Engineering PapersSearch

SEARCH · Engineering Papers

Results for “interferometric”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

52 records · Page 3

Slow Quasiparticle Dynamics and Anyonic Statistics in a Fractional Quantum Hall Fabry-Pérot Interferometer

Anyons are two-dimensional particles with fractional exchange statistics that emerge as elementary excitations of fractional quantum Hall phases. Experimentally, their exchange statistics can be measured in the edge-state Fabry-Pérot interferometer, wherein the presence of 𝑁 𝑞⁢𝑝 localized anyons contributes a phase 𝑁 𝑞⁢𝑝⁢ 𝜃 𝑎 to the interference pattern where 𝜃 𝑎 is twice the exchange phase. Here we report the observation of large, hysteretic phase jumps in a monolayer graphene Fabry-Pérot interferometer at 𝜈 = 1/3. When the filling factor is increased from 𝜈 < 1/3 toward the center of the plateau, we observe phase slips with magnitude Δ⁢𝜃 ≈ 2⁢𝜋/3, consistent with the addition of individual quasiparticles to the interferometer bulk. These phase slips occur as instantaneous jumps in the interference signal, with intervals between the jumps indicating quasiparticle equilibration times exceeding 20 min. We use this long timescale to investigate the effect of changes in interferometer area 𝐴 𝐼 and 𝑁 𝑞⁢𝑝 independently at fixed magnetic field, revealing a striking memory effect in the phase slip magnitude. In particular, as the 𝜈 =1/3 plateau is approached from higher filling, we observed phase slips with Δ⁢𝜃 significantly larger than 2⁢𝜋/3 over the same range of gate voltage where quantized jumps are seen for increasing 𝜈. We discuss this asymmetry in terms of bulk-edge coupling of quasiparticles localized near the edge or in the bulk, and argue that this effect can be qualitatively reconciled with theoretical expectations for strongly interacting quasiparticles in the presence of weak disorder and strongly nonequilibrium charge dynamics. Besides providing a replication of interferometric measurements sensitive to 𝜃 𝑎 , our results highlight the key role played by charge dynamics on signatures of the anyon phase, and demonstrate that fractional quasiparticles can be indefinitely localized in nonequilibrium configurations.

anyons

Precision gyroscope from the helicity of light

We describe a gyroscope that measures rotation based on the effects of the rotation on the polarization of light. Rotation induces a differential phase shift in the propagation of left- and right-circularly polarized light and this phase shift can be measured in suitably designed interferometric setups. The signal in this setup is independent of the frequency of light, unlike various sources of noise such as vibrations, which cause phase shifts that depend on the frequency. Such vibrations are the practical limit on the sensitivity of conventional Sagnac-style optical interferometers that are typically used as gyroscopes. In the proposed setup, one can potentially mitigate this source of noise by simultaneously using two (or more) sources of light that have different frequencies. The signal in this setup scales with the total storage time of the light. Due to its frequency independence, it is thus most optimal to measure the signal using superconducting radio-frequency systems where the high finesse of the available cavities enables considerably longer storage times than is possible in an optical setup.

47 OTHER INSTRUMENTATION

Phase and contrast moiré signatures in two-dimensional cone beam interferometry

Neutron interferometry has played a distinctive role in fundamental science and characterization of materials. Moiré neutron interferometers are candidate next-generation instruments: they offer microscopy-like magnification of the signal, enabling direct camera recording of interference patterns across the full neutron wavelength spectrum. Here we demonstrate the extension of phase-grating moiré interferometry to two-dimensional geometries. Our fork-dislocation phase gratings reveal phase singularities in the moiré pattern, and we explore orthogonal moiré patterns with two-dimensional phase gratings. Our measurements of phase topologies and gravitationally induced phase shifts are in good agreement with theory. These techniques can be implemented in existing neutron instruments to advance interferometric analyses of emerging materials and precision measurements of fundamental constants. Published by the American Physical Society 2024

Sarenac, D. (ORCID:0000000185753367)

Photon-Counting Interferometry to Detect Geontropic Space-Time Fluctuations with GQuEST

The gravity from the quantum entanglement of space-time (GQuEST) experiment uses tabletop-scale Michelson laser interferometers to probe for fluctuations in space-time. We present a practicable interferometer design featuring a novel photon-counting readout method that provides unprecedented sensitivity, as it is not subject to the interferometric standard quantum limit. We evaluate the potential of this design to measure space-time fluctuations motivated by recent “geontropic” quantum gravity models. The accelerated accrual of Fisher information offered by the photon-counting readout enables GQuEST to detect the predicted quantum gravity phenomena within measurement times at least 100 times shorter than equivalent conventional interferometers. The GQuEST design, thus, enables a fast and sensitive search for signatures of quantum gravity in a laboratory-scale experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Topological shaping of vortex neutron beams using forked phase gratings

Beams of light or matter that carry well-defined states of orbital angular momentum (OAM) are promising probes of topological and textured condensed matter systems such as magnetic skyrmions. Using spin-echo small-angle neutron scattering, a phase-sensitive technique that allows for a relatively low intensity beam, we demonstrate the production of vortex neutron beams from forked phase gratings of various topological charges. This type of interferometric verification of OAM we present here could be further extended to other platforms using probes that are similarly limited by the coherence and strength of the currently available sources.

Cold atoms & matter waves

Solitons in Arbitrary Dimensions Stabilized by Photon-Mediated Interactions

We propose a scheme to generate solitons in arbitrary dimensions, in a matter-wave interferometer, without the need of quantum degeneracy. In our setting, solitons emerge by balancing the single-particle dispersion with engineered cavity-mediated exchange interactions between two wave packets, which, at the appropriate conditions, remain bound to each other and dispersion-free. For detection in thermal gases, we propose an interferometric probing scheme instead of traditional time-of-flight imaging.

cavity quantum electrodynamics

Zero-crosstalk silicon photonic refractive index sensor with subwavelength gratings

Abstract Silicon photonic index sensors have received significant attention for label-free bio and gas-sensing applications, offering cost-effective and scalable solutions. Here, we introduce an ultra-compact silicon photonic refractive index sensor that leverages zero-crosstalk singularity responses enabled by subwavelength gratings. The subwavelength gratings are precisely engineered to achieve an anisotropic perturbation-led zero-crosstalk, resulting in a single transmission dip singularity in the spectrum that is independent of device length. The sensor is optimized for the transverse magnetic mode operation, where the subwavelength gratings are arranged perpendicular to the propagation direction to support a leaky-like mode and maximize the evanescent field interaction with the analyte space. Experimental results demonstrate a high wavelength sensitivity of − 410 nm/RIU and an intensity sensitivity of 395 dB/RIU, with a compact device footprint of approximately 82.8 μm 2 . Distinct from other resonant and interferometric sensors, our approach provides an FSR-free single-dip spectral response on a small device footprint, overcoming common challenges faced by traditional sensors, such as signal/phase ambiguity, sensitivity fading, limited detection range, and the necessity for large device footprints. This makes our sensor ideal for simplified intensity interrogation. The proposed sensor holds promise for a range of on-chip refractive index sensing applications, from gas to biochemical detection, representing a significant step towards efficient and miniaturized photonic sensing solutions. Graphical Abstract

Materials Science

Spectral interferometry-based microwave-frequency vibrometry for integrated acoustic wave devices

Microwave phononics is a promising platform for sensing, computing, and quantum information science; thus, sensitive and high-throughput characterization tools are needed not only for device verification and optimization but also for revealing transient and nonlinear dynamics. Existing interferometric optical vibrometers for 2D mapping are challenged by operating point stabilization, surface reflectivity contrast, and long acquisition time. Here, we use spectral interferometry, which is insensitive to these factors and utilizes a continuous raster scanning scheme for vibration mapping with high throughput. We intensity-modulate our broadband light source with an electro-optic modulator to resolve vibrations at microwave frequencies. Our system requires no fast photodetector or digitizer operating in the microwave frequency range. We image the 1 GHz vibration field of a 300 × 150 µm 2 area of an entire surface acoustic wave device in 10 min with simultaneous surface profilometry. Our system has a vibration sensitivity of 120 fm/sqrt(Hz) and a linear throughput of 0.77 mm/s on the chip surface. The technique offers capabilities for characterizing a wide range of acoustic wave and micromechanical devices to better understand their behavior and performance.

47 OTHER INSTRUMENTATION

Designing a User Interface for Real-Time Magnetometer Data Acquisition

The Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) is a next-generation quantum sensor designed to search for ultralight dark matter and explore new frontiers in quantum mechanics. Due to the experiment s sensitivity to magnetic interference, a magnetometer trolley system was developed to scan magnetic fields along a vacuum tube. Interacting with the system required command-line inputs, creating usability challenges. To improve accessibility and streamline data acquisition, I developed a graphical user interface (GUI) using Python and the customtkinter library. The GUI supports real-time data display, state/mode switching, command execution, and CSV file management. I collaborated with another intern to integrate data visualization features into the GUI, allowing users to generate 3D plots of post-acquisition magnetic field data. In the future, I aim to fix the real-time plotting feature as it results in an unresponsive GUI.

Mendez, Milagros [DuPage Coll.]

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC

Determining Optimal Magnetometer Configuration on MAGIS-100

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.] (ORC

Designing a User Interface for Real-Time Magnetometer Data Acquisition

The Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) is a next-generation quantum sensor designed to search for ultralight dark matter and explore new frontiers in quantum mechanics. Due to the experiment’s sensitivity to magnetic interference, a magnetometer trolley system was developed to scan magnetic fields along a vacuum tube. Interacting with the system required command-line inputs, creating usability challenges. To improve accessibility and streamline data acquisition, I developed a graphical user interface (GUI) using Python and the customtkinter library. The GUI supports real-time data display, state/mode switching, command execution, and CSV file management. I collaborated with another intern to integrate data visualization features into the GUI, allowing users to generate 3D plots of post-acquisition magnetic field data. In the future, I aim to fix the real-time plotting feature as it results in an unresponsive GUI.

Mendez, Milagros [DuPage Coll.]

In-Situ Magnetic Field Reconstruction in the MAGIS-100 Experiment

Long-baseline atom interferometers such as the Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100) require stringent control and continuous characterization of background magnetic fields and spatial gradients to prevent systemic phase shifts that mimic ultralight dark matter or gravitational wave signatures. Because direct sensor placement within the ultra-high vacuum beam pipe is infeasible, in-situ magnetic field monitoring relies on external sensor arrays situated in the surrounding annular region. This work demonstrates a field reconstruction framework for a 5.3-meter MAGIS-100 modular section using finite-element Opera simulations. Transverse magnetic fields are expanded using a cylindrical multipole framework as informed by Fermilab’s Muon g-2 experiment, with magnetometer array configurations optimized via Fisher information matrix D-optimality. Inverting external sensor readings through a Gauss-Newton scheme recovers interior tube fields across distinct axial positions. In the discontinuity-averse uniform region (slice pair P4), the model achieves sub-noise-floor performance with a cross-validated root-mean-square error (RMSE) of $6.7227 \times 10^{-4}\text{ A/m}$ ($0.845\times$ sensor noise floor) and an interior field coefficient of variation of $1.71\%$. An elbow criterion in the Fisher bounds establishes $n_{\text{max}} = 2$ as the optimal multipole truncation order to prevent noise amplification from over-parameterization, with $n_{\text{max}} = 3$ (sextupole) order chosen for analysis to demonstrate further complexity and cross-pair comparison. Furthermore, analytical differentiation of the fitted multipole coefficients yields dense spatial maps of the transverse Jacobian gradient matrix $\nabla \mathbf{H}$ along with propagated $1\sigma$ uncertainty bounds across the beam region ($r \le 2.75\text{ in}$). This operational framework confirms that external magnetometer arrays can reliably monitor magnetic field uniformity and spatial gradients along the 100-meter flight path given appropriate sampling for any complexity order.

Appleby, Darwin [William Rainey Harper Coll.; Ferm

Optimising the processing and storage of visibilities using lossy compression

The next-generation radio astronomy instruments are providing a massive increase in sensitivity and coverage, largely through increasing the number of stations in the array and the frequency span sampled. The two primary problems encountered when processing the resultant avalanche of data are the need for abundant storage and the constraints imposed by I/O, as I/O bandwidths drop significantly on cold storage. An example of this is the data deluge expected from the SKA Telescopes of more than 60 PB per day, all to be stored on the buffer filesystem. While compressing the data is an obvious solution, the impacts on the final data products are hard to predict. In this paper, we chose an error-controlled compressor – MGARD – and applied it to simulated SKA-Mid and real pathfinder visibility data, in noise-free and noise-dominated regimes. As the data have an implicit error level in the system temperature, using an error bound in compression provides a natural metric for compression. MGARD ensures the compression incurred errors adhere to the user-prescribed tolerance. To measure the degradation of images reconstructed using the lossy compressed data, we proposed a list of diagnostic measures, exploring the trade-off between these error bounds and the corresponding compression ratios, as well as the impact on science quality derived from the lossy compressed data products through a series of experiments. We studied the global and local impacts on the output images for continuum and spectral line examples. We found relative error bounds of as much as 10%, which provide compression ratios of about 20, have a limited impact on the continuum imaging as the increased noise is less than the image RMS, whereas a 1% error bound (compression ratio of 8) introduces an increase in noise of about an order of magnitude less than the image RMS. For extremely sensitive observations and for very precious data, we would recommend a 0.1% error bound with compression ratios of about 4. These have noise impacts two orders of magnitude less than the image RMS levels. At these levels, the limits are due to instabilities in the deconvolution methods. We compared the results to the alternative compression tool DYSCO, in both the impacts on the images and in the relative flexibility. MGARD provides better compression for similar error bounds and has a host of potentially powerful additional features.

Techniques: interferometric

Spatially resolved polarization swings in the supermassive binary black hole candidate OJ 287 with first Event Horizon Telescope observations

We present the first Event Horizon Telescope 1.3 mm observations of the supermassive binary black hole candidate OJ 287. The observations achieved an unprecedented angular resolution of 18 μas and reveal significant structural and polarization variability over just five days, marking the shortest timescale on which such changes have been directly imaged in this source. The inner jet exhibits a twisted ridgeline structure, with features displaying apparent superluminal motions up to about 22 c. The linear polarization maps reveal three main polarized features whose electric-vector position angles (EVPAs) change substantially over the time span of our observations, including a component with a radial polarization consistent with being produced by a recollimation shock. Most notably, we directly resolved two innermost jet components whose EVPAs rotate in opposite directions. The faster component, moving at 2.4 ± 0.9 μas/day (17.4 ± 6.5 c), exhibits counterclockwise EVPA swings of roughly 3.7° per day, while the slower component, with a proper motion of 1.4 ± 0.3 μas/day (10.2 ± 2.2 c), rotates clockwise at approximately 2.5° per day. Previous studies inferred helical magnetic fields in AGN jets from time-resolved or integrated polarization variability but lacked the angular resolution to directly image this effect. Our results provide spatially resolved evidence that a helical magnetic field threads the jet’s collimation and acceleration zone, ruling out models based on the superposition of unresolved components. Our analysis suggests that propagating shocks interact with a Kelvin–Helmholtz plasma instability, illuminating different phases of the helical magnetic field and producing the observed polarization spatial and temporal variability. Moreover, our model naturally accounts for the more rapid polarization rotation observed in the faster moving component. Our model predicts even more rapid swings in polarization, which could be tested with future observations featuring a more densely sampled time coverage.

OJ 287

Full-polarization millimeter wavelength variability of Sagittarius A * during the 2018 EHT campaign

Context. Sagittarius A* (Sgr A*), the supermassive black hole at the center of the Milky Way, provides a unique laboratory to study accretion dynamics and plasma processes near the event horizon. Aims. We investigated the variability and polarization properties of Sgr A* using ALMA observations during the 2018 Event Horizon Telescope campaign. Methods. We analyzed high-cadence full-polarization light curves from ALMA at millimeter wavelengths, performed time-series analysis, and investigated the temporal behavior during an X-ray flare observed by Chandra on 2018 April 24. The variability characteristics are compared with expectations from standard accretion flow models. Results. We find low variability in total intensity (σ/μ < 10%), but significantly higher variability in linear and circular polarization (∼30% and ∼50%, respectively). A time-series analysis reveals red-noise variability, with power spectral densities between −2 and −3 across all Stokes parameters. Polarized intensity shows stable intra-day timescales, while total intensity exhibits more variable timescales, suggesting distinct emission regions, with polarization likely arising from a coherent structure. On April 24, a statistically significant inter-band delay in polarized intensity coincides with a near-simultaneous X-ray and millimeter peak that deviates from the typical delayed flare scenario. This event also features enhanced millimeter variability and coherent polarization loop evolution. The observed simultaneity challenges standard models of transient synchrotron emission with cooling delays, favoring instead a scenario of continuous energy injection in an optically thin region. Conclusions. Our results offer new constraints on the physical mechanisms driving variability in Sgr A*, and provide key observational input for refining theoretical models of accretion and plasma behavior in the vicinity of supermassive black holes.

Galaxy: center