Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

CR-39 nuclear track detector response to inertial confinement fusion relevant ions

The detection properties of CR-39 were investigated for protons, deuterons, and tritons of various energies. Two models for the relationship between the track diameter and particle energy are presented and demonstrated to match experimental data for all three species. Data demonstrate that CR-39 has 100% efficiency for protons between 1 MeV and 4 MeV, deuterons between 1 MeV and 12.2 MeV, and tritons between 1 MeV and 10 MeV. The true upper bounds for deuterons and tritons exceed what could be measured in data. Simulations were developed to further explore the properties of CR-39 and suggest that the diameter–energy relationship of alpha particles cannot be captured by the conventional c-parameter model. These findings provide confidence in CR-39 track diameter based spectroscopy of all three species and provide invaluable insight for designing filtering for all CR-39 based diagnostics.

47 OTHER INSTRUMENTATION↗

Tracking the evolution of processes occurring in silicon anodes in lithium ion batteries by 3D visualization of relaxation times

An unconventional electroanalytical method has been used for tracking processes in silicon anodes in lithium ion batteries: a 3D visualization of relaxation times. Impedance data of the electrodes were collected at different potentials and different cycles during cyclic voltammetry, and were treated by means of the Distribution of Relaxation Times (DRT) method. A 3D visualization of the results allowed to identify the formation of a solid electrolyte interphase on the anode, composed of two layers with different relaxation times. Such findings are not possible by conventional analysis of impedance data by modeling with equivalent circuits, nor by simple DRT alone. Additionally, it was possible to observe that the characteristic relaxation time of the lithiation of the Si anode becomes smaller upon cycling, indicating that the material experiences structural transformations that allow it to lithiate faster. The result is relevant to motivate the use of micron-sized particles in the anode.

25 ENERGY STORAGE↗

Monte Carlo simulation of the passage of $\gamma$-rays and $\alpha$-particles in CsI

In this work, theoretical and computational methods for simulating the creation of ionization tracks by fast ions in solids were applied to the passage of a-particles in CsI, an inorganic scintillator commonly used for radiation detection. The methods were implemented in a Monte Carlo program to simulate the interaction of $\alpha$-particles, with incident energies of up to 1 MeV, with CsI. The simulations followed the fate of individual electron-hole pairs and thus allowed for a detailed description of the microscopic structure of ionization tracks created by incident radiation. Simulations were also performed with $\gamma$-rays of the same energy to compare and contrast the ionization tracks obtained with both types of particle. Intrinsic properties such as the mean energy per electron-hole pair, Fano factor, maximum theoretical light yield, and spatial distributions of electron-hole pairs were computed for both $\alpha$-particles and $\gamma$-rays. $\alpha$-particles created cylindrical tracks that were initially aligned with the incident direction and with initial radii of a few nanometers, whereas $\gamma$-rays showed significant scattering, resulting in probability distributions with lower intensities and much greater radial extents.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra low background time projection alpha particle detector ( Phase II Final Scientific/Technical Report)

When alpha particles are emitted into a gas they create an ionization track of gas ions and electrons. In our commercial UltraLo instrument we apply a voltage between a planar sample and an anode, integrate the anode signal as it collects the electrons, and distinguish between alphas emitted from the sample and elsewhere (anode, sidewalls) by the duration and shape of the resultant signal. The major contributors limiting the instrument’s lower detection limit are cosmic rays that pass through the detector close to the sample and Rn decays that produce charge tracks the originate in the gas and end on the sample. In this work we proposed to identify and reject these events by converting the anode into a multi-pixel array and operating in time projection mode. Cosmic rays would be eliminated by generating charge on many pixels, while charge collection asymmetry would distinguish between sample events (Bragg curve up) and Rn events (Bragg curve down). We therefore proposed to modify an UltraLo by pixilating its anode, developing low noise, low power multiplexed electronics to track each pixel’s signal individually, and develop analysis software to make the required discriminations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Decoupling the metal insulator transition and crystal field effects of VO 2

VO 2 is a highly correlated electron system which has a metal-to-insulator transition (MIT) with a dramatic change of conductivity accompanied by a first-order structural phase transition (SPT) near room temperature. The origin of the MIT is still controversial and there is ongoing debate over whether an SPT induces the MIT and whether the T c can be engineered using artificial parameters. We examined the electrical and local structural properties of Cr- and Co-ion implanted VO 2 (Cr-VO 2 and Co-VO 2 ) films using temperature-dependent resistance and X-ray absorption fine structure (XAFS) measurements at the V K edge. The temperature-dependent electrical resistance measurements of both Cr-VO 2 and Co-VO 2 films showed sharp MIT features. The T c values of the Cr-VO 2 and Co-VO 2 films first decreased and then increased relative to that of pristine VO 2 as the ion flux was increased. The pre-edge peak of the V K edge from the Cr-VO 2 films with a Cr ion flux ≥ 10 13 ions/cm 2 showed no temperature-dependent behavior, implying no changes in the local density of states of V 3d t 2g and e g orbitals during MIT. Extended XAFS (EXAFS) revealed that implanted Cr and Co ions and their tracks caused a substantial amount of structural disorder and distortion at both vanadium and oxygen sites. The resistance and XAFS measurements revealed that VO 2 experiences a sharp MIT when the distance of V–V pairs undergoes an SPT without any transitions in either the VO 6 octahedrons or the V 3d t 2g and eg states. This indicates that the MIT of VO 2 occurs with no changes of the crystal fields.

36 MATERIALS SCIENCE↗

Experimental and computational study of phase space dynamics in strongly coupled plasmas with steep density gradients

Understanding how plasmas thermalize when density gradients are steep remains a fundamental challenge in plasma physics, with direct implications for fusion experiments and astrophysical phenomena. Standard hydrodynamic models break down in these regimes, and kinetic theories make predictions that have never been directly tested. Here, we present the first detailed phase-space measurements of a strongly coupled plasma as it evolves from sharp density gradients to thermal equilibrium. Using laser-induced fluorescence imaging of an ultracold calcium plasma, we track the complete ion distribution function f(x,v,t). We discover that commonly used kinetic models (Bhatnagar–Gross–Krook and Lenard–Bernstein) overpredict thermalization rates, even while correctly capturing the initial counterstreaming plasma formation. Our measurements reveal that the initial ion acceleration response scales linearly with electron temperature, and that the simulations underpredict the initial ion response. In our geometry we demonstrate the formation of well-controlled counterpropagating plasma beams. This experimental platform enables precision tests of kinetic theories and opens new possibilities for studying plasma stopping power and flow-induced instabilities in strongly coupled systems.

Bergeson, Scott (ORCID:0000000231249226)↗

Charge lifetime improvement of the Continuous Electron Beam Accelerator Facility photogun with a biased anode

GaAs photocathodes in dc high-voltage photoguns are highly susceptible to ion back-bombardment, which reduces the photocathode quantum efficiency and limits the useful operating lifetime for producing polarized electron beams. This paper demonstrates that applying a small positive bias to the photogun anode can significantly suppress ion back-bombardment and increase charge lifetime. This technique was studied extensively using the Continuous Electron Beam Accelerator Facility photogun, where highly polarized electron beams created using a strained-superlattice GaAs / GaAsP photocathode were used and charge lifetimes improved by almost a factor of 2. A new simulation code was developed to model ion production and tracking in order to better understand and explain the factors that led to the performance improvement. Results of the experiments and simulations are discussed in detail. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Modelling the Alfvén eigenmode induced fast-ion flow measured by an imaging neutral particle analyzer

An imaging neutral particle analyzer (INPA) provides energy and radially resolved measurements of the confined fast-ion population ranging from the high-field side to the edge on the midplane of the DIII-D tokamak. In recent experiments, it was used to diagnose fast-ion flow in the INPA-interrogated phase-space driven by multiple, marginally unstable Alfvén eigenmodes (AEs). Here, the key features of this measured fast-ion flow are: (I) a fast-ion flow from q min and the injection energy (81 keV) towards lower energies and plasma periphery.(II) A flow from the same location towards higher energies and the plasma core, (III) a phase-space 'hole' at the injected energy and plasma core and (IV) a pile-up at the plasma core at lower energies (~60 keV). Ad hoc energetic particle diffusivity modelling of TRANSP significantly deviates from the observation. Comparably, a reduced modelling, i.e. a combination of NOVA-K and ASCOT5 code with the measured mode structure and amplitude, generally reproduce some key features of the observed phase-space flow, but largely failed to interpret fast ion depletion near the plasma axis. At last, self-consistent, first-principle multi-phase hybrid simulations that include realistic neutral beam injection and collisions are able to reproduce most features of the time-resolved phase-space flow. During consecutive hybrid phases, an RSAE consistent with the experiment grows and saturates, redistributing the injected fast ions. The resulting synthetic INPA images are in good agreement with the measurement near the injection energy. The simulations track the fast-ion redistribution within the INPA range, confirming that the measured fast-ion flow follows streamlines defined by the intersection of phase-space surfaces of constant magnetic moment μ and constant E' = nE + ωP φ , where n and ω are the instability toroidal mode number and frequency, and E and P φ the ion energy and toroidal canonical momentum. Nonperturbative effects are required to reproduce the depletion of fast ions near the magnetic axis at the injection energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hydroxyl radical yields in the heavy ion radiolysis of water

The yields of hydroxyl radicals in the radiolysis of water with protons and carbon ions have been examined using experimental scavenging techniques coupled with Monte Carlo track simulations. Combined with previous results using helium ions, this set of data gives valuable information on the potential for radiation induced damage to biological systems for light ions with very different track structures. Carbon dioxide production from aerated formic acid solutions in concentrations ranging from 10 -3 to 1 M was used as a probe of hydroxyl radical yields from about 8 ns to 8 µs. Numerical interpolation of the results at slightly different ion energies in combination with data from gamma radiolysis allows for a systematic analysis of both track average and track segment yields. As expected, considerable track chemistry is found to occur on the nanosecond to microsecond time scales. Monte Carlo track simulations employing stochastic diffusion-kinetic calculations of product yields are found to reproduce experimental observations satisfactorily. The track simulations are used to extract hydroxyl radical kinetics in pure water at neutral conditions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Coherence mapping to identify the intermediates of multi-channel dissociative ionization

Identifying the short-lived intermediates and reaction mechanisms of multi-channel radical cation fragmentation processes remains a current and important challenge to understanding and predicting mass spectra. We find that coherent oscillations in the femtosecond time-dependent yields of several product ions following ultrafast strong-field ionization represent spectroscopic signatures that elucidate their mechanism of formation and identify the intermediate(s) they originate from. Experiments on endo-dicyclopentadiene show that vibrational frequencies from various intermediates are mapped onto their resulting products. Aided by ab initio methods, we identify the vibrational modes of both the cleaved and intact molecular ion intermediates. These results confirm stepwise and concerted fragmentation pathways of the dicyclopentadiene ion. This study highlights the power of tracking the femtosecond dynamics of all product ions simultaneously and sheds further light onto one of the fundamental reaction mechanisms in mass spectrometry, the retro-Diels Alder reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of Compositional Complexity on Amorphization Resistance of Swift Heavy Ion Irradiated Titanate Pyrochlores

Compositionally complex oxides have garnered attention recently for their potential technological applications in harsh environments such as thermal barrier coatings and nuclear waste forms. Therefore, their response to extreme conditions, including high temperature and intense irradiation fields, must be thoroughly investigated. Here, the structural evolution of two pyrochlore oxides with comparable cation size ratio, r A /r B , (Yb 0.2 Er 0.2 Dy 0.2 Tb 0.2 Gd 0.2 ) 2 Ti 2 O 7 and Ho 2 Ti 2 O 7 , was evaluated after irradiation with 946 MeV Au ions up to a fluence of 8 × 10 12 ions/cm2 using synchrotron X-ray diffraction, transmission electron microscopy, and Raman spectroscopy. The overall radiation response is comparable for both titanate oxides and is dominated by a loss of crystallinity. When compared to a series of conventional titanate pyrochlore compositions, the amorphous track diameter of (Yb 0.2 Er 0.2 Dy 0.2 Tb 0.2 Gd 0.2 ) 2 Ti 2 O 7 is slightly larger than that of Ho2Ti2O7 and more in line with the diameter of the endmember with the maximum A-site cation size (Gd 2 Ti 2 O 7 ). Density functional theory calculations suggest that this behavior may be linked to local lattice distortions and the associated energetics of cation antisite formation. TEM and Raman analyses show that a disordered, crystalline shell surrounds the amorphous ion tracks in (Yb 0.2 Er 0.2 Dy 0.2 Tb 0.2 Gd 0.2 ) 2 Ti 2 O 7 , and the corresponding short-range structure resembles a weberite-type atomic arrangement.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating Ion Accumulation and Storage in Traveling Wave Based Structures for Lossless Ion Manipulations

Structures for lossless ion manipulations (SLIM) technology has demonstrated high resolving power ion mobility separation and flexibility to integrate complex ion manipulations into a single experimental platform. To enable IMS separations, trapping/accumulating ions inside SLIM (or in-SLIM) prior to injection of a packet for separations provides ease of operation and reduces the need for dedicated ion traps external to SLIM. To fully characterize the ion accumulation process, we have evaluated the effect of TW amplitudes, ion collection times, and storage times on the “in-SLIM” accumulation process. The study utilized a SLIM module comprising 5 distinct tracks, each with a specific ion accumulation configuration. The effect of the TW conditions on the accumulation process was investigated for a 3-peptide mixture: kemptide, angiotensin II, and neurotensin at a TW speed of 106 m/s. The effect of ion accumulation time/collection time and storage time was investigated, in addition to TW amplitude. Overall, the signal of the analyte ions increased when the ion collection time increased from 49 to 163 ms but decreased when the ion collection time increased further to 652 ms due to the space charge effects. Ion losses were observed at high TW amplitudes (e.g., 15 V p–p and 20 V p–p ). In addition, under space charge conditions (e.g., collection times of 163 and 652 ms), the signal of the analyte ions decreased with an increase in storage times for all TW amplitudes applied to the trapping region. For ion accumulation, the data indicate that gentler TW conditions must be utilized to minimize ion losses and fragments to benefit from the “in-SLIM” accumulation process. Finally, wider SLIM tracks provided better performance than those with narrower tracks.

59 BASIC BIOLOGICAL SCIENCES↗

EIC Physics from An All-Silicon Tracking Detector

The proposed electron-ion collider has a rich physics program to study the internal structure of protons and heavy nuclei. This program will impose strict requirements on detector design. This paper explores how these requirements can be satisfied using an all-silicon tracking detector, by consideration of three representative probes: heavy flavor hadrons, jets, and exclusive vector mesons.

Arrington, John↗

Fast ion confinement in quasi-axisymmetric stellarator equilibria

This report presents an initial analysis of the fast ion confinement and losses within quasi-axisymmetric stellarator equilibria in consideration by Thea Energy. The equilibria have not yet been explicitly optimized for fast particle confinement and require validation. Modeling with the ASCOT5 code is used to directly examine the fast ion transport. The particle tracking simulations are purely (neo)classical in nature and simply contain the supplied equilibrium and collisions (pitch-angle, energy slowing, and velocity diffusion) from supplied thermal profiles. Uniform marker deposition is used to probe the general confinement properties of the equilibria while a realistic beam-born population is provided from the BEAMS3D code and an alpha particle population is calculated from a fusion source integrator. A first wall is included and defines the loss boundary. Analysis for NBI ions within Thea Energy’s conceptual Eos neutron source are presented along with alpha particles in an enlarged DT-plasma. The fast ions are assessed in regards to their confinement time, pitch, energy, and spatial coordinates. For each population, the impact of collisions and orbit drifts are discussed. It is found that NBI born ions in Eos are strongly confined until slowing-down, owing largely to the tangential injection geometry, while 22% of DT-born alpha energy is lost in the scaled device, indicating that any fusion pilot plant design optimization should include metrics for fast ion confinement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and simulated performance of calorimetry systems for the ECCE detector at the electron ion collider

Here, we describe the design and performance the calorimeter systems used in the ECCE detector to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapidity range from -3.7 to 3.8 and two hadronic calorimeters covering a combined range of -1.1<η<3.8. Key calorimeter performances which include energy and position resolutions, reconstruction efficiency, and particle identification will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ionization detail parameters and cluster dose: a mathematical model for selection of nanodosimetric quantities for use in treatment planning in charged particle radiotherapy

Abstract Objective . To propose a mathematical model for applying ionization detail (ID), the detailed spatial distribution of ionization along a particle track, to proton and ion beam radiotherapy treatment planning (RTP). Approach . Our model provides for selection of preferred ID parameters ( I p ) for RTP, that associate closest to biological effects. Cluster dose is proposed to bridge the large gap between nanoscopic I p and macroscopic RTP. Selection of I p is demonstrated using published cell survival measurements for protons through argon, comparing results for nineteen I p : N k , k = 2, 3, …, 10, the number of ionizations in clusters of k or more per particle, and F k , k = 1, 2, …, 10, the number of clusters of k or more per particle. We then describe application of the model to ID-based RTP and propose a path to clinical translation. Main results . The preferred I p were N 4 and F 5 for aerobic cells, N 5 and F 7 for hypoxic cells. Significant differences were found in cell survival for beams having the same LET or the preferred N k . Conversely, there was no significant difference for F 5 for aerobic cells and F 7 for hypoxic cells, regardless of ion beam atomic number or energy. Further, cells irradiated with the same cluster dose for these I p had the same cell survival. Based on these preliminary results and other compelling results in nanodosimetry, it is reasonable to assert that I p exist that are more closely associated with biological effects than current LET-based approaches and microdosimetric RBE-based models used in particle RTP. However, more biological variables such as cell line and cycle phase, as well as ion beam pulse structure and rate still need investigation. Significance . Our model provides a practical means to select preferred I p from radiobiological data, and to convert I p to the macroscopic cluster dose for particle RTP.

Engineering↗