Assessment of Core Status of Fukushima Daiichi Nuclear Power Plant

There were some events and phenomena that occurred which have been deemed specific to the Fukushima Daiichi NPP. The primary issues were as follows: - Direct steam leakage from the reactor pressure vessels (RPVs) to the dry-wells through the gaskets of the safety relief valves and/or due to creep damage of the main steam line, and damage of the in-core monitor guide tubes due to buckling. - Direct corium leakage from the RPVs to the pedestal floors through the melt portions of the in-core monitor housings. - Alternative water injection by the fire trucks with large amount of leakages through the branch lines. - Partial load operation of the Reactor Core Isolation Cooling system and the High Pressure Coolant Injection system. - Gas leakage from the primary containment vessels to the reactor buildings due to over pressure than the design maximum value. - Thermal stratification in the suppression pool resulting in incomplete steam condensation in the pool. The accident progressions were analyzed with the newly developed physical models for the above issues. And also considering the qualitatively estimated core status based on the plant parameters measured after the accident, the current core status was assessed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Severe Accident Research Directions after Fukushima

The accidents at the Fukushima Daiichi nuclear power station in March of 2011 renewed interest globally in the nature, causes, and health and economic consequences of severe accidents involving core damage and containment impairment. As a result of these accidents, research has been conducted into the modeling and phenomenological understanding of the accidents at Fukushima and the response and effectiveness of mitigating measures such as emergency water injection, primary system depressurization and containment venting actions. An important example of this is the jointly conducted OECD-NEA organized Benchmark of the Fukushima Accidents (BSAF project) where accident reconstruction analyses using computer codes such as MELCOR and MAAP are ongoing. Even prior to the Fukushima accidents, the Sandia/NRC sponsored State of Art Reactor Consequence Analyses (SOARCA) foreshadowed the accidents in Japan where long-term and short-term station blackout accidents in boiling water reactors with Mark-1 containment were analyzed showing striking similarities to the accidents at Fukushima. These analyses also highlighted important differences in our prior understanding, in particular the importance of suppression pool thermal stratification and the extraordinary operation of the Fukushima Unit-2 reactor core isolation cooling (RCIC) system, prompting addition research into both of these areas. Additionally, the focus of the world's major computer codes on modeling the Fukushima accidents in the BSAF effort, led to several 'Crosswalk' comparisons between code predictions, highlighting subtle but important modeling differences between the codes and identifying areas where modeling improvements can be made. Collectively, these research areas are aimed at improving our understanding of severe accident progression and real-world response of safety related systems and components, and should lead to improved accident response and mitigation capabilities in the future. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analytical Models for Terry Turbine Nozzle

As part of the efforts to understand the unexpected 'self-regulating' mode of the RCIC (Reactor Core Isolation Cooling) systems in Fukushima accidents and extend BWR RCIC and PWR AFW (Auxiliary Feed Water) operational range and flexibility, mechanistic models for the Terry turbine should be developed and implemented in reactor system analysis or severe accident codes. The Terry turbine has been used for all the BWR RCIC systems and for PWR AFW (Auxiliary Feed Water) systems. The Terry turbine is essentially a solid cylindrical wheel with multiple machined semi-circular 'buckets' that are shaped into the body of the wheel. Fixed nozzles and reversing chambers surround the wheel inside the turbine casing. High pressure steam is accelerated to supersonic flow inside the turbine nozzle. The kinetic energy is then converted to shaft work by the impulse force on the turbine buckets. A Fully implicit and strongly coupled RCIC system model has been developed in the RELAP-7 code and used for simplified BWR SBO (Station Black-Out) simulations in the past. In this model, a generic turbine model was used to conserve mass and energy while turbine operation characteristic curves were used to obtain non-dimensional mass flow rate and thermal efficiency. This model could be used for simulating RCIC off-design behavior if off-design operation characteristic curves were available. However, No such curves currently exist for the Terry turbine system due to its unique pure impulse design. A set of mechanistic Terry turbine models suitable for system code implementation has recently been developed by Sandia National Labs. In the Sandia model, the turbine bucket inlet velocity is provided according to a reduced-order model which was obtained from a large number of CFD simulations. In this paper, we propose an alternative method, using an under-expanded jet model to obtain the velocity and thermodynamic conditions for the turbine bucket inlet. These sets of analytical models are simple and generic, and suitable for use in system analysis codes. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Self-Excitation and Feedback Cooling of an Isolated Proton

The first one-proton self-excited oscillator (SEO) and one-proton feedback cooling are demonstrated. In a Penning trap with a large magnetic gradient, the SEO frequency is resolved to the high precision needed to detect a one-proton spin flip. This is after undamped magnetron motion is sideband cooled to a 14 mK theoretical limit, and despite random frequency shifts (typically larger than those from a spin flip) that take place every time sideband cooling is applied. The observations open a possible path towards a million-fold improved comparison of the p and p magnetic moments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design, implementation, and testing of a cryogenic loading capability on an engineering neutron diffractometer

A novel capability was designed, implemented, and tested for in situ neutron diffraction measurements during loading at cryogenic temperatures on the spectrometer for materials research at temperature and stress at Los Alamos National Laboratory. This capability allowed for the application of dynamic compressive forces of up to 250 kN on standard samples controlled at temperatures between 300 and 90 K. The approach comprised of cooling thermally isolated compression platens that in turn conductively cooled the sample in an aluminum vacuum chamber which was nominally transparent to the incident and diffracted neutrons. The cooling/heat rate and final temperature were controlled by regulating the flow of liquid nitrogen in channels inside the platens that were connected through bellows to the mechanical actuator of the load frame and by heaters placed on the platens. Various performance parameters of this system are reported here. The system was used to investigate deformation in Ni-Ti-Fe shape memory alloys at cryogenic temperatures and preliminary results are presented.

36 MATERIALS SCIENCE↗

Cooling, AGN feedback, and star formation in simulated cool-core galaxy clusters

Numerical simulations of active galactic nuclei (AGNs) feedback in cool-core galaxy clusters have successfully avoided classical cooling flows, but often produce too much cold gas. We perform adaptive mesh simulations that include momentum-driven AGN feedback, self-gravity, star formation, and stellar feedback, focusing on the interplay between cooling, AGN heating, and star formation in an isolated cool-core cluster. Cold clumps triggered by AGN jets and turbulence form filamentary structures tens of kpc long. This cold gas feeds both star formation and the supermassive black hole (SMBH), triggering an AGN outburst that increases the entropy of the intracluster medium (ICM) and reduces its cooling rate. Within 1–2 Gyr, star formation completely consumes the cold gas, leading to a brief shutoff of the AGN. The ICM quickly cools and redevelops multiphase gas, followed by another cycle of star formation/AGN outburst. Within 6.5 Gyr, we observe three such cycles. There is good agreement between our simulated cluster and the observations of cool-core clusters. ICM cooling is dynamically balanced by AGN heating, and a cool-core appearance is preserved. The minimum cooling time to free-fall time ratio typically varies between a few and ≳20. The star formation rate (SFR) covers a wide range, from 0 to a few hundred M{sub ⊙} yr{sup −1}, with an average of ∼40 M{sub ⊙} yr{sup −1}. The instantaneous SMBH accretion rate shows large variations on short timescales, but the average value correlates well with the SFR. Simulations without stellar feedback or self-gravity produce qualitatively similar results, but a lower SMBH feedback efficiency (0.1% compared to 1%) results in too many stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Isolation of major Venus thermospheric cooling mechanism and implications for earth and Mars

The additional cooling mechanism responsible for the unexpectedly cold dayside Venus thermosphere is isolated. Consideration is given not only to the condition that the calculated temperatures must be reduced to the observed dayside temperatures but also that the theoretical temperature variations must be in accord with the observed low amplitude of temperature variations associated with the 27-d variations of the sun. It is found that the low amplitude of the 27-d oscillations, combined with the cooling necessary for observed 300-K dayside temperatures, cannot be explained by eddy conduction cooling and can only be explained by very strong 15-micron cooling. Implications of the decrease in amplitude of the 11-yr Venus thermospheric variability due to the 15-micron thermostat effect are examined.

Keating, Gerald M.↗

A cryogenic seven-element HEMT front end for DSS 13

A cryogenically cooled Ka-band (33.6-GHz), seven-element front-end array for the DSN was built and tested. This system uses seven high electron mobility transistor (HEMT) low-noise amplifiers cooled by a two-stage closed-cycle refrigerator. All system components from the polarizers to the output isolators are cooled to a physical temperature between 18 and 35 K. The noise temperatures of the individual elements range from 64 to 84 K over a 2.75-GHz bandwidth.

Bowen, J.↗

A study of cooling time reduction of interferometric cryogenic gravitational wave detectors using a high-emissivity coating

In interferometric cryogenic gravitational wave detectors, there are plans to cool mirrors and their suspension systems (payloads) in order to reduce thermal noise, that is, one of the fundamental noise sources. Because of the large payload masses (several hundred kg in total) and their thermal isolation, a cooling time of several months is required. Our calculation shows that a high-emissivity coating (e.g. a diamond-like carbon (DLC) coating) can reduce the cooling time effectively by enhancing radiation heat transfer. Here, we have experimentally verified the effect of the DLC coating on the reduction of the cooling time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reverse Brayton Cycle with Bladeless Turbo Compressor for Automotive Environmental Cooling

An automotive cabin cooling system uses a bladeless turbocompressor driven by automobile engine exhaust to compress incoming ambient air. The compressed air is directed to an intercooler where it is cooled and then to another bladeless turbine used as an expander where the air cools as it expands and is directed to the cabin interior. Excess energy may be captured by an alternator couple to the expander turbine. The system employs no chemical refrigerant and may be further modified to include another intercooler on the output of the expander turbine to isolate the cooled cabin environment.

Cepeda-Rizo, Juan↗

STATUS OF MECHANICAL SLUDGE REMOVAL AND COOLING COILS CLOSURE AT THE SAVANNAH RIVER SITE - F TANK FARM CLOSURE PROJECT - 9225

The Savannah River Site F-Tank Farm Closure project has successfully performed Mechanical Sludge Removal using the Waste on Wheels (WOW) system within two of its storage tanks. The Waste on Wheels (WOW) system is designed to be relatively mobile with the ability for many components to be redeployed to multiple tanks. It is primarily comprised of Submersible Mixer Pumps (SMPs), Submersible Transfer Pumps (STPs), and a mobile control room with a control panel and variable speed drives. These tanks, designated as Tank 6 and Tank 5 respectively, are Type I waste tanks located in F-Tank Farm (FTF) with a capacity of 2839 cubic meters (750,000 gallons) each. In addition, Type I tanks have 34 vertically oriented cooling coils and two horizontal cooling coil circuits along the tank floor. DOE intends to remove from service and operationally close Tank 5 and Tank 6 and other HLW tanks that do not meet current containment standards. After obtaining regulatory approval, the tanks and cooling coils will be isolated and filled with grout for long term stabilization. Mechanical Sludge Removal of the remaining sludge waste within Tank 6 removed {approx} 75% of the original 25,000 gallons in August 2007. Utilizing lessons learned from Tank 6, Tank 5 Mechanical Sludge Removal completed removal of {approx} 90% of the original 125 cubic meters (33,000 gallons) of sludge material in May 2008. The successful removal of sludge material meets the requirement of approximately 19 to 28 cubic meters (5,000 to 7,500 gallons) remaining prior to the Chemical Cleaning process. The Chemical Cleaning Process will utilize 8 wt% oxalic acid to dissolve the remaining sludge heel. The flow sheet for Chemical Cleaning planned a 20:1 volume ratio of acid to sludge for the first strike with mixing provided by the submersible mixer pumps. The subsequent strikes will utilize a 13:1 volume ratio of acid to sludge with no mixing. The results of the Chemical Cleaning Process are detailed in the 'Status of Chemical Cleaning of Waste Tanks at the Savannah River Site--F Tank Farm Closure Project--Abstract 9114'. To support Tank 5 and Tank 6 cooling coil closure, cooling coil isolation and full scale cooling coil grout testing was completed to develop a strategy for grouting the horizontal and vertical cooling coils. This paper describes in detail the performance of the Mechanical Sludge Removal activities and SMP operational strategies within Tank 5. In addition, it will discuss the current status of Tank 5 & 6 cooling coil isolation activities and the results from the cooling coil grout fill tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and diagnosis of an atmospheric pressure plasma torch for investigating magnetohydrodynamic instabilities

The development and diagnosis of an atmospheric pressure, non-transferred, DC arc plasma torch for investigating magnetohydrodynamic experiments is presented. Utilizing a custom AC starter circuit coupled with a high power DC power supply a long, laminar plasma jet was successfully generated by adjusting voltage and current characteristics, gas flow rates, and torch geometry (nozzle diameter and length). A complete and detailed description of the design and operation conditions of our torch is presented such that our results may be reproduced. Utilizing copper, aluminum, and tungsten alloy electrode components in conjunction with an electrically isolated water cooling system allows for continuous torch operation. The 50 kV AC starter circuit is coupled with a 15 kW DC power supply via a series injection transformer as a part of the custom arc starter circuit components. Axial and tangential gas flow, with nitrogen as the working gas, is regulated to generate a stable, laminar, atmospheric plasma torch with a jet length of over 80 cm under ideal operating conditions. Here, to visualize the plasma interface in magnetohydrodynamics experiments, a technique was developed to image the cylindrical plasma jet in both the R-Z plane (axial) and R-θ plane (cross sectional) using planar-laser Mie scattering from particles added to the surrounding gas. Plasma emission wavelengths are filtered out allowing scattered light from the particle laden-flow field illuminated at 532 nm by an Nd:YAG laser, to be isolated. Plasma electron temperature and degree of ionization were estimated using a technique based on the well-known Fowler–Milne spectroscopic method. Electron temperatures of up to 14 000 K and degree of ionization up to 27% at the torch exit were obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiative cooling of Al{sub 4}{sup -} clusters

The radiative cooling of isolated, negatively charged four-atom aluminum clusters has been measured using an electrostatic ion beam trap. Stored Al{sub 4}{sup -} ions were irradiated by a short laser pulse at different times after their production in a hot ion source, and delayed electron emission was observed up to hundreds of microseconds after the laser pulse. The decay curves could be well reproduced using an Arrhenius decay law and allowed us to deduce the cluster temperatures at the time of the laser pulse. Using this sensitive molecular thermometer, the cluster temperature could be determined as a function of storage time. The radiation intensity is found to decrease from 40 eV/s at T=1400 K to 1 eV/s at 500 K with a temperature dependence as given by T{sup b} with b=3.5{+-}0.2--i.e., similar to what would be expected from a blackbody. This cooling behavior requires the presence of either electronic transitions or very collective infrared-active vibrations at transition energies around {approx}200 meV.

74 ATOMIC AND MOLECULAR PHYSICS↗

High Temperature 300°C Measurement While Drilling System

Many countries around the world, including the USA, have untapped geothermal energy potential. Enhanced Geothermal Systems (EGS) technology is needed to economically utilize this resource. Temperatures in some EGS reservoirs can exceed 300°C. To effectively utilize EGS resources, an array of injection and production wells must be accurately placed in the formation fracture network. Therefore, EGS can greatly benefit from a high temperature directional drilling system. Most commercial services for directional drilling systems are rated for 175°C while geothermal wells require operation at much higher temperatures. Two U.S. Department of Energy (DOE) Geothermal Technologies Office (GTO) projects have been initiated to develop a 300°C capable directional drilling system, the first developing a drill bit, directional motor, and drilling fluid (award number DE-EE0002782), and the second adding navigation and telemetry systems. This report is for the second project, “High Temperature 300°C Measurement While Drilling System”, award number DE-EE0005505. The “High Temperature 300°C Measurement While Drilling (MWD)” system complements the already developed drilling system with real time navigation capability. It is comprised of 175°C directional measurement electronics including the required sensors for measuring inclination and azimuth in 3 axes. It is embedded in a cooling and temperature isolation system to protect the electronics and sensors from the higher temperature outside the system, which can reach 300°C. Building the cooling and isolation system from non-magnetic materials and keeping a required distance to any magnetic component, such as alternator parts, ensures a high quality measurement of the earth’s magnetic field. This is required to achieve the specified navigation accuracy. The MWD system has a turbine driven alternator that is capable of delivering the required electrical energy to the electronic system at a 300°C borehole temperature. Measured data will be communicated to the surface by mud-pulse-telemetry. For this purpose the tool has a mud-pulse-valve that is controlled by the measurement electronics to establish a serial data communication via the mud stream. The mud-pulse-valve is also built to operate under 300°C borehole conditions. Three prototypes of the 300°C MWD were built and tested. These systems are available for a joint application with the previously developed 300°C drilling system, in a geothermal well.

15 GEOTHERMAL ENERGY↗

Energy-resolved and time-dependent unimolecular dissociation of hydroperoxyalkyl radicals (˙QOOH)

Hydroperoxyalkyl radicals (˙QOOH) are transient intermediates in the atmospheric oxidation of volatile organic compounds and combustion of hydrocarbon fuels in low temperature (<1000 K) environments. The carbon-centered ˙QOOH radicals are a critical juncture in the oxidation mechanism, but have generally eluded direct experimental observation of their structure, stability, and dissociation dynamics. Recently, this laboratory demonstrated that a prototypical ˙QOOH radical [˙CH 2 (CH 3 ) 2 COOH] can be synthesized by an alternative route, stabilized in a pulsed supersonic expansion, and characterized by its infrared (IR) spectroscopic signature and unimolecular dissociation rate to OH radical and cyclic ether products. The present study focuses on a partially deuterated ˙QOOD analog ˙CH 2 (CH 3 ) 2 COOD, generated in the laboratory by H-atom abstraction from partially deuterated tert-butyl hydroperoxide, (CH 3 ) 3 COOD. IR spectral features associated with jet-cooled and isolated ˙QOOD radicals are observed in the vicinity of the transition state (TS) barrier leading to OD radical and cyclic ether products. Furthermore, the overtone OD stretch (2ν OD ) of ˙QOOD is identified by IR action spectroscopy with UV laser-induced fluorescence detection of OD products. Direct time-domain measurement of the unimolecular dissociation rate for ˙QOOD (2ν OD ) extends prior rate measurements for ˙QOOH. Partial deuteration results in a small increase in the TS barrier predicted by high level electronic structure calculations due to changes in zero-point energies; the imaginary frequency is unchanged. Comparison of the unimolecular decay rates obtained experimentally with those predicted theoretically for both ˙QOOH and ˙QOOD confirm that unimolecular decay is enhanced by heavy-atom tunneling involving simultaneous O–O bond elongation and C–C–O angle contraction along the reaction pathway.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗