At least 55 records · Page 3

Production Facility Prototype Blower 1000 Hour Test Results V

Long duration operations tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks was not included in these tests. Thirteen long duration 500 to 1000 hour tests have been completed since the first test was performed in January of 2016. All thirteen long duration tests have proven successful in exposing preventable issues related to oil and helium leaks. All blower tests to this date have resulted in stable blower performance and consistency. A summary of the results for the end of the thirteenth test is included in this report. Complete details for the previous tests are shown in the reports, Production Facility Prototype Blower 1000 Hour Test Results, II, III, and IV.

36 MATERIALS SCIENCE↗

Hydrogen Component Leak Rate Quantification for System Risk and Reliability Assessment through QRA and PHM Frameworks: Preprint

The National Renewable Energy Laboratory's (NREL) Hydrogen Safety Research and Development (HSR&D) program in collaboration with the University of Maryland's Systems Risk and Reliability Analysis Laboratory (SyRRA) are working to improve reliability and reduce risk in hydrogen systems. This approach strives to use quantitative data on component leaks and failures, together with Prognosis and Health Management (PHM), and Quantitative Risk Assessment (QRA) to identify at-risk components, reduce component failures and downtime, and predict when components require maintenance. Hydrogen component failures increase facility maintenance cost, facility downtime, and reduce public acceptance of hydrogen technologies, ultimately increasing facility size and cost because of potentially overly conservative requirements. Leaks are a predominant failure mode for hydrogen components. However, uncertainties in the amount of hydrogen emitted from leaking components and the frequency of those failure events limit the understanding of the risks that they present under real-world operational conditions. NREL has deployed a test fixture, the Leak Rate Quantification Apparatus (LRQA), to quantify the mass flow rate of leaking gases from medium and high-pressure components that have failed while in service. Quantitative hydrogen leak rate data from this system could ultimately be used to better inform risk assessment and Regulation Codes and Standards (RCS). Parallel activity explores the use of PHM and QRA techniques to assess and reduce risk, thereby improving safety and reliability of hydrogen systems. The results of QRAs could further provide a systematic and science-based foundation for the design and implementation of RCS, as in the latest versions of the NFPA 2 code for gaseous hydrogen stations. Alternatively, data-driven techniques of PHM could provide new damage diagnosis and health-state prognosis tools. This research will help end users, station owners and operators, and regulatory bodies move towards risk-informed preventative maintenance versus emergency corrective maintenance, reducing cost and improving reliability. Predictive modelling of failures could improve safety and affect RCS requirements such as setback distances at liquid refuelling sites. The combination of leak rate quantification research, PHM, and QRA can lead to better informed models enabling data-based decision to be made for hydrogen system safety improvements.

codes and standards↗

Analysis of pressure test results of tube fittings for the potential application in cryo systems for helium leak rate reduction

Due to the nature of Helium, it is notoriously difficult to maintain a closed system without experiencing helium inventory loss through leakage in large tubing and piping runs. There are two standard fitting options readily available for piping and tubing assemblies, welded fittings or Swagelok ® . Welding is the best option for leak rate reduction, but more costly than Swagelok ® . A new style of fitting has come to the attention of BNL C-AD Cryo group, and a pressure test and leak rate analysis were performed to evaluate the viability of incorporating this new style fitting into current engineering design of warm helium tubing runs for the purpose of leak rate reduction.

43 PARTICLE ACCELERATORS↗

A Methodological Overview of Seismic Analysis for Nuclear Event Detection

Underground explosions generate potentially detectable signatures, including energy waves that travel through the Earth’s subsurface (i.e., seismic waves), low-frequency sound waves (i.e., infrasound and hydroacoustic waves), and radioactive gases and/or particles that might leak from the test cavity (if the event was nuclear). There can also be intelligence indicators of a test, such as observations of modified patterns of life and activity at a suspected test site. If all of these detectable signatures and intelligence indicators are present and self-consistent, then analysts have high confidence in classifying a signature generating event as an explosion. However, because only partial information about an event is likely to be available, determining whether an event was natural (e.g., an earthquake or landslide) or manmade (e.g., a chemical or nuclear explosion) is much more challenging. This primer describes how one category of event signatures—seismic signatures—can augment event analyses. While universities and government organizations have generated detailed technical descriptions of seismic analytic techniques, we seek to translate seismic event analysis for a broad, non-technical audience. When the geologic conditions near an event are well-characterized, seismic data can be used to calculate critical information, such as event location and depth, with relatively high accuracy. Moreover, specific features within seismic datasets can help determine whether an event was an explosion. However, a key challenge in seismic analysis is that geologic site conditions are often poorly characterized, complicating the ability to discern the true nature of the event. To overcome this challenge, geologists answer a series of questions (discussed in section 1) to guide seismic event analysis and determine the most probable nature of an event. As more information is gathered during each analytic step, confidence grows regarding the nature of the event. Section 2 addresses uncertainties in seismic analysis and the vital nature of high-fidelity geologic data for accurate seismic event analysis.

58 GEOSCIENCES↗

Predicting Rupture Pressure and Leak Rate of Alloy 600 Tubes with ODSCC and Comparing with Test Results (Technical Letter Report)

This report summarizes structural integrity work performed for the U.S. NRC that predicts the rupture pressure and leak rate of flawed steam generator (SG) tubes. The work includes pressure testing of straight tubes with lab-induced outer diameter stress corrosion cracks (ODSCC). Existing models for predicting rupture pressure and leak rate of straight tubes with well-defined, rectangular, electro-discharge-machined (EDM) flaws were modified and used to predict the measured rupture pressures and leak rates from straight tubes with ODSCC. Models previously developed for EDM notches in straight tubes were modified for ODSCC by using the equivalent rectangular crack (ERC) method.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development and experimental evaluation of new building air leakage measurement methods: measurement of interior air leaks and comparison to conventional methods

Building air leaks (both through exterior and interior surfaces) can have a significant impact on energy consumption, indoor air quality, fire safety, and moisture accumulation affecting structural durability. Blower door testing has been used to measure leaks in buildings, but commonly used testing methods do not directly measure interior leaks. In this paper, new testing methods (guarded interior test and zonal multipoint pressure testing method) are presented that directly measure these interior leaks, utilizing common blower door equipment for both single and multi-point testing. Furthermore, these new methods are compared to conventional methods in terms of the information provided, limitations and time/effort needed. In addition, building leak measurement results are analyzed to reveal a) coupling between power law model values (exponent and coefficient) for an ensemble of buildings, b) the error in using single point testing when estimating low pressure leakage, and c) how building power law models vary from low to high pressure ranges.

99 GENERAL AND MISCELLANEOUS↗

Predicting Rupture Pressure and Leak Rate of Alloy 600 U-bend Tubes with PWSCC and Comparing with Test Results (Technical Letter Report)

This report summarizes structural integrity work performed for the US NRC that predicts the structural integrity of steam generator (SG) tubes with flaws in the U-bend. The work covers model development and validation for U-bend tubes containing lab-induced primary water stress corrosion cracks (PWSCC). Limit load models for plastic collapse predicting ligament rupture pressure and leak rate of cracked U-bend tubes were developed and validated with pressure tests and finite element analyses (FEAs). Failure pressure and leak rate tests were conducted at room temperature on Alloy 600 U-bend tubes containing flaws located at various locations around the U-bend. Existing models for predicting structural integrity of straight tubes with well defined, rectangular, electro-discharge-machined (EDM) flaws were modified and used to predict the ligament rupture and unstable burst pressures as well as leak rates for the PWSCC flaws in the U-bend section.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Heat Exchanger Intensification Through Powder Processing and Enhanced Design (HIPPED)

High intensity, supercritical CO 2 heat exchangers capable of operating at temperatures between 800 and 1100 ˚C and pressures greater than 80 bar are considered a critical component for high efficiency power generation and a range of next-generation industrial processes. A novel heat exchanger concept was proposed in this project. The proposed concept involved a plate-type architecture with three-dimensional fins, called twisted s-shaped fins, that capitalize on additive manufacturing. Four manufacturing processes were studied to realize the complex envisioned design: press and sinter of metallic powders, directed energy deposition, laser powder bed fusion, and a novel powder bed process involving a photoreactive polymer called SEAM (scalable expeditious additive manufacturing), that later was developed at MSU. The team was able to manufacture subscale heat exchangers using laser powder bed fusion (LPBF) and SEAM. The team settled on using SEAM as a final manufacturing approach due to its very low cost. The SEAM-manufactured heat exchanger, however, when tested under pressure, exhibited leaks and the process still requires further development beyond the timeline of the project. To support the heat exchanger design and testing, the team developed a new high temperature flow loop allowing testing under high temperature and pressure. Computational modeling of the heat exchanger was also performed for the twisted s-shaped fins and the computations were validated with experimental data. The new twisted fins resulted in enhanced heat transfer and reduced pressure drop. To further minimize pressure drop in the plate heat exchanger, the team also developed a simplified model for flow maldistribution in the manifolds, providing a new tool for designers that eliminates the need for complex CFD calculations. A technoeconomic analysis was also developed to contrast SEAM with LPBF, this tool indicated that SEAM is several times less costly and offer significant promises as a rapid low cost additive manufacturing process for metallic systems.

30 DIRECT ENERGY CONVERSION↗

Fabrication and Preliminary Demonstration of Microwave Resonant Cavity Transducer Performance

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. We have developed an initial design for proof-of-principle testing of the flow sensor performance in microwave K-band. A cylindrical resonator prototype was fabricated from brass for initial tests in water. The cavity size is matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed, consisting of a piping Tee with bulkhead WR-42 microwave waveguide installed in leak-proof design. In the test article, the cylindrical cavity is positioned in the center of the pipe. A microwave waveguide circulator was installed in the setup to suppress microwave reflections at the cavity entrance. Preliminary spectral characterization of cavity spectral response was performed with microwave VNA. Applying mechanical pressure to cavity membrane showed a measurable shift in the microwave resonant frequency. We also investigate mechanical integrity of the flowmeter’s membrane through computer simulations. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Slow Strain Rate Testing of A537 Tank Wall Material

At Savannah River Site (SRS), High-Level Waste is stored in below-grade carbon steel tanks. This waste in part consists of sludge, salt cake, and/or supernate. Preparation of this waste for future processing involves dissolution of the salt cake layer. The salt dissolution process can create conditions that leave the carbon steel tanks susceptible to localized corrosion. The salt to be dissolved contains high concentrations of nitrate, that once released, create an environment that may be conducive to pitting corrosion and/or stress corrosion cracking (SCC) of carbon steel. The salt dissolution process also liberates interstitial liquid trapped between the salt crystals. This liquid is initially high in nitrite and hydroxide concentration. High pH and greater ratios of nitrite to nitrate act as inhibitors to minimize corrosion of carbon steel in high nitrate environments. However, as dissolution proceeds, the concentration of nitrate will increase, while the hydroxide and nitrite concentration of the interstitial liquid will deplete and become insufficient to prevent the onset of corrosion attack. Tank blending and the addition of inhibitors are used to ensure adequate concentrations of hydroxide and nitrite. However, this is not desirable during salt dissolution as it can reduce process efficiency and increase the amount of waste that needs processing. This testing program was designed to examine the risk of SCC associated with utilizing the pitting factor (PF) and nitrite/nitrate (NO 2 - /NO 3 - ) ratio limits for handling dissolved salt solutions at an elevated temperature in the carbon steel waste tanks. The previously identified limits are a PF of 1.2 and an NO 2 - /NO 3 - ratio of 0.15. The results indicate that as long as the NO 2 - /NO 3 - ratio exceeds 0.1 and the PF is above approximately 0.8, there is a discernible safety margin between the open circuit potential (OCP) and the critical cracking potential (CCP) observed during applied potential testing. However, this margin, defined by the difference between the OCP and CCP, is relatively narrow, ranging from 0.1 to 0.25 volts. This small margin raises concerns about potential shifts in OCP during waste retrieval operations, which could inadvertently increase the risk of SCC if the OCP approaches or exceeds the CCP. These results confirm that dissolved salt solutions provide a potent chemistry that, under certain conditions, makes carbon steel susceptible to SCC. The next question to consider is the influence these results have on decisions for storage and retrieval of waste from the tanks. For Type III/IIIA waste tanks, the risk of SCC remains very low. First, and most importantly, the post-weld stress relief of the tanks has reduced the residual stress near the welds. Thus, without the stress component, SCC risk is minimized. The material of construction (A537 Carbon steel) for the Type III/IIIA tanks is superior to the steel in its resistance to SCC than the steel that was utilized for the Type I, II, and IV tanks (A285 carbon steel). From a chemistry control standpoint for a Type III/IIIA tank directly involved with handling dissolved salt solutions, the PF and NO 2 - /NO 3 - ratio limits may be utilized wherein chemistry control provides an extra layer of defense against SCC. Chemistry control for a Type III/IIIA tank minimizes the risk for a tank that may receive the dissolved salt solution, particularly if that tank is a Type I, II, or IV waste tank. On the other hand, if the dissolved salt solution is handled by a Type I, II, or IV waste tank the risk of SCC is real. The potent chemistry, absence of stress relief, and inferior material result in a condition that is conducive to cracking. Efforts should be made to either avoid transferring waste that may not meet the PF and NO 2 - /NO 3 - ratio criteria to one of these tanks or if it is unavoidable, take measures to minimize the consequences of a leak. As shown by these tests, even if the PF and NO 2 - /NO 3 - ratio criteria are met, there is a risk that the tank potential may be disturbed in the positive direction and the risk of SCC increase.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantification of air leakage paths: a comparison of airflow and acoustic measurements

Today, the fan pressurization method is the most frequently used method to evaluate a building's airtightness. However, the localization and quantification of leaks remain difficult. In this paper, an acoustic method is introduced to estimate the leakage size of single leaks. Acoustic and airflow measurements were conducted and compared in laboratory tests within the same boundary conditions. This work aims to investigate if various leak sizes can be predicted using acoustic measurement methods. The test apparatus consists of two chambers, separated by a test wall. This wall represents a single characteristic air leakage path. Various types of wall structures with different slit geometries, wall thicknesses, and insulation materials were investigated. The acoustic measurements were performed with a sound source placed in one chamber and ultrasonic microphones located in both chambers. These results were compared to measured airflows through the test wall to provide estimates of uncertainty in the acoustic approach, which indicate a linear trend. Finally, these laboratory measurements were compared to the same measurements at a real office building. Finally, although the acoustic measurement uncertainty is still significant (greater than +/- 50%), the acoustic method has the potential to give an order of magnitude of single leak sizes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Software Verification Toolkit (SVT): Survey on Available Software Verification Tools and Future Direction

Writing software is difficult. However, writing complex, well tested and designed, and functionally correct software is incredibly difficult. An entire field of study is devoted to the validation and verification of software to address this problem, and in this paper we analyze the landscape of currently available third party software. We have divided our analyses into three separate subsections with regards to software validation: formal methods, static analysis, and test generation. Formal verification is the most complex method in which to validate software correctness, but also the most thorough as it truly validates the mathematical validity of the source code. Static analysis generally is relegated to abstract syntax tree traversal techniques to find errors related to faulty software such as memory leaks or stack overflow issues. Automatic test generation is similar in implementation to static analysis, but pushes a bit further in verifying the boundedness of function inputs and outputs with regards to annotated or parsed criteria. The crux of this report is to analyze and describe the software tools that implement these techniques to validate and verify software. Pros and cons related to installation, utilization, and capabilities of the frameworks are described, and reproducible examples are provided with a focus on usability. The initial survey concluded that the most interesting tools of note are Z3, Isabelle/HOL, and TLA+ with regards to formal verification; and Infer, Frama-C, and SonarQube with regards to static analysis. With these tools in mind, a final conjecture is provided that describes future avenues of utilizing these tools for developing a verification framework to assist in validating existing software at Sandia National Laboratories.

97 MATHEMATICS AND COMPUTING↗

SULI Report - Development of a Molten Salt Circulation Loop for in-situ Spectroscopy

This project supports the development of real time optical monitoring capabilities for molten salt reactor (MSR) environments by designing, testing, and refining a molten salt circulation loop suitable for combined laser induced breakdown spectroscopy (LIBS) and ultraviolet visible (UV Vis) absorption measurements. Online spectroscopic monitoring is increasingly important for nuclear safeguards, corrosion tracking, and material accountancy, yet MSR process fluids present substantial challenges due to their chemical complexity and hazards such as high temperatures and radiation. To address these needs, this work focuses on Phase I, the development of a room temperature aqueous circulation loop that serves as a surrogate platform for evaluating flow behavior, optical access, and component performance prior to high temperature salt operation. Initial testing identified several practical issues—including leaks, obstructions, and two-phase flow through the absorption cell—that were systematically resolved through hardware replacement, flow path redesign, and venturi pressure optimization. Relocating the flow cell upstream of the primary venturi enabled periods of stable single-phase flow, demonstrating the feasibility of integrating optical diagnostics into a circulation system. The results of Phase I provide essential design insight for Phase II, which will incorporate furnace compatible materials and LiCl KCl eutectic salt. Completion of the molten salt system will deliver a reusable testbed for evaluating multimodal spectroscopic techniques, advancing nondestructive, real time monitoring tools for future MSR and nuclear fuel cycle applications.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Evaluation of NETL’s Self-Healing Metallic Coating for Internal Corrosion Protection of Natural Gas Pipelines: Field Test

Steel pipelines are a safe, reliable, and affordable way to transport natural gas. However, the presence of impurities (e.g., water, carbon dioxide, and hydrogen sulfide) in the natural gas can cause internal corrosion, which can lead to pipeline leaks and failure. This paper reports on field tests of an innovative self-healing, corrosion-resistant, metallic coating developed at the National Energy Technology Laboratory (NETL) for protecting the interior surfaces of pipelines.

carbon dioxide (CO2)↗

Advancing Building Air Leakage Measurement and Modeling: Measurement of Interior Air Leaks, Experimental Comparison to Conventional Methods, and Building Modeling Characteristics

This report, Advancing Building Air Leakage Measurement and Modeling: Measurement of Interior Air Leaks, Experimental Comparison to Conventional Methods, and Building Modeling Characteristics, developed two new building air leakage measurement methods, experimentally evaluated the performance in comparison to conventional methods, experimentally evaluated the behavior of leaks for specific crack structures, and identified testing constraints and model implications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Leak-tight crack repair for 304L stainless steel using friction surfacing

Here, friction surfacing (FS) was investigated as a method for sealing 50 μm wide thru-cracks in 3-mm-thick 304L stainless steel (304L) plate. Friction surfacing was performed using two sizes of 304L consumable rod, with diameters of 9.52 mm and 12.7 mm, on two substrate conditions (clean and oxidized). Friction surfacing was able to deposit a 600 μm thick coating and repair cracks to a depth of 100 μm - 200 μm below the original surface, when using the 12.7-mm-diameter consumable rod for both substrate conditions. Helium leak rates of 10 -10 atm-cc/s were achieved on crack repairs, designating them as leak-tight by the ANSI N14.5 standard. Optical and scanning electron microscopy were used to investigate the coating microstructure and bond interfaces. In this study, the 12.7-mm-diameter rod performed better with disruption of the oxide layer on the oxidized substrate and providing a more homogenous coating. Mechanical properties of the coated samples were evaluated by performing micro-indentation, tensile, bending, and adhesion testing. Higher hardness in the coatings was observed due to the fine equiaxed grains resulting from dynamic recrystallization. Complete consolidation of plastically deformed material on the substrate and a strong diffusion bond across the interface was observed. This was reflected in tensile and bending properties of the FS coatings being comparable to those of uncoated specimen. No delamination of the FS coating was observed during adhesion testing. The results demonstrate that friction surfacing is a viable option to seal cracks in stainless steels.

36 MATERIALS SCIENCE↗

Solid-State Mixed-Potential Electrochemical Sensors for Natural Gas Leak Detection and Quality Control (Final Technical Report)

Mitigation of methane emissions are a critical factor to limiting the impact of the natural gas industry on global climate change. Throughout the period of 2020-2024, the University of New Mexico and its commercialization partner and subcontractor, SensorComm Technologies, Inc. (SCT), have worked together to develop a low-cost Artificial Intelligence (AI)-driven Internet of Things (IoT)-based multi-gas sensor platform for methane emissions detection. In the final year of the project, we extended this work to include hydrogen detection in support of a transition to a hydrogen economy where hydrogen could be transported through existing natural gas infrastructure. Mixed potential electrochemical sensors were first prototyped by ceramic additive manufacturing and then transitioned to conventional ceramic manufacturing tape casting and screen-printing technologies in preparation for mass production. Demonstrated limits of detection of 5 ppm of methane in natural gas and 1 ppm of hydrogen were measured. These limits of detection are among the lowest of solid-state electrochemical sensors that have been reported in the literature or available in the industry. Machine learning algorithms were developed to identify natural gas mixtures with > 98% accuracy level and quantify methane concentrations at 97% accuracy. The presence of hydrogen could also be identified, and its concentration quantified at these accuracy levels. These algorithms were optimized for running on portable computing hardware which enabled > 1 Hz processing rates. A portable packaged IoT system was integrated with the electrochemical sensor in collaboration with SCT. The package consists of readout electronics with < 1 mV resolution, sensor temperature control, and data transmission over cellular wireless and/or Wi-Fi networks. Field testing was performed in two rounds at Colorado State University’s Methane Emissions Technology Evaluation Center (CSU METEC). The first round of testing demonstrated successful measurements of methane from an underground natural gas leak of 20 standard liters per minute (SLPM), which agreed with previously published literature using more sophisticated and expensive analytical equipment. The second round of testing showed that an above ground leak of 2 SLPM of hydrogen could be detected at 32 ft. This project has resulted in six published peer reviewed journal articles, over ten presentations at professional conferences, and one full patent application filed in 2023. Future work on this project includes increased sensitivity, higher production yields, and applications in the hydrogen safety and flare emissions monitoring spaces.

03 NATURAL GAS↗

Leak Detection and Sensor Importance Within a Solvent Extraction Process Abstract

In anticipation of the Special Nuclear Material test bed (Beartooth), Idaho National Laboratory has developed a smaller, multi-sensor system for analyzing the solvent extraction process. These systems will allow for research into nuclear fuel processing operations. The multi-sensor system consists of a row of centrifugal contactors and allows for measurement sources that are not traditionally used in the solvent extraction process to be explored including temperature, vibration, acoustics, pH, color, flow, and motor current. Currently, the solvent extraction process is very labor intensive and requires vigilant operators to identify the occurrence of leaks, which can be common during startup or after any change to the system. This study aims to locate leaks using non-traditional measurement sources then to identify which signals were of greatest importance in making this classification using Local Interpretable Model-agnostic Explanations. These results can be used to help solvent extraction process operators detect leaks and to inform future test beds designers to which sensors contain relevant, actionable information in this scenario.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗