High resolution microstructural, chemical studies and localized burnup analysis in an irradiated U–10Zr metallic fuel

This study involves high resolution characterization of a sodium bonded solid uranium (U)-10 wt% zirconium (Zr) metallic fuel irradiated in Fast Flux Test Facility (FFTF). The fuel centerline temperature during irradiation was estimated to be around 675 °C with the peak burnup 13.1 atomic percent. Samples for transmission electron microscopy (TEM) and atom probe tomography (APT) were prepared from different regions/zones in the fuel cross section radially to elucidate the microstructural changes and chemical redistribution of solute elements as well as fission products during irradiation experiment. TEM results indicate the irradiation in fast flux testing leads to the formation of extensive Zr-rich precipitates with varying sizes in the U–Zr fuel matrix. APT analysis performed to investigate redistribution of Zr, U and fission products along the radial direction of fuel pin showed Zr-rich precipitates entrapping the fission products in higher concentration as compared to the α-U phases. Here, the local burnup ( 235 U depletion) is found to be consistent, calculated by quantification of 235 U, 236 U and 238 U isotopes from mass spectrum obtained from APT along the radial direction. Zr-rich precipitation and its implication on fuel constitutional redistribution are discussed based on SEM, TEM and APT results.

APT↗

Deuterated water as a substrate-agnostic isotope tracer for investigating reversibility and thermodynamics of reactions in central carbon metabolism

Stable isotope tracers are a powerful tool for the quantitative analysis of microbial metabolism, enabling pathway elucidation, metabolic flux quantification, and assessment of reaction and pathway thermodynamics. 13 C and 2 H metabolic flux analysis commonly relies on isotopically labeled carbon substrates, such as glucose. However, the use of 2 H-labeled nutrient substrates faces limitations due to their high cost and limited availability in comparison to 13 C-tracers. Furthermore, isotope tracer studies in industrially relevant bacteria that metabolize complex substrates such as cellulose, hemicellulose, or lignocellulosic biomass, are challenging given the difficulty in obtaining these as isotopically labeled substrates. In this study, we examine the potential of deuterated water ( 2 H 2 O) as an affordable, substrate-neutral isotope tracer for studying central carbon metabolism. We apply 2 H 2 O labeling to investigate the reversibility of glycolytic reactions across three industrially relevant bacterial species -C. thermocellum, Z. mobilis, and E. coli-harboring distinct glycolytic pathways with unique thermodynamics. We demonstrate that 2 H 2 O labeling recapitulates previous reversibility and thermodynamic findings obtained with established 13 C and 2 H labeled nutrient substrates. Furthermore, we exemplify the utility of this 2 H 2 O labeling approach by applying it to high-substrate C. thermocellum fermentations -a setting in which the use of conventional tracers is impractical-thereby identifying the glycolytic enzyme phosphofructokinase as a major bottleneck during high-substrate fermentations and unveiling critical insights that will steer future engineering efforts to enhance ethanol production in this cellulolytic organism. This study demonstrates the utility of deuterated water as a substrate-agnostic isotope tracer for examining flux and reversibility of central carbon metabolic reactions, which yields biological insights comparable to those obtained using costly 2 H-labeled nutrient substrates.

09 BIOMASS FUELS↗

Distinguishing fissile uranium isotopes using an active well neutron coincidence counter

Proposed thorium-based nuclear fuel cycles are likely to require quantification and verification of 233 U within nuclear material. Because of their similar fission cross sections, active neutron nondestructive assay (NDA) systems may respond similarly to 233 U and 235 U. Traditional safeguards equipment has been optimized for 235 U and 238 U quantification associated with conventional uranium/plutonium fuel cycles and may not be directly applicable to 233 U quantification when mixed with other actinides. This work used models of the large volume active well coincidence counter (LV-AWCC) at Oak Ridge National Laboratory to evaluate the performance of this neutron NDA system to differentiate fissile uranium isotopes. The models were developed to simulate NDA system performance in response to a number of triangular radiation signature training device sources within the central cavity or well. This work predicted that the LV-AWCC can effectively differentiate 233 U from 235 U in certain modes of operation. In active mode, the LV-AWCC with the cadmium liner results in different doubles count rates between the fissile isotopes for a given fissile uranium mass. Without the cadmium liner, the uranium isotopes provide a statistically indistinguishable doubles count rate response for the fissile masses considered in this work (up to approximately 150 g). The cadmium liner serves to harden the neutron interrogation spectrum, which better exploits the notable difference in the 233 U and 235 U fission cross sections at approximately 1 eV. In passive mode, the two fissile isotopes exhibit different doubles and singles count rates regardless of liner presence because the passive source strength of 233 U is approximately 2 orders of magnitude stronger than that of 235 U due to the shorter half-life and correspondingly higher (α, n) yield. We conclude that using neutron interrogation in the LV-AWCC, two measurements are needed to quantify 233 U content in mixed uranium items. The first measurement is used to determine the total fissile uranium mass using a mode that cannot distinguish fissile isotopes (i.e., where a similar response is observed for both fissile uranium isotopes such as active doubles without cadmium or using a thermal neutron interrogation source). In conclusion, the second measurement is used to determine the 233 U content by using a differentiating technique (e.g., passive doubles, passive doubles to singles ratio, active doubles with cadmium).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of PBR Spent Fuel Criticality and Dose Rate Compliance for Storage and Transportation

Spent tri-structural isotropic (TRISO)–based fuels have a strong track record in storage and transportation without documented incidents. This work seeks to reduce uncertainty to aid in more informed spent fuel management of TRISO-based fuels by modeling both fresh and spent pebble bed reactor (PBR) fuel and comparing the results to the regulatory standards from 10 CFR 71. SCALE was used for all modeling due to it having fast and accurate methods for handling PBR fuel modeling, as well as having an efficient method for shielding calculations in monaco with automated variance reduction using importance calculations (MAVRIC), which utilizes the consistent adjoint-driven importance sampling (CADIS) and the forward-weighted consistent adjoint-driven importance sampling (FW-CADIS) methods. KENO-VI was used for all criticality calculations, TSUNAMI was used for uncertainty quantification on k-effective, TRITON and the Oak Ridge isotope generation code (ORIGEN) were both used for depletion of the fuel, and MAVRIC was used for shielding calculations. For criticality assessments, this study focused on the requirement that the value of the neutron multiplication factor, k-effective (k-eff), would not exceed a peak value of 0.95, including uncertainty, with 95% confidence. Criticality was initially examined by modeling fresh fuel from three different designs—HTR-10 fuel, PBMR-400 fuel, and demonstration fuel representative of a TRISO-fueled modern high-temperature gas reactor (HTGR) design, henceforth referred to as Demo HTGR—and placing them into various sized containers with conditions described in 10 CFR 71 to quantify the peak k-eff state. When the peak value of 0.95 k-eff was exceeded, mitigation methods were examined in those scenarios. Burnup credit, pebble displacement in areas of strong neutron multiplication, and random pebble replacement using pebbles of various compositions and replacement fractions were examined. In summary, the criticality of PBR fuels can be well accounted for by restricting container size, taking credit for burnup, or by displacing/replacing pebbles. Uncertainty of the k-eff due to nuclear data uncertainties was recorded at ~0.6644%Δk/k, or roughly 664% mil (pcm). The nuclear data–induced uncertainty was relatively small and should not require significant modification in the design to be accounted for. Revisions to the evaluated nuclear data file values have been shown to have a larger impact than nuclear data–induced uncertainty. For dose rate aspects, U.S. Nuclear Regulatory Commission regulations require a maximum dose rate of 10 millirem per hour (mrem/h) at 2 meters. In examining the dose rate behavior of spent PBR fuel, the representative Demo HTGR fuel was modeled exclusively due to it possessing the highest target burnup of the examined fuels. Equilibrium cycle modeling methods were used to produce a higher-fidelity discharge isotopic composition than simple assumptions, such as reflected pebbles. The discharge composition was used as a source term in the fixed-source transport shielding calculations, and dose rates were calculated at 2 m for the shortest possible cooling time. The low concentration of fuel material led to dose rates that were in line with regulatory limits, despite the high burnup when compared to traditional light water reactor fuels. In conclusion, the methods employed in this study would require more work to further verify and validate and are limited to the criticality and dose rate analyses performed.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Applications of Hyporheic Zone Sampling for Assessing VOC Plume Engineered Remediation and Natural Attenuation Effectiveness - 20414

Determining the efficacy of engineered remedial actions and/or natural attenuation as an acceptable EPA Record of Decision (ROD) must address long-term temporal and spatial variability. Since final plume downslope destinations are aquifers and related surface streams and rivers, hyporheic zone sampling is essential. Comprehensive hyporheic sampling documents plume groundwater remediation prior to upwelling into stream benthic strata and natural attenuation within this dynamic zone itself. Our intensive sampling of the Savannah River Site (SRS) Chemical, Metals, and Pesticides (CMP) Pits VOC plume-fringe from 2005 to 2018 documented PCE natural attenuation and effectiveness of In Situ Thermal Treatment (ISTT). Most plume hyporheic upwelling was delimited to a 20 m inflow reach along Pen Branch. Our study utilized corroborative sampling methodologies: ambient hole-water grab samples: passive diffusion bags (PDB); and hole-core sediment samples to confirm station to station spatial and temporal trends. VOC hot spot detections were confirmed from both groundwater and soil core samples. VOC pathways through the Pen Branch hyporheic zone were assessed at hole-installation using sequential soil samples from augered cores and grab-samples of hole-bottom water. Longer term, composite water samples were collected from PDBs deployed for a minimum two-week equilibration period. Soil samples were collected from the 15 and 65 cm core levels in December 2017 and June 2018 at six stations. Additional core depths of 40 and 85 cm were sampled in June 2018 at the highest VOC station (5DB80). All samples were analyzed in an EPA certified lab by purge and trap GC-MS. Effectiveness of previous ISTT and soil vapor extraction (SVE) for this CMP Pits PCE plume, was clearly documented by significant downward trends in VOC at hyporheic zone stations prior to December 2015. Achieving final stage conversions of PCE daughter products to ethene and CO{sub 2} may be limited depending upon suitable interactions between hyporheic zone sediment morphology, hydrology, and redox conditions. Because declines in VOC daughter products at our hyporheic stations may also be caused by physical actions of dilution and dispersion rather than true biochemical dechlorination, full quantification of natural attenuation requires the use of compound-specific isotope ratio analysis (CSIA) and microbial 16S rRNA with qPCR. To assist these next-phase efforts, a natural attenuation index (NAI) was used to help produce quicker, more cost-effective decision making for locating CSIA and microbial sampling efforts. The NAI used natural logarithm transformed GC-MS results for station VOC degradation compounds versus VOC parent compounds. Wide differences were observed between stations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The development and evolution of biological AMS at Livermore: a perspective

Biological accelerator mass spectrometry (AMS) provides ultrasensitive carbon-14 isotopic analysis enabling a deeper understanding of human health concerns by enabling quantification of pharmacokinetics and other molecular endpoints directly in humans. It enables environmentally and human relevant studies of metabolic pathways through the use of very low concentrations of labeled metabolic substrates in cells and organisms. Here, we discuss why AMS is an important tool for the biosciences, the development and evolution of biological AMS at Livermore and discuss technical refinements that will improve the efficiency of operation for the measurement of ultra-trace levels of 14 C, which, long term, will enable greater ease of use and sample throughput.

47 OTHER INSTRUMENTATION↗

Realistic application of short-lived fission product delayed neutron, gamma-ray analysis for simultaneous nondestructive trace quantification of U, Pu mixtures on cellulose swipes

Detection and characterization of fissile traces are of interest to the international nuclear nonproliferation community, including the International Atomic Energy Agency. Pre-inspection check samples are analyzed by neutron activation analysis at the High Flux Isotope Reactor operated by the Oak Ridge National Laboratory under the umbrella of the IAEA Network of Analytical Laboratories. The simultaneous quantification of U and Pu mixtures was accomplished using the combined delayed neutron (DN) delayed gamma-ray (DG) method to analyze cellulose swipes with actinide loading <1ng in a blind field trial. The total fissile quantity was measured by the DN counts and the relative proportions of U, Pu were determined by calibration of the 104 Tc / 141 Ba fission product count ratio using known mixtures. The DNDG method demonstrated high accuracy in flagging the presence of 239 Pu in uranium down to <100 pg mass loading. In conclusion, peak significance tests helped to control false positive Pu flagging and simultaneous quantification of U and Pu loading was accomplished on samples that passed the significance tests.

36 MATERIALS SCIENCE↗

Simulation of a TRISO MiniFuel irradiation experiment with data-informed uncertainty quantification

An irradiation experiment using tristructural isotropic (TRISO) fuel particles and the miniature fuel (MiniFuel) irradiation vehicle was performed in Oak Ridge National Laboratory’s High Flux Isotope Reactor (HFIR) to support development of the Kairos Power fluoride salt–cooled, high-temperature reactor (KP-FHR). Here, this paper describes modeling predictions of temperatures and fuel burnup for the as-built experiment. An uncertainty quantification (UQ) analysis was performed to determine the effect of TRISO particle volume and position on the temperature predictions at various fuel heat generation rates (HGRs). This UQ study utilized fuel kernel position and volume measurements previously collected using X-ray computed tomography (XCT) techniques and Monte Carlo sampling methods to generate fuel compact cases that were then analyzed using a finite element thermal model. The UQ analysis indicated that uncertainty in calculated temperatures caused by varying TRISO particle arrangement is relatively small, even at high fuel HGR. Final predictions of particle temperatures throughout the irradiation are shown to be relevant to KP-FHR normal and off-normal operating conditions and to previous TRISO irradiation experiments. The combination of XCT with UQ analyses will inform post-irradiation examination (PIE) of the irradiated fuel compacts, and these analyses can be used to develop fuel performance models for coated particle fuel forms. Both PIE of separate-effects irradiation data and enhanced fuel performance modeling support accelerated qualification of TRISO fuels for a broad range of advanced reactor applications. The novel approach demonstrated here of measuring TRISO particle configurations with XCT methods and generating representative fuel compacts for finite element modeling and UQ analysis could be leveraged by the broader particle fuel community in the development of other TRISO fuel experiments in which these variables may have a significant impact on key outcomes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Initial development of a generic fluoride salt-cooled reactor model

Fluoride high-temperature reactors (FHRs) are high-temperature, low-pressure reactor concepts that use tri-structural isotropic (TRISO) fuel and molten fluoride salt coolant. These reactors have the potential to provide both electrical power and high-temperature process heat. We used generic FHR parameters for a pebble-bed FHR to develop an initial model with fresh fuel for a generic FHR (gFHR) in MELCOR and SCALE (NEWT and KENO). In this paper, we present the development of our gFHR models, which will serve as the baseline for a sensitivity and uncertainty analysis to quantify the range of possible source terms for FHRs in severe accidents. We present MELCOR results for fuel and coolant temperatures through the core, a nodalization study for the steady-state thermal hydraulic model, and development of reactor physics models in SCALE. As this work progresses, these models will be used to calculate source terms for a loss-of-forced-flow accident and to conduct a sensitivity study on this accident to establish a range of possible source terms. SCALE will provide reactor physics parameters like isotopic inventory, decay heat generation, and temperature coefficients of reactivity. Using the uncertainty quantification tools within SCALE, we will generate distributions for those parameters and will use the uncertainty quantification code RAVEN or DAKOTA to sample those distributions in MELCOR to quantify the impact of reactor physics and thermal hydraulic uncertainties on FHR source terms. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Micro-Quantification of Helium-3 and Helium-4 in TPBAR Components

This report documents the method development for measuring helium isotopes in micrometer-sized samples of tritium producing burnable absorption rod (TPBAR) components. Helium isotopes were measured as a tracer for tritium, which decays to 3 He with a half-life of 12.33 years. Getter and cladding materials from the TPBARs were analyzed, as they are designed to trap tritium. Therefore, constraining the diffusivity of tritium through these materials is of key importance. To first establish the reliability of the noble gas mass spectrometer, a reference gas with a relative 4 He/ 3 He ratio of 1000 was pre-mixed. This standard was measured several times to ensure measurements were reproducible. Unirradiated and irradiated getter and cladding samples of TPBARs were cut into 1-100 µm 3 cubes and analyzed for 3 He and 4 He content. The unirradiated materials had helium content equal to or less than that of the measured instrument background. Irradiated cladding also had instrument background levels of helium while irradiated getters had elevated levels of 3 He, interpreted to be the decay product of tritium. No diffusion of 4 He was observed in any of these materials, however, indicating that the 3 He detected in the irradiated getter was produced in situ after tritium diffusion and decay. These findings validate this method as a way to trace tritium diffusion in reactor materials.

07 ISOTOPE AND RADIATION SOURCES↗

Coupling of nitric acid digestion and anion-exchange resin separation for the determination of methylmercury isotopic composition within organisms

Isotope ratios of methylmercury (MeHg) within organisms can be used to identify sources of MeHg that have accumulated in food webs, but these isotopic compositions are masked in organisms at lower trophic levels by the presence of inorganic mercury (iHg). To facilitate measurement of MeHg isotope ratios in organisms, we developed a method of extracting and isolating MeHg from fsh and aquatic invertebrates for compound-specifc isotopic analysis involving nitric acid digestion, batch anion-exchange resin separation, and pre-concentration by purge and trap. Recovery of MeHg was quantifed after each step in the procedure, and the average cumulative recovery of MeHg was 93.4±2.9% (1 SD, n=28) for biological reference materials and natural biota samples and 96.9±1.8% (1 SD, n=5) for aqueous MeHgCl standards. The amount of iHg impurities was also quantifed after each step, and the average MeHg purity was 97.8±4.3% (1 SD, n=28) across all reference materials and natural biota samples after the fnal separation step. Measured MeHg isotopic compositions of reference materials agreed with literature values obtained using other MeHg separation techniques, and MeHg isotope ratios of aqueous standards, reference materials, and natural biota samples were reproducible. On average, the reproducibility associated with reference material process replicates (2 SD) was 0.10‰ for δ 202 MeHg and 0.04‰ for Δ 199 MeHg. This new method provides a streamlined, reliable technique that utilizes a single sample aliquot for MeHg concentration and isotopic analysis. Furthermore, this promotes a tight coupling between MeHg concentration, %MeHg, and Hg isotopic composition, which may be especially benefcial for studying complex food webs with multiple isotopically distinct sources of iHg and/or MeHg.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Cost of (In-) Accurate Waste Characterization in the U.S. Nuclear Power Industry - 20066

Proper disposal of waste has never been a human priority. Our history is full of examples of throwing away things with minimal effort or thought to consequence. That is until disease or toxicity become apparent and we realize we need to change. Unfortunately, we almost never have all the information we need at the time we make decisions. In addition to the technical and scientific issues, profits and politics are also factors. Newton's third law also applies to politics and so for every policy (action) put in place, there will be (opposite reaction) forces in play to push back against it. These forces are seldom balanced and so the reaction to the discovery of harm is to over-correct and destroy the benefit to be had. This of course causes those who want the benefit, or profit from it, to work to undermine or repeal those measures put in place to eliminate the harm. The issue is exacerbated when the problem to be solved is highly technical and at the edge of our science so that the harm and benefit cannot be easily or accurately quantified. At these times, reason often goes out the window and our decision makers are influenced by either greed or fear as these emotions are much easier to stoke. Those of us in the middle, with the charge to 'do the right thing for the least cost', are therefore frequently constrained and forced into actions that are neither technically the right thing to do and not cost effective. The cost of radioactive waste disposal is based on the concentrations of various radioisotopes in the waste. Some of these isotopes are relatively easy to quantify and some are not. Most laboratory methods for quantification are limited in the amount of activity that can be present during the measurement process. Current nuclear plants were not designed with the idea that taking truly representative waste samples would be important. The limits used to define waste class and therefore cost are precisely defined but the methods for determining those concentrations are far less precise. Improving the accuracy of radioactivity concentrations in waste and having consistent and reasonable oversight can reduce waste costs through active management of the process. So what can we do about it? Science may provide an answer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantitative chemical assay of nanogram-level particulate matter using aerosol mass spectrometry: characterization of particles collected from uncrewed atmospheric measurement platforms

Abstract. Aerosol generation techniques have expanded the utility of aerosol mass spectrometry (AMS) for offline chemical analysis of airborne particles and droplets. However, standard aerosolization techniques require relatively large liquid volumes (e.g., several milliliters) and high sample masses that limit their utility. Here we report the development and characterization of a micronebulization AMS (MN-AMS) technique that requires as low as 10 µL of sample and can provide the quantification of the nanogram level of organic and inorganic substances via the usage of an isotopically labeled internal standard (34SO42-). Using standard solutions, the detection limits for this technique were determined at 0.19, 0.75, and 2.2 ng for sulfate, nitrate, and organics, respectively. The analytical recoveries for these species are 104 %, 87 %, and 94 %, respectively. This MN-AMS technique was applied successfully to analyze filter and impactor samples collected using miniature particulate matter (PM) samplers deployable on uncrewed atmospheric measurement platforms, such as uncrewed aerial systems (UASs) and tethered balloon systems (TBSs). Chemical composition of PM samples collected from a UAS field campaign conducted at the Department of Energy's (DOE) Southern Great Plains (SGP) observatory was characterized. The offline MN-AMS data compared well with the in situ PM composition measured by a co-located aerosol chemical speciation monitor (ACSM). In addition, the MN-AMS and ion chromatography (IC) agreed well for measurements of sulfate and nitrate concentrations in the PM extracts. This study demonstrates the utility of combining MN-AMS with uncrewed measurement platforms to provide quantitative measurements of ambient PM composition.

54 ENVIRONMENTAL SCIENCES↗

Fission Product Gas Monitoring During Fuel Drying Operations - 20094

The goal of the project was to devise and implement a method of accurately qualifying any noble gas emitted during fuel drying operations (part of the dry fuel storage process) in order to provide the data needed to validate the off-site dose calculations. The imputes of the project was the NRC publishing Information Notice 18-01, 'Noble Fission Gas Releases During Spent Fuel Cask Loading Operations' in February 2018. The information notice describes some industry events that occurred during vacuum drying operations as part of a dry fuel campaign. The solution was devised by Fort Calhoun Station staff in partnership with Mirion Technologies technical staff. The monitoring was accomplished by directing all the effluent from the fuel storage cask vacuum drying machine through a sample chamber containing a compact ISOCS characterized CZT based gamma spectrometer connected to a Mirion Data Analyst. This resulted near real-time quantification of the radionuclides of concern. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Resolving atomic transport through iron oxide under irradiation using isotopic tracers

Structural materials in nuclear environments are exposed to complex and harsh conditions, including high temperatures, corrosive solutions, and irradiation. Material stability and likewise degradation are fundamentally controlled by atomic transport mechanisms. Here, we investigate the influence of radiation-induced, non-equilibrium point defect populations on mass transport within model oxide systems using isotopic tracers and atom probe tomography. An isotopically labelled hematite (a-Fe2O3) film was synthesized with 16O- and 18O-rich layers (>30nm and 10 nm, respectively) sequentially deposited via molecular beam epitaxy. One region of the film was proton irradiated to ~0.1 dpa at 450°C, and regions outside the beam spot provided a non-irradiated control of thermal annealing only. 3D APT was used to directly visualize the elemental and O-isotopic redistribution following both thermal and combined thermal and irradiation conditions. Complementary scanning transmission electron microscopy (STEM) was also employed to study the microstructural evolution. Error function fits of the 18O-concentration profiles enabled quantification of diffusion coefficients.

isotopic tracers, diffusion, proton irradiation, h↗

VERA neutronics high-fidelity benchmark for a modern PWR core design

Nearly 20 years since the origin of the infamous 'Kord Smith Challenge', and after 10 years and hundreds of millions of dollars invested by the US Department of Energy into the development of the Virtual Environment for Reactor Applications (VERA), the capability to accurately simulate a modern pressurized water reactor (PWR) fuel cycle at the fuel rod level with high-fidelity Monte Carlo (MC) stochastic transport methods still evades us. The deterministic methods in VERA make approximations that allow it to be successfully benchmarked against measured data from hundreds of PWR fuel cycles, but none of these benchmarks provided information at the local fuel rod level or allowed quantification of these approximations' impact for modern PWR reload designs. Using MPACT to establish the estimated isotopic distributions and thermal hydraulic conditions in a recent and challenging reactor design, a 2D quarter-core benchmark problem was established and solved consistently with both MPACT, the 51-energy group deterministic transport solver in VERA, and Shift, the continuous-energy MC transport solver in VERA. Impacts of energy groups, ray spacing, and scattering treatment were evaluated. Though MPACT has been previously shown to perform well compared to MC methods for initial Cycle 1 cores with only fresh fuel, this is the first benchmark of MPACT for a challenging modern reload core with depleted fuel and burnable absorbers. This work establishes additional credibility for the methods in MPACT and highlights the efficiency of these methods relative to those in use by MC-based tools. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Field deployable trace radioisotope analysis through combined electrochemical and alpha spectroscopy methods

A method for depositing actinides directly onto a 4H-SiC Schottky barrier diode (SBD) detector as a field deployable actinides sensor was developed to enable off-site analysis, shortening the time to obtain critical information such as elements, concentration, and/or isotopic ratio related to the radiological situation. A thin film of Hg was first electrodeposited onto the Pt contact of the SiC diode, followed by chronoamperometric deposition of microgram levels of actinides under conventional control conditions. The 4H-SiC diode maintained consistent functionality through the electrodeposition process and showed resolved alpha-energy spectra that contained accurate isotopic information demonstrating the feasibility of a combined chemical and radiological sensor for field actinide detection and quantification.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗