A summary of the high temperature alkali metal corrosion program at Brookhaven National Laboratory
Evaluation of refractory alloys for containing liquid and boiling sodium
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Evaluation of refractory alloys for containing liquid and boiling sodium
This viewgraph document reviews test results from tests of different material used for wire insulation for flame propagation and flammability. The presentation focused on investigating data variability both within and between laboratories; evaluated the between-laboratory consistency through consistency statistic h, which indicates how one laboratory s cell average compares with averages from other labs; evaluated the within-laboratory consistency through the consistency statistic k, which is an indicator of how one laboratory s within-laboratory variability compares with the variability of other labs combined; and extreme results were tested to determine whether they resulted by chance or from nonrandom causes (human error, instrument calibration shift, non-adherence to procedures, etc.)
A prototype dual-axis electrolytic tilt sensor package for angular position measurements was built and evaluated in a laboratory environment. The objective was to investigate the use of this package for making wind tunnel wall attitude measurements for the National Transonic Facility (NTF) at NASA Langley Research Center (LaRC). The instrumentation may replace an existing, more costly, and less rugged servo accelerometer package (angle-of-attack package) currently in use. The dual-axis electrolytic tilt sensor package contains two commercial electrolytic tilt sensors thermally insulated with NTF foam, all housed within a stainless steel package. The package is actively heated and maintained at 160 F using foil heating elements. The laboratory evaluation consisted of a series of tests to characterize the linearity, repeatability, cross-axis interaction, lead wire effect, step response, thermal time constant, and rectification errors. Tests revealed that the total RMS errors for the x-axis sensor is 0.084 degree, and 0.182 degree for the y-axis sensor. The RMS errors are greater than the 0.01 degree specification required for NTF wall attitude measurements. It is therefore not a viable replacement for the angle-of-attack package in the NTF application. However, with some physical modifications, it can be used as an inexpensive 5-degree range dual-axis inclinometer with overall accuracy approaching 0.01 degree under less harsh environments. Also, the data obtained from the tests can be valuable for wind tunnel applications of most types of electrolytic tilt sensors.
The practical use of small-gage round wire for electrical wiring in manned air and space vehicle environments is discussed. The investigation consisted on a study of wire construction and candidate wire harness concepts, fabrication of small-gage wire harnesses, and verification of promising configurations by laboratory evaluation. The wire constructions selected for harness fabrication are described. Results of the laboratory evaluation are included.
A single axis rotation sensor, utilizing a 200 m single mode optical fiber in a 30 cm diameter coil has been constructed and tested in the laboratory. A He-Ne laser is the light source for the Sagnac interferometer-mode sensor. The outputs of Si detectors viewing two complementary interference patterns are electronically differenced to obtain a rotation-dependent signal. Linear response over a rotation rate range of about 0.0001 to 0.1 rad/sec was obtained.
The technology and applications evaluation task focuses on defining performance and cost requirements for flywheels in the various areas of application. To date the DOE program has focused on automotive applications. The composite materials effort entails the testing of new commercial composites to determine their engineering properties. The rotor and containment development work uses data from these program elements to design and fabricate flywheels. The flywheels are then tested at the Oak Ridge Flywheel Evaluation Laboratory and their performance is evaluated to indicate possible areas for improvement. Once a rotor has been fully developed it is transferred to the private sector.
At the NASA Glenn Research Center, a fully operational fuel cell test and evaluation laboratory is available which is capable of evaluating fuel cell components and systems for future NASA missions. Components and subsystems of various types can be operated and monitored under a variety of conditions utilizing different reactants. This fuel cell facility can test the effectiveness of various component and system designs to meet NASA's needs.
The investigations of the software evaluation laboratory into the software development process at NASA/Goddard are described. A data collection process for acquiring detailed histories of software development projects is outlined. The application of different sets of software methodologies to specific applications projects is summarized. The effect of the development methodology on productivity is discussed.
Many aging composite overwrapped pressure vessels (COPVs), being used by the National Aeronautics and Space Administration (NASA) are currently under evaluation to better quantify their reliability and clarify their likelihood of failure due to stress rupture and age-dependent issues. As a result, some test and analysis programs have been successfully accomplished and other related programs are still in progress at the NASA Johnson Space Center (JSC) White Sands Test Facility (WSTF) and other NASA centers, with assistance from the commercial sector. To support this effort, a group of Nondestructive Evaluation (NDE) experts was assembled to provide NDE competence for pretest evaluation of test articles and for application of NDE technology to real-time testing. Techniques were required to provide assurance that the test article had adequate structural integrity and manufacturing consistency to be considered acceptable for testing and these techniques were successfully applied. Destructive testing is also being accomplished to better understand the physical and chemical property changes associated with progression toward "stress rupture" (SR) failure, and it is being associated with NDE response, so it can potentially be used to help with life prediction. Destructive work also includes the evaluation of residual stresses during dissection of the overwrap, laboratory evaluation of specimens extracted from the overwrap to evaluate physical property changes, and quantitative microscopy to inform the theoretical micromechanics.
An acoustic analysis was performed to establish window designs for advanced turboprop powered aircraft. The window transmission loss requirements were based on A-weighted interior noise goals of 80 and 75 dBA. The analytical results showed that a triple pane window consisting of two glass outer panes and an inner pane of acrylic would provide the required transmission loss and meet the sidewall space limits. Two window test articles were fabricated for laboratory evaluation and verification of the predicted transmission loss. Procedures for performing laboratory tests are presented.
World class facilities are: 1. National center for advanced manufacturing (NCAM). Composite development facility. Weld development laboratories. Rapid prototyping laboratory. Thermal spray facility. Thermal protection system development facility. Non-destructive evaluation laboratories. 2. SEM and failure analysis. 3. Hydrogen test facility. 4. Surface science diagnostic laboratory. 5. Space environmental effect facility. 6. Material combustion research facility.
The results of a laboratory evaluation of electrolytic tilt sensors as potential candidates for measuring model attitude or angle of attack in wind tunnel tests are presented. The performance of eight electrolytic tilt sensors was compared with that of typical servo accelerometers used for angle-of-attack measurements. The areas evaluated included linearity, hysteresis, repeatability, temperature characteristics, roll-on-pitch interaction, sensitivity to lead-wire resistance, step response time, and rectification. Among the sensors being evaluated, the Spectron model RG-37 electrolytic tilt sensors have the highest overall accuracy in terms of linearity, hysteresis, repeatability, temperature sensitivity, and roll sensitivity. A comparison of the sensors with the servo accelerometers revealed that the accuracy of the RG-37 sensors was on the average about one order of magnitude worse. Even though a comparison indicates that the cost of each tilt sensor is about one-third the cost of each servo accelerometer, the sensors are considered unsuitable for angle-of-attack measurements. However, the potential exists for other applications such as wind tunnel wall-attitude measurements where the errors resulting from roll interaction, vibration, and response time are less and sensor temperature can be controlled.
The results of a laboratory evaluation of three types of electrolytic tilt sensors as potential candidates for model attitude or angle of attack (AOA) measurements in wind tunnel tests are presented. Their performance was also compared with that from typical servo accelerometers used for AOA measurements. Model RG-37 electrolytic tilt sensors were found to have the highest overall accuracy among the three types. Compared with the servo accelerometer, their accuracies are about one order of magnitude worse and each of them cost about two-thirds less. Therefore, the sensors are unsuitable for AOA measurements although they are less expensive. However, the potential for other applications exists where the errors resulting from roll interaction, vibration, and response time are less, and sensor temperature can be controlled.
Digital fiber-optic data-link terminal modules are being developed in a number of laboratories, and often the modules take the form of black boxes without convenient access to internal signals. This paper discusses types of measurements which can be made using only the digital terminals of the link. Bit-error-rate (BER) vs signal-power data can, of course, provide a means for proving overall link performance, but it can also be used to determine certain internal parameters of the receiver. The theoretical dependence of the BER-vs-light-signal-power curve shape on receiver input-noise equivalent power and comparator slicing level is discussed. BER-vs-light-signal-power measurements obtained with an experimental link are presented and interpreted with the aid of the theoretical curves. The effects of other problems, such as hum or oscillation, on the BER data are mentioned. Sensitivity of the system BER to bit rate is also discussed, with application to determining system operating limits. Since BER measurements are simple to make and can easily be automated, they may prove to be a useful means for either laboratory evaluation or production-line acceptance testing of sealed terminal modules.
Evaluation of antimotion sickness drugs under controlled laboratory conditions
We present results of laboratory evaluations of several microlens types that have been designed and fabricated at the Lockheed Research and Development Division. The microlenses include wideband and dispersive types, in isolation and in arrays, and fabricated with binary or grayscale methods. Different lens pixel geometries are considered, including square, hexagonal, and skewed microlenses. We describe our micro-optics laboratory testbed which has been designed for the evaluation of individual lenslets or 2D arrays at selected spectral wavelengths. Measurement capabilities include focal length, point-spread functions, wavefront quality, and modulation transfer functions. Our present effort focuses on the results of point spread function measurements and their comparison with design predictions.
An unusual application of the method proposed by Asher (1958) for structural dynamic and modal testing is discussed. Asher's method has the capability, using the admittance matrix and multiple-shaker sinusoidal excitation, of separating structural modes having indefinitely close natural frequencies. The present application uses Asher's method in conjunction with a modern Fourier analyzer system but eliminates the necessity of exciting the test structure simultaneously with several shakers. Evaluation of this approach with numerically simulated data demonstrated its effectiveness; the parameters of two modes having almost identical natural frequencies were accurately identified. Laboratory evaluation of this approach was inconclusive because of poor experimental input data.
Laboratory evaluates artificially intelligent engine-system monitors without potentially hazardous measurements on actual engines. Monitor enhances engine controller by detecting undesirable trends and counteracting them. Once proved in laboratory, monitor will then be tried on real engine.