At least 55 records · Page 3

Dynamic Facade Dashboard v0.1.0

The dashboard is a useful tool for early-stage building design decision-making and communication, as it can help users quickly compare the energy and non-energy related performance of various automated, integrated facade systems using a library of pre-computed data. Users can explore the impacts of various design choices by selecting different facade glazing and shading systems, facade control strategies, and lighting control strategies across multiple climate zones. The dashboard instantly visualizes key metrics, including energy usage in HVAC and lighting, peak cooling and heating load, and daylight availability, allowing immediate trade-off analysis to optimize building efficiency and comfort.

Yu, Tammie [Lawrence Berkeley National Laboratory

Electrochemical growth of polyaniline films controlled with light

Plasmonic environment and light illumination can have significant impacts on electrochemical reactions. We explore the possibility to control electrochemical deposition of polyaniline films on gold substrates with light and study factors affecting film growth. The analysis of light-induced patterns in films exposed to laser light at different intensities and wavelengths reveals that the growth rate increases the light intensity at small intensities and then saturates with the further increase in laser light intensity. The wavelength of illumination does not significantly affect the results. The findings provide opportunities in fabrication of plasmonic structures with specific patterns of electrochromic polymer, which can operate as electrically tunable metasurfaces and plasmonic systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Installation package for integrated programmable electronic controller and hydronic subsystem - solar heating and cooling

A description is given of the Installation, Operation, and Maintenance Manual and information on the power panel and programmable microprocessor, a hydronic solar pump system and a hydronic heating hot water pumping system. These systems are integrated into various configurations for usages in solar energy management, control and monitoring, lighting control, data logging and other solar related applications.

Source record

Lighting considerations in controlled environments for nonphotosynthetic plant responses to blue and ultraviolet radiation

This essay will consider both physical and photobiological aspects of controlled environment lighting in the spectral region beginning in the blue and taken to the normal limit of the solar spectrum in the ultraviolet. The primary emphasis is directed to questions of plant response to sunlight. Measurement and computations used in radiation dosimetry in this part of the spectrum are also briefly treated. Because of interest in the ozone depletion problem, there has been some activity in plant UV-B research and there are several recent reviews available. Some aspects of growth chamber lighting as it relates to UV-B research were covered earlier. Apart from work related to the blue/UV-A receptor, less attention has been given to UV-A responses.

Caldwell, M. M.

Light Improves Alertness and Mood during the Sleep Inertial Period following Slow Wave Sleep

Introduction: Waking from sleep, especially slow wave sleep (SWS), is associated with reduced alertness known as sleep inertia. Light improves alertness during sleep deprivation and circadian misalignment. In this study, we assessed the efficacy of light to improve alertness and mood immediately after waking from SWS. Methods: Twelve participants kept a sleep schedule of 8.5 h for 5 nights and 5 h for one night prior to the overnight laboratory visit (confirmed by actigraphy). Participants went to bed at their scheduled habitual bedtime in the laboratory and were monitored by standard polysomnography. After at least 5 min of SWS, participants were awoken and exposed to either red ambient light (control) or blue-enriched bright light (light) for 1 h. During this time, participants completed a subjective scale of alertness (Karolinska Sleepiness Scale, KSS) and visual analogue scales (VAS) of mood at 2 min, 17 min, 32 min, and 47 min after waking. Following this sleep inertia measurement period, all lights were turned off and participants were allowed to return to sleep. They were then awoken again from their subsequent SWS period and exposed to the opposite condition (control or light). A linear mixed-effects model with fixed effects of condition, time, and condition*time and a random effect of participant was used to determine the impact of light across the testing period. An average of baseline responses (pre-sleep) was included as a covariate. Results: Compared to the control condition, participants exposed to bright blue-enriched light reported feeling more alert (KSS: F1,77=4.955, p=.029; VASalert: F1,77=8.226, p=.005), more cheerful (VAScheerful: F1,77=8.615, p=.004), less depressed (VASdepressed: F1,77=4.649, p=.034), and less lethargic (VASlethargic: F1,77=5.652, p=.020). Discussion: Exposure to blue-enriched bright light immediately after waking from SWS may help to improve subjective alertness and mood. Future analyses will explore whether these findings extend to effects on cognitive performance.

alertness

Analysis and Design of Phase Change Thermal Control for Light Emitting Diode (LED) Spacesuit Helmet Lights

LED Helmet Extravehicular Activity Helmet Interchangeable Portable (LEHIP) lights for the Extravehicular Mobility Unit (EMU) have been built and tested and are currently being used on the International Space Station. A design is presented of the passive thermal control system consisting of a chamber filled with aluminum foam and wax. A thermal math model of LEHIP was built and correlated by test to show that the thermal design maintains electronic components within hot and cold limits for a 7 hour spacewalk in the most extreme EVA average environments, and do not pose a hazard to the crew or to components of the EMU.

Bue, Grant C.

Overview of NASA research in fiber optics for aircraft controls

The challenge of those involved in aircraft control system hardware development is to accommodate an ever-increasing complexity in aircraft control, while limiting the size and weight of the components and improving system reliability. A technology that displays promise towards this end is fiber optics. The primary advantages of employing optical fibers, passive optical sensors and optically controlled actuators are weight/volume reduction, immunity from electromagnetic effects, high bandwidth capabilities and freedom from short circuits/sparking contacts. Since 1975, NASA Lewis has been performing in-house, contract and grant research in fiber optic sensors, high temperature electro-optic switches and fly-by-light control system architecture. Passive optical sensor development is an essential yet challenging area of work and has therefore received much attention during this period. A major effort to develop fly-by-light control system technology, known as the Fiber Optic Control System Integration (FOCSI) program, was initiated in 1985 as a cooperative effort between NASA and DOD. Phase 1 of FOCSI, completed in 1986, was aimed at the design of a fiber optic integrated propulsion/flight control system. Phase 2 will provide subcomponent and system development and system testing. In addition to a summary of the benefits of fiber optics, the FOCSI program, sensor advances, and future directions in the NASA Lewis program are discussed.

Seng, Gary T.

Landsat 9 Mission Update and Status

Landsat 9 is currently undergoing testing at the integrated observatory level in preparation for launch from Vandenberg Air Force Base in 2021. Landsat 9 will replace Landsat 7 in orbit, 8 days out of phase with Landsat 8. Landsat 9 is largely a copy of Landsat 8 in terms of instrumentation, with an Operational Land Imager (OLI), model #2 and a Thermal Infrared Sensor (TIRS), model #2. The TIRS-2 is more significantly changed from TIRS with increased redundancy, as well as changes to the telescope baffling to improve stray light control and a revised scene select mirror encoder mechanism. Data quality of the Landsat 9 instruments is comparable to, or better than the Landsat 8 ones, with an increase to 14 bits of data transmitted and more detailed pre-launch characterization for OLI-2, and with more detailed characterization of the TIRS-2 pre-launch, in addition to the improved stray light control. The performance of the two instruments is summarized and compared to that of the Landsat 8 instruments.

Brian Markham

Guaranteeing Pointing Performance of the SDO Sun-Pointing Controllers in Light of Nonlinear Effects

The Solar Dynamics Observatory (SDO) mission is the first Space Weather Research Network mission, part of NASA s Living With a Star program.1 This program seeks to understand the changing Sun and its effects on the Solar System, life, and society. To this end, the SDO spacecraft will carry three Sun-observing instruments to geosynchronous orbit: Helioseismic and Magnetic Imager (HMI), led by Stanford University; Atmospheric Imaging Assembly (AIA), led by Lockheed Martin Space and Astrophysics Laboratory; and Extreme Ultraviolet Variability Experiment (EVE), led by the University of Colorado. Links describing the instruments in detail may be found through the SDO web site.2 The basic mission goals are to observe the Sun for a very high percentage of the 5-year mission (10-year goal) with long stretches of uninterrupted observations and with constant, high-data-rate transmission to a dedicated ground station. These goals guided the design of the spacecraft bus that will carry and service the three-instrument payload. At the time of this publication, the SDO spacecraft bus is well into the integration and testing phase at the NASA Goddard Space Flight Center (GSFC). A three-axis stabilized attitude control system (ACS) is needed both to point at the Sun accurately and to keep the roll about the Sun vector correctly positioned. The ACS has four reaction wheel modes and 2 thruster actuated modes. More details about the ACS in general and the control modes in particular can be found in Refs. [3-6]. All four of SDO s wheel-actuated control modes involve Sun-pointing controllers, as might be expected from such a mission. Science mode, during which most science data is collected, uses specialized guide telescopes to point accurately at the Sun. Inertial mode has two sub-modes, one tracks a Sun-referenced target orientation, and another maintains an absolute (star-referenced) target orientation, that both employ a Kalman filter to process data from a digital Sun sensor and two star trackers. However, this paper is concerned only with the other two modes: Safe Hold (SH) and Sun Acquisition (SA).

Starin, Scott R.

Interior noise analysis and control for light aircraft

This paper describes experimental and analytical studies of the interior noise of twin-engine, propeller-driven, light aircraft. Experimental results indicate that interior noise levels due to propeller noise can be reduced by reduction of engine rpm at constant airspeed (about 3 dB), by synchronization of the twin engines/propellers (up to 12 dB), and by increasing the distances from propeller tip to fuselage. The analytical model described uses modal methods and incorporates the flat-sided geometrical and skin-stringer structural features of light aircraft. Initial results show good agreement with measured noise transmitted into a rectangular box through a flat panel.

Mixson, J. S.

Laboratory study of efficient add-on treatments for interior noise control in light aircraft

Experimental and theoretical studies of the transmission loss (TL) of 1.15 x 1.46 m flat stiffened-skin aluminum panels are described. Panel configurations included panels with no treatment and eight combinations of treatments consisting of a fiberglass-septum layer, a foam-foil damping material, and a plywood double wall trim panel. Measured TL of the untreated panel and the panel with a damping layer showed characteristics of the double mass law: at low frequencies the TL followed a mass law trend associated with the average mass of both skin and stiffness, while at higher frequencies the TL followed a mass law trend associated with skin mass only. A comparison of TL for panels treated with a damping layer, a fiberglass layer, or a trim panel showed that the effects of damping are frequency dependent with some performing better below 500 Hz and others performing better above 500 Hz. Treatment combinations showed that two treatments with the same mass could have TL values different by about 10 dB, while other combinations having weights different by a factor of two could have TL values within a few dB over most of the frequency range. The highest TL values (50 dB at 1000 Hz) were obtained with a treatment consisting of a fiberglass layer, a trim panel, and damping layers on both the stiffened panel and the trim panel.

Mixson, J. S.

TV Video-Level Controller

Constant output maintained, though luminance varies by 5 million to 1. Three means of normalizing video output utilized in video-level controller: iris adjustment, tube voltage adjustment, and automatic gain control. With aid of automatic light control and gain control, television camera accommodates maximum light level 5 million times greater than lowest light level, while outputting constant 3-V peak signal to processing circuitry.

Kravitz, M.

Energy saver for industrial lighting

Electronic controller switches lights on or off in response to amount of sunlight available. Is application in offices and industrial installations where electrical energy is wasted by using artificial light in sunlit areas. Device utilizes electronic monitor that varies artificial lighting according to amount of sunlight in given area.

Arline, J.

Rise and Shine: The Use of Polychromatic Short-Wavelength-Enriched Light to Mitigate Sleep Inertia at Night Following Awaking From Slow-Wave Sleep

Sleep inertia is the brief period of performance impairment and reduced alertness experienced after waking, especially from slow-wave sleep. We assessed the efficacy of polychromatic short-wavelength-enriched light to improve vigilant attention, alertness and mood immediately after waking from slow-wave sleep at night. Twelve participants (six female, 23.3 ± 4.2 years) maintained an actigraphy-confirmed sleep schedule of 8.5 hr for 5 nights, and 5 hr for 1 night prior to an overnight laboratory visit. In the laboratory, participants were awakened from slow-wave sleep, and immediately exposed to either dim, red ambient light (control) or polychromatic short-wavelength-enriched light (light) for 1 hr in a randomized crossover design. They completed a 5-min Psychomotor Vigilance Task, the Karolinska Sleepiness Scale, and Visual Analogue Scales of mood at 2, 17, 32 and 47 min after waking. Following this testing period, lights were turned off and participants returned to sleep. They were awakened from their subsequent slow-wave sleep period and received the opposite condition. Compared with the control condition, participants exposed to light had fewer Psychomotor Vigilance Task lapses (χ 2 [1] = 5.285, p = 0.022), reported feeling more alert (Karolinska Sleepiness Scale: F 1,77 = 4.955, p = 0.029; Visual Analogue Scale alert : F 1,77 = 8.226, p = 0.005), and reported improved mood (Visual Analogue Scale cheerful : F 1,77 = 8.615, p = 0.004). There was no significant difference in sleep-onset latency between conditions following the testing period (t 10 = 1.024, p = 0.330). Our results suggest that exposure to polychromatic short-wavelength-enriched light immediately after waking from slow-wave sleep at night may help improve vigilant attention, subjective alertness, and mood. Future studies should explore the potential mechanisms of this countermeasure and its efficacy in real-world environments.

alertness

Control apparatus for spectral energy source

Automatic light-controlling system for dc arc emission spectrographs controls the vaporization rate of the sample and stabilizes the dc arc. The output energy is regulated such that advantage can be taken of the highly sensitive dc arc source without sacrificing the desired precision.

Gordon, W. A.