Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light field imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Probabilistic Extraction Of Vectors In PIV

Probabilistic technique for extraction of velocity vectors in particle-image velocimetry (PIV) implemented with much less computation. Double-exposure photograph of particles in flow illuminated by sheet of light provides data on velocity field of flow. Photograph converted into video image then digitized and processed by computer into velocity-field data. Velocity vectors in interrogation region chosen from magnitude and angle histograms constructed from centroid map of region.

Humphreys, William M., Jr.↗

ENLIGHTEN: Electrical Network Line Inspection Guided by High-Speed Technology & Electromagnetic Navigation

Natural disasters are a major cause of power outages, primarily due to their damage to power line infrastructure. As a result, the current state of power maintenance, with a heavy reliance on manual labor, is in trouble. Its lack of speed and autonomy must be addressed to ensure power security for households and institutions worldwide. This innovative approach explores how High-Speed Unmanned Aerial Vehicle (HSUAV) technology can inspect power line infrastructure rapidly in response to natural disaster scenarios. The HSUAV technology will be accompanied by enhanced sensory equipment including light detection and ranging (LiDAR), thermal imaging, and electromagnetic field (EMF) navigation. It would also be supplemented by innovative forms of machine learning models and recharging systems to efficiently detect anomalies in power line infrastructure. The proposed system, ENLIGHTEN, can help restore power in affected communities after a devastating natural disaster, greatly improving relief efforts. In the future, ENLIGHTEN can be expanded beyond the United States and shared worldwide, effectively mitigating the consequences on a larger scale.

UAV systems, Power line management, Natural disast↗

Detection and Interpretation of Long-lived X-Ray Quasi-Periodic Pulsations in the X-Class Solar Flare on 2013 May 14

Quasi-periodic pulsations (QPP) seen in the time derivative of the GOES soft X-ray light curves are analyzed for the X3.2 event on 2013 May 14. The pulsations are apparent for a total of at least two hours from the impulsive phase to well into the decay phase, with a total of 163 distinct pulses evident to the naked eye. A wavelet analysis shows that the characteristic timescale of these pulsations increases systematically from approx. 25 s at 01:10 UT, the time of the GOES peak, to approx. 100 s at 02:00 UT. A second ridge in the wavelet power spectrum, most likely associated with flaring emission from a different active region, shows an increase from approx. 40 s at 01:40 UT to approx. 100 s at 03:10 UT. We assume that the QPP that produced the first ridge result from vertical kink-mode oscillations of the newly formed loops following magnetic reconnection in the coronal current sheet. This allows us to estimate the magnetic field strength as a function of altitude given the density, loop length, and QPP timescale as functions of time determined from the GOES light curves and Ramaty High Energy Solar Spectroscopic Imager (RHESSI) images. The calculated magnetic field strength of the newly formed loops ranges from approx. 500 G at an altitude of 24Mm to a low value of approx. 10 G at 60 Mm, in general agreement with the expected values at these altitudes. Fast sausage-mode oscillations are also discussed and cannot be ruled out as an alternate mechanism for producing the QPP.

Dennis, Brian R.↗

Hubble Space Telescope Medium Deep Survey. 2: Deconvolution of Wide Field Camera field galaxy images in the 13 hour + 43 deg field

We present isophotal profiles of six faint field galaxies from some of the first deep images taken for the Hubble Space Telescope (HST) Medium Deep Survey (MDS). These have redshifts in the range z = 0.126 to 0.402. The images were taken with the Wide Field Camera (WFC) in `parallel mode' and deconvolved with the Lucy method using as the point-spread function nearby stars in the image stack. The WFC deconvolutions have a dynamic range of 16 to 20 dB (4 to 5 mag) and an effective resolution approximately less than 0.2 sec (FWHM). The multiorbit HST images allow us to trace the morphology, light profiles, and color gradients of faint field galaxies down to V approximately equal to 22 to 23 mag at sub-kpc resolution, since the redshift range covered is z = 0.1 to 0.4. The goals of the MDS are to study the sub-kpc scale morphology, light profiles, and color gradients for a large samole of faint field galaxies down to V approximately equal to 23 mag, and to trace the fraction of early to late-type galaxies as function of cosmic time. In this paper we study the brighter MDS galaxies in the 13 hour + 43 deg MDS field in detail, and investigate to what extent model fits with pure exponential disks or a(exp 1/4) bulges are justified at V approximately less than 22 mag. Four of the six field galaxies have light profiles that indicate (small) inner bulges following r(exp 1/4) laws down to 0.2 sec resolution, plus a dominant surrounding exponential disk with little or no color gradients. Two occur in a group at z = 0.401, two are barred spiral galaxies at z = 0.179 and z = 0.302, and two are rather subluminous (and edge-on) disk galaxies at z = 0.126 and z = 0.179. Our deep MDS images can detect galaxies down to V, I approximately less than 25 to 26 mag, and demonstrate the impressive potential of HST--even with its pre-refurbished optics--to resolve morphological details in galaxies at cosmologically significant distances (v approximately less than 23 mag). Since the median redshift of these galaxies is approximately less than 0.4, the HST resolution allows us to study sub kpc size scales at the galaxy, which cannot be done with stable images over wide fields from the best ground-based sites.

Windhorst, R. A.↗

Digital PIV Measurements of Acoustic Particle Displacements in a Normal Incidence Impedance Tube

Acoustic particle displacements and velocities inside a normal incidence impedance tube have been successfully measured for a variety of pure tone sound fields using Digital Particle Image Velocimetry (DPIV). The DPIV system utilized two 600-mj Nd:YAG lasers to generate a double-pulsed light sheet synchronized with the sound field and used to illuminate a portion of the oscillatory flow inside the tube. A high resolution (1320 x 1035 pixel), 8-bit camera was used to capture double-exposed images of 2.7-micron hollow silicon dioxide tracer particles inside the tube. Classical spatial autocorrelation analysis techniques were used to ascertain the acoustic particle displacements and associated velocities for various sound field intensities and frequencies. The results show that particle displacements spanning a range of 1-60 microns can be measured for incident sound pressure levels of 100-130 dB and for frequencies spanning 500-1000 Hz. The ability to resolve 1 micron particle displacements at sound pressure levels in the 100 dB range allows the use of DPIV systems for measurement of sound fields at much lower sound pressure levels than had been previously possible. Representative impedance tube data as well as an uncertainty analysis for the measurements are presented.

Humphreys, William M., Jr.↗

Image quality prediction - An aid to the Viking lander imaging investigation on Mars

Image quality criteria and image quality predictions are formulated for the multispectral panoramic cameras carried by the Viking Mars landers. Image quality predictions are based on expected camera performance, Mars surface radiance, and lighting and viewing geometry (fields of view, Mars lander shadows, solar day-night alternation), and are needed in diagnosis of camera performance, in arriving at a preflight imaging strategy, and revision of that strategy should the need arise. Landing considerations, camera control instructions, camera control logic, aspects of the imaging process (spectral response, spatial response, sensitivity), and likely problems are discussed. Major concerns include: degradation of camera response by isotope radiation, uncertainties in lighting and viewing geometry and in landing site local topography, contamination of camera window by dust abrasion, and initial errors in assigning camera dynamic ranges (gains and offsets).

Huck, F. O.↗

Anastigmatic three-mirror telescope

Proposed three-mirror telescope provides high resolution over flat image field of 1.5 degrees. Telescope also suppresses stray-light without elaborate baffling system, making it well suited for space astronomy and other high performance and low-light level applications.

Korsch, D.↗

The forecasting center of Meudon, France

Main features of solar activity are described in relation to solar and geophysical forecasting. Spectroheliograms, radio and X-ray data, white light coronal observations, particles data, photospheric images, and photospheric magnetic fields are among the types of data used to identify the active centers and flares of the Sun. Forecasting and identification of geomagnetic activity is also discussed. The forecasting technique is described along with the types of users.

Simon, P.↗

Color/magnitude calibration for National Aeronautics and Space Administration (NASA) standard Fixed-Head Star Trackers (FHST)

This paper characterizes and analyzes the spectral response of Ball Aerospace fixed-head star trackers, (FHST's) currently in use on some three-axis stabilized spacecraft. The FHST output is a function of the frequency and intensity of the incident light and the position of the star image in the field of view. The FHST's on board the Extreme Ultraviolet Explorer (EUVE) have had occasional problems identifying stars with a high B-V value. These problems are characterized by inaccurate intensity counts observed by the tracker. The inaccuracies are due to errors in the observed star magnitude values. These errors are unique to each individual FHST. For this reason, data were also collected and analyzed from the Upper Atmosphere Research Satellite (UARS). As a consequence of this work, the Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD) hopes to improve the attitude accuracy on these missions and to adopt better star selection procedures for catalogs.

Landis, J.↗

ELM: Europa Luminescence Microscope

The Europa Luminescence Microscope (ELM) is an automated fluorescence and bright-field microscope designed to meet key objectives defined in the 2016 NASA Europa Lander Study Report, including the identification and characterization of morphological biosignatures. ELM’s heritage stems from a 2U cubesat fluorescence microscope, the Fluorescence Analysis for In situ Research imager, designed and built at NASA Ames Research Center, for the autonomous study of microbial biology in low Earth orbit. For ELM implementation, a sample is autonomously manipulated with a microfluidic system using in-line 10, 1.0, and 0.2 μm pore-size filters to capture successively smaller particles for imaging. For bright-field imaging, ELM uses deep-ultraviolet, ultraviolet and visible light to image organic and inorganic structures with submicron resolution. The ability to detect biosignatures as small as 0.2 μm in size is achieved by imaging native fluorescence and using fluorescence microscopy stains to identify key structural and functional indicators of microbial life (proteins, lipids, nucleic acids). For fluorescence imaging, ELM uses 265, 370, 470, and 530 nm LEDs with five emission bands. The use of multiple excitation and emission wavelengths for native fluorescence imaging enables the detection of a wide range of molecular species and their rough classification. Excitation at 265 nm allows for the detection of smaller polycyclic aromatic hydrocarbons (PAH), aromatic amino acids, and proteins with little to no interference from mineral fluorescence, given proper emission band selection. 370 and 470 nm light excites increasingly larger PAH structures and larger aromatic biomolecules that may be present (e.g., protective pigments). Similarly, inorganic fluorescence can be characterized and separated from organic fluorescence, allowing the recognition and in some cases classification, of minerals and other abiotic particles. ELM is based upon work supported by the NASA COLDTech and ICEE-2 programs.

Richard C Quinn↗

Focused Schlieren flow visualization studies of multiple venturi fuel injectors in a high pressure combustor

Multiple venturi fuel injectors were used to obtain uniform fuel distributions, better atomization and vaporization in the premixing/prevaporizing section of a lean premixed/prevaporized flame tube combustor. A focused Schlieren system was used to investigate the fuel/air mixing effectiveness of various fuel injection configurations. The Schlieren system was focused to a plane within the flow field of a test section equipped with optical windows. The focused image plane was parallel to the axial direction of the flow and normal to the optical axis. Images from that focused plane, formed by refracted light due to density gradients within the flow field, were filmed with a high-speed movie camera at framing rates of 8,000 frames per second (fps). Three fuel injection concepts were investigated by taking high-speed movies of the mixture flows at various operating conditions. The inlet air temperature was varied from 600 F to 1000 F, and inlet pressures from 80 psia to 150 psia. Jet-A fuel was used typically at an equivalence ratio of 0.5. The intensity variations of the digitized Schlieren images were analytically correlated to spatial density gradients of the mixture flows. Qualitative measurements for degree of mixedness, intensity of mixing, and mixing completion time are shown. Various mixing performance patterns are presented with different configurations of fuel injection points and operating conditions.

Chun, K. S.↗

Collecting Light From Point Images

Light from sources at varying positions brought to fixed opening. In telescope field divided into 10 strips, 10 pairs of optical fibers moved laterally and longitudinally to any required position in their assigned strips. Fixed ends of fibers arrayed in line at spectrograph entrance slit. Concept developed to enhance efficiency of spectrographs on astronomical telescopes.

Goss, W. C.↗

Upping the TEMPO on Air Pollution Observations from Space for Enhanced Science Applications

The Tropospheric Emissions: Monitoring of Pollution (TEMPO) mission was launched into Geostationary Earth Orbit (GEO) to 91°W longitude on April 7, 2023, and had a successful First Light period from July 31 – August 2 where the first hourly daytime scans across the TEMPO Field of Regard (FoR) covering greater North America were performed. First light images of nitrogen dioxide (NO2) were released to the public on August 24. In addition to NO2, TEMPO will provide hourly daytime observations of formaldehyde (HCHO), sulfur dioxide (SO2), ozone (O3), bromine (BrO), water vapor (H2O), and aerosols, at high spatial resolution (~2.0 x 4.75 km2) across the FoR. The hyperspectral ultraviolet-to-visible measurements from the TEMPO imaging grating spectrometer will permit an ozone profile retrieval capable of monitoring the diurnal evolution of ozone in the planetary boundary layer. The non-standard or special scan operations of TEMPO at sub-hourly frequency (e.g., 2-10 minutes) over selected slices of the FoR will further enhance monitoring capabilities during air quality disasters (e.g., wildfires, volcanic eruptions, dust storms, industrial accidents), research studies, and field campaign operations. A large diversity of stakeholders and end-users have been engaged in the TEMPO Early Adopters Program, supported by the NASA Applied Sciences Program, which aims to enhance health and air quality applications and maximize the societal benefit of TEMPO data when operational data becomes publicly available in the spring of 2024. Key outcomes from the Early Adopters Program include the pre-launch use of TEMPO proxy data to prepare the community for operational data, tailoring the data dissemination and visualization tools for the mission based on user needs, and enhancing the TEMPO special operations component of the mission through early adopter studies. This presentation will provide the latest TEMPO mission and Early Adopters Program updates, initiatives from the TEMPO special operations, and early demonstrations of science applications enabled through TEMPO data, while also showcasing the First Light imagery.

Air Quality↗

SOFIA Science Instruments: Commissioning, Upgrades and Future Opportunities

The Stratospheric Observatory for Infrared Astronomy (SOFIA) is the world's largest airborne observatory, featuring a 2.5 meter telescope housed in the aft section of a Boeing 747sp aircraft. SOFIA's current instrument suite includes: FORCAST (Faint Object InfraRed CAmera for the SOFIA Telescope), a 5-40 μm dual band imager/grism spectrometer developed at Cornell University; HIPO (High-speed Imaging Photometer for Occultations), a 0.3-1.1 micron imager built by Lowell Observatory; FLITECAM (First Light Infrared Test Experiment CAMera), a 1-5 micron wide-field imager/grism spectrometer developed at UCLA; FIFI-LS (Far-Infrared Field-Imaging Line Spectrometer), a 42-210 micron IFU grating spectrograph completed by University Stuttgart; and EXES (Echelon-Cross- Echelle Spectrograph), a 5-28 micron high-resolution spectrometer being completed by UC Davis and NASA Ames. A second generation instrument, HAWC+ (Highresolution Airborne Wideband Camera), is a 50-240 micron imager being upgraded at JPL to add polarimetry and new detectors developed at GSFC. SOFIA will continually update its instrument suite with new instrumentation, technology demonstration experiments and upgrades to the existing instrument suite. This paper details instrument capabilities and status as well as plans for future instrumentation, including the call for proposals for 3rd generation SOFIA science instruments.

FLITECAM↗

A qualitative and quantitative laser-based computer-aided flow visualization method

The experimental approach presented here offers a nonintrusive, qualitative and quantitative evaluation of full field flow patterns applicable in various geometries in a variety of fluids. This Full Flow Field Tracking (FFFT) Particle Image Velocimetry (PIV) technique, by means of particle tracers illuminated by a laser light sheet, offers an alternative to Laser Doppler Velocimetry (LDV), and intrusive systems such as Hot Wire/Film Anemometry. The method makes obtainable the flow patterns, and allows quantitative determination of the velocities, accelerations, and mass flows of an entire flow field. The method uses a computer based digitizing system attached through an imaging board to a low luminosity camera. A customized optical train allows the system to become a long distance microscope (LDM), allowing magnifications of areas of interest ranging up to 100 times. Presented in addition to the method itself, are studies in which the flow patterns and velocities were observed and evaluated in three distinct geometries, with three different working fluids. The first study involved pressure and flow analysis of a brush seal in oil. The next application involved studying the velocity and flow patterns in a cowl lip cooling passage of an air breathing aircraft engine using water as the working fluid. Finally, the method was extended to a study in air to examine the flows in a staggered pin arrangement located on one side of a branched duct.

Canacci, Victor A.↗

Image-Optimized Coronal Magnetic Field Models

We have reported previously on a new method we are developing for using image-based information to improve global coronal magnetic field models. In that work we presented early tests of the method which proved its capability to improve global models based on flawed synoptic magnetograms, given excellent constraints on the field in the model volume. In this follow-up paper we present the results of similar tests given field constraints of a nature that could realistically be obtained from quality white-light coronagraph images of the lower corona. We pay particular attention to difficulties associated with the line-of-sight projection of features outside of the assumed coronagraph image plane, and the effect on the outcome of the optimization of errors in localization of constraints. We find that substantial improvement in the model field can be achieved with this type of constraints, even when magnetic features in the images are located outside of the image plane.

Jones, Shaela I.↗

Synchronization of video recording and laser pulses including background light suppression

An apparatus for and a method of triggering a pulsed light source, in particular a laser light source, for predictable capture of the source by video equipment. A frame synchronization signal is derived from the video signal of a camera to trigger the laser and position the resulting laser light pulse in the appropriate field of the video frame and during the opening of the electronic shutter, if such shutter is included in the camera. Positioning of the laser pulse in the proper video field allows, after recording, for the viewing of the laser light image with a video monitor using the pause mode on a standard cassette-type VCR. This invention also allows for fine positioning of the laser pulse to fall within the electronic shutter opening. For cameras with externally controllable electronic shutters, the invention provides for background light suppression by increasing shutter speed during the frame in which the laser light image is captured. This results in the laser light appearing in one frame in which the background scene is suppressed with the laser light being uneffected, while in all other frames, the shutter speed is slower, allowing for the normal recording of the background scene. This invention also allows for arbitrary (manual or external) triggering of the laser with full video synchronization and background light suppression.

Kalshoven, Jr., James E.↗

Ambient and Cryogenic Alignment Verification and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a facility instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low- to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view using a commercial Micro Electro-Mechanical Systems (MEMS) Digital Micro-mirror Device (DMD) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the DMD field stop, and the spectrograph images the DMD onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and the ambient and cryogenic imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve to venfy alignment, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides further verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides spectral lines at 546.1 nm and 1550 nm, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard test results validate this prediction. We conclude with an instrument performance prediction for first light.

Connelly, Joseph A.↗