Antimicrobial resistance and genomic characterization of Salmonella Dublin isolates in cattle from the United States

Salmonella enterica subspecies enterica serotype Dublin is a host-adapted serotype in cattle, associated with enteritis and systemic disease. The primary clinical manifestation of Salmonella Dublin infection in cattle, especially calves, is respiratory disease. While rare in humans, it can cause severe illness, including bacteremia, with hospitalization and death. In the United States, S . Dublin has become one of the most multidrug-resistant serotypes. The objective of this study was to characterize S . Dublin isolates from sick cattle by analyzing phenotypic and genotypic antimicrobial resistance (AMR) profiles, the presence of plasmids, and phylogenetic relationships. S . Dublin isolates (n = 140) were selected from submissions to the NVSL for Salmonella serotyping (2014–2017) from 21 states. Isolates were tested for susceptibility against 14 class-representative antimicrobial drugs. Resistance profiles were determined using the ABRicate with Resfinder and NCBI databases, AMRFinder and PointFinder. Plasmids were detected using ABRicate with PlasmidFinder. Phylogeny was determined using vSNP. We found 98% of the isolates were resistant to more than 4 antimicrobials. Only 1 isolate was pan-susceptible and had no predicted AMR genes. All S . Dublin isolates were susceptible to azithromycin and meropenem. They showed 96% resistance to sulfonamides, 97% to tetracyclines, 95% to aminoglycosides and 85% to beta-lactams. The most common AMR genes were: sulf2 and tetA (98.6%), aph(6)-Id (97.9%), aph(3’’)-Ib, (97.1%), floR (94.3%), and blaCMY-2 (85.7%). All quinolone resistant isolates presented mutations in gyr A. Ten plasmid types were identified among all isolates with IncA/C2, IncX1, and IncFII(S) being the most frequent. The S . Dublin isolates show low genomic genetic diversity. This study provided antimicrobial susceptibility and genomic insight into S . Dublin clinical isolates from cattle in the U.S. Further sequence analysis integrating food and human origin S . Dublin isolates may provide valuable insight on increased virulence observed in humans.

60 APPLIED LIFE SCIENCES↗

NASA ground terminal communication equipment automated fault isolation expert systems

The prototype expert systems are described that diagnose the Distribution and Switching System I and II (DSS1 and DSS2), Statistical Multiplexers (SM), and Multiplexer and Demultiplexer systems (MDM) at the NASA Ground Terminal (NGT). A system level fault isolation expert system monitors the activities of a selected data stream, verifies that the fault exists in the NGT and identifies the faulty equipment. Equipment level fault isolation expert systems are invoked to isolate the fault to a Line Replaceable Unit (LRU) level. Input and sometimes output data stream activities for the equipment are available. The system level fault isolation expert system compares the equipment input and output status for a data stream and performs loopback tests (if necessary) to isolate the faulty equipment. The equipment level fault isolation system utilizes the process of elimination and/or the maintenance personnel's fault isolation experience stored in its knowledge base. The DSS1, DSS2 and SM fault isolation systems, using the knowledge of the current equipment configuration and the equipment circuitry issues a set of test connections according to the predefined rules. The faulty component or board can be identified by the expert system by analyzing the test results. The MDM fault isolation system correlates the failure symptoms with the faulty component based on maintenance personnel experience. The faulty component can be determined by knowing the failure symptoms. The DSS1, DSS2, SM, and MDM equipment simulators are implemented in PASCAL. The DSS1 fault isolation expert system was converted to C language from VP-Expert and integrated into the NGT automation software for offline switch diagnoses. Potentially, the NGT fault isolation algorithms can be used for the DSS1, SM, amd MDM located at Goddard Space Flight Center (GSFC).

Tang, Y. K.↗

Population genomics of the pathogenic yeast Candida tropicalis identifies hybrid isolates in environmental samples

Candida tropicalis is a human pathogen that primarily infects the immunocompromised. Whereas the genome of one isolate, C. tropicalis MYA-3404, was originally sequenced in 2009, there have been no large-scale, multi-isolate studies of the genetic and phenotypic diversity of this species. Here, we used whole genome sequencing and phenotyping to characterize 77 isolates of C. tropicalis from clinical and environmental sources from a variety of locations. We show that most C. tropicalis isolates are diploids with approximately 2–6 heterozygous variants per kilobase. The genomes are relatively stable, with few aneuploidies. However, we identified one highly homozygous isolate and six isolates of C. tropicalis with much higher heterozygosity levels ranging from 36–49 heterozygous variants per kilobase. Our analyses show that the heterozygous isolates represent two different hybrid lineages, where the hybrids share one parent (A) with most other C. tropicalis isolates, but the second parent (B or C) differs by at least 4% at the genome level. Four of the sequenced isolates descend from an AB hybridization, and two from an AC hybridization. The hybrids are MTLa/α heterozygotes. Hybridization, or mating, between different parents is therefore common in the evolutionary history of C. tropicalis. The new hybrids were predominantly found in environmental niches, including from soil. Hybridization is therefore unlikely to be associated with virulence. In addition, we used genotype-phenotype correlation and CRISPR-Cas9 editing to identify a genome variant that results in the inability of one isolate to utilize certain branched-chain amino acids as a sole nitrogen source.

59 BASIC BIOLOGICAL SCIENCES↗

A Vibration Isolation System for Use in a Large Thermal Vacuum Test Facility

A thermal vacuum payload platform that is isolated from background vibration is required to support the development of future instruments for Hubble Space Telescope (HST) and the Next Generation Space Telescope (NGST) at the Goddard Space Flight Center (GSFC). Because of the size and weight of the thermal/vacuum facility in which the instruments are tested, it is not practical to isolate the entire facility externally. Therefore, a vibration isolation system has been designed and fabricated to be installed inside the chamber. The isolation system provides a payload interface of 3.05 m (10 feet) in diameter and is capable of supporting a maximum payload weight of 4536 kg (10,000 Lbs). A counterweight system has been included to insure stability of payloads having high centers of gravity. The vibration isolation system poses a potential problem in that leakage into the chamber could compromise the ability to maintain vacuum. Strict specifications were imposed on the isolation system design to minimize leakage. Vibration measurements, obtained inside the chamber, prior to installing the vibration isolation system, indicated levels in all axes of approximately 1 milli-g at about 20 Hz. The vibration isolation system was designed to provide a minimum attenuation of 40 dB to these levels. This paper describes the design and testing of this unique vibration isolation system. Problems with leakage and corrective methods are presented. Isolation performance results are also presented.

Hershfeld, Donald↗

On component isolation of conceptual advanced reactors

Implementation of component isolation in nuclear industry is challenging due to gaps in research and the lack of specific guidelines. In this study, parameters affecting component-level isolation of advanced reactor vessels are identified based on a representative numerical model with explicit consideration of nonlinear soil-structure interaction (SSI). The objective of this study is to evaluate the effectiveness of, and to identify potential limitations of using conventional friction pendulum and lead-rubber bearings to seismically isolate vessels. It is found that slender vessels or components are particularly vulnerable to rotational accelerations at the isolation interface, which are caused by rotation of the sub-structure and by excitation of higher modes in the horizontal direction of the seismically isolated system. Component isolation is found to be more effective for relatively stiffer vessels and at sites with stiff soil properties. Considering that conventional isolators are deficient in resisting axial tension, it is observed that the optimum location for supporting a component to achieve seismic isolation, is at a cross-sectional plane passing through the center of mass of the vessel. These findings are corroborated by numerous simulations of the response of seismically isolated reactor vessels at different nuclear sites subject to a variety of ground motions.

99 GENERAL AND MISCELLANEOUS↗

Genomic Features of Antimicrobial Resistance in Staphylococcus pseudintermedius Isolated from Dogs with Pyoderma in Argentina and the United States: A Comparative Study

Staphylococcus pseudintermedius is the most common opportunistic pathogen in dogs and methicillin resistance (MRSP) has been identified as an emerging problem in canine pyoderma. Here, we evaluated the antimicrobial resistance (AMR) features and phylogeny of S. pseudintermedius isolated from canine pyoderma cases in Argentina (n = 29) and the United States (n = 29). 62% of isolates showed multi-drug resistance. The AMR genes found: mecA, blaZ, ermB, dfrG, catA, tetM, aac(6')-aph(2"), in addition to tetK and lnuA (only found in U.S. isolates). Two point mutations were detected: grlA(S80I)-gyrA(S84L), and grlA(D84N)-gyrA(S84L) in one U.S. isolate. A mutation in rpoB (H481N) was found in two isolates from Argentina. SCCmec type III, SCCmec type V, ΨSCCmec 57395 were identified in the Argentinian isolates; and SCCmec type III, SCCmec type IVg, SCCmec type V, and SCCmec type VII variant in the U.S. cohort. Sequence type (ST) ST71 belonging to a dominant clone was found in isolates from both countries, and ST45 only in Argentinian isolates. This is the first study to comparatively analyze the population structure of canine pyoderma-associated S. pseudintermedius isolates in Argentina and in the U.S. It is important to maintain surveillance on S. pseudintermedius populations to monitor AMR and gain further understanding of its evolution and dissemination.

60 APPLIED LIFE SCIENCES↗

Engine isolation for structural-borne interior noise reduction in a general aviation aircraft

Engine vibration isolation for structural-borne interior noise reduction is investigated. A laboratory based test procedure to simulate engine induced structure-borne noise transmission, the testing of a range of candidate isolators for relative performance data, and the development of an analytical model of the transmission phenomena for isolator design evaluation are addressed. The isolator relative performance test data show that the elastomeric isolators do not appear to operate as single degree of freedom systems with respect to noise isolation. Noise isolation beyond 150 Hz levels off and begins to decrease somewhat above 600 Hz. Coupled analytical and empirical models were used to study the structure-borne noise transmission phenomena. Correlation of predicted results with measured data show that (1) the modeling procedures are reasonably accurate for isolator design evaluation, (2) the frequency dependent properties of the isolators must be included in the model if reasonably accurate noise prediction beyond 150 Hz is desired. The experimental and analytical studies were carried out in the frequency range from 10 Hz to 1000 Hz.

Unruh, J. F.↗

A high-performance single-mode fiber-optic isolator assembly

A high-isolation single-mode fiber optic isolator assembly was designed and fabricated. The measured forward loss is 2.6 dB and the reverse loss (isolation) is greater than 70 dB. This is a 30-dB higher isolation than the isolation of the best fiber optic isolator previously reported. This isolator provides isolation between the semiconductor laser diode and the optical fiber in a precise reference frequency transmission system. The isolation of the laser greatly reduces the system's sensitivity to microphonics.

Lutes, G.↗

A 6 degree-of-freedom Lorentz force vibration isolator with nonlinear controller

This program demonstrated the technical feasibility of constructing large-stroke magnetic suspensions that can meet the active vibration isolation requirements of Space Station. These requirements include: (1) strokes over 1 cm in all directions, (2) actuator bandwidths over 100 Hz, (3) isolator roll-off frequencies below 10(exp -2) Hertz, and (4) force capability over 1 Newton in all axes. The 100 Hz actuator bandwidth allows the suspension to reject any direct force disturbances that act on the microgravity experiment, for example forces created by cable connections. The low isolator roll-off frequency and large stroke allow the magnetic suspension to isolate the microgravity experiment from Space Station vibrations above the roll-off frequency. The capability to meet these requirements was demonstrated by designing, constructing and testing a six-degree-of-freedom, prototype magnetic suspension system that featured high-performance, Lorentz-force actuators and full multi-input, multi-output control. This prototype suspension is designed to isolate large orbiter locker experiments under typical spacecraft constraints of size, weight, and power. Suspension in the full six-degrees-of-freedom was successfully demonstrated in this program while using a gravity-force unload mechanism to simulate a space environment. The prototype isolator is capable of space-based isolation service with relatively minor modification. The use of advanced, nonlinear control algorithms were investigated on a specially designed single-degree-of-freedom testbed. This low acceleration test facility simulates the Space Station vibration isolation problem in a single horizontal axis with low-friction, air-slide support. This allowed testing at the desired microgravity levels, without the gravity bias effects that are seen in a full six-degrees-of-freedom suspension. Precision components were used to reduce residual accelerations to microgravity levels so that the effects of sensor, actuator, and electronic noise could be evaluated. During the Phase 2 program, this testbed was used to demonstrate the advantages of nonlinear control algorithms to provide increased vibration isolation performance.

Fenn, Ralph↗

Presentation to International Space University Students on g-LIMIT and STABLE-ATD Projects and Related Microgravity Vibration Isolation Topics

Vibration isolation is a necessity in the development of science in space and especially those experiments destined for operation on the International Space Station (ISS). The premise of microgravity scientific research is that in space, disturbances are minimized and experiments can be conducted in the absence of gravity. Although microgravity conditions exist in space, disturbances are still present in various forms and can be detrimental to the success of a microgravity experiment. Due to the plethora of disturbances and the various types that will occur on the space station, the microgravity community has elected to incorporate various means of isolating scientific payloads from these unwanted vibrations. Designing these vibration isolators is a crucial task to achieve true microgravity science. Since conventional methods of isolating payloads can achieve only limited isolation, new technologies are being developed to achieve the goal of designing a generic vibration isolation system. One such system being developed for the Microgravity Science Glovebox (MSG) is called g-LIMIT which stands for Glovebox Integrated Microgravity Isolation Technology. The g-LIMIT system is a miniaturized active vibration isolator for glovebox experiments. Although the system is initially developed for glovebox experiments, the g-LIMIT technology is designed to be upwardly scaleable to provide isolation for a broad range of users. The g-LIMIT system is scheduled to be flown on the UF-2 mission in August of the year 2000 and will be tested shortly thereafter. Once the system has been fully qualified, the hardware will become available for other researchers and will provide a platform upon which the goal of microgravity science can be achieved.

Alhorn, Dean↗

A Sub-Hertz, Low-Frequency Vibration Isolation Platform

One of the major technical problems deep-space optical communication (DSOC) systems need to solve is the isolation of the optical terminal from vibrations produced by the spacecraft navigational control system and by the moving parts of onboard instruments. Even under these vibration perturbations, the DSOC transceivers (telescopes) need to be pointed l000 fs of times more accurately than an RF communication system (parabolic antennas). Mechanical resonators have been extensively used to provide vibration isolation for groundbased, airborne, and spaceborne payloads. The effectiveness of these isolation systems is determined mainly by the ability of designing a mechanical oscillator with the lowest possible resonant frequency. The Low-Frequency Vibration Isolation Platform (LFVIP), developed during this effort, aims to reduce the resonant frequency of the mechanical oscillators into the sub-Hertz region in order to maximize the passive isolation afforded by the 40 dB/decade roll-off response of the resonator. The LFVIP also provides tip/tilt functionality for acquisition and tracking of a beacon signal. An active control system is used for platform positioning and for dampening of the mechanical oscillator. The basic idea in the design of the isolation platform is to use a passive isolation strut with an approximately equal to 100-mHz resonance frequency. This will extend the isolation range to lower frequencies. The harmonic oscillator is a second-order lowpass filter for mechanical disturbances. The resonance quality depends on the dissipation mechanisms, which are mainly hysteretic because of the low resonant frequency and the absence of any viscous medium. The LFVIP system is configured using the well-established Stewart Platform, which consists of a top platform connected to a base with six extensible struts (see figure). The struts are attached to the base and to the platform via universal joints, which permit the extension and contraction of the struts. The struts ends are connected in pairs to the base and to the platform, forming an octahedron. The six struts provide the vibration isolation due to the properties of mechanical oscillators that behave as second-order lowpass filters for frequencies above the resonance. At high frequency, the ideal second-order low-pass filter response is spoiled by the distributed mass and the internal modes of membrane and of the platform with its payload.

Ortiz, Gerardo, G.↗

Vapor-barrier Vacuum Isolation System

A system includes a collimated beam source within a vacuum chamber, a condensable barrier gas, cooling material, a pump, and isolation chambers cooled by the cooling material to condense the barrier gas. Pressure levels of each isolation chamber are substantially greater than in the vacuum chamber. Coaxially-aligned orifices connect a working chamber, the isolation chambers, and the vacuum chamber. The pump evacuates uncondensed barrier gas. The barrier gas blocks entry of atmospheric vapor from the working chamber into the isolation chambers, and undergoes supersonic flow expansion upon entering each isolation chamber. A method includes connecting the isolation chambers to the vacuum chamber, directing vapor to a boundary with the working chamber, and supersonically expanding the vapor as it enters the isolation chambers via the orifices. The vapor condenses in each isolation chamber using the cooling material, and uncondensed vapor is pumped out of the isolation chambers via the pump.

Weinstein, Leonard M.↗

GOES-R Dual Isolation

The Geostationary Operational Environmental Satellite-R Series (GOES-R) is the first of the next generation geostationary weather satellites, scheduled for delivery in late 2015. GOES-R represents a quantum increase in Earth and solar weather observation capabilities, with 4 times the resolution, 5 times the observation rate, and 3 times the number of spectral bands for Earth observations. With the improved resolution, comes the instrument suite's increased sensitive to disturbances over a broad spectrum 0-512 Hz. Sources of disturbance include reaction wheels, thruster firings for station keeping and momentum management, gimbal motion, and internal instrument disturbances. To minimize the impact of these disturbances, the baseline design includes an Earth Pointed Platform (EPP), a stiff optical bench to which the two nadir pointed instruments are collocated together with the Guidance Navigation & Control (GN&C) star trackers and Inertial Measurement Units (IMUs). The EPP is passively isolated from the spacecraft bus with Honeywell D-Strut isolators providing attenuation for frequencies above approximately 5 Hz in all six degrees-of-freedom. A change in Reaction Wheel Assembly (RWA) vendors occurred very late in the program. To reduce the risk of RWA disturbances impacting performance, a secondary passive isolation system manufactured by Moog CSA Engineering was incorporated under each of the six 160 Nms RWAs, tuned to provide attenuation at frequencies above approximately 50 Hz. Integrated wheel and isolator testing was performed on a Kistler table at NASA Goddard Space Flight Center. High fidelity simulations were conducted to evaluate jitter performance for four topologies: 1) hard mounted no isolation, 2) EPP isolation only, 2) RWA isolation only, and 4) dual isolation. Simulation results demonstrate excellent performance relative to the pointing stability requirements, with dual isolated Line of Sight (LOS) jitter less than 1 micron rad.

GN&C Engineering↗

Three-Dimensional Vibration Isolator for Suppressing High-Frequency Responses for Sage III Contamination Monitoring Package (CMP)

The Stratospheric Aerosol and Gas Experiment (SAGE) III - International Space Station (ISS) instrument will be used to study ozone, providing global, long-term measurements of key components of the Earth's atmosphere for the continued health of Earth and its inhabitants. SAGE III is launched into orbit in an inverted configuration on SpaceX;s Falcon 9 launch vehicle. As one of its four supporting elements, a Contamination Monitoring Package (CMP) mounted to the top panel of the Interface Adapter Module (IAM) box experiences high-frequency response due to structural coupling between the two structures during the SpaceX launch. These vibrations, which were initially observed in the IAM Engineering Development Unit (EDU) test and later verified through finite element analysis (FEA) for the SpaceX launch loads, may damage the internal electronic cards and the Thermoelectric Quartz Crystal Microbalance (TQCM) sensors mounted on the CMP. Three-dimensional (3D) vibration isolators were required to be inserted between the CMP and IAM interface in order to attenuate the high frequency vibrations without resulting in any major changes to the existing system. Wire rope isolators were proposed as the isolation system between the CMP and IAM due to the low impact to design. Most 3D isolation systems are designed for compression and roll, therefore little dynamic data was available for using wire rope isolators in an inverted or tension configuration. From the isolator FEA and test results, it is shown that by using the 3D wire rope isolators, the CMP high-frequency responses have been suppressed by several orders of magnitude over a wide excitation frequency range. Consequently, the TQCM sensor responses are well below their qualification environments. It is indicated that these high-frequency responses due to the typical instrument structural coupling can be significantly suppressed by a vibration passive control using the 3D vibration isolator. Thermal and contamination issues were also examined during the isolator selection period for meeting the SAGE III-ISS instrument requirements.

Li, Y.↗

A structure-preserving machine learning framework for accurate prediction of structural dynamics for systems with isolated nonlinearities

The nonlinearities present in structural systems are often found in isolated regions within the structure, such as those containing joints or interfaces. However, despite the localized nature of these nonlinearities their presence serves to couple together the modes of the underlying linear system and significantly complicate the development of appropriate reduced-order models; the localized nonlinearities have a global effect on the dynamics of the system. Further, in the presence of evolving structural health the nonlinearities can arise from accumulating damage, with dynamics distinct from those observed in the healthy state. The present work develops a data-driven formulation to identify and include the contributions of the isolated nonlinearities on the dynamics of the underlying linear structure. A novel coordinate separation is developed that decomposes those nonlinearities restricted to the isolated subdomain from the known linear system defined over the entire domain, and the influence of the isolated nonlinearities is reintroduced as an appropriately identified traction at the boundary of the isolated subdomain, referred to as the deviatoric force. In the region exterior to the nonlinear subdomain the response of the ideal linear system recovers that of the original nonlinear system. In this work, the deviatoric force component is predicted using a structure-preserving multilayer perceptron, based only on measured responses at the boundary of the isolated subdomain. Therefore introduction of the perceptron is able to bypass the direct numerical simulation of the nonlinearities within the isolated subdomain. This approach is illustrated through a simple structural system in which an interior region contains cubic nonlinearities and hysteretic damping. Once trained, the machine learning system is able to accurately predict the deviatoric force so that the ideal system recovers the response of the original system in the region outside the isolated nonlinear subdomain. Moreover, the data-driven approach is able to accurately predict the response when the system is subject to differing initial conditions and external excitation without the need for retraining, so that the proposed approach provides a robust description of the structural dynamics of the overall system.

Machine learning↗

Revisiting the guidelines for ending isolation for COVID-19 patients

Since the start of the COVID-19 pandemic, two mainstream guidelines for defining when to end the isolation of SARS-CoV-2-infected individuals have been in use: the one-size-fits-all approach (i.e. patients are isolated for a fixed number of days) and the personalized approach (i.e. based on repeated testing of isolated patients). We use a mathematical framework to model within-host viral dynamics and test different criteria for ending isolation. By considering a fixed time of 10 days since symptom onset as the criterion for ending isolation, we estimated that the risk of releasing an individual who is still infectious is low (0–6.6%). However, this policy entails lengthy unnecessary isolations (4.8–8.3 days). In contrast, by using a personalized strategy, similar low risks can be reached with shorter prolonged isolations. The obtained findings provide a scientific rationale for policies on ending the isolation of SARS-CoV-2-infected individuals.

Jeong, Yong Dam↗

Design and test of aircraft engine isolators for reduced interior noise

Improved engine vibration isolation was proposed to be the most weight and cost efficient retrofit structure-borne noise control measure for single engine general aviation aircraft. A study was carried out the objectives: (1) to develop an engine isolator design specification for reduced interior noise transmission, (2) select/design candidate isolators to meet a 15 dB noise reduction design goal, and (3) carry out a proof of concept evaluation test. Analytical model of the engine, vibration isolators and engine mount structure were coupled to an empirical model of the fuselage for noise transmission evaluation. The model was used to develop engine isolator dynamic properties design specification for reduced noise transmission. Candidate isolators ere chosen from available product literature and retrofit to a test aircraft. A laboratory based test procedure was then developed to simulate engine induced noise transmission in the aircraft for a proof of concept evaluation test. Three candidate isolator configurations were evaluated for reduced structure-borne noise transmission relative to the original equipment isolators.

Unruh, J. F.↗

Vibration isolation technology development to demonstration

The main thrust of these studies has resulted in an active inertial feedforward/feedback isolation system. This prototype magnetic suspension system has been demonstrated in a laboratory setting in six degrees-of-freedom and has been preliminarily characterized in its isolation performance with favorable results. This isolation system consists of a closed loop digital control system referencing a platform around six relative and six inertial sensors. These sensors control the isolated mass through nine attractive electromagnetic actuators with a system capability of +/- three-tenths of an inch travel in three dimensions. The development of a prototype system from design to fabrication leads directly into the demonstration phase of the project which will attempt a low gravity environmental demonstration of engineering hardware for the isolation of a scientific payload. The demonstration phase of the project will use an aircraft low gravity maneuver to establish a research testbed for the study of isolation hardware and control strategies in an off-loaded environment. In developing this demonstration capability the Lewis Learjet aircraft has been characterized through its parabolic flight maneuvers and a trunnioned experimental volume has been designed for the test of both active and passive isolation packages. This vibration isolation testbed is operational and has two data acquisition systems available for both autonomous and interactive operation, with a combined input capability of 32 channels.

Grodsinsky, Carlos↗