Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interconnections”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Working With Your Utility Series: Interconnection Basics

This training provided information on interconnection basics for federal agencies developing distributed energy projects. Considerations covered included: Understanding interconnection processes and timelines, interconnection siting considerations, technology-specific interconnection issues, and interconnect agreements. This webinar is the first in a multi-part series on working with electric utilities to develop distributed energy projects on federal sites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Temperature RF Transmission Loss Characteristics of Platinum–Inconel 600 and Platinum–304 Steel Interconnects

Radio frequency (RF) transmission losses that occur at electronic interconnects is currently an important limitation of wireless sensors and other electronic device packages that must operate in high-temperature environments. Herein, in-situ RF transmission losses were measured for two types of interconnects: platinum (Pt) wire bonded to an Inconel 600 coaxial cable; and Pt-wire bonded to a block of 304 steel. Heating the Pt wire/Inconel interconnects at 800 °C for up to 200 hours were found to be very stable with no measurable transmission losses. In contrast, Pt wire/304 steel block interconnects examined over similar test periods at 800 °C exhibited gradual increases in transmission losses leveling off at 10, 38 and 85 mdB at 400 MHz, 700 MHz, and 1 GHz, respectively. Increasing the test temperature to 900 °C caused further elevated transmission losses of 30, 70 and 108 mdB at the same reported frequencies. By comparison, temperature cycling of the Pt wire/304 steel interconnects between room temperature and 900 °C was found to cause more significant degradation. In particular, four thermal cycles from room temperature to 900 °C resulted in losses of 75, 271, and 482 mdB at the same reported frequencies. Parabolic oxidation relative to the RF skin depth in the 304 steel block at the tested frequencies are discussed as possible reasons for the transmission losses during the isothermal soaks, whereas interconnect degradation due to differences in thermal expansion between Pt and 304 steel are primarily responsible for transmission losses caused by high temperature cycling.

304 steel↗

Graphene-Based Interconnect Exploration for Large SRAM Caches for Ultrascaled Technology Nodes

Graphene-based interconnects are considered promising replacements for traditional copper (Cu) interconnect due to their great electric properties. In this article, an interconnect-memory co- design framework is developed to efficiently optimize various graphene-based interconnect technologies. Four interconnect materials and heterogeneous design schemes are benchmarked against their traditional Cu counterparts to optimize large cache-level SRAM performance in terms of delay and energy per access, energy-delay product (EDP), and energy-delay-area product (EDAP). Here, a large design space exploration is performed based on realistic subarray design and device technology. Various interconnect- and array-level design parameters are studied to quantify the true potential of graphene-based wires for optimal memory performance.

42 ENGINEERING↗

Characterization of Interconnects

Combined-accelerated stress testing (C-AST) simultaneously combines stress factors of the natural environment (including UV radiation, temperature, humidity, electrical current, and external mechanical force) into a single test that requires fewer modules, fewer chambers, and makes it possible to discover weaknesses in new designs that are not known a-priori. C-AST reduces risk, accelerates time to market, and improves bankability by reducing costly overdesign using test levels not exceeding those seen in the natural environment. This project seeks to evaluate strengths and weaknesses of modern cell interconnect designs with combined-accelerated stress testing (C-AST) to screen multiple climates along with finite element and failure analysis to determine the potential for a 50-year life. Supporting this, we seek to develop methods of characterization to assess the degradation of interconnects, enable predictive rate models with material forensics and FEA and show C-AST's ability to find interconnect failures and benchmark it relative to other accelerated stress test methods like temperature cycling and cyclic dynamic mechanical loading. Examples of modern interconnect designs covered are Canadian Solar Hetero Technology ribbon enabling closer cell interconnections, SmartWire (eg. Meyer-Berger technology), and shingled cells with new interconnect materials.

C-AST↗

Optimal interconnection of three-terminal tandem solar cells

Three-terminal (3T) tandem solar cells require an adapted module integration scheme in order to explore their full efficiency potential. The three terminals allow to extract the power of the top and bottom cell separately. In a cell string, the wide bandgap top cells are interconnected in parallel to multiple bottom cells resulting in a parallel/series interconnection. This interconnection scheme affects the operation of the subcells, the resulting current path between the subcells, the layout of the cell interconnects, and the system level. Here, we analyze by simulations and experiments the aspects of the module integration of series- and reverse-connected 3T cells with their practical impact on module processes and performance as well as the effect of varying voltage ratios on the string-end losses. If the subcells are connected in series, the module integration requires insulation layers and significantly longer interconnects compared to devices with reverse-connected subcells. Tandem devices with a reverse connection and a voltage ratio between top and bottom cell of 2:1 allow a lean interconnection design and low integration losses. Here, we present an approach for the integration of bypass diodes for the protection against shading effects that allow to minimize string-end and shading losses for a system of modules featuring 3T cells.

14 SOLAR ENERGY↗

Interconnected Nanoporous Polysulfone by the Self-Assembly of Randomly Linked Copolymer Networks and Linear Multiblocks

Porous materials have attracted considerable attention due to their versatile applications, especially in water purification. Interconnected nanoporous structures are distinguished by their high degree of porosity and resistance to clogging, as well as their insensitivity to nanostructural orientation. Previous works on randomly linked copolymer systems have shown that they can effectively produce disordered cocontinuous nanostructures, which upon removal of one component yield interconnected nanoporous materials. However, the cocontinuous nanomaterials previously developed using polystyrene (PS) and poly(d,l-lactic acid) (PLA) strands, and the resulting interconnected nanoporous PS monoliths, were far too brittle to enable practical use as membranes. Here, we study the self-assembly of randomly linked copolymer networks prepared using blocks of the engineering polymer polysulfone (PSU). A wide cocontinuous regime (spanning 40 wt %) was found for randomly end-linked copolymer networks (RECNs) constructed from PSU and PLA strands, via a combination of mechanical testing, gravimetry, small-angle X-ray scattering, and scanning electron microscopy. The PSU/PLA cocontinuous nanomaterial with symmetric composition showed 2.4 times higher Young’s modulus and ~100 times greater toughness than the corresponding PS/PLA sample. The interconnected nanoporous PSU fabricated after etching of PLA even exhibited 1.6 times greater toughness than PS/PLA prior to PLA removal. To facilitate the production of thin films of cocontinuous nanomaterials, we applied solution-processable randomly linked linear PSU/PLA multiblock polymers onto ultrafiltration membranes. Here, the interconnected nanoporous PSU thin film generated by etching PLA was found to effectively reject 50 nm diameter particles without significantly compromising permeability. This discovery presents a valuable addition to the existing techniques used to fabricate PSU membranes. In contrast to traditional methods, which are sensitive to processing conditions, produce a wide range of pore sizes, and offer limited adjustability of pore size, the current technique is anticipated to enable interconnected PSU membranes with more uniform and tailorable porosity.

36 MATERIALS SCIENCE↗

Development of Quantum Interconnects (QuICs) for Next-Generation Information Technologies

Just as “classical” information technology rests on a foundation built of interconnected information-processing systems, quantum information technology (QIT) must do the same. A critical component of such systems is the “interconnect,” a device or process that allows transfer of information between disparate physical media, for example, semiconductor electronics, individual atoms, light pulses in optical fiber, or microwave fields. While interconnects have been well engineered for decades in the realm of classical information technology, quantum interconnects (QuICs) present special challenges, as they must allow the transfer of fragile quantum states between different physical parts or degrees of freedom of the system. The diversity of QIT platforms (superconducting, atomic, solid-state color center, optical, etc.) that will form a “quantum internet” poses additional challenges. As quantum systems scale to larger size, the quantum interconnect bottleneck is imminent, and is emerging as a grand challenge for QIT. For these reasons, it is the position of the community represented by participants of the NSF workshop on “Quantum Interconnects” that accelerating QuIC research is crucial for sustained development of a national quantum science and technology program. Given the diversity of QIT platforms, materials used, applications, and infrastructure required, a convergent research program including partnership between academia, industry, and national laboratories is required.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Considerations for Distributed Energy Resource Integration in Puerto Rico: DOE Multi-Lab Grid Modeling Support for Puerto Rico; Analytical Support for Interconnection and IEEE Std 1547-2018 National Renewable Energy Laboratory (Task 3.0)

To ensure the sustainable long-term recovery of Puerto Rico's electric power grid from hurricanes María and Irma and to build capacity to manage future potential natural disasters in the most secure and resilient way, the U.S. Department of Energy (DOE) convened experts from multiple national laboratories to develop a comprehensive set of data, models, analytic tools, and studies, considering inputs from a wide variety of stakeholder groups, to support technically sound recommendations for Puerto Rico's energy investment decisions. A resilient electric grid is vital to Puerto Rico's security, economy, and way of life, and it will provide the foundation for essential services that people and businesses on the island rely on every day. This report shows progress for a grid modeling task under the DOE-sponsored project that is a collaboration among the National Renewable Energy Laboratory (NREL) and other national laboratories. In Phase 1 of the multilab effort to support Puerto Rico's recovery, NREL provided the utility company Puerto Rico Electric Power Authority (PREPA) recommendations for a new framework of interconnection standards to accelerate the integration of utility-scale, transmission-connected renewable electrical generation and energy storage that ensure cross-technology compatibility and enable high deployment levels without compromising grid reliably, safety, or security. This Phase 2 report focuses on the interconnection of distributed energy resources (DERs) to the electric distribution system in Puerto Rico. This report is intended to familiarize the reader with Puerto Rico's distribution infrastructure and operational practices and procedures that are relevant to DER interconnection. The report also provides considerations for streamlining the interconnection process given the expected increase in deployments resulting from Puerto Rico's renewable portfolio standard (RPS) goal of 100% renewables by 2050. Accordingly, the report identifies considerations and concerns associated with the increase in intermittent generation, strategies for DER interconnection best practices, and the potential use of the latest technological solutions identified in the latest revision of the Institute of Electrical and Electronics Engineers (IEEE) 1547-2018 interconnection standard.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Queued Up: Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2022 [Slides]

Proposed large-scale electric generation and storage projects must apply for interconnection to the bulk power system via interconnection queues. While most projects that apply for interconnection are not subsequently built, data from these queues nonetheless provide a general indicator for mid-term trends in developer interest. Berkeley Lab compiled and analyzed data from all seven ISOs/RTOs in concert with 35 non-ISO utilities, representing an estimated 85% of all U.S. electricity load. We include all "active" projects in these generation interconnection queues through the end of 2022, as well as data on "operational" and "withdrawn" projects where those data are available. We find that the amount of new electric capacity in these queues is growing dramatically, with over 2,000 gigawatts (GW) of total generation and storage capacity now seeking connection to the grid (over 95% of which is for zero-carbon resources like solar, wind, and battery storage). Solar (947 GW) and battery storage (~680 GW) are – by far – the fastest growing resources in the queues; combined they accounted for over 80% of new capacity entering the queues in 2022. Substantial wind (300 GW) capacity is also seeking interconnection, 38% of which is for offshore projects (113 GW). In total, about 1,250 GW of zero-carbon generating capacity is currently seeking transmission access, as is 82 GW of natural gas capacity. Hybrids projects (co-locating multiple generation and/or storage types) comprise a large – and increasing – share of proposed projects, particularly in CAISO and the non-ISO West. 457 GW of solar hybrids (primarily solar+battery) and 24 GW of wind hybrids are currently active in the queues; over half of battery storage in the queues is paired with generation. However, much of this proposed capacity will be withdrawn from the queues and not built. Among a subset of queues for which data are available, only 21% of the projects (and 14% of capacity) seeking connection from 2000 to 2017 have been built as of the end of 2022. Additionally, interconnection wait times are on the rise: The typical duration from connection request to commercial operation increased from <2 years for projects built in 2000-2007 to nearly 4 years for those built in 2018-2022 (with a median of 5 years for projects built in 2022).

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-voltage push to mate electrical interconnect

A high-voltage self-aligning push to mate electrical interconnect device is provided. The electrical interconnect device includes a housing with a mating end and a receiving end. The interconnect also includes an insulator bushing configured to be affixed to the receiving end of the housing. The interconnect also includes a center pin disposed within the housing. The center pin extends from the mating end of the housing to the receiving end of the housing. The interconnect also includes a connector socket disposed within the insulator bushing and which is in electrical communication with the center pin. The interconnect also includes an alignment sleeve including a chamfered mating funnel defining a void configured to accept and surround the housing and at least a portion of insulator bushing.

Martinez, David K.↗

Supervised Learning for Distribution Secondary Systems Modeling: Improving Solar Interconnection Processes

The current interconnection process and hosting capacity analysis for distributed energy resources (DERs), such as photovoltaics (PV) and battery energy storage systems, are based on analyzing grid network constraints (voltage and thermal) using only medium-voltage distribution network models. This is because most utilities do not have secondary low-voltage system models that connect service transformers and residential customers. This is important because in many cases the main impact of interconnecting DERs could occur on the low-voltage distribution systems. This paper proposes a supervised learning method to approximate local secondary models to improve the interconnection process. The proposed supervised learning method includes a decision tree model that predicts the secondary topology and a logistic regression model that predicts conductor types. The case studies demonstrate the benefits of including secondary low-voltage circuits in the interconnection process. We report the proposed modeling methodology is readily scalable and thus can reduce the cost and effort of PV interconnection for the industry and stakeholders.

14 SOLAR ENERGY↗

Nanometal-Interconnected Carbon Conductors (NICCS) for Advanced Electric Machines (RIT Final Technical Report)

Recent advancements in carbon nanotube (CNT) research have enabled lightweight, conductive wires as a transformative technology. Metal-carbon nanotube (CNT) hybrid conductors aim to combine the high conductivity of traditional metals with the low mass and temperature coefficient of resistance (TCR) of carbon nanotubes. The high conductivity of copper makes it a promising candidate to combine with CNTs in a hybrid structure, but there is limited physical and electrical interaction between copper and CNTs. The use of an interfacial layer offers one method of improving the interconnection of a Cu-CNT hybrid conductor. Over the course of this grant, a joule heating-driven chemical vapor deposition (CVD) technique was developed to deposit nanometal seeds throughout a porous, low-density (0.12 g/cm 3 , ~10 tex or mg/m) CNT roving template. Modification of the applied current to the CNT roving allows for the tuning of depositions towards either hot-spot site-specificity or overall uniformity. The effects of temperature, pressure, precursor mass, and the interval of applied current were investigated, demonstrating nanometal depositions ranging from less than 5 % w/w to over 85 % w/w. The versatility of CVD allows for a wide variety of metals to be deposited including copper, titanium, nickel, silver, tungsten, palladium, platinum, ruthenium, rhodium, and iridium. One preferred demonstration involved using platinum depositions to improve the electrical properties of metal-seeded CNTs across all mass loadings studied. Moreover, when the metal-seeded CNT wires were electroplated with copper, densified, and annealed under hydrogen/argon; the result was a Cu-CNT hybrid conductor with the highest conductivities reported to date. The good interconnection of the metal and CNT portions results in a stable conductor. An electrical conductivity of 16-20 MS/m was achieved for multiple Cu-CNT hybrid conductors at 150 °C, which exceeds the program goal for conductivity of greater than 15 MS/m for a 1 m long CNT wire. Overall, the research outcomes from the project showed improvements in CNT wire fabrication from roll-to-roll CVD grown carbon nanotube wires using nanometal interconnects to bridge CNT-to-CNT junctions, thus mitigating network contact resistances. Advanced nanometal interconnected carbon conductors (NICCs) were developed as a means to achieve novel light-weight wiring appropriate for applications that require the conductivity of metallic (i.e., Cu, Al, etc.) wires at elevated temperatures. High conductivity, low TCR electrical conductors such as the nanometal interconnected Cu-CNT hybrids have numerous future applications towards high efficiency motors, generators, and transformers. Specifically, the advanced wires have the ability to operate at lower resistance during conditions for standard electric motors at 150 °C, which would improve the electrical efficiency while lowering energy needs.

36 MATERIALS SCIENCE↗

Multi‐Objective Optimization for Rapid Identification of Novel Compound Metals for Interconnect Applications

Abstract Interconnect materials play the critical role of routing energy and information in integrated circuits. However, established bulk conductors, such as copper, perform poorly when scaled down beyond 10 nm, limiting the scalability of logic devices. Here, a multi‐objective search is developed, combined with first‐principles calculations, to rapidly screen over 15,000 materials and discover new interconnect candidates. This approach simultaneously optimizes the bulk electronic conductivity, surface scattering time, and chemical stability using physically motivated surrogate properties accessible from materials databases. Promising local interconnects are identified that have the potential to outperform ruthenium, the current state‐of‐the‐art post‐Cu material, and also semi‐global interconnects with potentially large skin depths at the GHz operation frequency. The approach is validated on one of the identified candidates, CoPt, using both ab initio and experimental transport studies, showcasing its potential to supplant Ru and Cu for future local interconnects.

Chemistry↗

Queued Up: Characteristics of Power Plants Seeking Transmission Interconnection As of the End of 2021 [Slides]

Proposed large-scale electric generation and storage projects must apply for interconnection to the bulk power system via interconnection queues. While most projects that apply for interconnection are not subsequently built, data from these queues nonetheless provide a general indicator for mid-term trends in developer interest. Berkeley Lab compiled and analyzed data from all seven ISOs/RTOs in concert with 35 non-ISO utilities, representing an estimated 85% of all U.S. electricity load. We include all "active" projects in these generation interconnection queues through the end of 2021, as well as data on "operational" and "withdrawn" projects where those data are available. We find that the amount of new electric capacity in these queues is growing dramatically, with over 1,400 gigawatts (GW) of total generation and storage capacity now seeking connection to the grid (over 90% of which is for zero-carbon resources like solar, wind, and battery storage). Solar (676 GW) and battery storage (~420 GW) are – by far – the fastest growing resources in the queues; combined they accounted for nearly 85% of new capacity entering the queues in 2021. Substantial wind (247 GW) capacity is also seeking interconnection, 31% of which is for offshore projects (77 GW). In total, about 930 GW of zero-carbon generating capacity is currently seeking transmission access, as is 74 GW of natural gas capacity. Hybrids now comprise a large – and increasing – share of proposed projects, particularly in CAISO and the non-ISO West. 286 GW of solar hybrids (primarily solar+battery) and 19 GW of wind hybrids are currently active in the queues; nearly half of battery storage in the queues is paired with generation. However, much of this proposed capacity will be withdrawn from the queues and not built. Among a subset of queues for which data are available, only 23% of the projects seeking connection from 2000 to 2016 have subsequently been built. Completion percentages appear to be declining and are even lower for wind and solar than other resources. Additionally, wait times are on the rise: for the regions with available data, the typical duration from connection request to commercial operation increased from ~2.1 years for projects built in 2000-2010 to ~3.7 years for those built in 2011-2021.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fine Pitch Bonding for High Density Interconnects

CTE (coefficient of thermal expansion) mismatch between two wafers has potential for brittle failure when large areas are bonded on top of one another (wafer to wafer or wafer to die bonds). To address this type of failure, we proposed patterning a polymer around metallic interconnects. For this project, utilized benzo cyclobutene (BCB) to form the bond and accommodate stress. For the metal interconnects, we used indium. To determine the benefits of utilizing BCB, mechanical shear testing of die bonding with just BCB were compared to die bonded just with oxide. These tests demonstrated that BCB, when cured for only 30 minutes and bonded at 200°C, the BCB was able to withstand shear forces similar to oxide. Furthermore, when the BCB did fail, it experienced a more ductile failure, allowing the silicon to crack, rather than shatter. To demonstrate the feasibility of using BCB between indium interconnects, wafers were pattered with layers of BCB with vias for indium or ENEPIG (electroless nickel, electroless palladium, immersion gold). Subsequently, these wafers were pattered with a variety of indium or ENEPIG interconnect pitches, diameters, and heights. These dies were bonded under a variety of conditions, and those that held a bond, were cross-sectioned and imaged. Images revealed that certain bonding conditions allow for interconnects and BCB to achieve a void-less bond and thus demonstrate that utilizing polymers in place of oxide is a feasible way to reduce CTE stress.

36 MATERIALS SCIENCE↗

Radio frequency tuning using a multichip module electrical interconnect structure

A method for tuning a resonant frequency of wireless communication circuitry on a multichip module including a plurality of chips includes applying an electrical insulator to an upper surface of the multichip module; creating a plurality of openings in the electrical insulator, each opening being positioned at a successive one of the bond pads to be electrically connected to create a plurality of exposed bond pads; applying metal to each exposed bond pad to form a successive one of a plurality of interconnect bases; removing a portion of the layer of photoresist to create a plurality of bridge supports, each bridge support positioned between a successive pair of interconnect bases; applying metal to each bridge support and associated interconnect bases to form a successive one of the interconnect traces; removing the bridge supports; and disconnecting one or more of the interconnect traces as necessary to obtain a target resonant frequency.

Young, Barbara Diane↗

Communication engine for hybrid interconnect technologies

Systems, apparatuses, and methods for dynamically selecting between wired and wireless interconnects for sending packets are disclosed. A system includes at least a hybrid communication engine and a plurality of interconnects for connecting to various end-points. The communication engine dynamically discovers and utilizes the best interconnect technology available in between given end-points. The communication engine dynamically chooses the physical interconnect that is best suited at any given time to send data from one source to one or multiple destinations. This communication can be either on-chip or across nodes. The communication engine makes a decision based on a set of predetermined parameters that can be re-adjusted by the application layer, such as latency of the transmission, message data size, physical distance from source to destination, the energy cost, and the current congestion on the alternative interconnects.

Blagodurov, Sergey↗

Defining Safe and Efficient Interconnection Policies for Energy Storage and Solar + Storage to Improve Integration and Reduce Costs

Energy storage has a unique and pivotal role to play in the transition to a low-carbon economy because it can help the electric grid accommodate more renewable energy. However, a number of barriers currently impede the process of connecting energy storage systems to the distribution grid. The Toolkit and Guidance for the Interconnection of Energy Storage and Solar-Plus-Storage (the “BATRIES Toolkit”), which is the publication subject to this Final Technical / Scientific Report, provides vetted solutions to eight regulatory and technical barriers to the interconnection of standalone storage and solar-plus-storage systems (referred to as “energy storage”) to the distribution grid. These recommendations are based on over a year of research and analysis by utility and industry experts. The BATRIES Toolkit also includes model language that utilities and utility regulators can use to update state interconnection rules to reduce the costs and time to safely interconnect energy storage and solar-plus-storage systems. The solutions are nationally applicable and can be applied in diverse states and markets across the U.S.

14 SOLAR ENERGY↗