Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interference-free”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

42 records · Page 3

Potassium Stable Isotopic Compositions Measured by High-Resolution MC-ICP-MS

Potassium isotopic (K-41/K-39) compositions are notoriously difficult to measure. TIMS measurements are hindered by variable fractionation patterns throughout individual runs and too few isotopes to apply an internal spike method for instrumental mass fractionation corrections. Internal fractionation corrections via the K-40/K-39 ratio can provide precise values but assume identical K-40/K-39 ratios (e.g. 0.05% (1sigma) in [1]); this is appropriate in some cases (e.g. identifying excess K-41) but not others (e.g., determining mass fractionation effects and metrologically traceable isotopic abundances). SIMS analyses have yielded measurements with 0.25% precisions (1sigma) [2]. ICP-MS analyses are significantly affected by interferences from molecular species such as Ar-38H(+) and Ar-40H(+) and instrument mass bias. Single collector ICP-MS instruments in "cold plasma" mode have yielded uncertainties as low as 2% (1sigma, e.g. [3]). Although these precisions may be acceptable for some concentration determinations, they do not resolve isotopic variation in terrestrial materials. Here we present data from a series of measurements made on the Thermo Scientific NEPTUNE Plus multi-collector ICP-MS that demonstrate the ability to make K-41/K-39 ratio measurements with 0.07% precisions (1sigma). These data, collected on NIST K standards, indicate the potential for MC-ICP-MS measurements to look for K isotopic variations at the sub-permil level. The NEPTUNE Plus can sufficiently resolve 39K and 41K from the interfering 38ArH+ and 40ArH+ peaks in wet cold plasma and high-resolution mode. Measurements were made on small but flat, interference-free, plateaus (ca. 50 ppm by mass width for K-41). Although ICP-MS does not yield accurate K-41/K-39 values due to significant instrumental mass fractionation (ca. 6%), this bias can be sufficiently stable over the time required for several measurements so that relative K-41/K-39 values can be precisely determined via sample-standard bracketing. As cold plasma conditions can amplify matrix effects, experiments were conducted to test the matrix tolerance of measurements; the use of clean, matrix-matched samples and standards is critical. Limitations of the cold-plasma high-resolution MC-ICP-MS methodology with respect to matrix tolerance are discussed and compared with the limitations of TIMS methodologies.

Morgan, Leah E.↗

Dry wind tunnel system

This invention is a ground flutter testing system without a wind tunnel, called Dry Wind Tunnel (DWT) System. The DWT system consists of a Ground Vibration Test (GVT) hardware system, a multiple input multiple output (MIMO) force controller software, and a real-time unsteady aerodynamic force generation software, that is developed from an aerodynamic reduced order model (ROM). The ground flutter test using the DWT System operates on a real structural model, therefore no scaled-down structural model, which is required by the conventional wind tunnel flutter test, is involved. Furthermore, the impact of the structural nonlinearities on the aeroelastic stability can be included automatically. Moreover, the aeroservoelastic characteristics of the aircraft can be easily measured by simply including the flight control system in-the-loop. In addition, the unsteady aerodynamics generated computationally is interference-free from the wind tunnel walls. Finally, the DWT System can be conveniently and inexpensively carried out as a post GVT test with the same hardware, only with some possible rearrangement of the shakers and the inclusion of additional sensors.

Chen, Ping-Chih↗

Use of the Ames Check Standard Model for the Validation of Wall Interference Corrections

The new check standard model of the NASA Ames 11-ft Transonic Wind Tunnel was chosen for a future validation of the facility's wall interference correction system. The chosen validation approach takes advantage of the fact that test conditions experienced by a large model in the slotted part of the tunnel's test section will change significantly if a subset of the slots is temporarily sealed. Therefore, the model's aerodynamic coefficients have to be recorded, corrected, and compared for two different test section configurations in order to perform the validation. Test section configurations with highly accurate Mach number and dynamic pressure calibrations were selected for the validation. First, the model is tested with all test section slots in open configuration while keeping the model's center of rotation on the tunnel centerline. In the next step, slots on the test section floor are sealed and the model is moved to a new center of rotation that is 33 inches below the tunnel centerline. Then, the original angle of attack sweeps are repeated. Afterwards, wall interference corrections are applied to both test data sets and response surface models of the resulting aerodynamic coefficients in interference-free flow are generated. Finally, the response surface models are used to predict the aerodynamic coefficients for a family of angles of attack while keeping dynamic pressure, Mach number, and Reynolds number constant. The validation is considered successful if the corrected aerodynamic coefficients obtained from the related response surface model pair show good agreement. Residual differences between the corrected coefficient sets will be analyzed as well because they are an indicator of the overall accuracy of the facility's wall interference correction process.

wind tunnel wall interferenc↗

Manufacturing and Scale-Up of Natural Fiber Composite eVTOL Propeller Skin and C-Channel

This report presents the manufacturing and scale-up of natural fiber composites for aerospace applications, conducted within NASA’s Convergent Aeronautics Solutions portfolio to advance aircraft capabilities and efficiency. The effort focused on the development and demonstration of two proof-of-concept articles, an Electric Vertical Take-off and Landing (eVTOL) propeller skin and a C-channel, produced through an iterative design and process optimization approach. Best practices and guidance on addressing key challenges with bio-based composite materials and manufacturing is provided. Ideally suited for non-load-bearing structural components, these emerging materials offer potential for weight reduction, vibration damping, noise mitigation, interference-free communication, and cost savings, without compromising the performance of safety-critical primary structures.

Natural fibers↗

Preliminary Assessment of the Impact on the V-Band Oxygen Channels From Satellite Communication Uplinks

We calculate the percentage of time that an ATMS-like instrument [1] will be illuminated by the uplink beam of one of the proposed V-band communication system and estimate the damage resulting from such exposure. Using a combination of openly available information and educated guesses about the location and characteristics of the up/down link terminals, we constructed the ground segment of a hypothetical high-speed communication network. The space segment of the network was constructed from the orbital data of the existing Starlink constellation [2] of 6223 communication satellites (comsats) which is used as strawman to represent any other possible constellation of communication satellites. It is shown that without a very delicate balance of frequency allocations (science vs telecommunications), coupled with extremely steep and deep bandpass-defining filters, and strict adherence to the agreed limits (i.e. no out-of-band transmissions) the deployment of the telecommunication network leads to almost-complete loss of some important geophysical data. For the analysis we use the spectral characteristics of the ATMS instrument with the ephemeris for the NOAA-21 satellite [3]. The analysis is conducted for the USA and the simulation covers 8 consecutive days in July 2024. Effective and accurate microwave remote sensing of the atmosphere depends on the availability of interference-free spectrum windows at frequencies which are prescribed by physical processes [e.g. 4]. The family of resonant lines of the oxygen molecule near 60 GHz provides a unique opportunity to sample the vertical distribution of temperature and density from space, and it has been exploited for weather and climate studies from polar-orbiting satellites since 1978 (MSU on TIROS-N [5]). It remains a staple in the payloads operated by Russia, China, USA, Japan, France, India, UK, Ukraine [6] which are built around a common blueprint: a few wide-band (hundreds of MHz) channels around 50 GHz to sample the atmosphere and the surface while several more channels with high spectral resolution (few MHz) sample the individual resonant lines. Accurate retrieval of the environmental parameters depends upon the data provided by both sets of channels, and the their location in frequency space is not arbitrary and cannot be altered at will [7, 8]. The introduction of 5G technology in 2019 has driven telecommunication companies to request more bandwidth to be dedicated to their devices. This additional bandwidth is only available in spectral regions traditionally reserved for environmental and astrophysical research, such as the V-band between 50 and 60 GHz for up/downlink between satellites in low-earth orbits and terminals connected to fiberoptics network for distribution to high-speed local internet services. The power broadcast by the uplink communication leg is many orders of magnitude greater than the natural thermal signal emitted from the Earth scene. If the ground antenna were to perfectly align with the passive instrument’s antenna, the spaceborne receiver would suffer permanent, irreparable damage. While a direct boresight-to-boresight conjunction is extremely unlikely (even with a large constellation of satellites the fraction of the celestial sphere occupied by the satellites remains minuscule) the finite size of the ground station’s antenna beam in the sky suggests that the ATMS will be in the near background (as seen from the ground station) of one of the communication satellites and will be illuminated by either the main lobe or the near sidelobes of the uplink antenna more often than it is desirable. For our analysis we first calculate the position of the ATMS with respect to each of the ground stations at a resolution of 0.2 sec, then calculate the position of each of the comsats which are at least 25 deg above the station’s local horizon; finally we calculate the angle between the line-of-sight of the ATMS and the line-of-sight of the comsat. We assume that the gain pattern of the ground station is circularly symmetric; the angle-off-station-boresight then provides an attenuation of the uplink power which we use to assess the likely effect upon the passive instrument’s operations. We assume that each ground station can communicate with all the comsats in its field of view; this implies that, on average, a ground station can engage with 46 comsats simultaneously. The analysis is repeated for the case when the uplink broadcast within the ATMS passive channels (in-band scenario) and for the case when the uplink is limited to frequencies adjacent to the ATMS channels (out-of-band scenario). The antenna of the ground station is modelled as having a HPBW (Half-Power Beam Width) of 0.16 deg and EIRP (Equivalent Isotropic Radiated Power) of 70 dBW. We account for the geometric dissipation of the signal caused by the satellite orbital altitude, the attenuation induced by atmospheric gasses at 51 GHz and the mismatch between the circular polarization of the ground-based transmitting antenna and the linear polarization of the satellite-borne receiving antenna. The damages on ATMS are estimated from bench-level measurement conducted at the ATMS’ manufacturer facilities [unpublished].

passive microwave↗

TMTpro Complementary Ion Quantification Increases Plexing and Sensitivity for Accurate Multiplexed Proteomics at the MS2 Level

Multiplexed proteomics is a powerful tool to assay cell states in health and disease, but accurate quantification of relative protein changes is impaired by interference from co-isolated peptides. Most widely, this issue is alleviated by MS3-based quantification, reducing sensitivity and requiring specialized instrumentation. An alternative approach is quantification by complementary ions, which allows accurate and precise multiplexed quantification at the MS2 level and is compatible with the most widely distributed instruments. However, complementary ions of the popular TMT tag form inefficiently and plexing is limited to five channels. In this work, we evaluate and optimize complementary ion quantification for the recently released TMTPro tag, which increases plexing capacity to 8 channels (TMTProC). We find that the beneficial fragmentation properties increase quantification signal five-fold compared to TMT. This increased sensitivity results in ~50% more proteins quantified compared to TMTPro-MS3 and even slightly outperforms TMTPro-MS2. Furthermore, TMTProC quantification is more accurate than TMTPro-MS2 and even superior to TMTPro-MS3. To demonstrate the power of TMTProC, we analyzed a human and yeast interference sample and were able to quantify 13,290 proteins in 24 fractions. Thus, TMTProC advances multiplexed proteomics data quality and widens access to accurate multiplexed proteomics beyond laboratories with MS3-capable instrumentation.

59 BASIC BIOLOGICAL SCIENCES↗