Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid chromatography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Detection of Anatoxins in Human Urine by Liquid Chromatography Triple Quadrupole Mass Spectrometry and ELISA

Harmful cyanobacterial blooms are becoming more common and persistent around the world. When in bloom, various cyanobacterial strains can produce anatoxins in high concentrations, which, unlike other cyanobacterial toxins, may be present in clear water. Potential human and animal exposures to anatoxins occur mainly through unintentional ingestion of contaminated algal mats and water. To address this public health threat, we developed and validated an LC-MS/MS method to detect anatoxins in human urine to confirm exposures. Pooled urine was fortified with anatoxin-a and dihydroanatoxin at concentrations from 10.0 to 500 ng/mL to create calibrators and quality control samples. Samples were diluted with isotopically labeled anatoxin and solvent prior to LC-MS/MS analysis. This method can accurately quantitate anatoxin-a with inter- and intraday accuracies ranging from 98.5 to 103% and relative standard deviations < 15%, which is within analytical guidelines for mass spectrometry methods. Additionally, this method qualitatively detects a common degradation product of anatoxin, dihydroanatoxin, above 10 ng/mL. We also evaluated a commercial anatoxin-a ELISA kit for potential diagnostic use; however, numerous false positives were detected from unexposed individual human urine samples. In conclusion, we have developed a method to detect anatoxins precisely and accurately in urine samples, addressing a public health area of concern, which can be applied to future exposure events.

urine↗

Use of Fisher's Ratio assisted multivariate curve resolution- alternating least squares for discovery-based analysis using ultrahigh pressure liquid chromatography-high resolution mass spectrometry

Non-targeted analysis of complex chemical mixtures can be difficult considering the convoluted nature of the matrix and the potential unknown chemical differences between samples or classes of samples. Ultrahigh pressure liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UHPLC-QTOF) is an ideal technique to probe chemical differences for a wide variety of samples. While UHPLC-QTOF can discover minute chemical differences down to low part per billion (ppb) concentrations with a high degree of confidence, the application of high-resolution mass spectrometry can yield massive amounts of information (∼ 10 gb per sample) that cannot be analyzed manually. Therefore, the application of chemometric techniques is mandatory for the interrogation of complex samples. Fisher's ratio (FR) assisted multivariate curve resolution-alternating least squares (MCR-ALS) was used to the discover and identify the chemical differences between two classes of materials: 1) a pond water matrix and 2) the matrix spiked with a pharmaceutical standard mix containing 17 compounds. Thirteen of the seventeen spiked compounds were discovered using FR analysis, and then five were successfully deconvoluted using MCR-ALS wherein the number of curves chosen were automatically determined using singular value decomposition (SVD). In conclusion, the use of an automated FR assisted MCR-ALS will aid in discovering trace levels of chemical components without the need for the researcher to provide potentially biased input which will aid in non-targeted workflow.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Statistically-driven Experimental Design to Improve Reference-free Quantification of Small Molecules by Liquid Chromatography-Mass Spectrometry

Non-targeted analysis of small molecules and metabolites in unknown, complex samples using liquid chromatography-tandem mass spectrometry remains challenging. One of the main bottlenecks is the extensive unannotated regions of metabolomics mass spectrometry data, resulting in knowledge gaps. Small molecule annotation in mass spectrometry data has conventionally relied on reference standards and libraries for compound identification and confirmation, which can constrain compound identification to those molecules already known, thus limiting the ability to discover new knowledge and new markers. Retention time prediction can facilitate and expedite unknown compound identification in non-targeted analysis of complex metabolomics samples. Additionally, accurate retention time predictions can also inform sample mixture design for LC-MS/MS analyses. However, current machine learning-based methods for retention time prediction are typically developed for specific chromatographic platforms and are not generalizable across scales. And while technologies and methods to improve reference-free metabolite identification for more comprehensive annotation of unknowns has received much attention, development of the same for quantitation without reference standards has been much more limited, despite its importance in toxicological, environmental, food safety, forensics, and clinical applications. We believe that a reference-free quantitation strategy that exploits mass spectrometry data already collected for reference-free identification can provide much more insight on unknowns, and move the metabolomics field for more complete unknowns characterization. As such, we pursue two efforts to improve upon current state-of-the-art methods in non-targeted analysis: (1) machine learning-based retention time prediction and (2) statistical design of experiments framework for reference-free quantitation. In this work, we develop and demonstrate (1) a generalizable retention time prediction capability across chromatographic conditions and scales, and (2) a statistical design-based framework for response factor contribution elucidation and reference-free quantitation. Evaluation of our retention time prediction model, PrediToR, showed approximately 24% improvement over current models, and we observed approximately 10X improvement in concentration estimation accuracy from our statistical design-based response factor model over a primarily ionization efficiency-based model. We expect that future efforts to improve upon these new capabilities will further advance non-targeted analysis of small molecules towards truly reference-free metabolomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development and implementation of high-throughput proteomic and metabolomics assays by using advanced chromatographic and mass spectrometric systems (CRADA Final Report)

The mission of this CRADA with Agilent was to couple powerful MS platforms (QQQ, IM-QTOFMS) with Agilent’s novel Ultra-High-Performance Liquid Chromatography (UHPLC) fast metabolomic workflows and perform ABF Machine Learning (ML) to generated datasets. Agilent transferred UHPLC methods to PNNL and LBNL and methods were implemented and demonstrated in both labs, achieving total acquisition times of < 10 min. Metabolites analyzed using Agilent’s shared methods included metabolites from central carbon metabolism, common across hosts, and metabolites unique to engineered strains. Standards were acquired in an UHPLC-Drift Tube Ion Mobility Mass Spectrometer (DTIMS) system for the first time within the context of ABF and methods were optimized based on Agilent’s protocols. Samples from ABF hosts Pseudomonas putida, Aspergillus pseudoterreus, Aspergillus niger and Rhodosporidium toruloides were analyzed using the UHPLC-DTIMS platform for a total of 276 runs. A data analysis workflow compatible with the Experimental Data Depot (EDD) and completely shareable was developed for the acquired UHPLC-DTIMS data. Samples were analyzed using a Data Independent Acquisition Approach (DIA), which for most of the standards provided more transitions therefore increasing detection confidence. Using the data acquired by PNNL, LBNL, and Agilent’s specifications from previous ML projects, SNL applied an ensemble ML strategy to pick the best performing model for automated LC-method selection. Finally, with the contribution of the participant labs and Agilent, SNL developed an Automated Method Selection (AMS) software tool to predict the best liquid chromatography method for analysis of any new molecules of interest. Samples with novel pathways and new metabolite targets of interest are generated at a high pace in the ABF. Overall, the project advanced rapid metabolomics by combining liquid chromatography, ion mobility spectrometry, and data-independent mass spectrometry with machine learning. This multidimensional approach uses retention time, collision cross-section, precursor mass, and fragment-ion information to distinguish chemically similar metabolites that can be difficult to resolve using conventional liquid- or gas-chromatography methods. The resulting workflow also provided automated metabolite-identification error estimates, addressing a recognized need for statistical confidence measures in metabolomics.

Petzold, Christopher [Lawrence Berkeley National L↗

Comparative study on the novel umami‐active peptides of the whole soybeans and the defatted soybeans fermented soy sauce

Abstract BACKGROUND Two kinds of soy sauce produced via fermentation of the whole soybeans and the defatted soybeans (soy sauce termed ‘SSS’ and ‘SSD’, respectively) were subjected to the treatment using aqueous ethanol solutions with high concentrations. Then tasty peptides were separated from SSS and SSD by sensory guided fractionation, using macroporous resin and reverse‐phase high‐performance liquid chromatography (RP‐HPLC), and identified by ultra‐performance liquid chromatography quadrupole time‐of‐flight tandem mass spectrometry (UPLC‐Q‐TOF‐MS/MS). Results The result showed that umami‐active fractions and ≤ 3 kDa peptides were mainly concentrated in the supernatants resulted from the treatment with 60% ethanol and the precipitates resulted from the treatment with 80% ethanol. The contents of ammonia nitrogen, non‐salt solids, bitter amino acids, amino acids in peptides and the proportion of ≤ 3 kDa peptides in SSS were higher than those in SSD. Sixteen and fourteen tasty peptides were separated from SSS and SSD, among them five dipeptides (γ‐Glu‐Glu, Glu‐Glu, γ‐Glu‐Cys, γ‐Glu‐Leu, Glu‐Leu and Ile‐Glu) with a glutamic acid residue were identified both in SSS and SSD, which have been reported as umami/kokumi‐active peptides in soy sauce. Several peptides identified from SSS (Thr‐Gly‐Cys, Gly‐Leu‐Glu, Val‐Glu‐Ala‐Leu and Gly‐Gly‐Gly‐Glu) and SSD (Asp‐Arg, Asp‐Ala‐Glu, Glu‐Val‐Cys and Gly‐Gly‐Gly‐Glu) are tasty and/or umami‐active peptides but have not been reported as tasty peptides in the past. Conclusion Most of the peptides separated from SSD and SSS could impart an umami‐enhancing effect on soy sauce, and the marginally more kokumi and bitterness hydrophobic peptides were found in SSS than SSD. © 2020 Society of Chemical Industry

Zhu, Xiping↗

Implementation and evaluation of multi-dual mode counter-current chromatography in the CUP Modeler software

Counter-current chromatography (CCC) is a separation technique that utilizes immiscible solvent pairs as stationary and mobile phases, which imparts numerous benefits compared to solid-liquid chromatography including the ability to treat either the more-dense or less-dense solvent layer as the mobile phase. Multi-dual mode (MDM) is a CCC elution mode capable of improving the separation of closely eluting compounds by alternating upper- and lower-layer solvent flows in opposing directions within the same separation. While some effort has been made to model MDM, implementation of these models in experimental design has yet to be widely adopted. Accordingly, we further developed our previously published cell utilized partitioning (CUP) model to include MDM predictions with CCC and packaged the full suite of CUP modeling capabilities into a user-friendly, open-source tool called the CUP Modeler. The mathematical model for MDM CCC was derived and validated with experimental separation of ethyl guaiacol (EG) and ethyl phenol (EP), two compounds that co-elute in our previously demonstrated reductive catalytic fractionation (RCF) lignin monomer isolation method. The developed MDM model provided insights into the effect of multiple operating parameters - including stationary phase retention, flow rate, column efficiency, feed concentration ratio, selectivity factor, and solute distribution ratios - on the separation yields, productivity, and purities. Our model agreed with prevailing understanding of MDM but also revealed new insights including that the ideal distribution ratios for co-eluting solutes to be separated by MDM is between 1.1 and 1.5, with the lower value ideally close to 1.25. Overall, this work provides fundamental insights for MDM process design and enables broader adoption of general liquid-liquid chromatography with a new, open-source user-friendly interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An efficient LC-MS method for isomer separation and detection of sugars, phosphorylated sugars, and organic acids

Abstract Assessing central carbon metabolism in plants can be challenging due to the dynamic range in pool sizes, with low levels of important phosphorylated sugars relative to more abundant sugars and organic acids. Here, we report a sensitive liquid chromatography–mass spectrometry method for analysing central metabolites on a hybrid column, where both anion-exchange and hydrophilic interaction chromatography (HILIC) ligands are embedded in the stationary phase. The liquid chromatography method was developed for enhanced selectivity of 27 central metabolites in a single run with sensitivity at femtomole levels observed for most phosphorylated sugars. The method resolved phosphorylated hexose, pentose, and triose isomers that are otherwise challenging. Compared with a standard HILIC approach, these metabolites had improved peak areas using our approach due to ion enhancement or low ion suppression in the biological sample matrix. The approach was applied to investigate metabolism in high lipid-producing tobacco leaves that exhibited increased levels of acetyl-CoA, a precursor for oil biosynthesis. The application of the method to isotopologue detection and quantification was considered through evaluating 13C-labeled seeds from Camelina sativa. The method provides a means to analyse intermediates more comprehensively in central metabolism of plant tissues.

Plant Sciences↗

Silver-mediated separations: A comprehensive review on advancements of argentation chromatography, facilitated transport membranes, and solid-phase extraction techniques and their applications

The use of silver(I) ions in chemical separations, also known as argentation separations, is a powerful approach for the selective separation and analysis of many natural and synthetic organic compounds. In this review, a comprehensive discussion of the most common argentation separation techniques, including argentation-liquid chromatography (Ag-LC), argentation-gas chromatography (Ag-GC), argentation-facilitated transport membranes (Ag-FTMs), and argentation-solid phase extraction (Ag-SPE) is provided. For each of these techniques, notable advancements, optimized separations, and innovative applications are discussed. The review begins with an explanation of the fundamental chemistry underlying argentation separations, mainly the reversible π-complexation between silver(I) ions and carbon-carbon double bonds. Within Ag-LC, the use of silver(I) ions in thin-layer chromatography, high-performance liquid chromatography, as well as preparative LC are explored. This discussion focuses on how silver(I) ions are employed in the stationary and mobile phase to separate unsaturated compounds. For Ag-GC and Ag-FTMs, different silver compounds and supporting media are discussed, often with relation to olefin-paraffin separations. Ag-SPE has been widely employed for the selective extraction of unsaturated compounds from complex matrices in sample preparation. This comprehensive review of Ag-LC, Ag-GC, Ag-FTMs, and Ag-SPE techniques emphasizes the immense potential of argentation separations in separations science and serves as a valuable resource for researchers seeking to learn, optimize, and utilize argentation separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Autosampler software

control software for an automated liquid chromatography sample injection and separation system. It is related to a PNNL invention report 31630-E, Method for direct delivering trace samples from smallsize wells to liquid chromatography and mass spectrometry. The main purpose of the control software is to enable automated sample injection from a nanowell device.

Liyu, Andrey↗

The Cell Utilized Partitioning Model as a Predictive Tool for Optimizing Counter-Current Chromatography Processes

Counter-current chromatography (CCC) is capable of unique elution modes that isolate analytes using the movement of the stationary phase in addition to moving the mobile phase. These modes include elution-extrusion CCC (EECCC) and dual-mode CCC (DM CCC) that are not possible in traditional solid-liquid chromatography systems. Although EECCC and DM CCC are widely used to recover highly retained components, to our knowledge, optimizing the elution process in these modes with predictive models has not been reported. To address this gap, we developed a predictive model for CCC dubbed the Cell Utilized Partitioning (CUP) model. The CUP model accurately predicts the effluents of multicomponent separations in EECCC and DM CCC modes when compared to experimental data. Furthermore, CUP model simulations were extended to investigate the influence of operating and intrinsic parameters on the yield and productivity, and to compare the separation performances of EECCC and DM CCC in various conditions. The results demonstrate that low distribution constants, usually a KD less than 1, and a selectivity > 1.3, under specific flowrate ranges, increase both productivity and yield. From these results, generalized optimization and scaleup guidelines are proposed that can apply to research settings and to industrial processes to maximize preparative CCC performance.

BIOMASS FUELS,INORGANIC, ORGANIC, PHYSICAL, AND AN↗

Ultrahigh performance LC/FT-MS non-targeted screening for biomass burning organic aerosol with MZmine2 and MFAssignR

In recent years, ultrahigh performance liquid chromatography Fourier transform mass spectrometry (LC/FT-MS) based non-targeted screening (NTS) methods have become increasingly popular for comprehensive analysis of complex organic mixtures. However, applying these methods for environmental complex mixture analysis is challenging due to the extreme complexity of natural samples and a lack of standard samples or surrogates for environmental complex mixtures. Furthermore, limited molecular markers in the databases and insufficient data processing software workflows make the application of these methods more challenging for environmental complex mixtures. In this work, we implement a new NTS data processing workflow to process data collected from ultrahigh performance liquid chromatography and Fourier transform Orbitrap Elite Mass Spectrometry (LC/FT-MS) by combining MZmine2 and MFAssignR, two opensource data processing tools and commercial Mesquite liquid smoke as a surrogate for biomass burning organic aerosol. MZmine2.53 data extraction followed MFAssignR molecular formula assignment offered noise free and highly accurate 1733 individual molecular formulas presented in liquid smoke with 4906 molecular species, including isomers. The results of this new approach were consistent with the results of direct infusion FT-MS analysis confirming its reliability. Over 90% of the molecular formulas presented in mesquite liquid smoke were matched with the molecular formulas of ambient biomass burning organic aerosol. This suggests the potential use of commercial liquid smoke as a surrogate for biomass burning organic aerosol research. Furthermore, the presented method significantly improves the identification of the molecular composition of biomass burning organic aerosol by successfully addressing some of the limitations related to the data analysis and giving a semi quantitative insight into the analysis.

54 ENVIRONMENTAL SCIENCES↗

Development of a Universal Second-Tier Newborn Screening LC–MS/MS Method for Amino Acids, Lysophosphatidylcholines, and Organic Acids

First-tier MS-based newborn screening by flow injection analysis can have high presumptive positive rates, often due to isomeric/isobaric compounds or poor biomarker specificity. These presumptive positive samples can be analyzed by second-tier screening assays employing separations such as liquid chromatography–mass spectrometry (LC–MS/MS), which increases test specificity and drastically reduces false positive referrals. The ability to screen for multiple disorders in a single multiplexed test simplifies workflows and maximizes public health laboratories’ resources. In this study, we developed and validated a highly multiplexed second-tier method for dried blood spots using a hydrophilic interaction liquid chromatography (HILIC) column coupled to an MS/MS system. The LC–MS/MS method was capable of simultaneously detecting second-tier biomarkers for maple syrup urine disease, homocystinuria, methylmalonic acidemia, propionic acidemia, glutaric acidemia type 1, glutaric acidemia type 2, guanidinoacetate methyltransferase deficiency, short-chain acyl-CoA dehydrogenase deficiency, adrenoleukodystrophy, and Pompe disease.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

metabCombiner 2.0: Disparate Multi-Dataset Feature Alignment for LC-MS Metabolomics

Liquid chromatography–high-resolution mass spectrometry (LC-HRMS), as applied to untargeted metabolomics, enables the simultaneous detection of thousands of small molecules, generating complex datasets. Alignment is a crucial step in data processing pipelines, whereby LC-MS features derived from common ions are assembled into a unified matrix amenable to further analysis. Variability in the analytical factors that influence liquid chromatography separations complicates data alignment. This is prominent when aligning data acquired in different laboratories, generated using non-identical instruments, or between batches from large-scale studies. Previously, we developed metabCombiner for aligning disparately acquired LC-MS metabolomics datasets. Here, we report significant upgrades to metabCombiner that enable the stepwise alignment of multiple untargeted LC-MS metabolomics datasets, facilitating inter-laboratory reproducibility studies. To accomplish this, a “primary” feature list is used as a template for matching compounds in “target” feature lists. We demonstrate this workflow by aligning four lipidomics datasets from core laboratories generated using each institution’s in-house LC-MS instrumentation and methods. We also introduce batchCombine, an application of the metabCombiner framework for aligning experiments composed of multiple batches. metabCombiner is available as an R package on Github and Bioconductor, along with a new online version implemented as an R Shiny App.

97 MATHEMATICS AND COMPUTING↗

Direct determination of cellulosic glucan content in starch-containing samples

A simple and highly selective analytical procedure is presented for the determination of cellulosic glucan content in samples that contain both cellulose and starch. This method eliminates the unacceptably large compounding errors of current two-measurement methods. If both starch and cellulose are present before analytical hydrolysis, both will be hydrolyzed to glucose causing bias and inaccuracy in the method. To prevent this interference, the removal of starch prior to cellulosic quantification is crucial. The method presented here is a concise in-series procedure with minimal measurements, eliminating large compounding errors. Sample preparation consists of a starch extraction employing enzymatic hydrolysis followed by a simple filtration and wash. The samples are then subjected to a two-stage acid hydrolysis. The concentration of glucose is determined by ion exchange high-performance liquid chromatography with a Pb 2+ column and a refractive index detector. The cellulosic glucan content is calculated based on the initial dry weight of the starting material. Data for the native biomass materials studied show excellent reproducibility, with coefficients of variance of 3.0% or less associated with the method. This selectivity for cellulosic glucan by the procedure was validated with several analytical techniques such as liquid chromatography coupled with mass spectrometry (LC–MS), Raman spectroscopy, and nuclear magnetic resonance.

09 BIOMASS FUELS↗

Novel insight into the kinetics of amide bond glycolysis for nylon-6 depolymerization

Chemical recycling of nylon-6 to short-chain oligomers and monomer ε-caprolactam via catalytic glycolysis is a potential solution for plastic waste remediation. Here, in this work, the kinetics of amide bond glycolysis (with ethylene glycol) in nylon-6 and the model compound N-phenethyl-3-phenylpropanamide (M1) were evaluated at 473 K in the presence of the cyclic amidine catalyst 1,5,7-triazabicyclo[4.4.0]dec-5-ene. Rates of polymer glycolysis were determined by the time-dependent shift in molecular weight distribution, whereas rates of M1 glycolysis were determined using liquid chromatography. The similarity of the first-order rate constants for glycolysis of nylon-6 and M1 at 473 K with 0.03 M amidine catalyst (5 mol% relative to amide bonds), 1.22 × 10 −5 s −1 and 2.18 × 10 −5 s −1 , respectively, confirmed the suitability of M1 as a model compound for nylon-6 glycolysis. Similar rates of glycolysis in the presence of other cyclic amidine catalysts as well as sodium methoxide revealed little influence of base strength. Glycolysis rates were unexpectedly non-linear in catalyst loading and deactivation occurred with long reaction times, presumably by non-selective decomposition of products as detected by liquid chromatography.

Depolymerization rate and rate constant↗

NIR Dataset and Models (Near-Infrared Spectroscopy Calibration Dataset for Butanediol Fermentation and Multivariate Calibration Models) [SWR-22-60]

2,3-butanediol (2,3-BDO) is an economically important platform chemical that can be used in a variety of chemical feedstocks, liquid fuels, and biosynthetic building blocks. While 2,3-BDO can be efficiently produced by fermentation, the fermentation requires continuous monitoring and control to maximize 2,3-BDO yields and minimize inhibitory coproducts. Because of the time required for sampling and at-line measurement of fermentation samples with high pressure liquid chromatography (HPLC), the ability for operators to perform real-time modification to fermentation conditions is limited. To overcome this challenge, researchers from the National Renewable Energy Laboratory (NREL) have developed a calibration model which can predict the concentration of several analytes in real-time using near-infrared (NIR) spectra of the filtered fermentation broth. While significantly reducing the need for off-line sampling, NREL expects this technology to play a critical role in maximizing 2,3-BDO production. 2,3-butanediol (2,3-BDO) is a useful chemical platform that can be used to create a variety of products. For instance, 2,3-BDO can be (1) dehydrated and converted into methyl ethyl ketone, a liquid fuel additive or (2) deoxydehydrated into 1,3-butadiene for synthetic rubber, which can also be oligomerized in high yields to gasoline, diesel, and jet fuel. In order to maximize 2,3-BDO production, frequent measurement of fermentation samples is needed, as small changes in oxygen concentration can drive the fermentation to undesired products. For example, oxygen-deficient conditions result in glycerol production, while excess oxygen concentrations result in acetoin production. This results in the need for measuring dissolved oxygen, glucose, and xylose concentrations in order to optimize the aeration rate of the fermentation. Traditional monitoring methods occurs off-line and can take up to 30 minutes per sample. With multiple fermenters and high-pressure liquid chromatography (HPLC) injectors, resulting in the need for multiple samples, the sampling process can take hours to complete. NREL’s calibration model can predict the glucose, xylose, 2,3-BDO, acetoin, and glycerol concentrations from NIR spectra of filtered fermentation liquor samples. Using a partial least-squares (PLS) calibration model, NREL’s model can monitor the concentration of these analytes during subsequent fermentations at bench- and pilot-scale, demonstrating the utility of NIR spectroscopy combined with chemometrics for real-time, at-line monitoring of 2,3-BDO fermentations.

Wolfrum, Edward↗

Agilent AgileBioFoundry CRADA (Final Report)

The mission of this CRADA with Agilent was to couple powerful MS platforms (QQQ, IM-QTOF-MS) with Agilent’s novel Ultra-High-Performance Liquid Chromatography (UHPLC) fast metabolomic workflows and perform ABF Machine Learning (ML) to generated datasets. Agilent transferred UHPLC methods to PNNL and LBNL and methods were implemented and demonstrated in both labs, achieving total acquisition times of < 10 min. Metabolites analyzed using Agilent’s shared methods included metabolites from central carbon metabolism, common across hosts, and metabolites unique to engineered strains. Standards were acquired in an UHPLC-Drift Tube Ion Mobility Mass Spectrometer (DTIMS) system for the first time within the context of ABF and methods were optimized based on Agilent’s protocols. Samples from ABF hosts Pseudomonas putida, Aspergillus pseudoterreus, Aspergillus niger and Rhodosporidium toruloides were analyzed using the UHPLC-DTIMS platform for a total of 276 runs. A data analysis workflow compatible with the Experimental Data Depot (EDD) and completely shareable was developed for the acquired UHPLC-DTIMS data. Samples were analyzed using a Data Independent Acquisition Approach (DIA), which for most of the standards provided more transitions therefore increasing detection confidence. Using the data acquired by PNNL, LBNL, and Agilent’s specifications from previous ML projects, SNL applied an ensemble ML strategy to pick the best performing model for automated LC-method selection. Finally, with the contribution of the participant labs and Agilent, SNL developed an Automated Method Selection (AMS) software tool to predict the best liquid chromatography method for analysis of any new molecules of interest. Samples with novel pathways and new metabolite targets of interest are generated at a high pace in the ABF. Therefore, our accomplishment in this CRADA improved the efficiency and accuracy of strain testing by developing and implementing fast analytical methods, robust processing tools, and software for predicting the best methods for UHPLC analysis.

97 MATHEMATICS AND COMPUTING↗