Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “intervals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Pathologic Response, When Increased by Longer Interval, Is a Marker but Not the Cause of Good Prognosis in Rectal Cancer: 17-year Follow-up of the Lyon R90-01 Randomized Trial

Purpose: The Lyon R90-01 randomized trial investigated whether the interval between preoperative radiation therapy and surgery influenced rectal cancer outcome. Long-term results are reported here after a median follow-up of 17 years. Methods and Materials: Between February 1991 and December 1995, 210 patients from 29 French centers were randomly assigned (ratio of 1:1) to groups that waited either 2 weeks (short interval [SI]) or 6 to 8 weeks (long interval [LI]) between neoadjuvant radiation therapy and surgery. The primary endpoint was sphincter-preserving surgery. Results: LI group showed a better pathologic response (complete response or few residual cells) after radiation therapy than the SI group (26% vs 10.3%, P=.015). A better pathologic response was associated in multivariate analysis with significant improvement of overall survival (pT: P=.0293 and pN: P=.0048) but it was irrespective of the interval duration. The median follow-up was 17.2 years. The 5-, 10-, 15-, and 17-year overall survival rates were, respectively, 66.8%, 48.7%, 40.0%, and 34.0% for the SI group and, respectively, 67.1%, 53.5%, 41.9%, and 34.0% for the LI group. There were no significant differences between groups in terms of survival (P=.7656) or local recurrence rates (SI: 14.4% vs LI: 12.1%, respectively; P=.6202). Of 24 local disease recurrences, 20 (83%) occurred during the first 2 postoperative years, and all but one (96%) occurred during the first 5 postoperative years. The rate of second new malignancies was 9.4% (19 patients). Conclusions: The radiation-induced sterilization rate of the preoperative cancer specimen was a marker of good prognosis. The interval duration (the treatment being the same) although it is modifying the sterilization rate has no impact on survival. Radiation therapy did not postpone local recurrence, because the rate of local relapse after 5 years was low. Radiation-induced cancers after radiation therapy were unusual and should not influence treatment decisions in adults.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An interval-parameter stochastic robust optimization model for supporting municipal solid waste management under uncertainty

A stochastic robust interval linear programming model (IPRO) was developed for supporting municipal solid waste management under uncertainty. The model improves upon the existing stochastic robust optimization (SRO) and interval linear programming (ILP) methods by allowing evaluations of trade-offs among expected costs, cost variability, and risk of violating relax constraints simultaneously, as well as reflections of complex uncertainties through both interval and stochastic theories. A long-term waste management problem was used to demonstrate the applicability of IPRO model. The results indicated that IPRO normally led to interval solutions, where waste-management alternatives could be generated by adjusting the decision-variable values within their intervals. The model could also help waste managers to identify desired policies that under various environmental, economic, system-feasibility and system-reliability constraints.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Oscillatory dynamics of an intravenous glucose tolerance test model with delay interval

We report that type 2 diabetes mellitus (T2DM) has become prevalent pandemic disease in view of the modern life style. Both diabetic population and health expenses grow rapidly according to American Diabetes Association. Detecting the potential onset of T2DM is an essential focal point in the research of diabetes mellitus. The intravenous glucose tolerance test (IVGTT) is an effective protocol to determine the insulin sensitivity, glucose effectiveness, and pancreatic β-cell functionality, through the analysis and parameter estimation of a proper differential equation model. Delay differential equations have been used to study the complex physiological phenomena including the glucose and insulin regulations. In this paper, we propose a novel approach to model the time delay in IVGTT modeling. This novel approach uses two parameters to simulate not only both discrete time delay and distributed time delay in the past interval, but also the time delay distributed in a past sub-interval. Normally, larger time delay, either a discrete or a distributed delay, will destabilize the system. However, we find that time delay over a sub-interval might not. We present analytically some basic model properties, which are desirable biologically and mathematically. We show that this relatively simple model provides good fit to fluctuating patient data sets and reveals some intriguing dynamics. Moreover, our numerical simulation results indicate that our model may remove the defect in well known Minimal Model, which often overestimates the glucose effectiveness index. Delay differential equations (DDEs) have been frequently used to study complex dynamics observed in nature. More recently, they are used to understand intriguing physiological phenomena such as those expressed by glucose and insulin interaction. We propose a simple set of delay differential equations to model an intravenous glucose tolerance test. This model uses two parameters to simulate not only both discrete time delay and distributed time delay in the past interval, but also the time delay distributed in a past sub-interval. We show that this relatively simple model provides good fit to fluctuating patient data sets and reveals some intriguing dynamics. Lastly and most importantly, our model may remove the defect in the well known Minimal Model (MM) which often overestimates the glucose effectiveness (GE) index.

59 BASIC BIOLOGICAL SCIENCES↗

High resolution time interval counter

In recent years, we have developed two types of high resolution, multi-channel time interval counters. In the NIST two-way time transfer MODEM application, the counter is designed for operating primarily in the interrupt-driven mode, with 3 start channels and 3 stop channels. The intended start and stop signals are 1 PPS, although other frequencies can also be applied to start and stop the count. The time interval counters used in the NIST Frequency Measurement and Analysis System are implemented with 7 start channels and 7 stop channels. Four of the 7 start channels are devoted to the frequencies of 1 MHz, 5 MHz or 10 MHz, while triggering signals to all other start and stop channels can range from 1 PPS to 100 kHz. Time interval interpolation plays a key role in achieving the high resolution time interval measurements for both counters. With a 10 MHz time base, both counters demonstrate a single-shot resolution of better than 40 ps, and a stability of better than 5 x 10(exp -12) (sigma(sub chi)(tau)) after self test of 1000 seconds). The maximum rate of time interval measurements (with no dead time) is 1.0 kHz for the counter used in the MODEM application and is 2.0 kHz for the counter used in the Frequency Measurement and Analysis System. The counters are implemented as plug-in units for an AT-compatible personal computer. This configuration provides an efficient way of using a computer not only to control and operate the counters, but also to store and process measured data.

Zhang, Victor S.↗

Age-related alterations in the fractal scaling of cardiac interbeat interval dynamics

We postulated that aging is associated with disruption in the fractallike long-range correlations that characterize healthy sinus rhythm cardiac interval dynamics. Ten young (21-34 yr) and 10 elderly (68-81 yr) rigorously screened healthy subjects underwent 120 min of continuous supine resting electrocardiographic recording. We analyzed the interbeat interval time series using standard time and frequency domain statistics and using a fractal measure, detrended fluctuation analysis, to quantify long-range correlation properties. In healthy young subjects, interbeat intervals demonstrated fractal scaling, with scaling exponents (alpha) from the fluctuation analysis close to a value of 1.0. In the group of healthy elderly subjects, the interbeat interval time series had two scaling regions. Over the short range, interbeat interval fluctuations resembled a random walk process (Brownian noise, alpha = 1.5), whereas over the longer range they resembled white noise (alpha = 0.5). Short (alpha s)- and long-range (alpha 1) scaling exponents were significantly different in the elderly subjects compared with young (alpha s = 1.12 +/- 0.19 vs. 0.90 +/- 0.14, respectively, P = 0.009; alpha 1 = 0.75 +/- 0.17 vs. 0.99 +/- 0.10, respectively, P = 0.002). The crossover behavior from one scaling region to another could be modeled as a first-order autoregressive process, which closely fit the data from four elderly subjects. This implies that a single characteristic time scale may be dominating heartbeat control in these subjects. The age-related loss of fractal organization in heartbeat dynamics may reflect the degradation of integrated physiological regulatory systems and may impair an individual's ability to adapt to stress.

NASA Discipline Cardiopulmonary↗

High Resolution ECG for Evaluation of QT Interval Variability during Exposure to Acute Hypoxia

Ventricular repolarization instability as quantified by the index of QT interval variability (QTVI) is one of the best predictors for risk of malignant ventricular arrhythmias and sudden cardiac death. Because it is difficult to appropriately monitor early signs of organ dysfunction at high altitude, we investigated whether high resolution advanced ECG (HR-ECG) analysis might be helpful as a non-invasive and easy-to-use tool for evaluating the risk of cardiac arrhythmias during exposure to acute hypoxia. 19 non-acclimatized healthy trained alpinists (age 37, 8 plus or minus 4,7 years) participated in the study. Five-minute high-resolution 12-lead electrocardiograms (ECGs) were recorded (Cardiosoft) in each subject at rest in the supine position breathing room air and then after breathing 12.5% oxygen for 30 min. For beat-to-beat RR and QT variability, the program of Starc was utilized to derive standard time domain measures such as root mean square of the successive interval difference (rMSSD) of RRV and QTV, the corrected QT interval (QTc) and the QTVI in lead II. Changes were evaluated with paired-samples t-test with p-values less than 0.05 considered statistically significant. As expected, the RR interval and its variability both decreased with increasing altitude, with p = 0.000 and p = 0.005, respectively. Significant increases were found in both the rMSSDQT and the QTVI in lead II, with p = 0.002 and p = 0.003, respectively. There was no change in QTc interval length (p = non significant). QT variability parameters may be useful for evaluating changes in ventricular repolarization caused by hypoxia. These changes might be driven by increases in sympathetic nervous system activity at ventricular level.

Zupet, P.↗

Comparison of Controller and Flight Deck Algorithm Performance During Interval Management with Dynamic Arrival Trees (STARS)

Managing the interval between arrival aircraft is a major part of the en route and TRACON controller s job. In an effort to reduce controller workload and low altitude vectoring, algorithms have been developed to allow pilots to take responsibility for, achieve and maintain proper spacing. Additionally, algorithms have been developed to create dynamic weather-free arrival routes in the presence of convective weather. In a recent study we examined an algorithm to handle dynamic re-routing in the presence of convective weather and two distinct spacing algorithms. The spacing algorithms originated from different core algorithms; both were enhanced with trajectory intent data for the study. These two algorithms were used simultaneously in a human-in-the-loop (HITL) simulation where pilots performed weather-impacted arrival operations into Louisville International Airport while also performing interval management (IM) on some trials. The controllers retained responsibility for separation and for managing the en route airspace and some trials managing IM. The goal was a stress test of dynamic arrival algorithms with ground and airborne spacing concepts. The flight deck spacing algorithms or controller managed spacing not only had to be robust to the dynamic nature of aircraft re-routing around weather but also had to be compatible with two alternative algorithms for achieving the spacing goal. Flight deck interval management spacing in this simulation provided a clear reduction in controller workload relative to when controllers were responsible for spacing the aircraft. At the same time, spacing was much less variable with the flight deck automated spacing. Even though the approaches taken by the two spacing algorithms to achieve the interval management goals were slightly different they seem to be simpatico in achieving the interval management goal of 130 sec by the TRACON boundary.

Battiste, Vernol↗

Interval Management: Development and Implementation of an Airborne Spacing Concept

Interval Management is a suite of ADS-B-enabled applications that allows the air traffic controller to instruct a flight crew to achieve and maintain a desired spacing relative to another aircraft. The flight crew, assisted by automation, manages the speed of their aircraft to deliver more precise inter-aircraft spacing than is otherwise possible, which increases traffic throughput at the same or higher levels of safety. Interval Management has evolved from a long history of research and is now seen as a core NextGen capability. With avionics standards recently published, completion of an Investment Analysis Readiness Decision by the FAA, and multiple flight tests planned, Interval Management will soon be part of everyday use in the National Airspace System. Second generation, Advanced Interval Management capabilities are being planned to provide a wider range of operations and improved performance and benefits. This paper briefly reviews the evolution of Interval Management and describes current development and deployment plans. It also reviews concepts under development as the next generation of applications.

Barmore, Bryan E.↗

Application of Interval Predictor Models to Space Radiation Shielding

This paper develops techniques for predicting the uncertainty range of an output variable given input-output data. These models are called Interval Predictor Models (IPM) because they yield an interval valued function of the input. This paper develops IPMs having a radial basis structure. This structure enables the formal description of (i) the uncertainty in the models parameters, (ii) the predicted output interval, and (iii) the probability that a future observation would fall in such an interval. In contrast to other metamodeling techniques, this probabilistic certi cate of correctness does not require making any assumptions on the structure of the mechanism from which data are drawn. Optimization-based strategies for calculating IPMs having minimal spread while containing all the data are developed. Constraints for bounding the minimum interval spread over the continuum of inputs, regulating the IPMs variation/oscillation, and centering its spread about a target point, are used to prevent data over tting. Furthermore, we develop an approach for using expert opinion during extrapolation. This metamodeling technique is illustrated using a radiation shielding application for space exploration. In this application, we use IPMs to describe the error incurred in predicting the ux of particles resulting from the interaction between a high-energy incident beam and a target.

Crespo, Luis G.↗

Modeling Relationships Between Flight Crew Demographics and Perceptions of Interval Management

The Interval Management Alternative Clearances (IMAC) human-in-the-loop simulation experiment was conducted to assess interval management system performance and participants' acceptability and workload while performing three interval management clearance types. Twenty-four subject pilots and eight subject controllers flew ten high-density arrival scenarios into Denver International Airport during two weeks of data collection. This analysis examined the possible relationships between subject pilot demographics on reported perceptions of interval management in IMAC. Multiple linear regression models were created with a new software tool to predict subject pilot questionnaire item responses from demographic information. General patterns were noted across models that may indicate flight crew demographics influence perceptions of interval management.

Remy, Benjamin↗

Association Between Dispatch Complaint and Critical Prehospital Time Intervals in Suspected Stroke 911 Activations in the National Emergency Medical Services Information System, 2012–2016

Emergency Medical Services can help improve stroke outcomes by recognizing stroke symptoms, establishing response priority for 911 calls, and minimizing prehospital delays. This study examines 911 stroke events and evaluates associations between events dispatched as stroke and critical EMS time intervals. Data from the National Emergency Medical Services Information System, 2012 to 2016, were analyzed. Activations from 911 calls with a primary or secondary provider impression of stroke were included for adult patients transported to a hospital destination. Three prehospital time intervals were evaluated: (1) response time (RT) ≤8 min, (2) on-scene time (OST) ≤15 min, and (3) transport time (TT) ≤12 min. Associations between stroke dispatch complaint and prehospital time intervals were assessed using multivariate regression to estimate adjusted risk ratios (ARR) and 95% confidence intervals (CIs). Approximately 37% of stroke dispatch complaints were identified by EMS as a suspected stroke. Compared to stroke events without a stroke dispatch complaint, median OST was shorter for events with a stroke dispatch (16 min vs. 14 min, respectively). In adjusted analyses, events dispatched as stroke were more likely to meet the EMS time benchmark for OST ≤15 min (OST, 1.20 [1.20–1.21]), but not RT or TT (RT, [1.00–1.01]; TT, 0.95 [0.94–0.95]). Furthermore, our results indicate that dispatcher recognition of stroke symptoms reduces the time spent on-scene by EMS personnel. These findings can inform future EMS stroke education and quality improvement efforts to emphasize dispatcher recognition of stroke signs and symptoms, as EMS dispatchers play a crucial role in optimizing the prehospital response.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of Onset Mechanisms of a Sphingosine 1-Phosphate Receptor Modulator Fingolimod-Induced Atrioventricular Conduction Block and QT-Interval Prolongation

Fingolimod, a sphingosine 1-phosphate (S1P) receptor subtype 1, 3, 4 and 5 modulator, has been used for the treatment of patients with relapsing forms of multiple sclerosis, but atrioventricular conduction block and/or QT-interval prolongation have been reported in some patients after the first dose. In this study, we directly compared the electropharmacological profiles of fingolimod with those of siponimod, a modulator of sphingosine 1-phosphate receptor subtype 1 and 5, using in vivo guinea-pig model and in vitro human ether-a-go-go-related gene (hERG) assay to better understand the onset mechanisms of the clinically observed adverse events. Fingolimod (0.01 and 0.1 mg/kg) or siponimod (0.001 and 0.01 mg/kg) was intravenously infused over 10 min to the halothane-anaesthetized guinea pigs (n = 4), whereas the effects of fingolimod (1 μmol/L) and siponimod (1 μmol/L) on hERG current were examined (n = 3). The high doses of fingolimod and siponimod induced atrioventricular conduction block, whereas the low dose of siponimod prolonged PR interval, which was not observed by that of fingolimod. The high dose of fingolimod prolonged QT interval, which was not observed by either dose of siponimod. Meanwhile, fingolimod significantly inhibited hERG current, which was not observed by siponimod. These results suggest that S1P receptor subtype 1 in the heart could be one of the candidates for fingolimod- and siponimod-induced atrioventricular conduction block since S1P receptor subtype 5 is localized at the brain, and that direct I{sub Kr} inhibition may play a key role in fingolimod-induced QT-interval prolongation. - Highlights: • Fingolimod and siponimod are S1P{sub 1,3,4,5} and S1P{sub 1,5} receptor modulators, respectively. • Fingolimod and siponimod induced AV block in the halothane-anesthetized guinea pigs. • S1P{sub 1} in the hearts may be the target of fingolimod- and siponimod-induced AV block. • Fingolimod directly inhibited hERG current, which was not observed by siponimod. • I{sub Kr} inhibition may play a key role in the fingolimod-induced QT prolongation.

60 APPLIED LIFE SCIENCES↗

Clustering Interval Load with Weather to Create Scenarios of Behind-the-Meter Solar Penetration

Forecasting load at the feeder level has become increasingly challenging with the penetration of behind-the-meter solar, as this self-generation is only visible to the utility as aggregated net-load. This work proposes a methodology for creation of scenarios of solar penetration at the feeder level for use by forecasters to test the robustness of their algorithm to progressively higher penetrations of solar. The algorithm draws on publicly available observations of weather condition (e.g., rainy/cloudy/fair) for use as proxies to sky clearness. These observations are used to mask and weight the interval deviations of similar native usage profiles from which average interval usage is calculated and subsequently added to interval net generation to reconstruct interval total generation. This approach improves the estimate of annual energy generation by 23%; where the net generation signal currently reflects 52% of total annual gener- ation, now 75% is captured. This methodology for creation of forecast testing scenarios is data driven and extensible to service territories which lack information on irradiance measurements and geocoordinates.

solar, load↗

Statistical variability and confidence intervals for planar dose QA pass rates

Purpose: The most common metric for comparing measured to calculated dose, such as for pretreatment quality assurance of intensity-modulated photon fields, is a pass rate (%) generated using percent difference (%Diff), distance-to-agreement (DTA), or some combination of the two (e.g., gamma evaluation). For many dosimeters, the grid of analyzed points corresponds to an array with a low areal density of point detectors. In these cases, the pass rates for any given comparison criteria are not absolute but exhibit statistical variability that is a function, in part, on the detector sampling geometry. In this work, the authors analyze the statistics of various methods commonly used to calculate pass rates and propose methods for establishing confidence intervals for pass rates obtained with low-density arrays. Methods: Dose planes were acquired for 25 prostate and 79 head and neck intensity-modulated fields via diode array and electronic portal imaging device (EPID), and matching calculated dose planes were created via a commercial treatment planning system. Pass rates for each dose plane pair (both centered to the beam central axis) were calculated with several common comparison methods: %Diff/DTA composite analysis and gamma evaluation, using absolute dose comparison with both local and global normalization. Specialized software was designed to selectively sample the measured EPID response (very high data density) down to discrete points to simulate low-density measurements. The software was used to realign the simulated detector grid at many simulated positions with respect to the beam central axis, thereby altering the low-density sampled grid. Simulations were repeated with 100 positional iterations using a 1 detector/cm{sup 2} uniform grid, a 2 detector/cm{sup 2} uniform grid, and similar random detector grids. For each simulation, %/DTA composite pass rates were calculated with various %Diff/DTA criteria and for both local and global %Diff normalization techniques. Results: For the prostate and head/neck cases studied, the pass rates obtained with gamma analysis of high density dose planes were 2%-5% higher than respective %/DTA composite analysis on average (ranging as high as 11%), depending on tolerances and normalization. Meanwhile, the pass rates obtained via local normalization were 2%-12% lower than with global maximum normalization on average (ranging as high as 27%), depending on tolerances and calculation method. Repositioning of simulated low-density sampled grids leads to a distribution of possible pass rates for each measured/calculated dose plane pair. These distributions can be predicted using a binomial distribution in order to establish confidence intervals that depend largely on the sampling density and the observed pass rate (i.e., the degree of difference between measured and calculated dose). These results can be extended to apply to 3D arrays of detectors, as well. Conclusions: Dose plane QA analysis can be greatly affected by choice of calculation metric and user-defined parameters, and so all pass rates should be reported with a complete description of calculation method. Pass rates for low-density arrays are subject to statistical uncertainty (vs. the high-density pass rate), but these sampling errors can be modeled using statistical confidence intervals derived from the sampled pass rate and detector density. Thus, pass rates for low-density array measurements should be accompanied by a confidence interval indicating the uncertainty of each pass rate.

61 RADIATION PROTECTION AND DOSIMETRY↗

Burst delay line for generating ultrashort pulse bursts with interval tunability from femtoseconds to nanoseconds.

Ultrashort burst laser pulses are important for applications in laser processing and spectroscopy. However, existing burst generators face limitations in pulse time interval tunability and coaxiality. Here, we present a burst pulse generator that delivers coaxial ultrashort pulses with tunable pulse time intervals using a single translation stage. The constructed system produced eight femtosecond pulses with uniform intervals tunable from 100 fs to 1.93 ns, equivalent to burst-internal repetition rates spanning 10 THz to 0.52 GHz. We further demonstrated interval-dependent plasma emission in air filamentation, providing a compact platform to study burst-laser-induced phenomena.

Shimada, Keitaro↗

Correction of confidence intervals in excess relative risk models using Monte Carlo dosimetry systems with shared errors

Introduction: Measurement errors are ubiquitous in epidemiological studies, especially for doses arising from environmental and occupational exposures, which are difficult to assess. Correction methods for independent measurement errors, have been comprehensively described elsewhere, including regression calibration, simulation extrapolation (SIMEX), etc. However, when exposure estimates are constructed using complicated physical and biological models, uncertainties in the dosimetry system can become very complex. In such systems, uncertainties in some parameters may affect a large group of study participants simultaneously, and hence are “shared” as opposed to independent dosimetric uncertainties. Representing the structure of the uncertainty in the dosimetry by providing multiple realizations of possible dose has been described for several studies. The goal of this paper is to implement, and explore the properties of, a generalized estimating equation-based approach to shared uncertainties based on principles described in an earlier paper. Methods: The effects of shared and unshared dosimetry error on parameter estimates and confidence intervals in a generalized excess relative risk model are examined. A post-hoc correction method is implemented that constructs corrected confidence intervals based on an underlying variance structure described in an earlier paper. In this correction method it is assumed that the estimated slope parameter in a linear excess relative risk model is distributed as a mixture of normal and lognormal components. A simulation study of the behavior of this correction was developed based on multiple realizations provided by the Monte Carlo dosimetry system used for the plutonium exposures in the Mayak Worker Cohort and a risk model with close similarity to that used in analyses of lung cancer data in that cohort. Results: In the simulation study we found that shared dose errors severely degraded the coverage probabilities of confidence limits for the slope parameter in the linear excess relative risk model relating uncertain exposure to lung cancer risk. Using our correction method to adjust the confidence intervals provided much improved coverage probabilities for this parameter. A smaller amount of degradation in confidence interval coverage for other parameters (e.g. those in the baseline and dose modification terms) was noted, and the proposed correction method also improved coverage for these parameters as well. Discussion: Compared to other recently described methods our proposed correction method relies on relatively familiar software to fit dose response models. The basic modeling philosophy described here first uses existing Poisson regression methods to estimate parameters in the excess relative risk model; in this first stage mean dose (computed from the multiple realizations) is used as the independent variable in the regression. Once the model is fit we then correct (widen) the standard errors for all parameters using the proposed correction method. The simulation studies indicate that the methods described here are an important contribution to the available tools for dealing with shared measurement errors in complex risk analysis.

61 RADIATION PROTECTION AND DOSIMETRY↗

Identifying Suspect Instrument Intervals Using Midnight Noise Time Histories

With an intense work ethic, and high levels of devotion to their craft, seismologists continue to battle the elements and wrestle with complex logistics in their efforts to field instrumentation over the entire globe. We are fortunate to see data volumes accelerating in size, and quality continuing to improve; for example, universal timing issues can now be considered rare. However, instrument response issues are still common, and can hinder research that seeks to understand amplitudes of seismic wavefields. We are interested in using the accumulations of seismic data to develop models that will predict high frequency (0.2-20 Hz, and higher) signal amplitudes for explosion monitoring purposes over broad areas, which requires large data sets and extensive quality control. To identify response and station health issues, we have collected noise time histories for global seismic data, focusing on measurements near (but not restricted to) midnight to eliminate diurnal variations, and have manually determined time intervals that appear inconsistent with background behavior. We assign descriptive labels, but do not attempt to diagnose causes. We use these intervals to discard data. To date, we have examined 39,260 channels from 11,105 stations, heavily weighted toward IRIS holdings, dates through 2017 (depending on station, roughly the date we started our manual review), bands between 1 and 8 Hz, finding 24,733 anomalous time intervals. The great majority (90%) of these intervals appear to be shifts of constant offset, often bounded by times of known instrument changes, likely the result of poor documentation of response parameters at one of many stages between the field and the plotter. We hope these results can be of use to our colleagues, and would encourage community efforts to diagnose anomalous behavior, and fix poor responses. We also hope these results will support automation efforts, including application of supervised learning techniques.

47 OTHER INSTRUMENTATION↗

The benefits of using short interval satellite images to derive winds for tropical cyclones

During the 1975, 1976, and 1977, NOAA's National Environmental Satellite Service and NASA's Goddard Space Flight Center conducted a cooperative program to determine the optimum resolution and frequency of satellite images for deriving winds to study and forecast tropical cyclones. Rapid scan images were obtained at 7.5 minute interval from SMS-2 for hurricane Eloise and cyclone Caroline, and at 3 minute intervals from GOES-1 for tropical storms Belle, Holly, and Anita. Cloud motions were derived from these images using the Atmospheric and Oceanographic Information Processing System. Winds that were derived from the movement of upper and lower tropospheric level clouds using rapid scan data were compared with the 15 and 30 minute interval data. Greater than 10 (5) times as many clouds could be tracked to obtain winds using 3 and 7.5 minute rapid scan images as when using 15 or 30 minute interval images. A few bright areas within the central dense overcast which appeared to be moving with the winds at low levels were tracked.

Rodgers, E.↗