Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “levelized cost of water”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Levelized cost and carbon intensity of solar hydrogen production via water splitting using a scalable and intrinsically safe photocatalytic Z-scheme raceway system

Generating hydrogen from local energy resources such as solar or wind would unlock a low-carbon energy carrier that could be used to reduce greenhouse gas emissions in sectors such as industry and transportation. Yet, the allocation of new or existing power generation solely to hydrogen production remains contentious due to disputes regarding emissions accounting. Photocatalytic (PC) hydrogen production technologies offer a unique solution, as hydrogen is produced directly from solar energy and water, without the need for electricity generation. However, cost projections for all photocatalytic designs to date have suggested that they are not cost competitive compared to conventional electrolysis systems manufactured at scale. Herein, we offer the first illustrative benchmark of cost and carbon intensity of hydrogen produced in a type 2 “Z-scheme” photocatalytic reactor design, which employs suspended semiconducting nanoconductor particles organized into two stacked volumes in a raceway design. The “Z-scheme” system utilizes two separate photoabsorber particles, tuned to drive either the hydrogen evolution reaction or the oxygen evolution reaction individually, connected via a reversible, charge transfer redox couple in solution. Furthermore, the results suggest a highly competitive and scalable technology, that justifies further experimental validation and prototyping in the field.

Carbon↗

Quantification of energy and cost reduction from decreasing dissolved oxygen levels in full‐scale water resource recovery facilities

Abstract Aeration systems often lack the efficiency to maintain a desired residual dissolved oxygen (DO) concentration in the tank in part because little consideration is given to the dynamic daily and seasonal loading conditions. Although advanced aeration controllers exist, the majority of plants have DO set points typically based on common practice and literature values rather than site‐specific conditions, which can result in DO set points higher than those necessary to meet treatment objectives. DO set point reduction strategies have primarily been proposed through either static or dynamic simulations. In this study, the substantial improvements associated with DO set point reduction are demonstrated at full scale. A yearlong characterization of full‐scale aeration dynamics captured the effect of diurnal and seasonal fluctuations on oxygen transfer and energy demand and so facilitated the estimation of the potential savings of DO reduction strategies. Full‐scale validation provided direct evidence of DO reduction strategies inducing an overall enhancement of oxygen transfer efficiency along the different bioreactors, while confirming that energy savings as high as 20% were feasible. This study quantifies the influence of oxygen transfer efficiency on operating choices and site‐specific conditions (control strategy, loading conditions, and influent flow variability). Practitioner points We quantified the energy reduction and cost savings associated with a DO reduction in an aeration tank. For each 0.2 mg/L of DO decreased, the average power demand reduction per unit water treated exceeded 17%. Field measurements of dynamic alpha values eliminate the uncertainty in estimating aeration energy and cost savings from DO variations.

Pasini, Federico↗

WaterTAP3 Model Input Data for NAWI's Eight Source Water Baseline Analyses

This folder contains the input data for the WaterTAP3 model that was used for the eight NAWI (National Alliance for Water Innovation) source water baselines studies published in the Environmental Science and Technology special issue: Technology Baselines and Innovation Priorities for Water Treatment and Supply. There are also eight other separate DAMS submissions, one per source water, that include the model results for the published studies. In this data submission, all model inputs across the eight baselines are included. The data structure and content are described in a README.txt file. For more details on how to use the data in WaterTAP3 please refer to the model documentation and GitHub site found at "WaterTAP3 Github" linked in the submission resources.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design and full core fuel performance assessment of high burnup cores for 4-loop PWRs

Increasing the fuel discharge burnup of current light water reactors (LWRs) promises reductions in fuel cycle and/or operations costs. By assuming a constant core power density, the economic gain is enabled by better fuel utilization and/or an increased capacity factor. In this effort to investigate greater than 62 MWd/kgU maximum rod average burnup for 110+ kW/l core power density, two core designs have been developed for a standard 17x17, 193 fuel assemblies pressurized water reactor (PWR). The levelized unit cost methodology is employed to evaluate fuel cycle, operation and maintenance, and capital cost impacts and to examine the economic viability of both core design pathways. Core design and optimization are performed using the commercial STUDSVIK code package. Fuel performance analysis is realized in full core configuration via auditing FRAPCON4.1, FAST1.2, and the high-fidelity code BISON. To provide a realistic assessment, the core design process takes into consideration best practices in current PWR core design. It features acceptable performance in terms of various core design constraints on maximum allowable peaking and boron concentration. Gadolinia (Gd2O3) is used as a burnable poison with a maximum of 9 wt% concentration while feeding 89 or 77 fuel assemblies in a 3-batch refueling scheme. Full core fuel performance simulation, which allows for characterization of relevant fuel temperatures, plenum pressures, stresses, and strains, is performed with respect to two bounding burnup levels. Such performance is potentially licensable for the 18-month high burnup core (<68 MWd/kgU peak pin), while it is more challenging for the 24-month high burnup core design pathway (<75 MWd/kgU peak pin). Maximum rod plenum pressure is identified as the most limiting fuel performance parameter. Here, while the scope of the present study focuses on the steady-state plus overpower conditions, the acceptability of the new discharge burnup has to be further assessed by considering uncertainties and impacts under accident scenarios in the future.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Porous Membranes for Moisture Probe Protection (SR18024)

In the presence of contaminants, moisture probes can give false moisture readings and have shorter lifetimes. Absolute humidity probes are composed of porous, hygroscopic metallic oxide thin films (Al 2 O 3 ) coupled to electrodes (e.g. Au and Al). While these materials provide absolute humidity readings at low water levels at a relatively low cost, they are sensitive to the presence of contaminants, especially ammonia, due to its high hygroscopicity and ability to bind to the probe. Without frequent recalibration, especially in the presence of contaminants, the humidity levels are inaccurately reported due to measurement drift that occurs when the pores close, changing the impedance of the probe. The goal of this project was to improve the stability and reliability of these moisture probes by incorporating a molecular sieve into the probe to allow only the water to reach the sensor. Molecular sieves contain pores that allow molecule specific permeation. Two dimensional inorganic nanosheets (e.g. BN, MoO 2 , MoS 2 ) have recently been shown to behave as molecular sieves for water. Compared to zeolites, nanoporous materials have higher flux rates through the pores, leading to faster water permeation. Graphene oxide sheets have also been successfully employed for unimpeded water permeation; however, at lower humidity levels, the structure is unstable and the pores shrink, preventing the sieving of molecules. Compared to graphene oxide, sheets based off of inorganic materials, such as molybdenum, have been found to be more stable at lower humidity levels and have faster permeation rates. By creating a barrier in before the Al 2 O 3 sensor chip to prevent the permeation of contaminants into the probe, the lifetime of the probe will be extended. While the molybdenum sheets are a promising material for this application, their performance against ammonia and tritiated compounds have not yet been evaluated. This technology can be applied to other applications, including gas and liquid purification for environmental remediation, single molecule sensors, field effect transistors, and catalysts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Public water supply infrastructure extensification and diversification in surface waters is insufficient to meet future demands in Texas

The data were developed to evaluate the capacity of existing and potential new surface water supply infrastructure to meet projected public water demands across districts in Texas under multiple future socioeconomic and climate scenarios. The database integrates hydrologic, water quality, infrastructure, energy, cost, demographic, and demand-projection information for candidate surface water supply locations. Candidate sites include stream reaches, waterbodies, reservoir surplus locations, and potential new reservoir sites. Water availability is characterized using historical and projected flow conditions, while site suitability is evaluated using five indicators: Water Availability Index (WAI), Water Quality Index (WQI), Energy Requirement Index (ERI), Water Treatment Cost (WTC), and Water Infrastructure Cost (WIC). The datasets include statewide candidate-site information, district-level demand projections under Shared Socioeconomic Pathways (SSPs), runoff-based allocation constraints, climate-stress metrics, and optimization outputs evaluating alternative infrastructure planning strategies. Optimization results compare Business-as-Usual (BAU) and All Surface Water (AllSW) demand-management approaches under both scaled and fixed cost-cap strategies. Associated validation datasets provide district-level feasibility assessments, infrastructure selection outcomes, cost-cap utilization, demand satisfaction metrics, and constraint diagnostics. Additional datasets quantify projected changes in storage and flow conditions as well as water availability stress for both existing and newly selected intake locations under the SSP5 scenario for mid-century and late-century climate conditions. Together, these datasets support assessment of the extent to which surface-water infrastructure expansion and diversification strategies can satisfy future public water demands while accounting for hydrologic, economic, and planning constraints across Texas. Dataset(s) Description Dataset_preoptimization.xlsx Comprehensive pre-optimization dataset containing candidate water-supply sites and associated hydrologic, water-quality, infrastructure, climate, demographic, runoff, and demand-projection variables used as inputs to the optimization analyses. Includes variable descriptions and the full statewide candidate-site database. District_level_site_selection.zip - Compressed archive containing all SSP-specific district-level optimization result files MESIO_ssp1_results.xlsx District-level site selection results for SSP1 (MESIO). Includes variable descriptions, BAU and AllSW site-selection results under scaled and fixed cost strategies, and district-level validation diagnostics. MESID_ssp2_results.xlsx District-level site selection results for SSP2 (MESID). Includes variable descriptions, BAU and AllSW site-selection results under scaled and fixed cost strategies, and district-level validation diagnostics. LCMRD_ssp3_results.xlsx District-level site selection results for SSP3 (LCMRD). Includes variable descriptions, BAU and AllSW site-selection results under scaled and fixed cost strategies, and district-level validation diagnostics. IRDev-Low_ssp4l_results.xlsx District-level site selection results for SSP4-Low (IRDev-Low). Includes variable descriptions, BAU and AllSW site-selection results under scaled and fixed cost strategies, and district-level validation diagnostics. IRDev-High_ssp4h_results.xlsx District-level site selection results for SSP4-High (IRDev-High). Includes variable descriptions, BAU and AllSW site-selection results under scaled and fixed cost strategies, and district-level validation diagnostics. RSIM_ssp5_results.xlsx District-level site selection results for SSP5 (RSIM). Includes variable descriptions, BAU and AllSW site-selection results under scaled and fixed cost strategies, and district-level validation diagnostics. tx_hydrological_stress.xlsx Hydrological stress dataset for existing and newly selected intake locations. Includes projected mid-century and late-century changes, gain/loss classifications, planning strategy information, and accompanying variable descriptions. Also includes water-stress metrics derived from historical and projected low-flow conditions.

Okoye, Perpetua I. (ORCID:0000000215545033)↗

Reversible Losses in Proton Exchange Membrane Water Electrolysis

Lower anode catalyst loadings and higher current densities are essential to lowering the levelized cost of H 2 production via proton exchange membrane water electrolysis (PEMWE). However, these approaches can induce significant durability challenges. Here, we show that cell degradation can include large reversible voltage losses across a variety of conditions, including low loadings and high currents. Although there is limited published discussion of reversible voltage losses in PEMWE, we demonstrate that they are an important consideration in cell efficiency and durability. Understanding the mechanisms of reversible losses and developing mitigation strategies is therefore a key priority for enabling low-cost PEMWE.

08 HYDROGEN↗

Applying a Multisector Scenario Framework to Evaluate Past and Future Public Surface Water Supply Infrastructure Strategies in Texas

Datasets supporting the index model and scenario analysis used in evaluating surface water supply strategies across different water system types in Texas. These data underpin the scenario development and application of five key indicators: Water Availability Index (WAI), Water Quality Index (WQI), Energy Requirement Index (ERI), Water Treatment Cost (WTC), and Water Infrastructure Cost (WIC). The datasets are organized by system type—stream reaches (flowlines), waterbodies, and reservoirs—and include both raw and standardized index values. The integrated datasets also provide scenario classifications (original and adjusted) based on infrastructure and planning priorities, enabling comparison across Shared Socioeconomic Pathways (SSPs). Additional strategy-level data are included to support evaluation of state-level new reservoir projects in relation to cost and availability tradeoffs. Please refer to the README file provided in Files for more details. Descriptions of the datasets are provided below. Dataset(s) Descriptions Folder: Index_model_database.zip Subfolder: Stream_reach.zip Fl_wf.csv, Fl_wq.csv, Fl_er.csv, Fl_wf_wtcUV.csv, Fl_wf_wtcnoUV.csv, Fl_allfac_wic1.csv, Fl_allfac_wic2.csvDatasets for computing WAI, WQI, ERI, WTC, and WIC for surface water systems classified as stream reaches (flowlines). Subfolder: Waterbody.zip Wb_wf.csv, Wb_wq.csv, Wb_er.csv, Wb_wf_wtcUV.csv, Wb_wf_wtcnoUV.csv, Wb_allfac_wic1.csv, Wb_allfac_wic2.csvEquivalent index model datasets for waterbodies, reflecting hydrologic and infrastructure attributes specific to impounded natural systems. Subfolder: Reservoir.zip Rs_wf.csv, Rs_wq.csv, Rs_er.csv, Rs_wf_wtcUV.csv, Rs_wf_wtcnoUV.csv, Rs_allfac_wic1.csv, Rs_allfac_wic2.csvIndex model datasets specific to regulated reservoir systems, incorporating both resource indicators and cost parameters. Folder: Integrated data.zip combined_merged_data.csv, combined_merged_data_scenario.csvDatasets integrating index model indicators (both raw and scaled) with scenario classifications, including adjustments reflecting SSP-aligned transitions and planning shifts. Folder: Additional data.zip wai_supplystrat_wic_merged.csvCurated dataset capturing proposed major reservoir-based municipal water supply strategies in Texas. Integrates site-level planning data with estimated capital infrastructure costs and water availability scores for comparative assessment.

geospatial↗

Harnessing the Hydroelectric Potential of Engineered Drops (Final Technical Report)

The potential for low-head hydropower in the engineered drops in both federal and private irrigation system is well known and significant. The environmental and socio/recreational impacts of harnessing this renewable energy resource in man-made conduits are much less, and often insignificant, compared with comparable hydro-electric potential in natural water features on rivers, lakes, and streams. Yet, few new plants have been commissioned in more than two decades. Over the same time period, low head hydro installations in Germany have more than doubled. The challenge is in finding economical ways to harness the hydro-electric potential in the engineered drops, and efficiently deliver the power to the grid. The objectives of Percheron Power, LLC's (Percheron Power) Project were to design, develop, permit, and operate an innovative low-head hydro-electric generation facility on an existing engineered drop of a large irrigation canal system. The hydro-electric generation facility was designed to employ a new type of turbine and technology, called an Archimedes Hydrodynamic Screw (AHS), to harness the existing potential of the engineered drop. The goal was to demonstrate the new lower cost AHS technology system to federal agencies, irrigation districts and other system owners and to support further development of new small hydropower projects at previously marginal low-head sites in the U.S. The objective of this funding opportunity of the Department of Energy Water Power Technologies Office was to reduce the Levelized Cost of Energy (LCOE) for small hydropower to less than ${$}$0.07/kWh (${$}$70/MWh) to be competitive with existing base-load power sources such as coal-powered power plants.

13 HYDRO ENERGY↗

Electrolyzers in the System Advisor Model (SAM): A Techno-Economic Potential Study

A technoeconomic analysis of grid to low temperature electrolysis (Grid-LTE), photovoltaic to low temperature electrolysis (PV-LTE), concentrating solar power to high temperature electrolysis (CSP-HTSE) and a concentrating solar power with PV to high temperature electrolysis (CSP-PV-HTSE) centralized hydrogen production systems are analyzed to assess the economics of system and to provide a baseline for comparing these technologies against hydrogen production cost targets. A framework integrating the system advisor model (SAM) and US Department of Energy hydrogen production models (H2A) is developed to assess these systems. The hydrogen levelized cost given current and future assumptions for technology cost and performance is evaluated at optimal system configurations. The framework described in this report integrates SAM with H2A electrolyzer technologies and provides analysts a detailed technoeconomic method to analyze concentrating and photovoltaic solar technologies to produce energy that are directly coupled to LTE and HTSEs that use that energy to split water into hydrogen and oxygen. The baseline hydrogen levelized cost (HLCs) for the GRID-LTE, PV-LTE, CSP-HTSE, and CSP-PV-HTSE systems in Daggett, CA are 2.82, 3.86, 3.68, and 2.90 $\$$USD 2016/kg H2 and 2.50, 2.13, 2.84, 2.15 $\$$USD 2016/kg H2 in the 2020 and 2050 scenarios respectively. To achieve the $\$$2/kg H2 target in locations with excellent solar resources, cost parameters values aligned with aggressive R&D targets will need to be achieved for all the systems configurations. In Daggett, PV costs of $\$$0.68 /Wac or moderate ATB PV CAPEX projections result in HLCs of $\$$2 /kg H2. Similarly for PV-MSALT-HTSE systems, $\$$0.60 /Wac result in $\$$2/kg H2. For the MSALT-HTSE systems, better than aggressive 2050 ATB salt tower CAPEX projections would be needed to reach $\$$2/kg H2. Molten salt tower capital costs of $\$$2400/kW would enable $\$$2/kg H2 in 2050.

08 HYDROGEN↗

Measurement of free chlorine levels in water using potentiometric responses of biofilms and applications for monitoring and managing the quality of potable water

We report residual free chlorine is not monitored continuously at scale in drinking water distribution systems because existing real-time sensor technologies require frequent maintenance, cleaning, and calibration, which makes these products too costly to be used throughout a distribution system. As a result, current measurement approaches require manual sampling, which is not feasible for the consistent monitoring of free chlorine because chlorine concentrations vary significantly throughout pipeline distribution and over time and space. This research presents an alternative and cost-effective method of predicting free chlorine levels in drinking water using graphite electrodes coated with naturally grown microbial biofilms. This Microbial Potentiometric Sensor (MPS) array was installed in a Continuously Mixed Batch Reactor (CMBR), and drinking water containing variable free chlorine concentrations. The chlorine concentrations were introduced in a controlled manner, and the MPS signals were monitored over time. MPS signals were measured from the change in Open Circuit Potential (OCP) across the MPS array in real-time. An empirically derived relationship between the normalized change in OCP and free chlorine was established by fitting individual and average MPS data to a decaying exponential growth function in order to predict free chlorine levels. The results show that free chlorine can be predicted with reasonable accuracy, with model validation showing an average absolute error of ±0.09 ppm below 1.1 ppm and ±0.30 ppm between 1.1 and 2.7 ppm. However, the accuracy of predictions was reduced at higher free chlorine levels. The researchers conclude that MPS systems may benefit drinking water distribution systems by measuring free chlorine. These advantages of the MPS are especially pronounced in the developing world because this system is inexpensive and does not require routine maintenance or cleaning. The system relies on a naturally forming and regenerating biofilm and an inexpensive potentiometric meter to produce stable measurements.

54 ENVIRONMENTAL SCIENCES↗

Techno-economic analysis of offshore wind PEM water electrolysis for H 2 production

A model for producing hydrogen via offshore wind electrolysis was developed and the levelized costs of both energy and hydrogen were calculated. Here, this model calculated the cost of hydrogen produced by offshore wind and showed that the levelized cost of energy for hydrogen production and transportation to shore could be lower than for electricity transmission from offshore wind farms, using real wind data from a particular location. Therefore, direct coupling of the electrolysis system with offshore wind turbine is more advantageous than transmitting electricity to shore and then producing hydrogen via traditional electrolysis; the cost of hydrogen from offshore wind electrolysis is estimated to be $\$2.09$/kg, vs $\$3.86$/kg from traditional electrolysis using wind power.

08 HYDROGEN↗

Mining Nontraditional Water Sources for a Distributed Hydrogen Economy

Securing decarbonized economies for energy and commodities will require abundant and widely available green H 2 . Ubiquitous wastewaters and nontraditional water sources could potentially feed water electrolyzers to produce this green hydrogen without competing with drinking water sources. Herein, we show that the energy and costs of treating nontraditional water sources such as municipal wastewater, industrial and resource extraction wastewater, and seawater are negligible with respect to those for water electrolysis. We also illustrate that the potential hydrogen energy that could be mined from these sources is vast. Based on these findings, we evaluate the implications of small-scale, distributed water electrolysis using disperse nontraditional water sources. Techno-economic analysis and life cycle analysis reveal that the significant contribution of H 2 transportation to costs and CO 2 emissions results in an optimal levelized cost of hydrogen at small- to moderate-scale water electrolyzer size. The implications of utilizing nontraditional water sources and decentralized or stranded renewable energy for distributed water electrolysis are highlighted for several hydrogen energy storage and chemical feedstock applications. Finally, we discuss challenges and opportunities for mining H 2 from nontraditional water sources to achieve resilient and sustainable economies for water and energy.

54 ENVIRONMENTAL SCIENCES↗

Assessing hybrid vigour using the thermal sensitivity of physiological trade-offs in tiger salamanders

Hybridization between species affects biodiversity and population sustainability in numerous ways, many of which depend on the fitness of the hybrid relative to the parental species. Hybrids can exhibit fitter phenotypes compared to the parental lineages, and this ‘hybrid vigour’ can then lead to the extinction of one or both parental lines. In this study, we analysed the relationship between water loss and gas exchange to compare physiological performance among three tiger salamander genotypes—the native California tiger salamander (CTS), the invasive barred tiger salamanders (BTS) and CTS × BTS hybrids across multiple temperatures (13.5°C, 20.5°C and 23.5°C). We developed a new index of performance, the water-gas exchange ratio (WGER), which we define as the ratio of gas exchange to evaporative water loss (μL V O 2 /μL H 2 O). The ratio describes the ability of an organism to support energetically costly activities with high levels of gas exchange while simultaneously limiting water loss to lower desiccation risk. We used flow through respirometry to measure the thermal sensitivity of metabolic rate and resistance to water loss of each salamander genotype to compare indices of physiological performance. We found that temperature had a significant effect on metabolic rate and resistance to water loss, with both traits increasing as temperatures warmed. Across genotypes, we found that hybrids have a higher WGER than the native CTS, owing to a higher metabolic rate despite having a lower resistance to water loss. These results provide a greater insight into the physiological mechanisms driving hybrid vigour and offer a potential explanation for the rapid spread of salamander hybrids. More broadly, our introduction of the WGER may allow for species- or lineage-wide comparisons of physiological performance across changing environmental conditions, highlighting the insight that can be gleaned from multitrait analysis of organism performance.

59 BASIC BIOLOGICAL SCIENCES↗

One-Step Ahead Prediction of Thermal Mixing Tee Sensors with Long Short Term Memory (LSTM) Neural Networks

High-temperature advanced reactors under development, such as sodium fast reactors (SFR) and molten salt cooled reactors (MSCR), are expected to offer lower levelized cost of energy (LCOE) compared to existing light water reactor (LWR’s). In the existing light water reactors (LWR’s), operation and maintenance (O&M) expenses constitute the largest fraction of the total operating cost. Some of the O&M costs are related maintenance of sensors which can fail due to exposure to harsh environment in a reactor. The O&M costs of Advanced Reactor (AR)’s are expected to constitute a significant fraction of the total cost as well, because of high temperature and radiation level in AR are likely to cause material fatigue and premature failure of sensors and components. The O&M costs in AR’s could be reduced through integration of advanced informatics of performance-related sensors into a digital twin designed for reactor monitoring. For example, machine learning (ML) could be employed for real-time validation and correction of performance-related sensors, and reducing the number of performance-related physical sensor units through virtual sensing. As part of the effort, we investigate real-time validation of thermal hydraulic sensors through one-step ahead forecasting of sensor values using long short-term memory (LSTM) recurrent neural networks (RNN). The sensors are installed in a flow loop containing a thermal mixing tee, which is a common experimental model to study thermal fatigue in a thermal hydraulic loop. In addition, nonlinear transients generated in a thermal mixing tee constitute a good challenge data set for training and validation of ML algorithms. Sensors in this study include thermocouples, flow meters, and optical fibers for distributed temperature sensing. In one experiment, measurement data sets were obtained for a loop was filled with water, and in another experiment, measurements were performed on a loop filled with liquid metal Galinstan. We have also conducted preliminary investigation of one-step ahead prediction of fiber optics-based distributed temperature sensing with LSTM networks. In predicting fiber-based temperature measurements, we treated each gauge pitch of the fiber as an independent sensor. Accuracy of one-step ahead forecasting was estimated by calculating root mean square error (RMSE) for the test segment of time series of each sensor. RMSE’s for temperature sensors in water loop were, for the most part, lower than for the same sensors in Galinstan loop. The RMSE’s for flow meters were similar for both loops. The RMSE’s for distributed temperature measured with the fiber optic sensor were similar to those of the point sensors. Results of this study demonstrated the capability of LSTM one-step ahead forecasting with RMSE comparable to uncertainty in sensor measurements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Water Misting and Injection of Commercial Aircraft Engines to Reduce Airport NOx

This report provides the first high level look at system design, airplane performance, maintenance, and cost implications of using water misting and water injection technology in aircraft engines for takeoff and climb-out NOx emissions reduction. With an engine compressor inlet water misting rate of 2.2 percent water-to-air ratio, a 47 percent NOx reduction was calculated. Combustor water injection could achieve greater reductions of about 85 percent, but with some performance penalties. For the water misting system on days above 59 F, a fuel efficiency benefit of about 3.5 percent would be experienced. Reductions of up to 436 F in turbine inlet temperature were also estimated, which could lead to increased hot section life. A 0.61 db noise reduction will occur. A nominal airplane weight penalty of less than 360 lb (no water) was estimated for a 305 passenger airplane. The airplane system cost is initially estimated at $40.92 per takeoff giving an attractive NOx emissions reduction cost/benefit ratio of about $1,663/ton.

Daggett, David L.↗

Vegetable crop management with remote sensing

Repetitive aerial photography with color infrared (ACIR) and black-and-white infrared (B and WIR) films was taken of potato and tomato fields in southwest Florida during the spring season of 1975. Color differences observed in the photographs revealed different levels of soil moisture in the fields, improper ditch arrangements, poor stands of plants, and areas where late blight (Phytophthora infestans) (Mont.)d.By and early blight (Alternaria solani) (Ell. and Mart.) Jones and Grout. were defoliating potato plants. Photographs of fields before planting also indicated areas where excessive rock formations existed which would make field preparation costly. Preplanting photographs also pinpointed areas with different water table levels.

Blazquez, C. H.↗

Offshore Wind in the US Gulf of Mexico: Regional Economic Modeling and Site-Specific Analyses

The goal of this study is to assess offshore wind energy resources in the Gulf of Mexico (GOM) and to quantify its technical and economic potential in order to inform Federal and GOM state strategic energy planning over the next decade. The objectives are to: describe site-specific and regional benefits and challenges of deploying offshore wind in the GOM and discuss the current research to mitigate challenges; review and quantify the wind resource capacity and energy potential in the GOM region for each GOM state including state and federal waters, distance from shore, and water depth; perform geospatial regional economic assessments of levelized cost of energy (LCOE), levelized avoided cost of energy (LACE), and net value (Section 3.4.2); evaluate three representative hypothetical locations for site-specific analysis; perform a high-level assessment of local supporting infrastructure availability, including existing services (e.g., fabrication facilities, vessels, ports) and possible grid connection options; assess the regional economic impacts of a 600 megawatt (MW) offshore wind power plant installed at a representative site in the GOM.

17 WIND ENERGY↗