Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “internal dose coefficients”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

RAIS Slope Factors for Radionuclides

For a given radionuclide, Slope Factors (SFs) represent the ELCR equivalent per unit intake (i.e., ingestion or inhalation) or external exposure of that radionuclide. These SFs are used to convert a radionuclide concentration in soil, air, water, or foodstuffs to a radiation ELCR. The primary use of SFs, also called risk coefficients, is to compute the ELCR resulting from site-related exposures. This is accomplished by multiplying the route-specific SF by the CDI of each radionuclide of potential concern for each route of exposure. Ingestion and inhalation slope factors are central estimates in a linear model of the age-averaged, lifetime attributable radiation cancer incidence (fatal and nonfatal cancer) risk per unit of activity inhaled or ingested, expressed as risk/picocurie (pCi). External exposure SFs are central estimates of lifetime attributable radiation cancer incidence risk for each year of exposure to external radiation from photon-emitting radionuclides distributed uniformly in a thick layer of soil, expressed as risk/year per pCi/gram soil. External exposure SF units can also be risk/year per pCi/square centimeters (cm2) of soil. When combined with site-specific media concentration data and appropriate exposure assumptions, SFs can be used to estimate lifetime cancer risks to members of the general population due to radionuclide exposures. The SFs presented on are updated values from Federal Guidance Report (FGR) 13 supplement using the International Commission on Radiological Protection (ICRP) 107 decay data. The derivation and values are found in “Calculations of Slope Factors and Dose Coefficients” (ORNL, 2014).

Noto, Katie [Oak Ridge National Laboratory (ORNL),↗

Biokinetic models for radiocesium and its progeny

Over the next few years the International Commission on Radiological Protection (ICRP) will publish a series of reports containing updated biokinetic and dosimetric models and dose coefficients for occupational intake of radionuclides. The biokinetic modeling scheme continues a trend in modern ICRP reports toward physiologically realistic descriptions of the time-dependent behavior of absorbed radionuclides and ingrowing chain members. This paper proposes systemic biokinetic models for cesium isotopes and their chain members for use in these ICRP reports and examines dosimetric implications of the proposed models. Comparisons of A = tissue dose per unit input to blood based on current ICRP models for workers (ICRP Publication 68, 1994) with B = corresponding values based on the proposed biokinetic models (but using dosimetry models of Publication 68) yields the following ranges of ratios B:A for tissues addressed in current ICRP documents: 0.5-25 for 130Cs (T1/2 = 29.2 min), 0.6-9.5 for 134mCs (2.9 h), 0.8-2.2 for 129Cs (32.1 h), 0.7-1.7 for 131Cs (9.69 d), 0.8-1.3 for 136Cs (13.2 d), 0.7-1.1 for 134Cs (2.06 y), 0.5-1.9 for 137Cs (30.2 y), and 0.2-3.7 for 135Cs (2.3x106 y). The large differences in estimated tissue dose for some tissues and cesium isotopes, particularly short-lived isotopes, result mainly from differences in model predictions of the time-dependent distributions of cesium in the body. For example, the proposed and current ICRP models for cesium predict peak kidney contents of ~22% and ~0.4%, respectively, following intravenous injection of stable cesium. Based on the proposed models for cesium and its progeny, the only dosimetrically significant chain members of cesium isotopes are 137mBa, which represents 32-85% of the estimated tissue doses from injected 137Cs, and 134Cs, which represents 4-53% of the estimated tissue doses from injected 134mCs.

cesium biokinetics progeny dosimetry radiation pro↗

Long-lived contaminants in cyclotron-produced radiopharmaceuticals: measurement and dosimetry

Oxygenated target waters of cyclotron targets contain long-lived contaminants due to (p,n) reactions in the HAVAR target window that are spalled into the target water. These contaminants are largely removed during the synthesis of the final imaging agent. Currently the USP requires that the final drug product be 99.5% pure, so the total activity of the long-lived contaminants can be no more than 0.5% of the final radiopharmaceutical product. A method has been developed to identify and quantify the primary contaminants using high resolution gamma spectroscopy and VRF, a new spectrum analysis tool. Uptake, retention, and excretion functions for each of the contaminating isotopes in a soluble, injected chemical form have also been calculated using International Commission on Radiological Protection (ICRP) Publication 123 models and are presented in the Appendices A and B of Electronic Supplementary Material. In addition, specific organ and effective dose coefficients were also calculated using ICRP Publication 103 tissue weighting factors and are also presented in the Appendices A and B of Electronic Supplementary Material. As a result, typical imaging agents have contaminant loads far below the USP limit and contribute negligible doses to the patients receiving the drugs.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Evaluation of Dose Coefficients Implemented in MACCS

A variety of dose conversion factor files (DCF files) have been supplied for use with the MACCS code since it was initially released. For MACCS 4.2, the MACCS DCF files have been updated to include coefficients used in the computation of acute skin doses from within the MACCS software to increase functionality and to add a pseudo-organ to represent the total effective dose equivalent (TEDE) (as defined in 10 CFR 20.1003) based on International Commission on Radiological Protection (ICRP) Publication 30. This report provides a description of how these changes have been implemented and a summary of the various DCF files supplied with MACCS 4.2. The report also provides supplemental discussions to assist the reader in understanding the technical basis for the MACCS DCFs. These supplemental discussions include a summary of basic dosimetry modeling concepts and a brief review of the Federal Guidance Reports (FGRs) upon which MACCS dose coefficients have historically been based.

97 MATHEMATICS AND COMPUTING↗

Development of a series of Korean pediatric and adult head computational phantoms and application to nuclear medicine dosimetry - Paper 26

Over the past decades, advances in Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) imaging techniques and an increasing number of new radiopharmaceuticals have resulted in a surge of neuroimaging applications in nuclear medicine on pediatric and adult patients. It is not feasible to directly measure the absorbed dose to the organs of the human body from nuclear medicine procedures. The formalism of the Medical Internal Radiation Dose (MIRD) committee of the Society of Nuclear Medicine has been adopted as the calculation method to estimate radiation dose to target organs from radionuclides distributed in source organs. The absorbed dose to a target organ from different types of radionuclides distributed within source organs can be estimated by the products of the time-integrated activity in each source region and organ dose conversion coefficients, called S values (Gy/MBq-s). S values are computed from a comprehensive set of Specific Absorbed Fraction (SAF), which are calculated from computational human phantoms with realistic anatomical structures coupled with Monte Carlo transport technique. The current SAF data for pediatric and adult head and brain dosimetry is based on a series of stylized computational phantoms. However, dosimetric errors caused by the unrealistic anatomy of stylized phantoms in internal dosimetry calculations have been reported by several studies. In the current study, we developed a series of realistic computational head phantoms representing 6, 9, 12, 15, and 22-year-old standard Korean males, and computed a comprehensive set of SAFs using the phantoms coupled with Monte Carlo transport technique. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

A Dosimetric Comparison of Tomotherapy and Volumetric Modulated Arc Therapy in the Treatment of High-Risk Prostate Cancer With Pelvic Nodal Radiation Therapy

Purpose: To compare the dosimetric results of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy. Methods and Materials: Plans were generated for 10 consecutive patients treated for high-risk prostate cancer with prophylactic whole pelvic radiation therapy (WPRT) using VMAT and HT. After WPRT, a sequential boost was delivered to the prostate. Plan quality was assessed according to the criteria of the International Commission on Radiation Units and Measurements 83 report: the near-minimal (D98%), near-maximal (D2%), and median (D50%) doses; the homogeneity index (HI); and the Dice similarity coefficient (DSC). Beam-on time, integral dose, and several organs at risk (OAR) dosimetric indexes were also compared. Results: For WPRT, HT was able to provide a higher D98% than VMAT (44.3 {+-} 0.3 Gy and 43.9 {+-} 0.5 Gy, respectively; P=.032) and a lower D2% than VMAT (47.3 {+-} 0.3 Gy and 49.1 {+-} 0.7 Gy, respectively; P=.005), leading to a better HI. The DSC was better for WPRT with HT (0.89 {+-} 0.009) than with VMAT (0.80 {+-} 0.02; P=.002). The dosimetric indexes for the prostate boost did not differ significantly. VMAT provided better rectum wall sparing at higher doses (V70, V75, D2%). Conversely, HT provided better bladder wall sparing (V50, V60, V70), except at lower doses (V20). The beam-on times for WPRT and prostate boost were shorter with VMAT than with HT (3.1 {+-} 0.1 vs 7.4 {+-} 0.6 min, respectively; P=.002, and 1.5 {+-} 0.05 vs 3.7 {+-} 0.3 min, respectively; P=.002). The integral dose was slightly lower for VMAT. Conclusion: VMAT and HT provided very similar and highly conformal plans that complied well with OAR dose-volume constraints. Although some dosimetric differences were statistically significant, they remained small. HT provided a more homogeneous dose distribution, whereas VMAT enabled a shorter delivery time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Competitive Metabolism of Polycyclic Aromatic Hydrocarbons (PAHs): An Assessment Using In Vitro Metabolism and Physiologically Based Pharmacokinetic (PBPK) Modeling

Humans are routinely exposed to complex mixtures such as polycyclic aromatic hydrocarbons (PAHs) rather than to single compounds, as are often assessed for hazards. Cytochrome P450 enzymes (CYPs) metabolize PAHs, and multiple PAHs found in mixtures can compete as substrates for individual CYPs (e.g., CYP1A1, CYP1B1, etc.). The objective of this study was to assess competitive inhibition of metabolism of PAH mixtures in humans and evaluate a key assumption of the Relative Potency Factor approach that common human exposures will not cause interactions among mixture components. To test this objective, we co-incubated binary mixtures of benzo[a]pyrene (BaP) and dibenzo[def,p]chrysene (DBC) in human hepatic microsomes and measured rates of enzymatic BaP and DBC disappearance. We observed competitive inhibition of BaP and DBC metabolism and measured inhibition coefficients (K i ), observing that BaP inhibited DBC metabolism more potently than DBC inhibited BaP metabolism (0.061 vs. 0.44 µM K i , respectively). We developed a physiologically based pharmacokinetic (PBPK) interaction model by integrating PBPK models of DBC and BaP and incorporating measured metabolism inhibition coefficients. The PBPK model predicts significant increases in BaP and DBC concentrations in blood AUCs following high oral doses of PAHs (≥100 mg), five orders of magnitude higher than typical human exposures. We also measured inhibition coefficients of Supermix-10, a mixture of the most abundant PAHs measured at the Portland Harbor Superfund Site, on BaP and DBC metabolism. We observed similar potencies of inhibition coefficients of Supermix-10 compared to BaP and DBC. Overall, results of this study demonstrate that these PAHs compete for the same enzymes and, at high doses, inhibit metabolism and alter internal dosimetry of exposed PAHs. This approach predicts that BaP and DBC exposures required to observe metabolic interaction are much higher than typical human exposures, consistent with assumptions used when applying the Relative Potency Factor approach for PAH mixture risk assessment.

54 ENVIRONMENTAL SCIENCES↗

Transfer functions for Q A /Q B international regulatory limits for the safe transport of radioactive materials

This paper presents a proposed revision of the International Atomic Energy Agency transport regulations, related to the A 1 and A 2 limit values used to determine the radioactive transport classification. Based on the 'Q system', a novel methodology was introduced to derive Q A and Q B values related to scenarios involving external exposure from a distant source. These values are key parameters that respectively represent the total effective dose and total equivalent dose to the skin, from all primary and secondary particles contributing to radiation exposure. The International Working Group (WG A 1 /A 2 ) is established and associated with the TRANSSC Technical Expert Group on Radiation Protection. A review of the A 1 and A 2 values is performed in response to identified limitations within the existing Q system. The followed approach is based on Monte Carlo simulations that enabled the development of transfer functions aimed at reducing computational time and increasing the flexibility of dose evaluations for any radionuclide with known particle emission spectra. This method allows updating the Q A and Q B values to account for future data evolutions (decay data, fluence-to-dose conversion coefficients) and standardizing the calculation of regulation limits across all referenced radionuclides and scenarios related to external exposure. The transfer functions are established using three Monte Carlo simulation codes—FLUKA, Geant4, and MCNP—and address the previous limitations of the 'Q system', reflecting the latest International Commission for Radiation Protection recommendations and improvements in calculation techniques. The results of the WG show consistent agreement across the codes, with minor discrepancies observed at low primary energies due to statistical uncertainties and different handling of stopping power for electrons/positrons in the codes. This revised approach aligns with current standards and recommendations, ensuring that the radiological consequences of transport accidents are acceptable for the new A 1 and A 2 limits from a radiological protection perspective.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of the Neutron Fields in the Lawrence Livermore National Laboratory (LLNL) Radiation Calibration Laboratory Low Scatter Calibration Facility

In June 2007, the Department of Energy (DOE) revised its rule on Occupational Radiation Protection, Part 10 CFR 835. A significant aspect of the revision was the adoption of the recommendations outlined in International Commission on Radiological Protection (ICRP) Report 60 (ICRP-60), including new radiation weighting factors for neutrons, updated internal dosimetric models, and dose terms consistent with the newer ICRP recommendations. ICRP-60 uses the quantities defined by the International Commission on Radiation Units and Measurements (ICRU) for personnel and area monitoring including the ambient dose equivalent H*(d). A Joint Task Group of ICRU and ICRP has developed various fluence-to-dose conversion coefficients which are published in ICRP-74 for both protection and operational quantities. In February 2008, Lawrence Livermore National Laboratory (LLNL) replaced its old pneumatic transport neutron irradiation system in the Radiation Calibration Laboratory (RCL) Low Scatter Calibration Facility (B255, Room 183A) with a Hopewell Designs irradiator model N40. The exposure tube for the Hopewell system is located close to, but not in exactly the same position as the exposure tube for the pneumatic system. Additionally, the sources for the Hopewell system are stored in Room 183A where, prior to the change, they were stored in a separate room (Room 183C). The new source configuration and revision of the 10 CFR 835 radiation weighting factors necessitate a re-evaluation of the neutron dose rates in B255 Room 183A. This report deals only with the changes in the operational quantities ambient dose equivalent and ambient dose rate equivalent for neutrons as a result of the implementation of the revised 10 CFR 835. In the report, the terms 'neutron dose' and 'neutron dose rate' will be used for convenience for ambient neutron dose equivalent and ambient neutron dose rate equivalent unless otherwise stated.

61 RADIATION PROTECTION AND DOSIMETRY↗

Biokinetics of 238 Pu oxides: Inferences from bioassay data

The bioassay data collected from several workers involved in 238 Pu inhalation incidents have been analyzed using the most recent biokinetic models described in Occupational Intakes of Radionuclides (OIR) series of publications. Although all exposures were thought to be to 238 Pu oxides, the observed urinary excretion patterns differed in different inhalation incidents. The urinary excretion from individuals involved in one of the incidents increased steadily with time peaking around 2-3 years before decreasing. This pattern is described in Part 4 of the OIR series using the ‘ 238 PuO 2 , ceramic’ model. This non-monotonic behavior, explained as being due to fragmentation and dissolution, was not specific to the incident, but was also observed in other incidents. The urinary excretion data collected from individuals involved in another incident showed dissolution behavior between Type M and Type S. Finally, the bioassay data from yet another incident showed a pattern that appears to represent behavior more insoluble than Type S, which is possibly a result of self-heating due to the decay heat from 238 Pu. The urinary excretion patterns and the corresponding dose coefficients have been calculated and compared.

238Pu↗

Potential improvements in brain dose estimates for internal emitters

Background: Element-specific biokinetic models are used to reconstruct doses to systemic tissues from internal emitters. Typically, a systemic model for a radionuclide explicitly depicts only its dominant repositories. Remaining tissues and fluids are aggregated into a pool called Other tissue in which the radionuclide is assumed to be uniformly distributed. In the systemic biokinetic models used in radiation protection, the brain usually is addressed as an implicit mass fraction of Other tissue rather than an explicitly depicted repository. Additionally, due to increasing interest in radiation effects on the brain, efforts are underway to improve brain dosimetry for internal radiation sources. Methods: We assessed potential improvements in brain dosimetry for internal emitters by explicitly modelling brain kinetics rather than treating the brain as a mass fraction of Other tissue. We selected ten elements for which brain kinetics can be modeled using published biokinetic data. Injection dose coefficients were calculated for a relatively long-lived radioisotope of each element using each of two versions of the ICRP’s latest systemic biokinetic model for each element, the original version and a modified version differing only in the treatment of brain. If the ICRP model contained an explicit brain pool, the modified version depicted brain instead as a mass fraction of Other tissue. If the ICRP model included brain in Other tissue, the modified version included an explicit brain pool with kinetics based on best available brain-specific data.Results: The result for a given radionuclide is expressed as a ratio A:B, where A and B are the dose coefficients based on the versions of the model with and without an explicit brain pool, respectively. The following ratios A:B were obtained for the 10 radionuclides addressed here: 241 Am, 0.13; 207 Bi, 0.57; 234 U, 0.81; 239 Pu, 0.96; 203 Hg (vapor), 1.4; 134 Cs, 1.5; 54 Mn, 1.7; 210 Po, 1.7; 226 Ra, 1.9; 210 Pb, 3.3. These ratios indicate that a dose estimate for brain based on a biokinetic model with brain implicitly contained in Other tissue may substantially underestimate or substantially overestimate a dose estimate that reflects best available brain-specific biokinetic data. Of course, the reliability of the latter estimate depends on the quality of the underlying biokinetic data.Conclusions: Finally, where feasible, the brain should be depicted explicitly in biokinetic models used in epidemiological studies addressing adverse effects of ionizing radiation.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-T-56: A Novel Approach to Computing Expected Value and Variance of Point Dose From Non-Gated Radiotherapy Delivery

Purpose: Randomness in patient internal organ motion phase at the beginning of non-gated radiotherapy delivery may introduce uncertainty to dose received by the patient. Concerns of this dose deviation from the planned one has motivated many researchers to study this phenomenon although unified theoretical framework for computing it is still missing. This study was conducted to develop such framework for analyzing the effect. Methods: Two reasonable assumptions were made: a) patient internal organ motion is stationary and periodic; b) no special arrangement is made to start a non -gated radiotherapy delivery at any specific phase of patient internal organ motion. A statistical ensemble was formed consisting of patient’s non-gated radiotherapy deliveries at all equally possible initial organ motion phases. To characterize the patient received dose, statistical ensemble average method is employed to derive formulae for two variables: expected value and variance of dose received by a patient internal point from a non-gated radiotherapy delivery. Fourier Series was utilized to facilitate our analysis. Results: According to our formulae, the two variables can be computed from non-gated radiotherapy generated dose rate time sequences at the point’s corresponding locations on fixed phase 3D CT images sampled evenly in time over one patient internal organ motion period. The expected value of point dose is simply the average of the doses to the point’s corresponding locations on the fixed phase CT images. The variance can be determined by time integration in terms of Fourier Series coefficients of the dose rate time sequences on the same fixed phase 3D CT images. Conclusion: Given a non-gated radiotherapy delivery plan and patient’s 4D CT study, our novel approach can predict the expected value and variance of patient radiation dose. We expect it to play a significant role in determining both quality and robustness of patient non-gated radiotherapy plan.

60 APPLIED LIFE SCIENCES↗

TH-A-204-00: Key Dosimetry Data - Impact of New ICRU Recommendations

The ICRU is currently finalizing a report on key data for radiation dosimetry. This multi-year review has resulted in a number of recommendations regarding “fundamental” data that are used in dosimetry related to radiation therapy. This educational session will explain the background for the ICRU committee’s work, the content and conclusions of the report and the impact on outputs, including NIST primary standards, ADCL calibration coefficients and clinical reference dosimetry. Parameters and beam modalities potentially affected by this report include: The mean excitation energy, I, for graphite, air, and water, The average energy required to create an ion pair in dry air (commonly referred to as W/e), The uncertainty in the determination of air kerma in kV xrays The absolute value of Co-60 and Cs-137 primary standards and the dissemination of calibration coefficients, The determination of air kerma strength for Ir-192 HDR brachytherapy sources Ion chamber kQ factors for linac MV beams Ion chamber kQ factors for proton beams. The changes in reference dosimetry that would result from adoption of the ICRU recommendations are of the order of 0.5% to 1%, an effect that will not impact clinical dose delivery but will be detectable in the clinical setting. This session will also outline how worldwide metrology is coordinated through the Convention of the Meter and therefore how the international dosimetry community will proceed with adopting these recommendations so that uniformity from country to country in reference dosimetry is maintained. Timelines and communications methods will also be discussed to ensure that users, such as clinical medical physicists, are not surprised when their chamber’s calibration coefficient apparently changes. Learning Objectives: Understand the background for the ICRU committee’s work on key dosimetry data. Understand the proposed changes to key data and the impacts on reference dosimetry. Understand the methodology and timeline for adoption of the ICRU recommendations.

07 ISOTOPE AND RADIATION SOURCES↗

TH-A-204-01: Part I - Key Data for Ionizing-Radiation Dosimetry

The ICRU is currently finalizing a report on key data for radiation dosimetry. This multi-year review has resulted in a number of recommendations regarding “fundamental” data that are used in dosimetry related to radiation therapy. This educational session will explain the background for the ICRU committee’s work, the content and conclusions of the report and the impact on outputs, including NIST primary standards, ADCL calibration coefficients and clinical reference dosimetry. Parameters and beam modalities potentially affected by this report include: The mean excitation energy, I, for graphite, air, and water, The average energy required to create an ion pair in dry air (commonly referred to as W/e), The uncertainty in the determination of air kerma in kV x-rays The absolute value of Co-60 and Cs-137 primary standards and the dissemination of calibration coefficients, The determination of air kerma strength for Ir-192 HDR brachytherapy sources Ion chamber kQ factors for linac MV beams Ion chamber kQ factors for proton beams. The changes in reference dosimetry that would result from adoption of the ICRU recommendations are of the order of 0.5% to 1%, an effect that will not impact clinical dose delivery but will be detectable in the clinical setting. This session will also outline how worldwide metrology is coordinated through the Convention of the Meter and therefore how the international dosimetry community will proceed with adopting these recommendations so that uniformity from country to country in reference dosimetry is maintained. Timelines and communications methods will also be discussed to ensure that users, such as clinical medical physicists, are not surprised when their chamber’s calibration coefficient apparently changes. Learning Objectives: Understand the background for the ICRU committee’s work on key dosimetry data. Understand the proposed changes to key data and the impacts on reference dosimetry. Understand the methodology and timeline for adoption of the ICRU recommendations.

60 APPLIED LIFE SCIENCES↗

TH-A-204-02: Part II - Worldwide Radiation Metrology

The ICRU is currently finalizing a report on key data for radiation dosimetry. This multi-year review has resulted in a number of recommendations regarding “fundamental” data that are used in dosimetry related to radiation therapy. This educational session will explain the background for the ICRU committee’s work, the content and conclusions of the report and the impact on outputs, including NIST primary standards, ADCL calibration coefficients and clinical reference dosimetry. Parameters and beam modalities potentially affected by this report include: The mean excitation energy, I, for graphite, air, and water, The average energy required to create an ion pair in dry air (commonly referred to as W/e), The uncertainty in the determination of air kerma in kV x-rays The absolute value of Co-60 and Cs-137 primary standards and the dissemination of calibration coefficients, The determination of air kerma strength for Ir-192 HDR brachytherapy sources Ion chamber kQ factors for linac MV beams Ion chamber kQ factors for proton beams. The changes in reference dosimetry that would result from adoption of the ICRU recommendations are of the order of 0.5% to 1%, an effect that will not impact clinical dose delivery but will be detectable in the clinical setting. This session will also outline how worldwide metrology is coordinated through the Convention of the Meter and therefore how the international dosimetry community will proceed with adopting these recommendations so that uniformity from country to country in reference dosimetry is maintained. Timelines and communications methods will also be discussed to ensure that users, such as clinical medical physicists, are not surprised when their chamber’s calibration coefficient apparently changes. Learning Objectives: Understand the background for the ICRU committee’s work on key dosimetry data. Understand the proposed changes to key data and the impacts on reference dosimetry. Understand the methodology and timeline for adoption of the ICRU recommendations.

60 APPLIED LIFE SCIENCES↗

Radiation Doses to Members of the U.S. Population from Ubiquitous Radionuclides in the Body: Part 3, Results, Variability, and Uncertainty

This paper is part three of a three-part series investigating annual effective doses to residents of the United States from intakes of ubiquitous radionuclides, including radionuclides occurring naturally, radionuclides whose concentrations are technologically enhanced, and anthropogenic radionuclides. The radionuclides of interest are the 238U series (14 nuclides), the actinium series (headed by 235U; 11 nuclides), and the 232Th series (11 nuclides); primordial radionuclides 87Rb and 40K; cosmogenic and fallout radionuclides 14C and 3H; and purely anthropogenic radionuclides 137Cs-137mBa, 129I and 90Sr-90Y. This series of papers explicitly excludes intakes from inhaling 222Rn, 220Rn, and their short-lived decay products; it also excludes intakes of radionuclides in occupational and medical settings. Part one reviewed, summarized, characterized, and grouped all published and some unpublished data for U.S. residents on ubiquitous radionuclide concentrations in tissues and organs. Part two described the methods used to organize the data collected in part one and segregate it into the ages and genders defined by the study, imputed missing values from the existing data, apportioned activity in bone, and imputed activity in hollow organ contents and the remainder of the body. This paper estimates equivalent doses to target tissues from source regions and maps target tissues to lists of tissues with International Commission on Radiation Protection (ICRP) tissue-weighting factors or to surrogate tissue regions when there is no direct match. Effective doses, using ICRP tissue-weighting factors recommended in 1977, 1990, and 2007, are then calculated, and an upper bound of variability of the effective dose is estimated by calculating the average coefficients of variation (CV), assuming all variance is due to variability. Most of the data were for adult males, whose average annual effective dose is estimated to be 337 μSv (CV = 0.65, geometric mean = 283 μSv, geometric standard deviation sG = 1.81) using 2007 ICRP tissue-weighting factors. This result is between the National Council on Radiation Protection & Measurements’ 1987 estimate of 390 μSv (using 1977 wTs) and its 2009 estimate of 285 μSv (using 2007 wTs) and is higher than the United Nations Scientific Committee on the Effects of Atomic Radiation’s 2000 estimate of 310 μSv (using 1990 wTs). The methods and software developed for this project are sufficiently detailed and sufficiently general to be usable with autopsy data from any or all countries.

59 BASIC BIOLOGICAL SCIENCES↗

Proficiency Testing as a tool to monitor consistency of measurements in the IAEA/WHO Network of Secondary Standards Dosimetry Laboratories

The International Atomic Energy Agency (IAEA) and the World Health Organization (WHO) established a Network of Secondary Standards Dosimetry Laboratories (IAEA/WHO SSDL Network) in 1976. Through SSDLs designated by Member States, the Network provides a direct link of national dosimetry standards to the international measurement system of standards traceable to the Bureau International des Poids et Mesures (BIPM). Within this structure and through the proper calibration of field instruments, the SSDLs disseminate S.I. quantities and units.To ensure that the services provided by SSDL members to end-users follow internationally accepted standards, the IAEA has set up two different comparison programmes. One programme relies on the IAEA/WHO postal TLD service and the other uses comparisons of calibrated ionization chambers to help the SSDLs verify the integrity of their national standards and the procedures used for the transfer of the standards to the end-users. The IAEA comparisons include {sup 60}Co air kerma (N{sub K}) and absorbed dose to water (N{sub D,W}) coefficients. The results of the comparisons are confidential and are communicated only to the participants. This is to encourage participation of the laboratories and their full cooperation in the reconciliation of any discrepancy.This work describes the results of the IAEA programme comparing calibration coefficients for radiotherapy dosimetry, using ionization chambers. In this programme, ionization chambers that belong to the SSDLs are calibrated sequentially at the SSDL, at the IAEA, and again at the SSDL. As part of its own quality assurance programme, the IAEA has participated in several regional comparisons organized by Regional Metrology Organizations.The results of the IAEA comparison programme show that the majority of SSDLs are capable of providing calibrations that fall inside the acceptance level of 1.5% compared to the IAEA.

61 RADIATION PROTECTION AND DOSIMETRY↗

Correlation of Point B and Lymph Node Dose in 3D-Planned High-Dose-Rate Cervical Cancer Brachytherapy

Purpose: To compare high dose rate (HDR) point B to pelvic lymph node dose using three-dimensional-planned brachytherapy for cervical cancer. Methods and Materials: Patients with FIGO Stage IB-IIIB cervical cancer received 70 tandem HDR applications using CT-based treatment planning. The obturator, external, and internal iliac lymph nodes (LN) were contoured. Per fraction (PF) and combined fraction (CF) right (R), left (L), and bilateral (Bil) nodal doses were analyzed. Point B dose was compared with LN dose-volume histogram (DVH) parameters by paired t test and Pearson correlation coefficients. Results: Mean PF and CF doses to point B were R 1.40 Gy +- 0.14 (CF: 7 Gy), L 1.43 +- 0.15 (CF: 7.15 Gy), and Bil 1.41 +- 0.15 (CF: 7.05 Gy). The correlation coefficients between point B and the D100, D90, D50, D2cc, D1cc, and D0.1cc LN were all less than 0.7. Only the D2cc to the obturator and the D0.1cc to the external iliac nodes were not significantly different from the point B dose. Significant differences between R and L nodal DVHs were seen, likely related to tandem deviation from irregular tumor anatomy. Conclusions: With HDR brachytherapy for cervical cancer, per fraction nodal dose approximates a dose equivalent to teletherapy. Point B is a poor surrogate for dose to specific nodal groups. Three-dimensional defined nodal contours during brachytherapy provide a more accurate reflection of delivered dose and should be part of comprehensive planning of the total dose to the pelvic nodes, particularly when there is evidence of pathologic involvement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗