Collimator irradiation studies in the Argonne Advanced Photon Source at energy densities expected in next-generation storage ring light sources
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Conventional thermionic microwave and radiofrequency (RF) guns can offer high average beam current, which is important for synchrotron light and terahertz (THz) radiation source facilities, as well as for industrial applications. For example, the Advanced Photon Source at Argonne National Laboratory is a national synchrotron radiation light source research facility that utilizes thermionic RF guns. Yet, these existing thermionic guns are bulky, difficult to handle and install, easily detuned, very sensitive to thermal expansion, and are due for a major upgrade and replacement. Here, we present the design of a new, more stable and reliable gun with optimized electromagnetic performance, improved thermal engineering and a more robust cathode mounting technique, which is a critical step to improve the performance of existing and future light sources, industrial accelerators, and electron beam-driven terahertz sources. We will also present a fabricated gun prototype and show results of high-power and beam tests.
Abstract Optical transmission and scattering spectroscopic microscopy at the visible and adjacent wavelengths denote one of the most informative and inclusive characterization methods in material research. Unfortunately, restricted by the diffraction limit of light, it cannot resolve the nanoscale variation in light absorption and scattering, diagnostics of the local inhomogeneity in material structure and properties. Moreover, a large quantity of nanomaterials has anisotropic optical properties that are appealing yet hard to characterize through conventional optical methods. There is an increasing demand to extend the optical hyperspectral imaging into the nanometer length scale. In this work, we report a super-resolution hyperspectral imaging technique that uses a nanoscale white light source generated by superfocusing the light from a tungsten-halogen lamp to simultaneously obtain optical transmission and scattering spectroscopic images. A 6-nm spatial resolution in the visible to near-infrared wavelength regime (415–980 nm) is demonstrated on an individual single-walled carbon nanotube (SW-CNT). Both the longitudinal and transverse optical electronic transitions are measured, and the SW-CNT chiral indices can be identified. The band structure modulation in a SW-CNT through strain engineering is mapped.
Devices, systems and methods for widefield three-dimensional (3D) microscopy with a quantum entanglement light source are described. An example method includes generating a first set of photons and a second set of photons, wherein each of the photons in the first set is quantum entangled with a corresponding photon in the second set, directing the second set of photons toward a sample and simultaneously directing the first set of photons toward a first two-dimensional (2D) detector, detecting, from the sample, a plurality of photons at a second 2D detector, analyzing detections from the first and second 2D detectors to determine coincidence information, and determining one or more characteristics associated with at least a three-dimensional (3D) section of the sample based on collective detections at the first and the second 2D detectors.
Free-electron-laser-based beamlines utilize fully coherent laser pulses with extremely narrow bandwidth allowing direct use of X-rays without monochromators. This could be very beneficial for all users of current and future fourth-generation diffraction-limited synchrotron light sources (DL-SLSs) who need narrowband full-coherence high-brightness X-ray pulses. Based on our previous finding, i.e. that separating the two stages of echo-enabled harmonic generation (EEHG) with a few extra bending-magnet sections provides an effective way to increase the momentum compaction of chicane 1, one can simultaneously achieve adequate prebunching at extremely high harmonics as well as keep the energy modulation to the ideal minimum. This could open the door for cascaded EEHG, toward fully coherent tender and hard X-ray wavelengths. Built on our compact design of a twin-pulse seeding electron beam with an adjustable delay and timing jitter at the level of a few femtoseconds, a cascaded EEHG can be implemented, which includes two EEHG beamlines, where the radiation pulse generated by the first beamline with harmonic $h$ 1 could be used as the input seed laser pulse to the second beamline with harmonic $h$ 2 . Hence, the second radiator could potentially reach very high harmonics [$h$ = $h$ 1 (20)$h$ 2 (25–100)] from 500 to 2000, corresponding to tender and hard X-ray wavelengths. It is demonstrated that the cascaded EEHG scheme is compatible with almost any current or planned fourth-generation DL-SLS, with significant benefits for space-limited storage rings in particular. The main advantage is that this scheme requires almost no change of the storage-ring lattice and is fully compatible with other beamlines. Current proposals for rings with much longer straight sections would add self-amplified spontaneous emission as another viable option for storage-ring-based free-electron lasers.
ALS-ENABLE is an integrated NIH P30 resource at the Advanced Light Source synchrotron at Lawrence Berkeley National Laboratory in Berkeley, California, USA. The resource provides a single portal to the combined mature structural biology technologies of macromolecular crystallography, small-angle X-ray scattering and X-ray footprinting mass spectrometry, and includes beamlines 2.0.1, 3.3.1, 4.2.2, 5.0.1, 5.0.2, 5.0.3, 8.2.1, 8.2.2, 8.3.1 and 12.3.1. This paper describes the organizational structure and the technologies of ALS-ENABLE. A case study showcasing the main technologies of the resource applied to the characterization of the SpyCatcher-SpyTag protein system is presented.
Quantum correlated states of light, such as squeezed states, are a fundamental resource for the development of quantum technologies, as they are needed for applications in quantum metrology, quantum computation, and quantum communications. It is thus critical to develop compact, efficient, and robust sources to generate such states. Here, we report on a compact, narrowband, fiber-coupled source of two-mode squeezed states of light at 795 nm based on four-wave mixing (FWM) in an 85 Rb atomic vapor. The source is designed in a small modular form factor, with two input fiber-coupled beams, the seed and pump beams required for the FWM, and two output fibers, one for each of the modes of the squeezed state. The system is optimized for low pump power (135 mW) to achieve a maximum intensity-difference squeezing of 4.4 dB after the output of fibers at an analysis frequency of 1 MHz. Furthermore, the narrowband nature of the source makes it ideal for atomic-based quantum sensing and quantum networking configurations that rely on atomic quantum memories. Such a source paves the way for a versatile and portable platform for applications in quantum information science.
High-resolution biomacromolecular structure determination is essential to better understand protein function and dynamics. Serial crystallography is an emerging structural biology technique which has fundamental limitations due to either sample volume requirements or immediate access to the competitive X-ray beamtime. Obtaining a high volume of well-diffracting, sufficient-size crystals while mitigating radiation damage remains a critical bottleneck of serial crystallography. As an alternative, we introduce the plate-reader module adapted for using a 72-well Terasaki plate for biomacromolecule structure determination at a convenience of a home X-ray source. We also present the first ambient temperature lysozyme structure determined at the Turkish light source (Turkish DeLight). The complete dataset was collected in 18.5 min with resolution extending to 2.39 Å and 100% completeness. Combined with our previous cryogenic structure (PDB ID: 7Y6A), the ambient temperature structure provides invaluable information about the structural dynamics of the lysozyme. Turkish DeLight provides robust and rapid ambient temperature biomacromolecular structure determination with limited radiation damage.
The beamline optics and endstations at branch B of the Versatile Soft X-ray (VerSoX) beamline B07 at Diamond Light Source are described. B07-B provides medium-flux X-rays in the range 45-2200 eV from a bending magnet source, giving access to local electronic structure for atoms of all elements from Li to Y. It has an endstation for high-throughput X-ray photoelectron spectroscopy (XPS) and near-edge X-ray absorption fine-structure (NEXAFS) measurements under ultrahigh-vacuum (UHV) conditions. B07-B has a second endstation dedicated to NEXAFS at pressures from UHV to ambient pressure (1 atm). The combination of these endstations permits studies of a wide range of interfaces and materials. The beamline and endstation designs are discussed in detail, as well as their performance and the commissioning process.
Radiation-based techniques for measuring electron source sizes are widely used as emittance diagnostics at existing synchrotron sources. Three of these techniques, namely, pinhole imaging, double-slit interferometry, and a K-edge filter-based beam position and size monitor system (ps-BPM), are evaluated for measuring source sizes at low-emittance storage rings. Each technique is reviewed with a detailed system description, design optimization, and practical considerations targeted for small source sizes. Pinhole imaging has the simplest setup and gives the beam profile in both transverse dimensions but with limited resolution. Double-slit interferometry has the highest resolution but with a limited detectable size range. The ps-BPM system shows reasonable resolution for monitoring small source sizes and divergence and can give real-time information of the source position and angle. New facilities may consider an integrated system that combines some or all of these techniques.
Serial data collection is a relatively new technique for synchrotron users. A user manual for fixed target data collection at I24, Diamond Light Source is presented with detailed step-by-step instructions, figures, and videos for smooth data collection.
Abstract The advent of low-emittance synchrotron X-ray sources and free-electron lasers urges the development of novel diagnostic techniques for measuring and monitoring the spatial source properties, especially the source sizes. This work introduces an X-ray beam property analyzer based on a multi-crystal diffraction geometry, including a crystal-based monochromator and a Laue crystal in a dispersive setting to the monochromator. By measuring the flat beam and the transmitted beam profiles, the system can provide a simultaneous high-sensitivity characterization of the source size, divergence, position, and angle in the diffraction plane of the multi-crystal system. Detailed theoretical modeling predicts the system’s feasibility as a versatile characterization tool for monitoring the X-ray source and beam properties. The experimental validation was conducted at a bending magnet beamline at the Swiss Light Source by varying the machine parameters. A measurement sensitivity of less than 10% of a source size of around 12 µm is demonstrated. The proposed system offers a compact setup with simple X-ray optics and can also be utilized for monitoring the electron source.
Anomalies in radio-frequency (rf) stations can result in unplanned downtime and performance degradation in linear accelerators such as SLAC’s Linac Coherent Light Source (LCLS). Detecting these anomalies is challenging due to the complexity of accelerator systems, high data volume, and scarcity of labeled fault data. Prior work identified faults using beam-based detection, combining rf amplitude and beam position monitor data. Due to the simplicity of the rf amplitude data, classical methods are sufficient to identify faults, but the recall is constrained by the low-frequency and asynchronous characteristics of the data. In this work, we leverage high-frequency, time-synchronous rf phase data to enhance anomaly detection in the LCLS accelerator. Due to the complexity of phase data, classical methods fail, and we instead train deep neural networks within the Coincident Anomaly Detection (CoAD) framework. We find that applying CoAD to phase data detects nearly 3 times as many anomalies as when applied to amplitude data, while achieving broader coverage across rf stations. Furthermore, the rich structure of phase data enables us to cluster anomalies into distinct physical categories. Through the integration of auxiliary system status bits, we link clusters to specific fault signatures, providing additional granularity for uncovering the root cause of faults. We also investigate interpretability via Shapley values, confirming that the learned models focus on the most informative regions of the data and providing insight for cases where the model makes mistakes. This work demonstrates that phase-based anomaly detection for rf stations improves both diagnostic coverage and root cause analysis in accelerator systems and that deep neural networks are essential for effective analysis.
A novel x-ray free electron laser (XFEL) diffraction setup for use with diamond anvil cells (DACs) at the Linac Coherent Light Source (LCLS) is described. Using the new diamond window at the Matter at Extreme Conditions (MEC) instrument, it allows hard x-ray experiments on DACs to be performed in air. The platform is described along with alignment and calibration procedures and details of the x-ray beam and diagnostics. Example data are presented, including a reversible XFEL induced phase transition in CsPbI3. The DAC setup was commissioned at MEC, but is applicable to most LCLS instruments where the unique pulse structures available at LCLS offer access to new ultrafast experimental techniques at high pressure.
We report on a week-long study of a conceptual design of EUV FEL light source based on an energy recovery linac with on-orbit laser plasma accelerator injection scheme. We carried out this study during USPAS Summer 2023 session of Unifying Physics of Accelerators, Lasers and Plasma applying the art of inventiveness TRIZ. An ultrashort Ti-sapphire laser accelerates electron beams from a gas target with mean energy of 20 MeV, which are then ramped up to 1 GeV in a five-turn scheme with a series of fixed field alternating magnets and two superconducting RF cavities (100 MeV per cavity per turn). The electron beam is then bypassed to an undulator line optimized to generate EUV light of 13.5 nm at kW level in a single pass.
Silicon is the most scalable optoelectronic material but has suffered from its inability to generate directly and efficiently classical or quantum light on-chip. Scaling and integration are the most fundamental challenges facing quantum science and technology. We report an all-silicon quantum light source based on a single atomic emissive center embedded in a silicon-based nanophotonic cavity. We observe a more than 30-fold enhancement of luminescence, a near-unity atom-cavity coupling efficiency, and an 8-fold acceleration of the emission from the all-silicon quantum emissive center. Our work opens immediate avenues for large-scale integrated cavity quantum electrodynamics and quantum light-matter interfaces with applications in quantum communication and networking, sensing, imaging, and computing.
An endstation for resonant inelastic X-ray scattering (RIXS), dedicated to operations in the hard X-ray regime, has been constructed at the 1C beamline of Pohang Light Source II. At the Ir L 3 -edge, a total energy resolution of 34.2 meV was achieved, close to the theoretical estimation of 34.0 meV, which considers factors such as the incident energy bandpass, intrinsic analyzer resolution, geometrical broadening of the spectrometer, finite beam-size effect and Johann aberration. The performance of the RIXS instrument is demonstrated by measuring the RIXS spectra of Sr 2 IrO 4 . The endstation can be easily reconfigured to measure energy-integrated intensities with very low background for diffuse scattering and diffraction experiments.
Having previously reported that separating the two stages of echo-enabled harmonic generation (EEHG) with one or more bending magnet (BM) sections allows the BMs to serve as the desired source of momentum compaction, here we demonstrate that this arrangement can greatly reduce the total energy modulation required by any 4th generation synchrotron light source, leading to higher repetition rates as well as stronger coherent radiation output power, with significant benefits. Since the EEHG beamline performance is mainly determined by the momentum compaction, beam emittances and beta functions of a storage ring lattice, allowing for different separations between the two stages is a straightforward way to increase the momentum compaction of chicane 1. This also enables pump-probe capabilities in a novel context, where twin-pulse seeding on the same electron bunch would allow two distinct radiation pulses with an adjustable delay in the range of 0.1 to 10 ps. In the twin-pulse seeding scheme, the same electron bunch could undergo modulation from two distinct laser pulses. Later stages would produce independent harmonics in subsequent straight sections. There are two variations of this twin-pulse seeding scheme, supporting different scientific applications. With a common modulation in stage 1, the first option allows simultaneously two independent radiation sources, with a full coverage of the EUV (2.5 to 50 nm) to soft X-ray (1.25 to 2.5 nm) spectrum; for the second option, the same stage 2 undulator could generate two coherent pulses both fitting within the FEL bandwidth, or at distinct harmonics. We present particle tracking simulation studies based on the APS-U lattice, including quantum excitation and radiation damping. These simulations indicate that there is no degradation of the modulated longitudinal phase space even when the two stages are separated by as many as 10 BM sections.