Vibration characteristics of a laser heterodyne spectrometer tunable diode laser system using a mechanical cooler platform

The Langley Research Center redesigned the cooler test bed hardware for the refrigerator for the purpose of isolating the tunable diode laser (TDL) from the cold tip in a laser heterodyne spectrometer system. Deflection in the lateral and vertical directions were managed on the cold tip and on the TDL. Measurements were analyzed over the frequency range of 0.100 Hz. The results show that the TDL responds approximately one order of magnitude less than that of the cold tip. The redesign of the system provided for adequately isolating the TDL for future operation.

Catherines, J. J.

Remote atmospheric sensing with an airborne laser absorption spectrometer

A laser absorption spectrometer, using an infrared laser transmitter and a heterodyne radiometer, can be used from an aircraft or spacecraft to measure altitude profiles of air pollutants and other atmospheric constituents. The technique involves measurement of differential absorption at several wavelengths, using the diffusely reflecting earth's surface to provide a return signal. The pressure broadening of absorption lines allows one to discriminate between high and low altitude absorbers. Application of the technique to measurements of ozone, nitric oxide, and water vapor are presented. CO2 and CO lasers are considered as transmitters. The discussion includes altitude resolution limitations, atmospheric temperature dependence, and frequency stability requirements of the instrument.

Menzies, R. T.

Remote atmospheric sensing with an airborne laser absorption spectrometer

A laser absorption spectrometer, using an IR laser transmitter and a heterodyne radiometer, can be used from an aircraft or spacecraft to measure altitude profiles of air pollutants and other atmospheric constituents. The technique involves measurement of differential absorption at several wavelengths, using the diffusely reflecting earth's surface to provide a return signal. The pressure broadening of absorption lines allows one to discriminate between high and low altitude absorbers. Application of the technique to measurements of ozone, nitric oxide, and water vapor are presented. CO2 and CO lasers are considered as transmitters. The discussion includes altitude resolution limitations, atmospheric temperature dependence, and frequency stability requirements of the instrument.

Menzies, R. T.

Laser particulate spectrometer

Hybrid laser scattering and extinction technique measures particle diameters from 0.8 to 2.75 micrometers and speeds from 0.2 to 20 m/s. Operating pressures range from ambient to ultra-high vacuum, and temperatures range from 77 to 300 K. Potential applications include air pollution, clean room, and particle size monitoring.

Boyd, B. A.

Development and performance of a laser heterodyne spectrometer using tunable semiconductor lasers as local oscillators

A diode laser based IR heterodyne spectrometer for laboratory and field use was developed for high efficiency operation between 7.5 and 8.5 microns. The local oscillator is a PbSSe tunable diode laser kept continuously at operating temperatures of 12-60 K using a closed cycle cooler. The laser output frequency is controlled and stabilized using a high precision diode current supply, constant temperature controller, and a shock isolator mounted between the refrigerator cold tip and the diode mount. Single laser modes are selected by a grating placed in the local oscillator beam. The system employs reflecting optics throughout to minimize losses from internal reflection and absorption, and to eliminate chromatic effects. Spectral analysis of the diode laser output between 0 and 1 GHz reveals excess noise at many diode current settings, which limits the infrared spectral regions over which useful heterodyne operation can be achieved. System performance has been studied by making heterodyne measurements of etalon fringes and several Freon 13 (CF3Cl) absorption lines against a laboratory blackbody source. Preliminary field tests have also been performed using the Sun as a source.

Glenar, D.

Laser mass spectrometer

Development of time of flight mass spectrometer using laser powered vaporization source is discussed. Operation of equipment to measure thermal velocities of individual mass species is described. Illustration of test equipment installation and detailed line drawing of ion producing equipment are provided.

Lincoln, K. A.

Diode-Laser-Based Spectrometer for Sensing Gases

A diode-laser-based spectrometer has been developed for measuring concentrations of gases and is intended particularly for use in analyzing and monitoring combustion processes under microgravitational conditions in a drop tower or a spacecraft. This instrument is also well suited for use on Earth in combustion experiments and for such related purposes as fire-safety monitoring and monitoring toxic and flammable gases in industrial settings. Of the gas-sensing spectrometers available prior to the development of this instrument, those that were sensitive enough for measuring the combustion gases of interest were too large, required critical optical alignments, used far too much electrical power, and were insufficiently rugged for use under the severe conditions of spacecraft launch and space flight. In contrast, the present instrument is compact, consumes relatively little power, and is rugged enough to withstand launch vibrations and space flight. In addition, this instrument is characterized by long-term stability, accuracy, and reliability. The diode laser in this spectrometer is operated in a wavelength-modulation mode. Different gases to be measured can be selected by changing modular laser units. The operation of the laser is controlled by customized, low-power electronic circuitry built around a digital signal-processor board. This customized circuitry also performs acquisition and analysis of data, controls communications, and manages errors.

Silver, Joel A.

Atmospheric solar absorption measurements in the 9-11 micron region using a diode laser heterodyne spectrometer

A tunable diode laser heterodyne radiometer was developed for ground based measurements of atmospheric solar absorption spectra in the 9 to 12 micron spectral range. The performance and operating characteristics of this tunable infrared heterodyne radiometer (TIHR) is discussed along with recently measured heterodyne solar absorption spectra in the 10 to 11 micron spectral region.

Harward, C. N.

Atmospheric solar absorption measurements in the 9 to 11 mu m region using a diode laser heterodyne spectrometer

A tunable diode laser heterodyne radiometer was developed for ground-based measurements of atmospheric solar absorption spectra in the 8 to 12 microns spectral range. The performance and operating characteristics of this Tunable Infrared Heterodyne Radiometer (TIHR) are discussed along with atmospheric solar absorption spectra of HNO3, O3, CO2, and H2O in the 9 to 11 microns spectral region.

Harward, C. N.

Tunable diode laser IR spectrometer for in situ measurements of the gas phase composition and particle size distribution of Titan's atmosphere

A new instrument, the Probe Infrared Laser Spectrometer (PIRLS), is described for in situ sensing of the gas composition and particle size distribution of Titan's atmosphere on the NASA/ESA Cassini mission. For gas composition measurements, several narrow-band (0.0001/cm) tunable lead-salt diode lasers operating near 80 K at selected mid-IR wavelengths are directed over a path length defined by a small reflector extending over the edge of the probe spacecraft platform; volume mixing ratios of 10 to the -9th should be measurable for several species of interest. A cloud-particle-size spectrometer using a diode laser source at 780 nm shares the optical path and deployed reflector; a combination of imaging and light scattering techniques is used to determine sizes of haze and cloud particles and their number density as a function of altitude.

Webster, Christopher R.

Laser absorption spectrometer - Remote measurement of tropospheric ozone

The laser absorption spectrometer (LAS) is an airborne instrument able to perform remote measurement of trace atmospheric gases. The instrument uses a pair of carbon dioxide laser-heterodyne receiver systems that are directed downward from an airplane and determines gas concentration by the differential absorption method. Configured to measure tropospheric ozone, the LAS has been used in conjunction with another instrumented aircraft to test the accuracy of this method of measurement. A complete description of the instrument is presented, and the results of extensive flight testing are summarized.

Shumate, M. S.