A New Light for Berkeley Lab—the Advanced Light Source Upgrade

The Advanced Light Source Upgrade Project (ALS-U) will leverage multibend achromat technology to endow the ALS with revolutionary soft X-ray capabilities, and has recently received formal approval to proceed to the preliminary design phase. Soft X-rays are a critical diagnostic tool for enabling the understanding and control of heterogeneous, hierarchical functional materials and chemical synthesis platforms since they can reveal chemical, electronic, and magnetic properties with very high sensitivity. Although the ALS has a strong track record in soft X-ray science over the last 25 years, it, like most other existing storage-ring-based X-ray light sources, lacks the simultaneous combination of nanometer spatial resolution, diverse spectroscopic contrast, and broad temporal sensitivity required to image the location of molecules, ions, and electrons, and to measure how their components migrate and interact to support efficient function. The high coherent flux of the upgraded ALS willenable a suite of tools that encompass 3D nanoscale imaging with high spectral sensitivity over broad space and time scales, dramatically amplifying the already high impact of ALS soft X-ray spectroscopies. Relative to many other synchrotron light source upgrade projects or new facilities being built today, the upgraded ALS will operate at a low electron-beam energy of 2 GeV and a high current of 500 mA, and is optimized for soft X-rays. Its soft X-ray coherent flux will be orders of magnitude higher than that of the existing ALS and beyond the coherent flux of any storage-ring-based light source operating, under construction, or currently planned. In total, the upgraded facility will provide an unprecedented combination of high stability, quasi-continuous radiation, and the highest possible coherent soft X-ray flux.

47 OTHER INSTRUMENTATION↗

Characterization of spatially resolved high resolution x-ray spectrometers for high energy density physics and light source experiments

A high resolution 1D imaging x-ray spectrometer concept comprising a spherically bent crystal and a 2D pixelated detector is being optimized for diagnostics of small sources such as high energy density physics (HEDP) and synchrotron radiation or x-ray free electron laser experiments. This instrument is used on tokamak experiments for Doppler measurements of ion temperature and plasma flow velocity profiles. Laboratory measurements demonstrate a resolving power, E/ΔE of order 10 000 and spatial resolution better than 10 μm. Initial tests of the high resolution instrument on HEDP plasmas are being performed.

43 PARTICLE ACCELERATORS↗

Tracking Steady Light Sources Amid Luminous Transients

The Transient Event Rejection for Acquisition and Tracking (TERAT) algorithm governs operation of image-data-acquisition and -processing system. TERAT processes digitized image data to acquire (that is, identify) candidate steady source of light, validate candidate source, and track validated source, all in presence of real or apparent luminous transients represented in image data. Source of light tracked could be star or distant luminous beacon. Transients caused by impacts of ionizing radiation on imaging array of photodetectors or by unsteady light sources not meant to be tracked. TERAT functions with limited data-processing resources. TERAT algorithm currently operational on NASA's TOPEX mission.

Kissh, Frank↗

Advancements and Application of Microsecond Synchrotron X-ray Footprinting at the Advanced Light Source

The method of synchrotron X-ray protein footprinting (XF-MS) is used to determine protein conformational changes, folding, protein-protein and protein-ligand interactions, providing information which is often difficult to obtain using X-ray crystallography and other common structural biology methods [1–3]. The technique uses comparative in situ labeling of solvent-accessible side chains by highly reactive hydroxyl radicals (•OH) in buffered aqueous solution under different assay conditions. In regions where a protein is folded or binds a partner, these •OH susceptible sites are inaccessible to solvent, and therefore protected from labeling. The •OH are generated by the ionization of water using high-flux-density X-rays. High-flux density is a key factor for XF-MS labeling because obtaining an adequate steady-state concentration of hydroxyl radical within a short irradiation time is necessary to minimize radiation-induced secondary damage and also to overcome various scavenging reactions that reduce the yield of labeled side chains.

47 OTHER INSTRUMENTATION↗

APS upgrade: Commissioning the world’s first light source based on swap-out injection

The Advanced Photon Source (APS) has recently completed a major upgrade, replacing its 25-year-old storage ring with a cutting-edge hybrid seven-bend achromat lattice enhanced by six additional reverse bends. The new design achieves a natural emittance of 42 pm-rad, enabling the production of X-rays up to 500 times brighter than those generated by the original APS. A key innovation of the upgrade is the implementation of a swap-out injection scheme, which replaces entire depleted bunches instead of performing traditional top-up injection. This approach enables on-axis injection to accommodate for the reduced dynamic aperture resulting from strong focusing. This paper outlines the commissioning process, shares initial operating experience with swap-out injection, and presents performance data for new systems such as the bunch-lengthening cavity.

Sajaev, Vadim [Argonne, PHY]↗

The electron spectro-microscopy beamline at National Synchrotron Light Source II: A wide photon energy range, micro-focusing beamline for photoelectron spectro-microscopies

A comprehensive optical design for a high-resolution, high-flux, wide-energy range, micro-focused beamline working in the vacuum ultraviolet and soft x-ray photon energy range is proposed. The beamline is to provide monochromatic radiation to three photoelectron microscopes: a full-field x-ray photoelectron emission microscope and two scanning instruments, one dedicated to angle resolved photoemission spectroscopy ({mu}-ARPES) and one for ambient pressure x-ray photoelectron spectroscopy and scanning photoelectron microscopy (AP-XPS/SPEM). Microfocusing is achieved with state of the art elliptical cylinders, obtaining a spot size of 1 {mu}m for ARPES and 0.5 {mu}m for AP-XPS/SPEM. A detailed ray tracing analysis quantitatively evaluates the overall beamline performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the SAGA Light Source

The SAGA Light Source (SAGA-LS) is a synchrotron radiation facility consisting of a 255 MeV injector linac and a 1.4 GeV storage ring that is 75.6 m in circumference. The SAGA-LS has been stably providing synchrotron radiation to users since it first started user operation in February 2006. Along with the user operation, various machine improvements have been made over the past years, including upgrading the injector linac control system, replacing a septum magnet and constructing a beam diagnostic system. In addition to these improvements, insertion devices have been developed and installed. An APPLE-II type variable polarization undulator was installed in 2008. To address the demand from users for high-flux hard x-rays, a superconducting 4 T class wiggler is being developed. An experimental setup for generating MeV photons by laser Compton scattering is being constructed for beam monitoring and future user experiments.

43 PARTICLE ACCELERATORS↗

Data automation at light sources

Rapidly growing data volumes at light sources demand increasingly automated data collection, distribution, and analysis processes, in order to enable new scientific discoveries while not overwhelming finite human capabilities. We present here the case for automating and outsourcing light source science using cloud-hosted data automation and enrichment services, institutional computing resources, and high- performance computing facilities to provide cost-effective, scalable, and reliable implementations of such processes. We discuss three specific services that accomplish these goals for data distribution, automation, and transformation. In the first, Globus cloud-hosted data automation services are used to implement data capture, distribution, and analysis workflows for Advanced Photon Source and Advanced Light Source beamlines, leveraging institutional storage and computing. In the second, such services are combined with cloud-hosted data indexing and institutional storage to create a collaborative data publication, indexing, and discovery service, the Materials Data Facility (MDF), built to support a host of informatics applications in materials science. The third integrates components of the previous two projects with machine learning capabilities provided by the Data and Learning Hub for science (DLHub) to enable on-demand access to machine learning models from light source data capture and analysis workflows, and provides simplified interfaces to train new models on data from sources such as MDF on leadership scale computing resources. We draw conclusions about best practices for building next-generation data automation systems for future light sources.

Blaiszik, Ben↗

Microelectromechanical Systems (MEMS) Broadband Light Source Developed

A miniature, low-power broadband light source has been developed for aerospace applications, including calibrating spectrometers and powering miniature optical sensors. The initial motivation for this research was based on flight tests of a Fabry-Perot fiberoptic temperature sensor system used to detect aircraft engine exhaust gas temperature. Although the feasibility of the sensor system was proven, the commercial light source optically powering the device was identified as a critical component requiring improvement. Problems with the light source included a long stabilization time (approximately 1 hr), a large amount of heat generation, and a large input electrical power (6.5 W). Thus, we developed a new light source to enable the use of broadband optical sensors in aerospace applications. Semiconductor chip-based light sources, such as lasers and light-emitting diodes, have a relatively narrow range of emission wavelengths in comparison to incandescent sources. Incandescent light sources emit broadband radiation from visible to infrared wavelengths; the intensity at each wavelength is determined by the filament temperature and the materials chosen for the filament and the lamp window. However, present commercial incandescent light sources are large in size and inefficient, requiring several watts of electrical power to obtain the desired optical power, and they emit a large percentage of the input power as heat that must be dissipated. The miniature light source, developed jointly by the NASA Glenn Research Center, the Jet Propulsion Laboratory, and the Lighting Innovations Institute, requires one-fifth the electrical input power of some commercial light sources, while providing similar output light power that is easily coupled to an optical fiber. Furthermore, it is small, rugged, and lightweight. Microfabrication technology was used to reduce the size, weight, power consumption, and potential cost-parameters critical to future aerospace applications. This chip-based light source has the potential for monolithic fabrication with on-chip drive electronics. Other uses for these light sources are in systems for vehicle navigation, remote sensing applications such as monitoring bridges for stress, calibration sources for spectrometers, light sources for space sensors, display lighting, addressable arrays, and industrial plant monitoring. Two methods for filament fabrication are being developed: wet-chemical etching and laser ablation. Both yield a 25-mm-thick tungsten spiral filament. The proof-of-concept filament shown was fabricated with the wet etch method. Then it was tested by heating it in a vacuum chamber using about 1.25 W of electrical power; it generated bright, blackbody radiation at approximately 2650 K. The filament was packaged in Glenn's clean-room facilities. This design uses three chips vacuum-sealed with glass tape. The bottom chip consists of a reflective film deposited on silicon, the middle chip contains a tungsten filament bonded to silicon, and the top layer is a transparent window. Lifetime testing on the package will begin shortly. The emitted optical power is expected to be approximately 1.0 W with the spectral peak at 1.1 mm.

Tuma, Margaret L.↗

A transverse bunch by bunch feedback system for Pohang Light Source upgrade

The Pohang Light Source upgrade (PLS-II) project has successfully upgraded the Pohang Light Source (PLS). The main goals of the PLS-II project are to increase the beam energy to 3 GeV, increase the number of insertion devices by a factor of two (20 IDs), increase the beam current to 400 mA, and at the same time reduce the beam emittance to below 10 nm by using the existing PLS tunnel and injection system. Among 20 insertion devices, 10 narrow gap in-vacuum undulators are in operation now and two more in-vacuum undulators are to be installed later. Since these narrow gap in-vacuum undulators are most likely to produce coupled bunch instability by the resistive wall impedance and limit the stored beam current, a bunch by bunch feedback system is implemented to suppress coupled bunch instability in the PLS-II. This paper describes the scheme and performance of the PLS-II bunch by bunch feedback system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Steady State Microbunching for High Brilliance and High Repetition Rate Storage Ring-Based Light Sources

Electron-based light sources have proven to be effective sources of high brilliance, high frequency radiation. Such sources are typically either linac-Free Electron Laser (FEL) or storage ring types. The linac-FEL type has high brilliance (because the beam is microbunched) but low repetition rate. The storage ring type has high repetition rate (rapid beam circulation) but comparatively low brilliance or coherence. We propose to explore the feasibility of a microbunched beam in a storage ring that promises high repetition rate and high brilliance. The steady-state-micro-bunch (SSMB) beam in storage ring could provide CW sources for THz, EUV, or soft X-rays. Several SSMB mechanisms have been suggested recently, and in this report, we review a number of these SSMB concepts as promising directions for high brilliance, high repetition rate light sources of the future. The trick of SSMB lies in the RF system, together with the associated synchrotron beam dynamics, of the storage ring. Considering various different RF arrangements, there could be considered a number of scenarios of the SSMB. In this report, we arrange these scenarios more or less in order of the envisioned degree of technical challenge to the RF system, and not in the chronological order of their original references. Once the stored beam is steady-state microbunched in a storage ring, it passes through a radiator repeatedly every turn (or few turns). The radiator extracts a small fraction of the beam energy as coherent radiation with a wavelength corresponding to the microbunched period of the beam. In contrast to an FEL, this radiator is not needed to generate the microbunching (as required e.g. by SASE FELs or seeded FELs), so the radiator can be comparatively simple and short.

43 PARTICLE ACCELERATORS↗

Electron beam emittance at operational intensity in fourth-generation synchrotron light sources

For synchrotron light sources, the brightness of user X-ray beams is primarily determined by the electron beam emittance and energy spread at operational intensity. A common feature of fourth-generation synchrotrons is the short length of electron bunches combined with a very small transverse beam size. Consequently, the particle density is much higher than in machines of previous generations, leading to strong collective effects that significantly increase the emittance and limit the achievable brightness at operational beam intensity. In this article, we summarize our studies of the emittance scaled with the beam energy and intensity, taking into account the effects of intrabeam scattering, beam-impedance interaction, and bunch lengthening provided by higher-harmonic RF systems, to identify optimal combinations of machine and beam parameters.

43 PARTICLE ACCELERATORS↗

Macromolecular crystallography and biology at the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) has significantly impacted the field of biology by providing advanced capabilities for probing the structure and dynamics of biological molecules with high precision. The ultrashort coherent X-ray pulses from the LCLS have enabled ultrafast, time-resolved, serial femtosecond crystallography that is inaccessible at conventional synchrotron light sources. Since the facility's founding, scientists have captured detailed insights into biological processes at atomic resolution and fundamental timescales. The ability to observe these processes in real time and under conditions closely resembling their natural state is transforming our approach to studying biochemical mechanisms and developing new medical and energy applications. This work recounts some of the history of the LCLS, advances in biological research enabled by the LCLS, key biological areas that have been impacted and how the LCLS has helped to unravel complex biological phenomena in these fields.

59 BASIC BIOLOGICAL SCIENCES↗

Toward Control of Matter: Basic Energy Science Needs for a New Class of X-Ray Light Sources

Over the past quarter century, light-source user facilities have transformed research in areas ranging from gas-phase chemical dynamics to materials characterization. The ever-improving capabilities of these facilities have revolutionized our ability to study the electronic structure and dynamics of atoms, molecules, and even the most complex new materials, to understand catalytic reactions, to visualize magnetic domains, and to solve protein structures. Yet these outstanding facilities still have limitations well understood by their thousands of users. Accordingly, over the past several years, many proposals and conceptual designs for"next-generation" x-ray light sources have been developed around the world. In order to survey the scientific problems that might be addressed specifically by those new light sources operating below a photon energy of about 3 keV and to identify the scientific requirements that should drive the design of such facilities, a workshop"Science for a New Class of Soft X-Ray Light Sources" was held in Berkeley in October 2007. From an analysisof the most compelling scientific questions that could be identified and the experimental requirements for answering them, we set out to define, without regard to the specific technologies upon which they might be based, the capabilities such light sources would have to deliver in order to dramatically advance the state of research in the areas represented in the programs of the Department of Energy's Office of Basic Energy Sciences (BES). This report is based on the workshop presentations and discussions.

36 MATERIALS SCIENCE↗

Novel Multiple-Gigahertz Electron Beams for Advanced X-Ray and Gamma-Ray Light Sources

Current and future generations of advanced light sources largely depend on high brightness electron beams. LLNL has spent the past decade developing Mono-Energetic Gamma-ray (MEGa-ray) sources by scattering laser light off an electron beam for nuclear physics applications. At the SLAC National Accelerator Laboratory, the Linac Coherent Light Source (LCLS) is generating extraordinarily high peak brightness x-ray beams useful for biological, chemical, and physics studies by passing a 13.6 GeV electron beam through a series of magnetic undulators to form a Free-Electron Laser (FEL). Los Alamos is in the process developing the “MaRIE” (Matter-Radiation Interactions in Extremes) concept, which will also rely on FELs. All these light sources would benefit from improved average brightness by increasing the repetition rate of the electron beam source. Since the undulators are based on permanent magnets, they will generate x-rays from as many electron bunches as can be delivered. Similarly, for MEGa-ray sources very little laser light is scattered from each individual electron bunch. If there are additional electron bunches to see the laser, they will also scatter photons, generating more gamma-rays. Modeling has shown that using trains of hundreds of electron bunches allows high gamma-ray fluxes to be generated using ns-long scattering laser pulses. This means that chirped pulse amplification would not be needed for the interaction laser, considerably simplifying the architecture. This would also allow for lower laser bandwidth at the interaction point, along with a larger focal spot size, eliminating the laser contribution to the scattered gamma-ray bandwidth. Additionally, lower charge per bunch allows more flexibility in the transport, simplifying efforts to mitigate noise-inducing dark current. The overarching goal of the proposed research is to develop and demonstrate the required technology to generate multi-GHz rep-rate electron beams at pC-scale bunch charges to allow 100x increases in the average beam current. To achieve this, the project consisted of two major efforts: 1. Demonstration of a photocathode drive laser capable of generating the electron beam. 2. Commissioning of an x-band accelerator to enable studies of inter-bunch electromagnetic field interactions. Excellent results were achieved in both areas.

42 ENGINEERING↗

Report of the Basic Energy Sciences Workshop on Compact Light Sources

This report is based on a BES Workshop on Compact Light Sources, held May 11-12, 2010, to evaluated the advantages and disadvantages of compact light source approaches and compared their performance to the third generation storage rings and free-electron lasers. The workshop examined the state of the technology for compact light sources and their expected progress. The workshop evaluated the cost efficiency, user access, availability, and reliability of such sources. Working groups evaluated the advantages and disadvantages of Compact Light Source (CLS) approaches, and compared their performance to the third-generation storage rings and free-electron lasers (FELs). The primary aspects of comparison were 1) cost effectiveness, 2) technical availability v. time frame, and 3) machine reliability and availability for user access. Five categories of potential sources were analyzed: 1) inverse Compton scattering (ICS) sources, 2) mini storage rings, 3) plasma sources, 4) sources using plasma-based accelerators, and 5) laser high harmonic generation (HHG) sources. Compact light sources are not a substitute for large synchrotron and FEL light sources that typically also incorporate extensive user support facilities. Rather they offer attractive, complementary capabilities at a small fraction of the cost and size of large national user facilities. In the far term they may offer the potential for a new paradigm of future national user facility. In the course of the workshop, we identified overarching R&D topics over the next five years that would enhance the performance potential of both compact and large-scale sources: Development of infrared (IR) laser systems delivering kW-class average power with femtosecond pulses at kHz repetition rates. These have application to ICS sources, plasma sources, and HHG sources. Development of laser storage cavities for storage of 10-mJ picosecond and femtosecond pulses focused to micron beam sizes. Development of high-brightness, high-repetition-rate electron sources. Development of continuous wave (cw) superconducting rf linacs operating at 4 K, while not essential, would reduce capital and operating cost.

47 OTHER INSTRUMENTATION↗