Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion beam analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Dephasing of ion beams as magnetic vortex acceleration regime transitions into a bubble-like field structure

The interaction of an ultra-intense laser pulse with a near critical density target results in the formation of a plasma channel, a strong azimuthal magnetic field and moving vortices. An application of this is the generation of energetic and collimated ion beams via magnetic vortex acceleration. The optimized regime of magnetic vortex acceleration is becoming experimentally accessible with new high intensity laser beamlines coming online and advances made in near critical density target fabrication. The robustness of the acceleration mechanism with realistic experimental conditions is examined with three-dimensional simulations. Of particular interest is the acceleration performance with different laser temporal contrast conditions, in some cases leading to pre-expanded target profiles prior to the arrival of the main pulse. Preplasma effects on the structure of the accelerating fields are explored, including a detailed analysis of the ion beam properties and the efficiency of the process. Improved scaling laws for the magnetic vortex acceleration mechanism, including the laser focal spot size effects, are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-scale structural analysis of swift heavy ion-irradiated ZrO 2 and HfO 2

The radiation-induced monoclinic-to-tetragonal phase transition in ZrO 2 and HfO 2 has been the subject of many investigations, but the transformation pathways and underlying structural mechanisms are still not well understood. In this study, microcrystalline powder samples of ZrO 2 and HfO 2 were irradiated with 946 MeV and 1470 MeV Au ions to a wide fluence range up to 3 × 10 13 ions/cm 2 . To characterize beam-induced structural modifications across all spatial length scales, complementary experimental techniques such as synchrotron X-ray diffraction and spallation neutron total scattering were used. The phase evolution of the tetragonal polymorph with increasing ion fluence is accurately described by a heterogeneous track-overlap model that incorporates both direct- and double-impact processes. These damage accumulation processes are an expression of a core-shell ion track morphology that depends on irradiation conditions and target material. Neutron pair distribution function analysis revealed that ion-beam-induced tetragonal ZrO 2 is merely a configurational average of short-range orthorhombic (Pbcn) domains stabilized by a dense network of domain walls. Furthermore, this knowledge is critical for a better understanding of how crystalline-to-crystalline phase transformations proceed at the atomic scale under extreme conditions.

Monoclinic-to-tetragonal phase transformation↗

Conjugate Multimode Heat Transfer Analysis of Cryogenic EXLO Manipulation

Abstract In this study, a conjugate radiation/conduction multimode heat transfer analysis of cryogenic focused ion beam (FIB) milling steps necessary for producing ex situ lift out specimens under cryogenic conditions (cryo-EXLO) is performed. Using finite volume for transient heat conduction and enclosure theory for radiation heat transfer, the analysis shows that as long as the specimen is attached or touching the FIB side wall trenches, the specimen will remain vitreous indefinitely, while actively cooled at liquid nitrogen (LN2) temperatures. To simulate the time needed to perform a transfer step to move the bulk sample containing the FIB-thinned specimen from the cryo-FIB to the cryo-EXLO cryostat, the LN2 temperature active cooling is turned off after steady-state conditions are reached and the specimen is monitored over time until the critical devitrification temperature is reached. Under these conditions, the sample will remain vitreous for >3 min, which is more than enough time needed to perform the cryo-transfer step from the FIB to the cryostat, which takes only ∼10 s. Cryo-transmission electron microscopy images of a manipulated cryo-EXLO yeast specimen prepared with cryo-FIB corroborates the heat transfer analysis.

Materials Science↗

Reactive Carbide‐Based Synthesis and Microstructure of NASICON Sodium Metal All Solid‐State Electrolyte

Reactive carbide precursor-based synthesis of NASICON-type NZSP (Na 1+x Zr 2 Si x P 3-x O 12 ) solid-state electrolyte (SSE) is demonstrated, in contrast to the established oxide-based approach. Exothermic decomposition of ZrC and SiC in air homogenizes microstructure, yielding 98% compact density after conventional sintering at 1200 °C. Quantitative stereology demonstrates that significant microstructural differences are present. Compacts of carbide-derived Carb-NZSP are 98% dense with a secondary zirconium oxide (ZrO 2 ) volume fraction of 0.2% ± 0.3%, versus 93% dense and 3% ± 1% for oxide-derived baseline. For Carb-NZSP, the secondary glassy phosphate phase is agglomerated, while for baseline, it is dispersed and percolated. Electrochemical testing combined with post-mortem analysis demonstrates how microstructural control of secondary phases is critical for dendrite suppression: Carb-NZSP critical current density (CCD) is 3.1 ± 0.8 mA cm −2 at 0.1 mAh cm −2 , versus 1.0 ± 0.7 mA cm −2 at 0.1 mAh cm −2 . Cryogenic focused ion beam (cryo-FIB) analysis demonstrates that in both materials, the porous 2D sheet-like sodium metal dendrites propagate around and subsume NZSP grains, likely following a path enriched with glassy phase and with porosity. Dendrites also flow around isolated zirconia particles. Phase field simulation reveals deflection of dendrites by mechanically tough zirconia, while brittle glassy phase accelerates dendrite growth, especially when finely distributed.

36 MATERIALS SCIENCE↗

Beam characterization at NSRL for radiobiological experiments—phase 1

An experimental campaign was carried out at the NASA Space Radiation Laboratory to perform an additional, independent dosimetric characterization of the beams of protons, helium and carbon ions for radiobiological experiments. The campaign was undertaken by the request and with the support from the National Cancer Institute, U.S. In this initial phase, the goals were to obtain a first assessment of the dosimetric reproducibility of the beam control system, including analysis of spatial homogeneity and evaluation of ion beam contamination. They should facilitate the design of further experimental campaigns for beam characterization for radiobiological experiments. Measurements included reference dosimetry with comparison of in-house and external ionization chambers and electrometers, lateral-dose profile measurements in air, depth-dose profile in a water tank, evaluation of water equivalent thickness of a HDPE binary range shifter and estimation of impurities of the investigated helium-ion beam. The experiments and results are presented.

43 PARTICLE ACCELERATORS↗

Alumina – Stabilized SEI and CEI in Potassium Metal Batteries

Aluminum oxide (Al 2 O 3 ) nanopowder is spin-coated onto both sides of commercial polypropene separator to create artificial solid-electrolyte interphase (SEI) and artificial cathode electrolyte interface (CEI) in potassium metal batteries (KMBs). Here, this significantly enhances the stability, including of KMBs with Prussian Blue (PB) cathodes. For example, symmetric cells are stable after 1,000 cycles at 0.5 mA/cm 2 –0.5 mAh/cm 2 and 3.0 mA/cm 2 –0.5 mAh/cm 2 . Alumina modified separators promote electrolyte wetting and increase ionic conductivity (0.59 vs. 0.2 mS/cm) and transference number (0.81 vs. 0.23). Cryo-stage focused ion beam (cryo-FIB) analysis of cycled modified anode demonstrates dense and planar electrodeposits, versus unmodified baseline consisting of metal filaments (dendrites) interspersed with pores and SEI. Alumina-modified CEI also suppresses elemental Fe crossover and reduces cathode cracking. Mesoscale modeling of metal – SEI interactions captures crucial role of intrinsic heterogeneities, illustrating how artificial SEI affects reaction current distribution, conductivity and morphological stability.

25 ENERGY STORAGE↗

Controlling superconductivity of CeIrIn 5 microstructures by substrate selection

Superconductor/metal interfaces are usually fabricated in heterostructures that join these dissimilar materials. A conceptually different approach has recently exploited the strain sensitivity of heavy-fermion superconductors, selectively transforming regions of the crystal into the metallic state by strain gradients. The strain is generated by differential thermal contraction between the sample and the substrate. Here, we present an improved finite-element model that reliably predicts the superconducting transition temperature in CeIrIn 5 even in complex structures. Different substrates are employed to tailor the strain field into the desired shapes. Using this approach, both highly complex and strained as well as strain-free microstructures are fabricated to validate the model. This enables a high degree of control over the microscopic strain fields and forms the basis for more advanced structuring of superconductors as in Josephson junctions yet also finds natural use cases in any material class in which a modulation of the physical properties on a chip is desirable.

36 MATERIALS SCIENCE↗

Control of wetting and uniformity via ZrSi x formation in ceramic-to-metal joints fabricated using Ag-Zr brazes

The deposition of a 2.0 µm SiO 2 film on the alumina surface in Kovar TM /94% alumina joints enables the formation of a silicide reaction layer on the alumina during brazing with 97Ag2Zr1Cu. Additionally, the average and standard deviation of joint thickness decrease from 50 to 15 and 29 to 4 µm, respectively compared to joints without added SiO 2 . Finally, the average failure stress of these braze joints was 45 MPa, while that of similar joints without added SiO 2 was 90 MPa. Sessile drop experiments of 98Ag2Zr on SiO 2 and 99.6% Al 2 O 3 substrates show that the braze wets and spreads to 3x its original area on SiO 2 with a wetting angle near 0°, but remains the same area on 99.6% Al 2 O 3 with a wetting angle of 106.6°. Focused-ion-beam scanning electron microscopy analysis of a cross-section of the 98Ag2Zr sessile drop on the SiO 2 substrate has shown that Zr reacts with SiO 2 to form Zr oxide and silicide layers. Scanning transmission electron microscopy diffraction and energy dispersive X-ray spectroscopy analysis indicate this silicide layer contains tetragonal Zr 5 Si 4 . In conclusion, analysis shows the silicide layer enhances wetting and joint uniformity while unreacted SiO 2 embrittles the joint and degrades strength.

alumina↗

Capturing Carbonation: Understanding Kinetic Complexities through a New Era of Electron Microscopy

Cryogenic plasma focused ion beam (PFIB) electron microscopy analysis is applied to visualizing ex situ (surface industrial) and in situ (subsurface geologic) carbonation products, to advance understanding of carbonation kinetics. Ex situ carbonation is investigated using NIST fly ash standard #2689 exposed to aqueous sodium bicarbonate solutions for brief periods of time. In situ carbonation pathways are investigated using volcanic flood basalt samples from Schaef et al. (2010) exposed to aqueous CO 2 solutions by them. The fly ash reaction products at room temperature show small amounts of incipient carbonation, with calcite apparently forming via surface nucleation. Reaction products at 75° C show beginning stages of an iron carbonate phase, e.g., siderite or ankerite, common phases in subsurface carbon sequestration environments. This may suggest an alternative to calcite in carbonation low calcium-bearing fly ashes. Flood basalt carbonation reactions show distinct zonation with high calcium and calcium-magnesium bearing zones alternating with high iron-bearing zones. The calcium-magnesium zones are notable with occurrence of localized pore space. Oscillatory zoning in carbonate minerals is distinctly associated with far-from-equilibrium conditions where local chemical environments fluctuate via a coupling of reaction with transport. The high porosity zones may reflect a precursor phase (e.g., aragonite) with higher molar volume that then “ripens” to the high-Mg calcite phase-plus-porosity. These observations reveal that carbonation can proceed with evolving local chemical environments, formation and disappearance of metastable phases, and evolving reactive surface areas. Together this work shows that future application of cryo-PFIB in carbonation studies would provide advanced understanding of kinetic mechanisms for optimizing industrial-scale and commercial-scale applications.

36 MATERIALS SCIENCE↗

Higher Order Multipole Analysis of Beam Crabbing Mode at 197 MHz for Electron-Ion Collider

In the local crabbing scheme for Electron Ion Collider interaction region, beam rotation is initiated by one set of crab cavities at a high beta region with near 90 deg phase advance to the interaction point (IP), and ceased by an identical set of cavities on the symmetrically opposite side. The fundamental mode of all crab cavities is designed to apply a momentum kick to the particle bunches to complete this half cycle of rotation in the horizontal plane, meanwhile the electromagnetic (EM) field can be expanded into a series of harmonics. Despite the lowest dipole mode, higher harmonics cause instabilities during beam operation and loss of particles. We used SimTrack, which is the 6-d symplectic element-by-element tracking code developed at Brookhaven National Laboratory in 2015, to study the threshold of each higher-order harmonic multipolar mode with the criteria of maintaining a dynamic aperture of 6 σ or greater for the Hadron Storage Ring (HSR). In this paper, we showed the threshold for each higher harmonic multipole and their comparison with the multipole strength for the current crab cavity design.

43 PARTICLE ACCELERATORS↗

A reliable workflow for improving nanoscale X-ray fluorescence tomographic analysis on nanoparticle-treated HeLa cells

Abstract Scanning X-ray fluorescence (XRF) tomography provides powerful characterization capabilities in evaluating elemental distribution and differentiating their inter- and intra-cellular interactions in a three-dimensional (3D) space. Scanning XRF tomography encounters practical challenges from the sample itself, where the range of rotation angles is limited by geometric constraints, involving sample substrates or nearby features either blocking or converging into the field of view. This study aims to develop a reliable and efficient workflow that can (1) expand the experimental window for nanoscale tomographic analysis of local areas of interest within a laterally extended specimen, and (2) bridge 3D analysis at micrometer and nanoscales on the same specimen. We demonstrate the workflow using a specimen of HeLa cells exposed to iron oxide core and titanium dioxide shell (Fe3O4/TiO2) nanocomposites. The workflow utilizes iterative and multiscale XRF data collection with intermediate sample processing by focused ion beam (FIB) sample preparation between measurements at different length scales. Initial assessment combined with precise sample manipulation via FIB allows direct removal of sample regions that are obstacles to both incident X-ray beam and outgoing XRF signals, which considerably improves the subsequent nanoscale tomography analysis. This multiscale analysis workflow has advanced bio-nanotechnology studies by providing deep insights into the interaction between nanocomposites and single cells at a subcellular level as well as statistical assessments from measuring a population of cells.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Title Coherent X-ray Studies of Surface Growth and Patterning Processes

X-ray Photon Correlation Spectroscopy (XPCS) is being developed as a tool to study nanoscale dynamics of fluctuations during thin film growth and surface patterning. XPCS examines the evolution of the X-ray scattering speckle pattern in reciprocal space to reveal dynamics information not accessible through any other means. Unlike low-coherence conventional X-ray scattering, which incoherently averages over different regions of a sample, coherent X-ray scattering is sensitive to the detailed structure of a given sample at that moment in time. In thin film growth processes, heterodyning, which occurs due to coherent mixing of two scattered signals, can be used to investigate the relationship between surface growth velocity and defect propagation. And, for polycrystalline thin film growth, the spatial coherence of the X-ray beam can substitute for the missing spatial coherence of the growth process to track layered growth in detail, even in a growth regime in which there are no conventional growth oscillations of the X-ray intensity. This has opened the door for detailed dynamics studies of individual atomic layers during real-world growth and patterning, not just in perfect single-crystal growth cases, which greatly expands the applicability of in-situ X-ray scattering methods. Step-flow dynamics in mounded polycrystalline growth has been studied separately for two thin film organic semiconductors deposited by thermal deposition in a vacuum environment, C60 and diindenoperylene (DIP). Highly oriented polycrystalline thin films are readily obtained in both systems, where mounds are composed of crystalline monolayer-height steps and terraces in a so-called wedding cake morphology. The formation of mounds is understood to be due to significant Ehrlich-Schwoebel step edge barriers that inhibit molecules from hopping down from one layer to the one below. The mounds exhibit local step flow, which can be monitored using coherent X-ray scattering. This is made possible due to heterodyning between scattering from the average mounds and the moving steps, which becomes visible in XPCS analysis. The effect of desorption, i.e. re-evaporation of deposited molecules is found to be important for understanding these processes. The impact of this work is to enable testing of models of step dynamics, the shape of mounds, and merging of mounds to form continuous thin films. Highly ordered polycrystalline thin films deposited on inexpensive substrates have applications in thin film solar cells and other organic electronic devices. In a separate set of experiments, speckle analysis during self-organized ion beam nanopatterning reveals memory stretching back to the beginning of patterning in the early stages and enables measurement of the velocity of self-organized patterns across surfaces providing the possibility of stringent new tests of the theory of pattern formation and motion.

36 MATERIALS SCIENCE↗

Multi-Scale Characterization of Porosity and Cracks in Silicon Carbide Cladding after Transient Reactor Test Facility Irradiation

Silicon carbide (SiC) ceramic matrix composite (CMC) cladding is currently being pursued as one of the leading candidates for accident-tolerant fuel (ATF) cladding for light water reactor applications. The morphology of fabrication defects, including the size and shape of voids, is one of the key challenges that impacts cladding performance and guarantees reactor safety. Therefore, quantification of defects’ size, location, distribution, and leak paths is critical to determining SiC CMC in-core performance. This research aims to provide quantitative insight into the defect’s distribution under multi-scale characterization at different length scales before and after different Transient Reactor Test Facility (TREAT) irradiation tests. A non-destructive multi-scale evaluation of irradiated SiC will help to assess critical microstructural defects from production and/or experimental testing to better understand and predict overall cladding performance. X-ray computed tomography (XCT), a non-destructive, data-rich characterization technique, is combined with lower length scale electronic microscopic characterization, which provides microscale morphology and structural characterization. This paper discusses a fully automatic workflow to detect and analyze SiC-SiC defects using image processing techniques on 3D X-ray images. Following the XCT data analysis, advanced characterizations from focused ion beam (FIB) and transmission electron microscopy (TEM) were conducted to verify the findings from the XCT data, especially quantitative results from local nano-scale TEM 3D tomography data, which were utilized to complement the 3D XCT results. In this work, three SiC samples (two irradiated and one unirradiated) provided by General Atomics are investigated. The irradiated samples were irradiated in a way that was expected to induce cracking, and indeed, the automated workflow developed in this work was able to successfully identify and characterize the defects formation in the irradiated samples while detecting no observed cracking in the unirradiated sample. These results demonstrate the value of automated XCT tools to better understand the damage and damage propagation in SiC-SiC structures for nuclear applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Grain boundary zirconia-modified garnet solid-state electrolyte

Here, we report a method for promoting electrochemical stability in garnet Li 6.4 La 3 Zr 1.4 Ta 0.6 O 12 solid-state electrolyte based on a composite two-phase oxide–oxide microstructure. Grain boundary precipitation of the controlled distribution of amorphous zirconium oxide microparticles is achieved through the addition of reactive tantalum carbide. During ambient-atmosphere sintering, the carbide decomposes through an in situ reaction, the ‘extra’ Ta substituting for Zr within the Li 6.4 La 3 Zr 1.4 Ta 0.6 O 12 lattice. Density functional theory (DFT) calculations identify a thermodynamically favourable reaction path and show how substituting Ta 5+ at Zr 4+ sites affects the crystal structure as well as bulk ionic and electronic conductivities. Quantitative stereology highlights that zirconia also acts as a sintering aid, reducing compact porosity. Cryogenic focused-ion-beam scanning electron microscopy and fractography analysis of cycled solid-state electrolytes illustrates that near-universally observed intergranular Li-metal dendrite propagation is suppressed by the two-phase microstructure, favouring transgranular dendrites instead. Importantly, DFT demonstrates that compared with the Li 6.4 La 3 Zr 1.4 Ta 0.6 O 12 surface, the zirconium oxide surface per se is less electronically conductive and does not trap excess electrons to reduce Li ions. This is a key reason for the substantial improvement in the electrochemical properties over the single-phase baseline.

36 MATERIALS SCIENCE↗

Ytterbium Ion Collection on Graphite Plates

Surface characterization and analysis of the graphite collection and strike plates was conducted in this report. These plates were from an electromagnetic isotope separation collector that had been irradiated with an ytterbium ion beam. The results of this study are reported along with analysis and discussion of the potential growth mechanism of the ytterbium layer on graphite. It is proposed that directional deposition of ytterbium ions occurs first in the defect regions of the graphite plate. As deposition continues, it leads to the eventual formation of directional globs that elongate and grow into plates, then stacks, and finally into sheets of ytterbium. The ytterbium layer appears to have a definite phase boundary with the graphite layer. It was also determined that during irradiation with the ytterbium ion beam, the sputtered carbon becomes interpolated in the ytterbium surface layer on the graphite plate and has an amorphous microstructure.

36 MATERIALS SCIENCE↗

The Single Event Error (SEE) test and analysis of the CMS Endcap Timing Layer readout chip

The ETROC2, the first full size and full functionality prototype chip for the CMS Endcap Timing Layer readout, is strategically designed to meet the SEE immunity requirements of detector operation with the low power constraint. The triplicated periphery and pixel I2C configuration registers are designed with self-correction feature. The pixel readout control is centralized in the global readout and fully triplicated. The pixel readout is not triplicated, instead protected with power-efficient one-bit correction Hamming code. The TMR protection of the on-pixel threshold calibration can be turned off allowing the detection of the beam spot during the beam test by checking the bit-flips of the internal memory cells. In the initial proton beam test in January 2024, the chip readout process did not hang throughout the tests. The Hamming code correction strategy works because the error corrected TDC data were observed in the data frames. The error-injection simulation is performed to analy ze the small number of bit-flips in the configuration registers. We also performed SEE testing with a heavy ion beam in April and the data analysis is ongoing. The detailed design on the SEE immunity and the testing as well as simulation results will be presented, including follow-up SEE testing results in May and June 2024.

Gong, Datao↗

Machine Learning for Predictive Performance Analysis in Charged Particle Beam Tools

Imaging methods driven by probes, electrons, and ions have played a dominant role in modern science and engineering. Opportunities for machine vision and AI that focus on consumer problems like driving and feature recognition, are now presenting themselves for automating aspects of the scientific processes. This proposal aims to enable and drive discovery in ultra-low energy implantation by taking advantage of faster processing, flexible control and detection methods, and architecture-agnostic workflows that will result in higher efficiency and shorter scientific development cycles. Custom microscope control, collection and analysis hardware will provide a framework for conducting novel in situ experiments revealing unprecedented insight into surface dynamics at the nanoscale. Ion implantation is a key capability for the semiconductor industry. As devices shrink, novel materials enter the manufacturing line, and quantum technologies transition to being more mainstream. Traditional implantation methods fall short in terms of energy, ion species, and positional precision. Here we demonstrate 1 keV focused ion beam Au implantation into Si and validate the results via atom probe tomography. We show the Au implant depth at 1 keV is 0.8 nm and that identical results for low energy ion implants can be achieved by either lowering the column voltage, or decelerating ions using bias – while maintaining a sub-micron beam focus. We compare our experimental results to static calculations using SRIM and dynamic calculations using binary collision approximation codes TRIDYN and IMSIL. A large discrepancy between the static and dynamic simulation is found that is due to lattice enrichment with high stopping power Au and surface sputtering. Additionally, we demonstrate how model details are particularly important to the simulation of these low-energy heavy-ion implantations. Finally, we discuss how our results pave a way to much lower implantation energies, while maintaining high spatial resolution.

47 OTHER INSTRUMENTATION↗