC community to gain such insights, we provide a dataset that records the long-term power and thermal behavior of the 200PF pre-exascale supercomputer at the Oak Ridge Leadership Computing Facility (OLCF), Summit. This system is an IBM AC922 based system that has 9,252 IBM Power9 CPUs and 27,756 Nvidia V100 GPUs and can consume up to 13MW power at peak. Heat removal is performed using medium temperature direct liquid cooling and rear-door heat exchanger based secondary cooling loop. Originally extracted from a high-resolution (1Hz) per-component (GPUs, CPUs) measurements from the system, we primarily provide a dataset that has 10-second and 1-minute mean power and thermal measurements selected from five month-long segments over the course of 2020 (January and August), 2021 (February and August), and 2022 (January). For convenience, we also provide various sub datasets randomly sampled from the time and space (hosts) of the cluster. Further details and example code for analysis can be found in the following GitHub repository: https://github.com/at-aaims/summit_power_and_thermal_data

97 MATHEMATICS AND COMPUTING↗

Comparative Analysis of Direct and Indirect Cooling of Wide-Bandgap Power Modules and Performance Enhancement of Jet Impingement-Based Direct Substrate Cooling

With the development of high-power and high-torque machines, requirements for high-power density electronics are increasing. Thermal management of such systems requires high heat extraction. Conventional air cooling based heat sinks and cold plate based liquid cooling have their own benefits for various applications but has limitations for high power density applications. The current study explores a jet impingement based direct substrate cooling system that was implemented for a SiC based direct bonded Cu substrate for various power losses. Numerical comparison between jet impingement cooling and conventional horizontal/indirect cooling (pin fin heat sink and genetic algorithm-optimized heat sink) showed that the area weighted average of the heat transfer coefficient (HTC) is high for both horizontal cooling designs, and the local HTC is higher for jet impingement. Design iterations were undertaken to resolve the bottleneck of this cooling system. Increasing the number of nozzles helped to cover more area at the direct bonded Cu bottom plate, which drops the chip temperature considerably. With a constant flow rate, increasing the number of nozzles would decrease local jet velocity, which reduces the heat extraction by jet impingement. This issue can be addressed by reducing the diameter of nozzle but doing so results in a high pressure drop where the design constraint is 2 psi. A flared nozzle design is proposed, which has a higher spreading angle of the jet that increases the flow coverage and reduces the pressure drop of the coolant loop.

Barua, Himel↗

Thermal Analysis of Liquid and Air Cooling of High-Power-Density Integrated Motor Drives

Thermal management is a crucial aspect in the design of motor and drive systems. This paper introduces a coordinated cooling approach utilizing both liquid and air to enhance the integrated motor drive's power density. The proposed solution incorporates a shared water jacket to cool both the machine and power electronics, combined with forced air ventilation for the end windings and rotor. This approach is structurally simpler, less expensive, and more effective than conventional non-interacting cooling schemes. The paper addresses the modeling of key thermal features and nonlinearities including material anisotropy, contact thermal resistance, and uneven winding loss distributions. In addition, this study utilizes a more detailed model of the loss distribution among the winding turns in each slot that delivers a higher level of accuracy. Finite Element Analysis (FEA) results demonstrate the effectiveness of the integrated cooling system for efficiently cooling the designed integrated motor drive system.

42 ENGINEERING↗

Economic assessment of a multistage surface-heated vacuum membrane distillation process for the treatment of hypersaline produced water

Here, the treatment and disposal of hypersaline produced water remains a challenge, particularly for oil and gas producers in the Permian basin where production wells generate significant amounts of wastewater, and the traditional method of injecting wastewater into disposal wells is coming under increasing scrutiny. Here we investigate the viability of using solar energy to power a multi-stage, surface heated, vacuum membrane distillation (SHVMD) with energy recovery to treat hypersaline produced wastewater from Midland, Texas. Membrane distillation is a process that can desalinate waters with high total dissolved solids concentration, and when incorporated into a system with surface heating and energy recovery can achieve high water recovery rates. Model results show that a 6-stage SHVMD system with a 54.4 % water recovery rate and a gained output ratio (GOR) of 3.28 has the potential to be economically viable when used to treat hypersaline produced water in the Permian basin. Assuming energy costs of $\$0.03$/kWh thermal and $\$0.12$kWh electric , we estimate a project net present value (NPV) of $\$225,525$ and an internal rate of return (IRR) of 13.5 % when an air cooled condensor is used to cool the distillate and a NPV of $\$570,791$ and IRR of 24.52 % when a liquid coooling source is available.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Thermo-Fluid Modeling Framework for Supercomputing Digital Twins: Part 2, Automated Cooling Models

The development of digital twins for the purpose of improving the energy efficiency of supercomputing facilities is a non-trivial endeavor that is complicated by the difficulty of creating physics-based thermo-fluid cooling system models (CSMs). Within ExaDigit---an open-source framework for liquid-cooled supercomputing digital twins---a thermo-fluid modeling framework is being developed. This effort has been segmented into two with two companion papers describing each portion of the overall effort. Part 1 focuses on the development of a cooling system library in Dymola for the Frontier supercomputer at Oak Ridge National Laboratory {\cite{Kumar2024}. Part 2, this paper, describes an effort to create a template-based auto-generation methodology for CSMs, called \textit{AutoCSM}. In this paper, an overview of the initial AutoCSM architecture and workflow is provided, along with a practical example using the Oak Ridge Leadership Computing Facility's (OLCF) Frontier supercomputer CSM. AutoCSM will (1) improve ExaDigiT's user accessibility by providing a flexible workflow for modularizing the creation of the CSM system and control logic, (2) decrease the development time of CSMs, and (3) standardize the method for incorporating CSMs into the ExaDigiT framework.

Greenwood, Scott↗

Dielectric Fluids for the Direct Forced Convection Cooling of Power Electronics

The future of electrification of vehicles and other systems will require the creation of high-power density power electronics with low junction-to-fluid thermal resistance cooling solutions. One way to create this solution is to move high-heat-flux liquid cooling (single- or two-phase) as close to the power electronics components as possible. One novel approach involves submersion in dielectric fluids as the cooling solution. We first provide the range of fluid properties and develop a figure of merit (FOM) to aid in dielectric fluid selection. Next, we perform computational fluid dynamics/heat transfer (CFD/HT) modeling using single-phase cooling (submerged jet impingement on an enhanced surface) to validate the dielectric fluid FOM. Results of the study show that the developed FOM is a good representation of the performance of the fluids when compared to the results of the CFD/HT analysis. Both FOM and the CFD/HT analysis show that based on pure thermohydraulic considerations, several commercially available fluids present higher performance, on the order of 5% of water. Finally, the FOM can be used to quickly assess the thermohydraulic performance of a dielectric fluid, as well as the secondary application-specific properties such as boiling point, saturation pressure, flash point, and global warming potential, thereby allowing for fluid candidates to be readily compared.

computational fluid dynamics↗

Analysis of power conversion technology options for a self-powered furnace

A self-powered furnace is defined as one that imports no electricity: a power cycle integrated into the furnace generates all the electrical power needed, and the heat rejected by the power cycle contributes to space heating. This paper presents criteria for selection of suitable power generation technology for such a furnace. A weighting system was presented to assign weight to each criterion based on its importance to the success of a self-powered furnace implementation. Power generation candidates were reviewed and scored based on the selection criteria. The top five candidates were analyzed to quantitatively compare the additional heat exchange requirements they impose on a baseline furnace. Air-cooled internal combustion engines and microturbine generators had negligible impact on the heat exchange requirement compared to a baseline furnace. Liquid-cooled internal combustion engines increased the heat exchange requirement by a factor of 1.5. Thermoelectric generators and thermophotovoltaic increased the heat exchange requirement by a factor of roughly 2.5. Organic Rankine cycle increased the heat exchange requirement by a factor of 5.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving Efficiency of DWPF Operations via Automating Process Calculations and Vitrifying High-Curie Feed- 24529

The Liquid Waste Organization (LWO) at the Savannah River Site (SRS) uses a “Power As One®” motto to process and dispose of radioactive waste. The Defense Waste and Processing Facility (DWPF) treats the high-level waste through a process of vitrification. The DWPF receives three incoming waste streams that are added to the Sludge Receipt and Adjustment Tank (SRAT): sludge, Monosodium Titanate/Sludge Solids (MST/SS), and Strip Effluent (SE). The liquid waste is mixed with pre-fabricated frit and treated with high temperatures in the melter prior to being poured into stainless steel canisters. The liquid cools to form solid glass within these canisters that are suitable for long-term storage and disposal. Savannah River Mission Completion (SRMC), the SRS liquid waste contractor for the U.S. Department of Energy, has implemented several facility improvements to further enhance the operations to support the Liquid Waste Operation (LWO) mission. Two of these operational enhancements include implementing the electronic Material Tracking Program Calculator (eMTPC)software and increasing the DWPF canister heat rate limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗