Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion mobility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Total hydrocarbon analysis by ion mobility spectrometry

Astronauts must be alerted quickly to chemical leaks that compromise their health and the success of their missions. An ideal leak detector would be equally sensitive to all compounds that might constitute a hazard and insensitive to nontoxic compounds. No ideal sensor exists; thus, selection of a methodology is a series of compromises. The commonly used methods are either insensitive at the low exposure levels set by OSHA, NASA, and other organizations or are selectively insensitive to important classes of chemicals such as Freons. After extensive study and experience, the Toxicology Group at JSC has selected ion mobility spectrometry (IMS) for development into a broad range, sensitive detector. In addition to the sensing method, signal processing is important leak detection because a background signal can be expected at all times. The leak-detecting instrument must be programmed to discriminate between authentic leaks and background fluctuations caused by routine operations. The results of an evaluation of the prototype THA is presented in terms related to spacecraft operations. The evaluation included determination of instrumental parameters such as stability and response times. We also included responses to some common components of spacecraft atmospheres in pure form and in binary and ternary mixtures. The output of the four algorithms to the mixtures was found to be noticeably different. These responses are compared on the basis of their utility for signaling a chemical leak. As a means of evaluating its resistance to a falsely positive response, the THA was challenged with carbon dioxide and methane, compounds whose concentrations normally increase in spacecraft air during human habitation. The instrument showed virtually no response to these interferences. Although the prototype THA is designed for space flight, this detector is expected to be useful for field screening at chemical waste dumps and other environmentally sensitive locations.

Cross, John H.↗

Miniature GC: Minicell ion mobility spectrometer (IMS) for astrobiology planetary missions

Astrobiology flight experiments require highly sensitive instrumentation for in situ analysis of volatile chemical species and minerals present in the atmospheres and surfaces of planets, moons, and asteroids. The complex mixtures encountered place a heavy burden on the analytical instrumentation to detect and identify all species present. The use of land rovers and balloon aero-rovers place additional emphasis on miniaturization of the analytical instrumentation. In addition, smaller instruments, using tiny amounts of consumables, allow the use of more instrumentation and/or longer mission life for stationary landers/laboratories. We describe here the development of a miniature GC - Minicell Ion Mobility Spectrometer (IMS) under development through NASA's Astrobiology Science and Technology Instrument Development (ASTID) Program and NASA's Small Business Innovative Research (SBIR) Program.

Kojiro, Daniel R.↗

A volatile organic analyzer for Space Station: Description and evaluation of a gas chromatography/ ion mobility

A Volatile Organic Analyzer (VOA) is being developed as an essential component of the Space Station's Environmental Health System (EHS) air quality monitoring strategy to provide warning to the crew and ground personnel if volatile organic compounds exceed established exposure limits. The short duration of most Shuttle flights and the relative simplicity of the contaminant removal mechanism have lessened the concern about crew exposure to air contaminants on the Shuttle. However, the longer missions associated with the Space Station, the complex air revitalization system and the proposed number of experiments have led to a desire for real-time monitoring of the contaminants in the Space Station atmosphere. Achieving the performance requirements established for the VOA within the Space Station resource (e.g., power, weight) allocations led to a novel approach that joined a gas chromatograph (GC) to an ion mobility spectrometer (IMS). The authors of this paper will discuss the rational for selecting the GC/IMS technology as opposed to the more established gas chromatography/mass spectrometry (GC/MS) for the foundation of the VOA. The data presented from preliminary evaluations will demonstrate the versatile capability of the GC/IMS to analyze the major contaminants expected in the Space Station atmosphere. The favorable GC/IMS characteristics illustrated in this paper included excellent sensitivity, dual-mode operation for selective detection, and mobility drift times to distinguish co-eluting GC peaks. Preliminary studies have shown that the GC/IMS technology can meet surpass the performance requirements of the Space Station VOA.

Limero, Thomas F.↗

The use of ion mobility spectrometry and gas chromatography/mass spectrometry for the detection of illicit drugs on clandestine records

Illicit drug distribution has over the past decade grown tremendously from simple 'drug pushing' where drugs were distributed from poorly organized individuals to today's well organized and well financed drug cartels. This change to a more 'corporate-like' atmosphere has resulted in a greater use of record keeping to monitor the profits generated. The use of record keeping by drug distributors is not restricted to high level drug smugglers but is used at all levels within the distribution network. Dealers at all levels including street dealers are generally 'fronted', given on consignment quantities of drugs that they in turn sell to customers, thereby requiring the need for records to keep track of drug sales versus liabilities. These records because of their illicit nature are often encrypted to hide the fact that they are indeed records of drug transactions. The creation of a handwritten notation concerning a drug transaction is normally brought on because of a purchase or sale. In a sale, this is commonly accomplished through a consignment, or the designation of a quantity to a customer to whom that amount has been 'fronted'. Because this activity generates a debt, it follows that an accounting for payments made, as well as new transactions completed, is only logical. One of the most common means of representing these is through an 'accounting flow', in which payments are subtracted from a running balance while new sales are added to it. The examination of illicit drug records has been the key to the prosecution of numerous federal, state, and local drug cases for a number of years. The Document Section of the FBI Laboratory, through its Racketeering Records Analysis Unit (RRAU), has been involved in such analytical efforts since 1983. Detailed analytical research brought about an evolution in the systematic approach utilized in the RRAU since that time. The close proximity of the drugs to the records often results in trace drug evidence being transferred to the records. The detection of trace drug residue on surfaces by ion mobility spectrometry (IMS) is well documented in literature. The following procedure will deal primarily with the newer techniques of trace drug analysis and drug record analysis developed by the Chemistry/Toxicology Unit of the FBI Laboratory since the more traditional techniques of latent finger print analysis and document analysis are well known.

Donnelly, Brian↗

Field dependence of gaseous ion mobility: Test of approximate formulas

The accuracies of three approximate formulas were tested by comparison with special cases for which accurate results could be found. The Wannier free flight theory was found to be superior, and can be extended to yield a formula without further adjustable constants that gives an exact result at low electric fields and good results at medium and high fields. It is applicable for any ion neutral force law and mass ratio.

Hahn, H.↗

Field dependence of gaseous-ion mobility - Theoretical tests of approximate formulas.

The approximate formulas considered include relations based on the Wannier free-flight theory, the Kihara medium-field expansion, and the Frost-Patterson interpolation formulas. A few accurate theoretical results are available for testing the foregoing formulas. Cases concerning high fields, intermediate fields, and resonant charge transfer are examined. It is found that of the formulas tested, the one based on the Wannier free-flight theory is the most flexible, since it can be used for all fields and all ion-neutral force laws and mass ratios.

Hahn, H.↗

The effect of sample holder material on ion mobility spectrometry reproducibility

When a positive detection of a narcotic occurs during the search of a vessel, a decision has to be made whether further intensive search is warranted. This decision is based in part on the results of a second sample collected from the same area. Therefore, the reproducibility of both sampling and instrumental analysis is critical in terms of justifying an in depth search. As reported at the 2nd Annual IMS Conference in Quebec City, the U.S. Coast Guard has determined that when paper is utilized as the sample desorption medium for the Barringer IONSCAN, the analytical results using standard reference samples are reproducible. A study was conducted utilizing papers of varying pore sizes and comparing their performance as a desorption material relative to the standard Barringer 50 micron Teflon. Nominal pore sizes ranged from 30 microns down to 2 microns. Results indicate that there is some peak instability in the first two to three windows during the analysis. The severity of the instability was observed to increase as the pore size of the paper is decreased. However, the observed peak instability does not create a situation that results in a decreased reliability or reproducibility in the analytical result.

Jadamec, J. Richard↗

Classification of Ion Mobility Data Using the Neural Network Approach

Determination of atmospheric and surface elemental and molecular composition of various solar system bodies is essential to the development of a firm understanding of the origin and evolution of the solar system. Furthermore, such data is needed to address the intriguing question of whether or not life exists or once existed elsewhere in the Solar System. As such, these measurements are among the primary scientific goals of NASA s current and future planetary missions. In recent years, significant progress toward both miniaturization and field portability of in situ analytical separation and detection devices have been made with future planetary explorations in mind. However, despite all these advances, accurate in situ identification of atmospheric and surface compounds remains a big challenge. In response to that we are developing various hardware and software tools which would enable us to uniquely identify species of interest in a complex chemical environment.

Duong, T. A.↗

Mobilities of polyatomic ions in gases - Core model.

A core model, consisting of a (12-4) central potential displaced from the origin, is suggested as a representation of the interaction of polyatomic ions with neutral molecules. The diffusion collision integral, which describes ion mobility, is computed and tabulated as a function of temperature and core size. The addition of the core reduces the maximum in the mobility against temperature curve, and eventually reduces the mobility below its polarization limit at all temperatures. These results are in accord with limited available experimental data. Comparison is made with other models of ion-neutral interactions.

Mason, E. A.↗

Electrical properties of the middle atmosphere

Probe techniques have been utilized extensively to measure middle atmospheric electrical properties such as the polar components of conductivity, ion mobility and density. The most variable of these parameters is conductivity, which is dependent on both charge mobility and concentration. Overall conductivity variations, attributable to different geophysical conditions, can exceed several orders of magnitude at some altitudes. Also, measurements of conductivity over the 20 to 90 km region indicate a general exponential increase with altitude, exceeding seven orders of magnitude during certain conditions. Gerdien condensers, on occasion, have measured very low-mobility positive ions in addition to the more commonly observed molecular species. These smaller mobility values appear to indicate the presence of very large ions at some altitudes, possibly charged particulates, having mass sizes greater than those identifiable by presently flown mass spectrometers. The presence of these large ions is of importance to middle atmospheric electrodynamics as a potential causal mechanism for measured large electric fields.

Mitchell, John D.↗

Middle-atmosphere positive ion measurements during solar eclipses

Solar effects on middle-atmosphere electrical parameters, as demonstrated by eclipse-associated responses of conductivity, ion mobility, and charge density, are considered for the total solar eclipses at Red Lake, Ontario, Canada on February 26, 1979 and at San Marco range, Kenya, on February 16, 1980. Negative-conductivity measurements for the Canadian eclipse and probe-current measurements for the Kenyan eclipse demonstrate a rapid loss of free electrons below 80 km at totality. During the Kenyan eclipse, positive-ion responses were different for each of two distinct ion mobility groups. Between 45 and 60 km, eclipse-related positive-ion responses are associated with the low-mobility ions. It is shown that these ions are lost at totality and that an excess buildup occurs following totality. Above 70 km, positive-ion loss at totality is associated with the more mobile ions and only low-mobility positive ions are measured in this region. The buildup in total ion density following totality is thought to result from a reduction in ion loss associated with weak-electron recovery in the region.

Mitchell, J. D.↗

Application of Ni-63 photo and corona discharge ionization for the analysis of chemical warfare agents and toxic wastes

Over the past decade, advances in instrumental design and refinements in the understanding of ion molecule reactions at atmospheric pressure enabled the application of Ion Mobility Spectrometry (IMS) as a simple inexpensive and sensitive analytical method for the detection of organic trace compounds. Positive and negative gas-phase ions for ion mobility spectrometry have been produced by a variety of methods, including photo-ionization, laser multi photon ionization, surface ionization, corona discharge ionization. The most common ion source used in ion mobility spectrometry is a radioactive Ni-63 foil which is favored due to simplicity, stability, convenience, and high selectivity. If reactant ions like (H2O(n)H)(+) or (H2O(n)O2)(-) dominate in the reaction region, nearly all kinds of compounds with a given proton or electron affinity; are ionized. However, the radioactivity of the Ni-63 foil is one disadvantage of this ion source that stimulates the development and application of other ionization techniques. In this paper, we report analyses of old chemical warfare agents and toxic wastes using Bruker RAID ion mobility spectrometers. Due to the modular construction of the measuring cell, the spectrometers can be equipped with different ion sources. The combined use of Ni-63, photo- and corona discharge ionization allows the identification of different classes of chemical compounds and yields in most cases comparable results.

Stach, J.↗

The pinhole interface for IMS/MS

An important supplementary technique for ion mobility spectrometry (IMS) is mass spectrometry (MS). A mass spectrometer coupled to an ion mobility spectrometer (IMS/MS) can provide significant information on the composition of the ions contributing to an ion mobility peak. On the other hand, the interpretation of IMS/MS results requires knowledge of processes which can occur at the pinhole interface. When the ion composition is a mixture of ion clusters, the observed cluster distribution may not be an accurate representation of the ion clusters in the IMS. Depending on the buffer gas, lower clusters can form by equilibrating with reduced concentrations in the continuum regime of the expansion and larger clusters can form by collisional stabilization in the cooled jet stream. Besides water, nitrogen molecules can also add to the ion clusters. Even though nitrogen is non-polar, this addition is made possible by an ion-induced dipole interaction between the ion and molecule.

Spangler, Glenn E.↗

Electrospray Ionization/Ion Mobility Spectrometer/Cylindrical Ion Trap Mass Spectrometer System for In-Situ Detection of Organic Compounds

The potential of an Electrospray Ionization/Ion Mobility Spectrometer/Cylindrical Ion Trap Mass Spectrometer (ESI/IMS/CIT-MS) as an analytical instrument for analyzing material extracted from rock and soil samples as part of a suite of instruments on the proposed 2009 Mars Science Lander (MSL) will be demonstrated. This instrument will be able to identify volatile compounds as well as resident organic molecules on the parts-per-billion (ppb) level. Also, it will be able to obtain an inventory of chemical species on the surface of Mars which will result in a better understanding of ongoing surface chemistry. Finally, questions relevant to biological processes will be answered with the complete inventory of surface and near surface organic molecules that the ESI/IMS/CIT is capable of performing.

Kanik, I.↗