Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion trap”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Design and fabrication of ion traps for low RF power dissipation

Large surface-electrode ion traps with multiple trapping regions and junctions are a natural approach to scaling trapped ion quantum computers, supporting the connectivity and ion counts necessary for complex quantum algorithms. However, a major hurdle in this scaling is on-chip power dissipation from the applied RF voltage, which increases at a rate between linear and cubic relative to trap size, depending on whether the losses are dielectric or Ohmic. Here, we present two versions of a trap with features designed to reduce both types of RF power dissipation. The first variant contains a raised RF electrode that increases the electrode–ground distance to reduce capacitance. Different DC voltage sources are demonstrated on this trap to show that technical noise before the filter remains the dominant source of voltage noise and therefore motional heating. The second variant additionally includes a method for removing dielectric from beneath the RF electrode to further reduce dielectric losses. These traps were demonstrated at room temperature with 40 Ca + ions. In conclusion, the similar heating rates and heating rate axial frequency dependencies between 2.4 and 3.0 MHz illustrate that this dielectric modification is not detrimental to trap performance.

Sterk, J. D. [Sandia National Laboratories (SNL-NM↗

YbH + formation in an ytterbium ion trap

The trapped 171 Yb + ion is a promising candidate for portable atomic clock applications. However, with buffer-gas cooled ytterbium ions, the ions can be pumped into a low-lying 2 F 7 / 2 state or form YbH + molecules. These dark states reduce the fluorescence signal from the ions and can degrade the clock stability. In this work, we study the dynamics of the populations of the 2 F 7 / 2 state and YbH + molecules under different operating conditions of our 171 Yb + ion system. Our study indicates that 2 F 7 / 2 -state ions can form YbH + molecules through interactions with hydrogen gas. As observed previously, dissociation of YbH + is observed at wavelengths around 369 nm. We also demonstrate YbH+ dissociation using 405 nm light. Moreover, we show that the population in the dark states can be limited by using a single repump laser at 935 nm. Our study provides insights into the molecular formation in a trapped ion system.

74 ATOMIC AND MOLECULAR PHYSICS↗

Hg-201 (+) CO-Magnetometer for HG-199(+) Trapped Ion Space Atomic Clocks

Local magnetic field strength in a trapped ion atomic clock is measured in real time, with high accuracy and without degrading clock performance, and the measurement is used to compensate for ambient magnetic field perturbations. First and second isotopes of an element are co-located within the linear ion trap. The first isotope has a resonant microwave transition between two hyperfine energy states, and the second isotope has a resonant Zeeman transition. Optical sources emit ultraviolet light that optically pump both isotopes. A microwave radiation source simultaneously emits microwave fields resonant with the first isotope's clock transition and the second isotope's Zeeman transition, and an optical detector measures the fluorescence from optically pumping both isotopes. The second isotope's Zeeman transition provides the measure of magnetic field strength, and the measurement is used to compensate the first isotope's clock transition or to adjust the applied C-field to reduce the effects of ambient magnetic field perturbations.

Burt, Eric A.↗

Extended linear ion trap frequency standard apparatus

A linear ion trap for frequency standard applications is provided with a plurality of trapping rods equally spaced and applied quadruple rf voltages for radial confinement of atomic ions and biased level pins at each end for axial confinement of the ions. The trapping rods are divided into two linear ion trap regions by a gap in each rod in a common radial plane to provide dc discontinuity, thus dc isolating one region from the other. A first region for ion-loading and preparation fluorescence is biased with a dc voltage to transport ions into a second region for resonance frequency comparison with a local oscillator derived frequency while the second region is held at zero voltage. The dc bias voltage of the regions is reversed for transporting the ions back into the first region for fluorescence measurement. The dual mode cycle is repeated continuously for comparison and feedback control of the local oscillator derived frequency. Only the second region requires magnetic shielding for the resonance function which is sensitive to any ambient magnetic fields.

Prestage, John D.↗

High-resolution vibrational predissociation spectroscopy of I - ·H 2 O by single-mode CW infrared excitation in a 3D cryogenic ion trap

We describe the integration of a tunable, single-mode, continuous wave infrared laser into a cryogenic ion spectroscopy experiment to measure the rovibrational spectrum of the I - ∙H 2 O complex in the OH stretching region. These upper levels lie about 300 cm -1 above the dissociation threshold. The measurements are carried out by loading the ions in a radiofrequency ion trap at 10 Hz and cooling them to 5 K with pulsed He buffer gas. IR photodissociation (PD) of the I - ∙H 2 O complex is monitored by recording the I - product yield by time-of-flight mass spectrometry as a function of laser wavelength. Very narrow (Δν~75 MHz) rotational lines are observed throughout the spectrum, indicating long (ca. 2 ns) lifetimes for the excited metastable rovibrational levels. Rotational analysis of the band arising from the K”=1 to K’=2 transition of the free OH stretching fundamental yields the structure of the complex for the first time. Over 50% of the trapped ion ensemble in the trap can be photodissociated upon excitation of a single rotational line. This enables very high signal-to-noise in the PD spectrum, and is traced to a mechanism in which the ground state rotational levels are rapidly equilibrated by collisions with the buffer gas.

74 ATOMIC AND MOLECULAR PHYSICS↗

Studying Open Quantum Systems Relevant to Chemistry on a Trapped-Ion Quantum Simulator (Final Technical Report)

This project advances the trapped-ion quantum simulator as a versatile platform for studying open quantum system phenomena. We aim to contribute to the emerging quantum simulation toolkits and enable simulation of nanoscale energy processes. Trapped-ion platforms offer unique capabilities: their vibrational motion can be precisely manipulated, measured, and coherently coupled to auxiliary qubits. The vibrational mode can function both as a highly sensitive quantum sensor and a programmable environment bath. Using this platform, we achieved three major outcomes. First, we demonstrated using the vibrational mode as an ultrasensitive probe for testing fundamental physics, including possible nonlinear quantum mechanics effects. Second, we established that these modes can act as controllable baths in which tunable noise and loss can enhance or modify energy-transfer dynamics, providing the experimental preparation toward studying mechanisms relevant to chemical reactions and light-harvesting systems. Third, by introducing controllable nonlinear gain and loss, we showed theoretically how simulations using trapped ions can model vibrationally-assisted energy transport in a non‐Hermitian quantum system comprising a chromophore dimer weakly coupled to a vibrational mode. Exploring the non‐Hermitian dynamics of the whole system including vibrations, we found that energy transfer accompanied by absorption of phonons from a vibrational mode can be significantly enhanced near an exceptional point. This theoretical work on simulation of energy transfer processes in driven non‐Hermitian quantum systems revealed an interesting novel path to study open quantum systems dynamics under conditions of gain and loss. We then further explored the benefits of controllable gain and loss with an experimental realization of quantum analogs of nonlinear oscillators, namely, the van der Pol oscillator. Here we observed mutual synchronization mediated by collective dissipation between two oscillators. In parallel, we explored related quantum networking protocols using the same trapped-ion platform, developing fast, high-fidelity schemes for distributing entanglement. Together, these achievements show that trapped-ion vibrational modes provide a highly programmable and high-fidelity platform for investigating complex dissipative quantum behavior, while enabling new approaches to remote quantum sensing, energy science, and nonlinear quantum dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Systems and Methods for Ejection of Ions from an Ion Trap

The invention generally relates to systems and methods for ejection of ions from an ion trap. In certain embodiments, systems and methods of the invention sum two different frequency signals into a single summed signal that is applied to an ion trap. In other embodiments, an amplitude of a single frequency signal is modulated as the single frequency signal is being applied to the ion trap. In other embodiments, a first alternating current (AC) signal is applied to an ion trap that varies as a function of time, while a constant radio frequency (RF) signal is applied to the ion trap.

Cooks, Robert Graham↗

Broadening of the drumhead-mode spectrum due to in-plane thermal fluctuations of two-dimensional trapped ion crystals in a Penning trap

Two-dimensional crystals of ions stored in Penning traps are a leading platform for quantum simulation and sensing experiments. For small amplitudes, the out-of-plane motion of such crystals can be described by a discrete set of normal modes called the drumhead modes, which can be used to implement a range of quantum information protocols. However, experimental observations of crystals with Doppler-cooled and even nearground- state-cooled drumhead modes reveal an unresolved drumhead-mode spectrum. In this work, we establish in-plane thermal fluctuations in ion positions as a major contributor to the broadening of the drumhead-mode spectrum. In the process, we demonstrate how the confining magnetic field leads to unconventional in-plane normal modes, whose average potential and kinetic energies are not equal. This property, in turn, has implications for the sampling procedure required to choose the in-plane initial conditions for molecular-dynamics simulations. Further, for current operating conditions of the NIST Penning trap, our study suggests that the two-dimensional crystals produced in this trap undergo in-plane potential-energy fluctuations of the order of 10mK. Our study therefore motivates the need for designing improved techniques to cool the in-plane degrees of freedom.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The streaming-trapped ion interface in the equatorial inner magnetosphere

Spacecraft measurements of core ions on L=4-7 field-lines typically show trapped ion distributions near the magnetic equator, and frequently indicate field-aligned ion streams at higher latitudes. The nature of the transition between them may indicate both the microphysics of hot-cold plasma interactions and overall consequences for core plasma evolution. We have undertaken a statistical analysis and characterization of this interface and its relation to the equatorial region of the inner magnetosphere. In this analysis, we have characterized such features as the equatorial ion flux anisotropy, the penetration of field-aligned ionospheric streams into the equatorial region, the scale of the transition into trapped ion populations, and the transition latitude. We found that most transition latitudes occur within 13 deg of the equator. The typical values of equatorial ion anisotropies are consistent with bi-Maxwellian temperature ratios of T(sub perpendicular)/T(sub parallel) in the range of 3-5. The latitudinal scales for the edges of the trapped ion populations display a rather strong peak in the 2-3 deg range. We also found that there is a trend for the penetration ratio, the anisotropy half width, and the transition scale length to decrease with a higher equatorial ion anisotropy. We may interpret these features in terms of Liouville mapping of equatorially trapped ions and the reflection of the incoming ionospheric ion streams from the equatorial potential peaks associated with such trapped ions.

Lin, J.↗

Mitigating the Effects of Au-Al Intermetallic Compounds Due to High-Temperature Processing of Surface-Electrode Ion Traps

Stringent physical requirements need to be met for the high-performing surface-electrode ion traps used in quantum computing and timekeeping. In particular, these traps must survive a high-temperature environment for vacuum chamber preparation and support high RF voltage on closely spaced electrodes. Due to the use of gold wire bonds on aluminum pads, intermetallic growth can lead to wire bond failure via breakage or high resistance, limiting the lifetime of a trap assembly to a single multiday bake at 200 ° C. Using traditional thick metal stacks to prevent intermetallic growth, however, can result in trap failure due to RF breakdown events. Through high-temperature experiments, we conclude that an ideal metal stack for ion traps is Ti/Pt/Au (20/100/250 nm), which allows for a cumulative bakeable time of roughly 86 days without compromising the trap voltage performance. This increase in the bakeable lifetime of ion traps will remove the need to discard otherwise functional ion traps when vacuum hardware is upgraded, which will greatly benefit ion trap experiments.

Haltli, Raymond A.↗

Bilayer Crystals of Trapped Ions for Quantum Information Processing

Trapped-ion systems are a leading platform for quantum information processing, but they are currently limited to 1D and 2D arrays, which imposes restrictions on both their scalability and their range of applications. Here, we propose a path to overcome this limitation by demonstrating that Penning traps can be used to realize remarkably clean bilayer crystals, wherein hundreds of ions self-organize into two well-defined layers. These bilayer crystals are made possible by the inclusion of an anharmonic trapping potential, which is readily implementable with current technology. We study the normal modes of this system and discover salient differences compared to the modes of single-plane crystals. The bilayer geometry and the unique properties of the normal modes open new opportunities—in particular, in quantum sensing and quantum simulation—that are not straightforward in single-plane crystals. Furthermore, we illustrate that it may be possible to extend the ideas presented here to realize multilayer crystals with more than two layers. Our work increases the dimensionality of trapped-ion systems by efficiently utilizing all three spatial dimensions, and it lays the foundation for a new generation of quantum information processing experiments with multilayer 3D crystals of trapped ions. Published by the American Physical Society 2024

Physics↗

Effects of ion trapping and fluctuations of electron temperature and plasma flow on cross-beam energy transfer

The influences of ion trapping and fluctuations of electron temperature and plasma flow on cross-beam energy transfer (CBET) are examined using two- and three-dimensional particle-in-cell simulations in parameter regimes relevant to recent CBET experiments at the OMEGA laser facility. In mid-Z plasma irradiated by an intense pump beam and weaker probe beam, ion trapping, collisional de-trapping, and plasma flow induced by thermal effects are shown to affect the CBET gain. Ion trapping can enhance or detune the CBET resonance [Nguyen et al., Phys. Plasmas 28, 082705 (2021)]. Collisional de-trapping can affect the CBET gain at low seed beam intensity near the onset threshold for ion trapping. Thermal-effects-induced flow can also detune the CBET resonance at a level comparable to that from trapping at low seed beam intensity. As a consequence, the CBET gain is sensitive to collisions and dimensionality at low seed beam intensity where ion trapping is weak but is insensitive to collisions and dimensionality at high seed beam intensity where ion trapping is strong.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-Time Quantitative Analysis of H2, He, O2, and Ar by Quadrupole Ion Trap Mass Spectrometry

The use of a quadrupole ion trap mass spectrometer for quantitative analysis of hydrogen and helium as well as other permanent gases is demonstrated. The customized instrument utilizes the mass selective instability mode of mass analysis as with commercial instruments; however, this instrument operates at a greater RF trapping frequency and without a buffer gas. With these differences, a useable mass range from 2 to over 50 Da is achieved, as required by NASA for monitoring the Space Shuttle during a launch countdown. The performance of the ion trap is evaluated using part-per-million concentrations of hydrogen, helium, oxygen and argon mixed into a nitrogen gas stream. Relative accuracy and precision when quantitating the four analytes were better than the NASA-required minimum of 10% error and 5% deviation, respectively. Limits of detection were below the NASA requirement of 25-ppm hydrogen and 100-ppm helium; those for oxygen and argon were slightly higher than the requirement. The instrument provided adequate performance at fast data recording rates, demonstrating the utility of an ion trap mass spectrometer as a real-time quantitative monitoring device for permanent gas analysis.

Ottens, Andrew K.↗

Four-Sector Cylindrical Radio-Frequency Ion Trap

Proposed linear radio-frequency ion trap consists of closed metal cylinder partitioned into four equal cylindrical-sector electrodes and two circular end electrodes. Features include relatively large ion-storage capacity and shielding against external fields. Used in frequency-standard laboratories to confine 199Hg+ ions electrodynamically in isolation from external environment. Similar to device described in "Linear Ion Trap for Atomic Clock" (NPO-17758).

Melbourne, Ruthann K.↗

Improved Linear-Ion-Trap Frequency Standard

Improved design concept for linear-ion-trap (LIT) frequency-standard apparatus proposed. Apparatus contains lengthened linear ion trap, and ions processed alternately in two regions: ions prepared in upper region of trap, then transported to lower region for exposure to microwave radiation, then returned to upper region for optical interrogation. Improved design intended to increase long-term frequency stability of apparatus while reducing size, mass, and cost.

Prestage, John D.↗

Motional Squeezing for Trapped Ion Transport and Separation

Transport, separation, and merging of trapped ion crystals are essential operations for most large-scale quantum computing architectures. In this Letter, we develop a theoretical framework that describes the dynamics of ions in time-varying potentials with a motional squeeze operator, followed by a motional displacement operator. Using this framework, we develop a new, general protocol for trapped ion transport, separation, and merging. We show that motional squeezing can prepare an ion wave packet to enable transfer from the ground state of one trapping potential to another. Here, the framework and protocol are applicable if the potential is harmonic over the extent of the ion wave packets at all times. As illustrations, we discuss two specific operations: changing the strength of the confining potential for a single ion and separating same-species ions with their mutual Coulomb force. Both of these operations are, ideally, free of residual motional excitation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme

The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250

Van Amerom, Friso H.↗

Operational Parameters, Considerations, and Design Decisions for Resource-Constrained Ion Trap Mass Spectrometers

Mass spectrometers are increasingly finding applications in new and unique areas, often in situations where key operational resources (i.e. power, weight and size) are limited. One such example is the Mars Organic Molecule Analyzer (MOMA). This instrument is a joint venture between NASA and the European Space Agency (ESA) to develop an ion trap mass spectrometer for chemical analysis on Mars. The constraints on such an instrument are significant as are the performance requirements. While the ideal operating parameters for an ion trap are generally well characterized, methods to maintain analytical performance with limited power and system weight need to be investigated and tested. Methods Experiments have been performed on two custom ion trap mass spectrometers developed as prototypes for the MOMA instrument. This hardware consists of quadrupole ion trap electrodes that are 70% the size of common commercial instrumentation. The trapping RF voltage is created with a custom tank circuit that can be tuned over a range of RF frequencies and is driven using laboratory supplies and amplifiers. The entire instrument is controlled with custom Lab VIEW software that allows a high degree of flexibility in the definition of the scan function defining the ion trap experiment. Ions are typically generated via an internal electron ionization source, however, a laser desorption source is also in development for analysis of larger intact molecules. Preliminary Data The main goals in this work have been to reduce the power required to generate the radio frequency trapping field used in an ion trap mass spectrometer. Generally minimizing the power will also reduce the volume and mass of the electronics to support the instrument. In order to achieve optimum performance, commercial instruments typically utilize RF frequencies in the 1 MHz range. Without much concern for power usage, they simply generate the voltage required to access the mass range of interest. In order to reduce the required RF voltage (and power), operation of the ion trap at lower RF frequencies has been investigated. Surprisingly, the performance of the instrument has only been slightly degraded at RF frequencies all the way down to 500 kHz. Mass resolution is relatively stable to this point and depending on the resonant ejection point used, the peak intensity is also quite stable. To date only masses up to m/z 200 have been fully investigated, however, additional studies are planned to verify the performance with higher mass ions. The lower frequency and voltage should reduce the pseudo potential well depth, eventually affecting the trapping efficiency of the instrument -- effect that could manifest itself in significantly limiting the mass range of trapped ions. Other methods to reduce the RF power while maintaining analytical performance are also under investigation. This includes ion ejection at lower q(sub z) values to access a given mass with a lower RF voltage. The loss of mass resolution at lower q(sub eject) points has been measured and current work is underway to leverage scan speed and the use of non-linear resonances in order to counter this trend. The overall trap performance under this range of operating conditions will be presented with a goal of identifying what trade-offs are acceptable.

Danell, Ryan M.↗