Engineering PapersSearch

SEARCH · Engineering Papers

Results for “large loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Purpose, Design, and Analysis of the NSTX-U Centerstack Casing Lateral Support Shims

The National Spherical Torus Experiment Upgrade (NSTX-U) centerstack casing surrounds the central magnet core of NSTXU. It provides the inner vacuum boundary of the plasma chamber and supports the radially inboard plasma facing components lining the plasma chamber. The casing is supported like a cantilever, fixed at the lower flange by a connection to the TF Bundle through a G-10 ring. It is flexibly supported at the top by bellows, and insulated shims intended to react the largest part of the inventory of the disruption loads at the upper support, thereby protecting the upper and lower connections from excessive loads. A large part of the qualification of the casing and tiles requires addressing and quantifying disruption loads. These have been estimated based on extensions of the behavior of NSTX during its run period roughly 15 years ago. Structural qualification of the Upgrade used these estimates of the loading as input to calculations to demonstrate adequacy for a “most probable” disruption. The estimates are included in a requirements document to guide conservative design of all components loaded by disruptions. However, the changes made for the upgrade made the extrapolation of disruption behavior uncertain. Disruptions include axisymmetric loading from axisymmetric currents induced in the vessel shells. In addition, more complex currents called Halo currents are a result of plasma poloidal currents impinging on the casing. The halo currents add another layer of uncertain behavior and net lateral loading to the casing. As a result, NSTX-U is equipped with a number of instruments intended to assess the nature and severity of disruptions. The casing shims are required for lateral support of the casing, but these have also been converted to load cells to provide another measure of the magnitude of symmetric and asymmetric loading. Some of the logic in the development of the requirements document are presented. Electromagnetic analysis of axisymmetric and halo loading is described. Global simulations of the casing transient dynamic response, and local analysis and testing of the shim/load cell are included. The shim load cells and other instrumentation will be an important guide in planning NSTX-U experiments beyond its next run period expected in late 2026 or early 2027.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Energy characteristics of multi-chiller load distribution algorithms in a large office building

Here, this study evaluates the energy efficiency of multi-chiller systems in large office buildings, focusing on their optimization across various climate zones as defined by ASHRAE. Using EnergyPlus for simulations, the research examines five different load distribution algorithms in multi-chiller systems that range from one to ten chillers, aiming to understand their effectiveness in 15 distinct climate zones. The primary objectives of the study include identifying the energy efficiency of multi-chiller systems in each climate zone, determining the appropriate number of chillers for each zone, and evaluating the performance of the load distribution algorithms. Based on the U.S. Department of Energy’s commercial building model, the results suggest that multi-chiller systems can significantly reduce cooling energy consumption in various climates. Among the algorithms evaluated, the Sequential Uniform Part Load Ratio (SUPLR) algorithm demonstrates notable efficiency, especially in the 4A climate zone (Baltimore), where it achieves substantial energy savings. Applying the SUPLR algorithm in a multi-chiller setup with four chillers in this zone leads to an estimated 24.5 % reduction in energy usage, equivalent to 183 MW annually. The research indicates that a range of 3 to 5 chillers is typically optimal for most climate zones. In-depth analysis in the 4A climate zone highlights the importance of minimizing operation hours at low Part Load Ratios (PLR) to ensure that chillers operate at a high Coefficient of Performance (COP). This strategy underscores the potential of well-designed multi-chiller systems to reduce cooling energy demand, particularly in climates with transitional seasons. This study provides an overview of the energy-saving potential of multi-chiller systems, applicable across a variety of climatic scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Leveraging reVeal for Data Center Siting [Slides]

reVeal (the reV Extension for Analyzing Loads) is an open-source, flexible geospatial platform designed to characterize site suitability, with the goal of informing spatial downscaling and disaggregation of large-scale load projections.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Integration of a grey-box refrigerated case model in EnergyPlus via Python plugin

Commercial buildings, in particular grocery stores (due mainly to their large refrigeration load), provide opportunities for energy cost reductions. Grocery stores could offer substantial load flexibility to the power grid through participation in demand response programs because of their usage patterns and relatively high energy intensity. This load flexibility could come from modifying the control of heating, ventilation, and air conditioning (HVAC) systems, refrigeration systems, or both. Although estimation of the HVAC system’s load flexibility potential is relatively targeted in the literature, estimating load flexibility of refrigeration systems is nascent and has been a challenge, in part because of the lack of proper simulation tools that capture the dynamics in the refrigeration cases. The existing refrigerated case model within EnergyPlus, a whole building energy simulation program, assumes a constant case temperature throughout the simulation period and does not explicitly model the cycling of the compressor serving the refrigerated case. In addition, it does not encompass modeling of temperatures of the product inside the refrigerated case. This difference between modeled and actual operation can be a barrier to the development of demand control algorithm and accurate analysis of load flexibility potential. In this paper, we present a grey-box model for modeling refrigerated cases in grocery stores, which include medium temperature and low temperature. Four cases are modeled; two are low-temperature closed cases and two are medium-temperature cases with one closed and one open. Data from an experimental facility are used to train and test the models. Results demonstrate the efficacy of the grey-box models in predicting the temperatures. This model is integrated into EnergyPlus to capture the dynamic effects of case temperature on the environment and enhance the calculation of sensible and latent heat exchange with the environment (case credits). These enhancements can be leveraged more broadly to model advanced refrigeration controls such as defrost, develop and test unique algorithms that could affect refrigeration interactions with HVAC, and refine store design for any commercial building with refrigeration.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Experimental Observation of a New Attenuation Mechanism in hcp ‐Metals That May Operate in the Earth's Inner Core

Abstract Seismic observations show the Earth's inner core has significant and unexplained variation in seismic attenuation with position, depth and direction. Interpreting these observations is difficult without knowledge of the visco‐ or anelastic dissipation processes active in iron under inner core conditions. Here, a previously unconsidered attenuation mechanism is observed in zinc, a low pressure analog ofhcp‐iron, during small strain sinusoidal deformation experiments. The experiments were performed in a deformation‐DIA combined with X‐radiography, at seismic frequencies (∼0.003–0.1 Hz), high pressure and temperatures up to ∼80% of melting temperature. Significant dissipation (0.077 ≤ Q −1 (ω) ≤ 0.488) is observed along with frequency dependent softening of zinc's Young's modulus and an extremely small activation energy for creep (⩽7 kJ mol −1 ). In addition, during sinusoidal deformation the original microstructure is replaced by one with a reduced dislocation density and small, uniform, grain size. This combination of behavior collectively reflects a mode of deformation called “internal stress superplasticity”; this deformation mechanism is unique to anisotropic materials and activated by cyclic loading generating large internal stresses. Here we observe a new form of internal stress superplasticity, which we name as “elastic strain mismatch superplasticity.” In it the large stresses are caused by the compressional anisotropy. If this mechanism is also active inhcp‐iron and the Earth's inner‐core it will be a contributor to inner‐core observed seismic attenuation and constrain the maximum inner‐core grain‐size to ≲10 km.

Geochemistry & Geophysics

Future Industrial Demand: Large, Elastic, and Concentrated [Guest Editorial]

Here, the future industrial demand on the grid is expected to be large, price sensitive, and concentrated. Grid industrial demand increasingly encompasses a new customer type defined as a large flexible load (LFL). This LFL type defines customers with consumption that responds quickly to price or other incentives without interrupting their core business process, such cryptocurrency mining. This customer type can often ramp up and down quickly, which across an entire industry can mean gigawatts of power within a few minutes. In addition to these price-sensitive loads, significant growth is also anticipated in sectors like manufacturing, data centers, and electrification of transportation and buildings.

Mukherjee, Srijib [Oak Ridge National Laboratory (

Simulation-Based Analysis of Feeder Operation with Different PV Smart Inverter Functions on an Actual Distribution System: Preprint

High penetration of photovoltaics (PV) in distribution feeders can cause problems, such as overvoltage, reverse power flow, and large net load changes. Traditional voltage regulation devices, such as capacitors and voltage regulators, can solve some of these problems but might have some delays. Today, smart inverters are gradually being used to provide voltage regulation and frequency support in distribution systems. Different smart inverter settings have been recommended in various rules and standards; however, the potential benefits and their impacts on distribution system operation are not well compared and studied. This paper presents a comparison of different smart inverter settings as applied to a distribution system. An actual feeder model from San Diego Gas & Electric Company is used to conduct the simulation. Additionally, a load disaggregation method is proposed to disaggregate the load and PV profile for each load location using advanced metering infrastructure net load measurements. Then, different smart inverter settings are applied to the PV systems in the feeder, and the simulation results are compared. The results show that the implementation of specific functions of smart inverters can reduce voltage exceedances, and the utility can determine the specific inverter setting based on its operational requirements.

distribution system

Slashing Platinum Group Metals (PGM) in Catalytic Converters: An Atoms-to-Autos Approach

Platinum group metals (PGMs) are used in three-way catalysts (TWCs) for stoichiometric gasoline engine vehicles to simultaneously convert carbon monoxide, hydrocarbons, and nitrogen oxides into nitrogen, carbon dioxide and water. For US light duty gasoline vehicles, about 3-8 grams of PGMs are used in each catalytic converter system and the PGM loading is expected to increase for future vehicles, driven by increasingly stringent emissions standards, potentially lower engine exhaust temperatures, and higher emission control system durability requirements. The technical necessity for the current high PGM loadings is largely driven by: 1) poor atomic efficiency (or metal dispersion) of PGMs on catalyst supports with the current synthesis approaches, and 2) severe deactivation of unstable PGM nanoparticles in high temperature engine exhaust. Therefore, the project team will develop catalyst technologies that not only maximize the PGM atom efficiency and intrinsic activity in the fresh state, but also maintain the benefits during aging with extended exposure in engine exhaust.

36 MATERIALS SCIENCE

Use Case Specification

Over the past three years, the Use Case Specification project has provided scenarios that have driven the development of key E-COMP capabilities and demonstrated their application to problems that the electric power industry is facing. These scenarios have provided the basis for which each Thrust has performed technical work, tying together E-COMP work under a common umbrella. Documented in this report is a summary of the background, motivations, and work – completed or proposed – under the three E-COMP use cases pursued to date: Offshore Wind, Remote Communities on the Olympic Peninsula, and Large Electric Loads.

24 POWER TRANSMISSION AND DISTRIBUTION

Data Center Power Systems: Architectures, Impact on Grid Reliability, Modeling Considerations, and Megawatt-Scale Hardware Testing [Slides]

This slide deck describes typical power systems of large datacenters along with reliability problems to bulk power systems from large-scale integration of datacenters. The slide deck covers the architecture of datacenter power systems, different power electronic converters used inside datacenters, their operation modes, and R&Dopportunities in maintaining grid stability.

24 POWER TRANSMISSION AND DISTRIBUTION

Bridging the Gap for Powering Data Centers

The rapid expansion of data centers, primarily driven by artificial intelligence, is outpacing the adaptability of the U.S. electric grid. This report, developed by Idaho National Laboratory (INL) , presents a gap analysis of some of the infrastructure challenges associated with large-scale data center deployment. Drawing from a national workshop hosted by INL in October of 2025, the report synthesizes stakeholder insights, survey data, and technical discussions to identify critical barriers and research needs. Key findings highlight the growing preference for behind-the-meter generation, the perceived inadequacy of legacy interconnection processes, and the urgent need for improved coordination between utilities, regulators, and data center developers. Environmental concerns such as water use and noise pollution, as well as economic constraints like equipment lead times and cost allocation, are also explored. The report outlines national lab capabilities in modeling, simulation, and technical assistance, and proposes targeted R&D priorities to support resilient, scalable, and efficient integration of data centers into the grid.

22 - GENERAL STUDIES OF NUCLEAR REACTORS

Examples of State and Utility Actions on Proactive Planning and Investments

As states across the U.S. confront rising electricity demand, clean energy deployment, grid modernization imperatives, and the integration of large new loads, some regulators and utilities are shifting away from reactive, “just-in-time” investment approaches toward more proactive planning and investment frameworks. This report compiles examples of jurisdictional and utility actions that reshape planning processes, cost recovery mechanisms, and performance oversight to anticipate—rather than simply respond to—future grid needs. Several themes emerge from state actions examined in this report. First, legislatures and commissions are increasingly directing utilities to proactively upgrade their distribution and transmission systems, reflecting a shift toward a forward-looking system that aligns planning with state policy goals. Second, states are establishing long-term, iterative planning frameworks that often feature multi-year horizons, biannual or annual compliance reporting, structured opportunities for stakeholder engagement, and emphasis on collaboration among utilities, regulators, and stakeholders. Third, states are actively investigating innovative cost recovery mechanisms designed to support accelerated electrification and grid modernization, while balancing consumer advocates’ concerns regarding the ratepayer financial risks of premature investments. Fourth, performance metrics and reporting requirements are being developed to ensure transparency and accountability for proactive investments. Fifth, methodological improvements in planning—such as aligning load forecasting assumptions, incorporating sensitivities, and considering load management potential across building, vehicles, storage, and demand response—are recurring areas of stakeholder focus across jurisdictions. Overall, these developments signify a growing recognition among state regulators, utilities, and stakeholders that proactive planning—supported by clear definitions, consistent and transparent methodologies, robust performance metrics, and innovative cost recovery mechanisms—is a tool that can be used to address the scale and urgency of contemporary grid needs.

electricity market

Control Room of the Future Testbed Workshop – After-Action Report

The U.S. Department of Energy’s Office of Electricity is supporting a one-year, multi-laboratory effort to define the needs and requirements for a Control Room of the Future testbed, or CROFT. The effort responds to increasing grid complexity driven by large new loads, dynamic generation resources, and the growing adoption of advanced technologies and tools, including artificial intelligence (AI) and machine learning (ML). To support safe, secure, and effective grid modernization, CROFT will focus on how emerging technologies and tools can be rigorously evaluated in realistic operational settings, with attention to human-machine interaction, cognitive load, and workforce readiness. The project team includes Argonne National Laboratory, Idaho National Laboratory, National Laboratory of the Rockies, and Pacific Northwest National Laboratory. As part of the scoping effort, the team conducted two industry-focused workshops: one at DTECH on February 5, 2026, informed by prior industry interviews, and a second on May 4, 2026, adjacent to IEEE T&D. These engagements brought together utilities, vendors, consultants, national laboratories, academia, and government stakeholders to identify and prioritize use cases, barriers, validation needs, data-sharing constraints, and near- and longer-term requirements. This feedback will directly inform CROFT’s architecture and research focus areas, ensuring the testbed is grounded in real-world operational needs and designed to evaluate emerging technologies and tools in realistic control-room environments.

artificial intelligence

Quality Investigation of Pultruded Carbon Fiber Panels Subjected to Four-Point Flexure via Fiber Optic Sensing

Pultruded carbon fiber-reinforced composites are attractive to the wind energy industry due to the rapid production of highly aligned unidirectional composites with enhanced fiber volume fractions and increased specific strength and stiffness. However, high volume carbon fiber manufacturing remains cost-prohibitive. This study investigates the feasibility of a pultruded low-cost textile carbon fiber-reinforced epoxy composite as a promising material in spar cap production was undertaken based on mechanical response to four-point flexure loading. As spar caps are primarily subjected to flexural loading, large-span four-point flexure was considered, and coupon testing was restricted to tensile modulus and compression strength assessment. High-resolution spatial fiber optic strain sensing was utilized to determine spatial strain distribution during four-point flexure, revealing consistent strain along the length of the part and proved to be an excellent option for process manufacturing quality examination. Additionally, holes with diameters of 2.49 mm, 5.08 mm, and 1.93 mm were drilled through the thickness of full-width parts to determine the feasibility of structural health monitoring of pultruding parts internal to wind blades via fiber optic strain sensing.

Chemistry

Job Scheduler-Driven Power Gateway for High Performance Computing

Power gateways in the form of a microgrid can incorporate multiple distributed energy resources (DER) in either grid forming or grid following mode and support high performance computing (HPC) power profiles including the large load-follow requirements observed in multi-user HPC systems. The microgrid’s flexibility to operate in either grid forming or grid following mode and to actively switch between these modes enables baseline power from multiple non-baseline DER while maintaining high power quality metrics for the HPC system. But this enormous flexibility in demand response and time of use shifting is generally programmed independently of any integration with an HPC job scheduler which can better inform the load shaping by the microgrid. While there are many existing approaches where the HPC job scheduler takes in information from the grid to make queue scheduling decisions, this work takes the opposite view and explores a scheduler where the jobs in the queue can directly impact the settings of the grid. Several HPC scheduler strategies are tested where the jobs in the queue directly impact the settings of a microgrid designed for HPC operation which is driving a datacenter with three classes of HPC architectures. The scheduler operation is shown using a microgrid with 64 kW of solar capacity and 320 kWh of battery over a period of 21 days operating with significant low-follow swings, a throttled grid, cloudy conditions, switching between grid following and grid forming modes, and a wide range of battery states-of-charge all while maintaining high quality power metrics. The scheduler provides a mechanism for the job queue to directly impact a power gateway like a microgrid and to improve HPC power outcomes such as maximizing renewable energy usage

microgrid

Navigating Integration: Key Challenges for Data Centers, Nuclear Stakeholders, and Utility Operators

he exponential growth of data centers—driven by artificial intelligence and cloud computing—is reshaping the U.S. energy landscape, presenting urgent challenges and transformative opportunities for data center developers, nuclear energy providers, and utility operators. As data centers are projected to consume up to 12% of U.S. electricity by 2028, stakeholders must address rapid deployment needs, grid congestion, and the demand for reliable, high-quality power. This presentation explores the multifaceted barriers to integrating data centers with nuclear and utility infrastructure, including land use constraints, public perception, regulatory complexity, and workforce alignment. It highlights the distinct priorities and operational cultures of each sector, and the friction that arises from misaligned planning horizons and risk tolerances. We examine collaborative strategies such as co-siting, hybrid power-purchase agreements, unified community engagement, and innovative financing models.

22 - GENERAL STUDIES OF NUCLEAR REACTORS

Data Centers and Digital Assurance Introduction to Supply Chain and Cybersecurity for Data Centers, Session 1

The first session of the TADA (Technical Assistance for Digital Assurance) Data Centers Cohort Workshop, held on October 30, 2025, introduced foundational concepts of Digital Assurance in the context of data center and grid integration. Sponsored by the U.S. Department of Energy, the workshop brought together utilities, data center operators, developers, and vendors to address cybersecurity and supply chain vulnerabilities. The session emphasized the growing criticality of data centers within the electric grid and the need for secure, real-time, bidirectional communication. Participants explored the principles of Digital Assurance, including cybersecurity, cyber-informed engineering (CIE), and lifecycle security, and applied a threat-vulnerability-consequence framework to identify and mitigate risks at the data center–grid interface. Discussions covered a range of threats such as spoofed dispatch signals and insider threats, architectural vulnerabilities like SCADA interfaces and insecure protocols, and potential consequences including cascading grid failures. The session also raised strategic questions about business value, vendor assurance, and defining cyber boundaries and responsibilities. This foundational workshop set the stage for deeper technical analysis and the development of actionable frameworks in subsequent sessions. Session 1 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION