Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “integrated controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Enabling integrated AI control on DIII-D: a control system design with state-of-the-art experiments

We present the design and application of a general algorithm for Prediction And Control using MAchiNe learning (PACMAN) in DIII-D. Machine learning (ML)-based predictors and controllers have shown great promise in achieving regimes in which traditional controllers fail, such as tearing mode (TM) free scenarios, ELM-free scenarios and stable advanced tokamak conditions. The architecture presented here was deployed on DIII-D to facilitate the end-to-end implementation of advanced control experiments, from diagnostic processing to final actuation commands. This paper describes the detailed design of the algorithm and explains the motivation behind each design point. We also describe several successful ML control experiments in DIII-D using this algorithm, including a reinforcement learning controller targeting advanced non-inductive plasmas, a wide-pedestal quiescent H-mode ELM predictor, an Alfvén Eigenmode controller, a Model Predictive Control plasma profile controller and a state-machine TM predictor-controller. There is also discussion on guiding principles for real-time ML controller design and implementation.

machine learning↗

Modular Wide-bandgap String Inverters for Low-cost Medium-voltage Transformerless PV Systems

The proposed technology combines advances in wide-bandgap power electronics with breakthroughs in distributed and decentralized control to produce ultra-low-cost medium-voltage transformerless PV inverters that are composed of stackable lightweight blocks. Taken together, the proposed circuit designs and accompanying control strategies will yield integrated control+circuit (C2) blocks, each comprising a converter and local controller, that can be assembled in a modular fashion to obtain distributed conversion interfaces for next-generation commercial and utility-scale PV systems. We will utilize SiC devices to obtain C2 blocks that can individually operate at a voltage and power in excess of 1 kV and 100 kW, respectively, such that ensembles of series-connected blocks perform direct dc to three-phase ac conversion at medium voltages (e.g., 12 kV–35 kV) and at multi-MW power levels.

42 ENGINEERING↗

Estimation of the time for steam generator trip due to cyber intrusions

The time required to trip a pressurized water reactor (PWR) by inserting malicious signals into its steam generator (SG) control system has been studied using the Generic PWR (GPWR) Simulator. A semi-analytical model is developed to approximately reproduce the simulator response and understand the dynamics of the control unit. A series of two proportional-integral controllers determines control action according to preset constants, the readings from the feedwater level sensor, and those from feedwater and steam flowrate transmitters. It is observed that the most important factor that determines whether a trip will occur is how much additional water is added to or withheld from the SG over time compared to normal operating conditions. In order to determine the effects of control action on the SG, changes in mass inventory are considered. This approach models the SG water level as a function of mass inventory and has a backward temporal memory. A Python interface is developed for the GPWR framework to automatically simulate different spoofing scenarios and post-process the related data. We observe that the trip times predominantly depend on flow mismatch and/or level errors. Controller parameters, including the integral time and gain constants, either speed up or slow down the rate of progression to a trip setpoint but do not cause a trip by themselves. The reactor can trip on a high-level signal when the reading crosses above 78%, increased from its reference level of 57%, or a low-level reading when it is below 25%. The present results show roughly how long the operators would have to respond to an attack, given a specific set of spoofing signals within the issue space analyzed. Furthermore, we have generated a simple surface by fitting a combination of exponential functions to the data obtained from the GPWR Simulator. In general, trips on a low level have been observed to occur faster than those on a high level.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Binary optimal control by trust-region steepest descent

Abstract We present a trust-region steepest descent method for dynamic optimal control problems with binary-valued integrable control functions. Our method interprets the control function as an indicator function of a measurable set and makes set-valued adjustments derived from the sublevel sets of a topological gradient function. By combining this type of update with a trust-region framework, we are able to show by theoretical argument that our method achieves asymptotic stationarity despite possible discretization errors and truncation errors during step determination. To demonstrate the practical applicability of our method, we solve two optimal control problems constrained by ordinary and partial differential equations, respectively, and one topological optimization problem.

97 MATHEMATICS AND COMPUTING↗

A Cost-Effective Wave Energy Harvesting System with Maximum Power Point Tracking Capability

In this paper, we propose a low-cost bidirectional four-switch inverter that transfers three-phase energy between a permanent magnet synchronous generator (PMSG) driven by a wave energy collector and the power grid or a local ac load. To achieve high control performance, the machine-side inverter uses a high-gain observer for rotor position estimation and a Lyapunov-based approach for torque control. For the gridside inverter control, we estimate the filter capacitor voltage with a model reference adaptive system and control the dc-link voltage with a Lyapunov-based energy function. We also track the maximum power point from the sea waves with an integral control law that actively matches the generator impedance with that of the wave collection device. The proposed system supports both grid-following/forming modes. We validate our control design with simulation results on a 3-kW hardware setup.

wave energy, power systems integration, control de↗

Small-Signal Stability of Grid-Forming Inverters Using Current-Limiting and Frequency Stabilization

This paper presents a small-signal stability analysis of grid-forming (GFM) inverters under current-limiting conditions. It examines how adjustments in virtual impedance angles, implemented through advanced current-limiting and frequency stabilization techniques, influence small-signal stability. This paper studies a GFM inverter control integrating a fictitious power technique stabilizing primary control by adding a virtual power term and a hybrid current limiter integrating virtual impedance in the anti-wind-up feedback with current reference saturation limiting. A small-signal model is developed to assess the impact of virtual impedance angles on GFM inverter dynamics during grid disturbances, such as voltage drops. The findings indicate that although increasing the virtual impedance angle (to make it more inductive) enhances large-signal stability and voltage support during faults, it can induce oscillations and lead to instability if the angle exceeds certain thresholds. Based on the small-signal models, this paper provides design considerations for the current-limiter impedances to ensure reliable GFM inverter behavior under grid disturbances while maintaining small-signal stability.

current limiting↗

Precise Motion Control of Hybrid Hydraulic Electric Architecture (HHEA)

Off-highway heavy-duty vehicles have been long-standing users of hydraulic systems for power transmission and control. However, traditional hydraulic systems suffer from significant energy losses which lead to increased operating costs and a larger carbon footprint due to higher CO2 emissions. Improving the efficiency of these mobile machines is crucial not only for reducing their environmental impact but also for saving billions of dollars in operating costs. Currently, the state-of-the-art Load Sensing Architecture uses throttling valves for control, which significantly reduces its efficiency and does not recuperate energy from over-running loads. Researchers have developed several architectures such as Common Pressure Rail systems, Displacement Control, STEAM, and Electrohydraulic Architecture to improve the efficiency of off-road mobile machines. However, each of these architectures has its drawbacks. To increase system efficiency and take advantage of electrification benefits, our research group has developed a novel Hybrid Hydraulic-Electric Architecture (HHEA). The HHEA can significantly improve efficiency, decrease the size of electrical components, and maintain control performance. This new architecture has the potential to revolutionize the off-highway mobile machine industry and lead to a more sustainable future. The HHEA uses a set of common pressure rails to provide the majority of power to the actuators via power-dense hydraulics and uses electric motors for precise control and power modulation. In the context of off-road mobile machines, energy savings are undoubtedly important but it is equally important to consider the machines’ ability to perform tasks with precision and accuracy according to given commands. Therefore, precise motion control is of utmost importance to maintain the utility of Hybrid Hydraulic-Electric Architecture (HHEA). The HHEA presents a unique challenge to motion control due to the discrete pressure changes that occur when the system switches between selected pressure rails. These changes are made to minimize system inefficiencies or to keep the system within the torque capability of the electric motor. Hence, it is important to solve the motion control challenges for HHEA. This thesis aims at developing an effective motion control strategy for HHEA. The dissertation presents a two-tiered control strategy for HHEA, comprising a high-level and a low-level controller. The primary responsibility of the high- level controller is to optimize energy efficiency by making informed pressure rail selections. On the other hand, the low-level controller is focused on achieving precise motion control of the HHEA, which is crucial for realizing the desired reference trajectories. To achieve this, the low-level controller utilizes a passivity-based backstepping integral controller as the nominal control, which handles the motion control between two pressure rail switches. Additionally, a separate least norm controller is utilized as a transition controller to manage motion control during pressure rail transitions. The effectiveness of the combined control strategy is demonstrated through experiments conducted on two hardware-in-the-loop testbeds. Furthermore, the HHEA is installed on the boom and stick actuators of a backhoe arm to build a Human-in-the-Loop system that a human operator can control. A real-time rail switching algorithm is developed to determine pressure rail switching based on present duty cycle information from the operator. Modifications have been made to the human-machine interface to achieve more intuitive control. Modifications include performing control in the task-oriented coordinates, incorporating pressure feedback to enhance control with physical interaction, and using velocity field control to simplify multi-degree-of-freedom tasks and to enable novice operators to perform them with reduced risk, improved efficiency, and productivity. The research in this dissertation makes significant contributions to the field of off-road mobile machine control, providing a novel and effective control strategy for the HHEA, and demonstrating the potential for simplified machine operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Electronics for Electrolyzer Applications to Enable Grid Services

The Power Electronics for Electrolyzer Applications to Enable Grid Services project aims to develop smart converter for dedicated electrolyzer applications to enable grid services via standardization of control interfaces between hydrogen electrolyzer system low-level controls and power converter controls. The project provides additional revenue source for electrolyzer through participation in grid services and reduces the cost of deployment and controls integration through standardization and risk due to supply-chain issues. It also enables the adoption of green hydrogen via standardizing the integration of energy storage, renewables, and distributed energy resources. Furthermore, the work provides a controlled validation environment to evaluate scalable integration solution for hydrogen production technologies, improves overall reliability and maintainability of the electrolyzer system for grid applications, and directly contributes to DOE HFTO's "Hydrogen Shot" goal.

energy transitions↗

Self-tuning wave energy converter (WEC) controller for changing sea states

Systems and methods for a WEC controller that uses a self-tuning proportional-integral control law prescribing motor torques to maximize electrical power generation and automatically tune the controller to maximize power absorption. In an embodiment, the controller may be part of any resonant WEC system. The control law relies upon an identified model of device intrinsic impedance to generate a frequency-domain estimate of the wave-induced excitation force and measurements of device velocities. The control law was tested in irregular sea-states that evolved over hours (a rapid, but realistic time-scale) and that changed instantly (an unrealistic scenario to evaluate controller response).

Bacelli, Giorgio↗

Multiscale simulation of integrated energy system and electricity market interactions

Accelerating the deep decarbonization of the world's electric grids requires the coordination of complex energy systems and infrastructures across timescales from seconds to decades. Here, we present a new multiscale simulation framework that integrates process- and grid-centric modeling paradigms to better design, operate, and control integrated energy systems (IESs), which combine multiple technologies, in wholesale energy markets. Traditionally, IESs are analyzed with a process-centric paradigm such as levelized cost of electricity (LCOE) or annualized net revenue, ignoring important interactions with electricity markets. This framework explicitly models the complex interactions between an IES's bidding, scheduling, and control decisions and the energy market's clearing and settlement processes, while incorporating operational uncertainties. Through two case studies, we show the importance of understanding and quantifying complex resource-grid interactions. In case study 1, we demonstrate that optimized bidding from one resource shifts the profit distribution for all energy systems in the market. This result suggests new and more flexible IES technologies can disrupt the economics of all market participants, possibly leading to accelerated retirements of less flexible resources. Interestingly, the optimized bidding has little impact on grid-level aggregate statistics, such as total generation costs and renewable penetration rate. While aggregate modeling strategies may remain valid under some IES adoption scenarios for analysis focused on regional outcomes, direct comparisons of IES technologies at specific locations without considering these interactions may lead to misleading or incorrect conclusions. In case study 2, we consider the design and flexible operation of IESs that hybridize conventional generators with energy storage. Through a sensitivity analysis, we find that as the size of the storage system increases, the total number of start-ups for coal- and natural gas-based IESs reduced by 25% and 33.6%, and the total thermal generator ramping (i.e., mileage) reduced by 86.5% and 62.5%, respectively. This shows the primary benefit of storage may not be reduced operational costs (which do not change significantly) but fewer start-ups and less ramping, which may greatly simplify the design, operation, and control of carbon capture systems. The new modeling and optimization capabilities from this work enable the coupling of rigorous, dynamic process models with grid-level production cost models to quantitatively identify the nuanced interdependencies across these vast timescales that must be addressed to realize clean, safe, and secure energy production. Moreover, the proposed general multiscale simulation framework is applicable to all IES technologies and can be easily extended to consider other energy carriers (e.g., hydrogen, ammonia) and energy infrastructures (e.g., natural gas pipelines).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced HVAC Humidity Control for Hot-Humid Climates

During this project we develop and validate a cost-effective, integrated control solution to improve humidity control and comfort for energy-efficient homes in hot-humid climates. This study focuses on developing a strategy that is effective, field tested, and practical for builders to install with minimal disruption to standard practices. A successful solution would simplify the transition to high-performance humidity control and be the basis for design and installation guidance. By relying on the central system as a starting point, the strategy employed minimizes system complexity and cost for builders, while improving comfort and operating cost for homeowners. The solution strategy was to coordinate the cooling, dehumidification, and ventilation functions of central, ducted HVAC systems to better control indoor humidity, improve occupant thermal comfort, and capture energy savings. The primary strategic goals were to: (1) optimize dehumidification by the central air-conditioning system, particularly during part-load conditions, using conventional equipment with modified control settings and lower system airflows; (2) maximize ventilation during heating/cooling on-cycles, to “bank” and condition outdoor ventilation air, and minimize ventilation during off-cycles; (3) quantify the effectiveness and energy impact of the dehumidification and ventilation strategies, while identifying a metric that would be useful to evaluate latent effectiveness. For the test houses in our study, located in Richmond Hill, Georgia; Houston, Texas; and Monroe, Louisiana we observed: (1) the indoor humidity did not exceed 60% RH during the monitored cooling season for 99% of the time in Richmond Hill, 96% of the time in Houston, and 90% of the time in Monroe; (2) the dehumidification strategy improved the steady-state latent capacity of the HVAC system at design conditions by 16% to 49% at the Houston test house and by 28% to 71% at the Monroe test house, depending on which mode the system was operating in; and (3) the good results at the test houses were primarily due to the amount of time the air-conditioning system operated in ramping or dehumidification modes, or both, particularly during the early cooling season. This study demonstrates that air conditioners or heat pumps with a single-stage compressor can provide good humidity control without the need for a two-stage or variable-stage compressor system. The airflow and control settings for ramping and dehumidification modes are critical to control indoor humidity in hot-humid climates, particularly during part-load and shoulder season conditions. The dehumidification strategy used in this study did not jeopardize the mechanical reliability of the cooling equipment. The strategies used in this study are applicable across various equipment brands, models, and efficiency levels, and also applicable to a broad range of homes in hot-humid climates. Results will vary by specific equipment, location, and house configuration and construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Wind farm flow control: prospects and challenges

Abstract. Wind farm control has been a topic of research for more than two decades. It has been identified as a core component of grand challenges in wind energy science to support accelerated wind energy deployment and to transition to a clean and sustainable energy system for the 21st century. The prospect of collective control of wind turbines in an array, to increase energy extraction, reduce structural loads, improve the balance of systems, reduce operation and maintenance costs, etc. has inspired many researchers over the years to propose innovative ideas and solutions. However, practical demonstration and commercialization of some of the more advanced concepts has been limited by a wide range of challenges, which include the complex physics of turbulent flows in wind farms and the atmosphere, uncertainties related to predicting structural load and failure statistics, and the highly multi-disciplinary nature of the overall design optimization problem, among others. In the current work, we aim at providing a comprehensive overview of the state of the art and outstanding challenges, thus identifying the key research areas that could further enable commercial uptake and success of wind farm control solutions. To this end, we have structured the discussion on challenges and opportunities into four main areas: (1) insight in control flow physics, (2) algorithms and AI, (3) validation and industry implementation, and (4) integrating control with system design (co-design).

Meyers, Johan (ORCID:0000000228284397)↗

Connected Thermostat Alternatives for Room Air Conditioners and Minisplit Heat Pumps

The availability of smart, connected thermostats has improved climate control, energy efficiency, and grid demand-response programs for central HVAC systems. However, a significant gap exists in addressing integrated control systems for point-source heating and cooling systems such as window air-conditioners (window ACs) and mini-split heat pumps (MSHPs). This report examines the emerging market of third-party connected thermostats tailored for these systems, focusing on their effectiveness, reliability, and potential barriers to adoption.This study evaluates several commercially available products designed for room ACs and MSHPs through a series of laboratory tests. While these infrared-based (IR-based) thermostats offer remote temperature control and scheduling via mobile apps, our findings reveal that none are seamless, with reliability of basic functions being a critical factor. Promising features include integration of indoor air quality metrics and time-of-use pricing, but the latter are not yet available in the U.S. Barriers to broad user acceptance include non-seamless setup processes, challenges in thermostat placement, and unclear product differentiation. There is a pressing need for research and development in enabling MSHPs and central thermostats to coordinate, enhancing energy savings and comfort in retrofit applications. This study underscores the importance of further innovation in connected thermostat technology to address the diverse needs of single-zone HVAC systems and promote efficient energy management in households.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Robust Decentralized Secondary Control Scheme for Inverter-based Power Networks

Inverter-dominated microgrids are quickly becoming a key building block of future power systems. They rely on centralized controllers that can provide reliability and resiliency in extreme events. Nonetheless, communication failures due to cyber-physical attacks or natural disasters can make autonomous operation of islanded microgrids challenging. This paper examines a unified decentralized secondary control scheme that is robust to inverter clock synchronization errors and can be seamlessly applied to grid-following or grid-forming control architectures. The proposed scheme overcomes the well-known stability problem that arises from parallel operation of local integral controllers. Theoretical guarantees for stability are provided along with criteria to appropriately tune the secondary control gains to achieve good frequency regulation performance while ensuring fair power sharing. The efficacy of our approach is demonstrated through simulations on a 5-bus microgrid with four grid-forming inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Closed-Loop Control of Active Nematic Flows

Stabilizing and shaping autonomous flows of active fluids is a fundamental challenge and a prerequisite for applications. We embed a light-responsive microtubule-based nematic in a proportional-integral control loop that adjusts the applied light intensity in response to real-time measurements of the spatially averaged flow speed. The self-regulating hardware-software-wetware system maintains a target flow speed against external or internal perturbations, including protein aging and aggregation, sample-to-sample variability, and temperature variation. Varying the controller’s gains reveals antagonistic roles between feedback and intrinsic processes, leading to nontrivial dynamics observed in fluctuation spectra. In particular, oscillations emerge from the interplay between the controller, motor binding kinetics, and active hydrodynamic relaxation. Accounting for the underlying binding timescale, our coarse-grained model and nematohydrodynamics simulations corroborate these observations. This work provides insight into the coupled dynamics of controlled active matter, laying the foundation for spatiotemporal patterning of active stress to generate and stabilize new dynamical configurations.

Active nematics↗

Closed-loop control of active nematic flows

Stabilizing and shaping autonomous flows of active fluids is a fundamental challenge and a prerequisite for applications. We embed a light-responsive microtubule-based nematic in a proportional-integral control loop that adjusts the applied light intensity in response to real-time measurements of the spatially averaged flow speed. The self-regulating hardware/software/wetware system maintains a target flow speed against external or internal perturbations, including protein aging and aggregation, sample-to-sample variability, and temperature variation. Varying the controller’s gains reveals antagonistic roles between feedback and intrinsic processes, leading to nontrivial dynamics observed in fluctuation spectra. In particular, oscillations emerge from the interplay between the controller, motor binding kinetics, and active hydrodynamic relaxation. Accounting for the underlying binding timescale, our coarse-grained model and nematohydrodynamics simulations corroborate these observations. This work provides insight into the coupled dynamics of controlled active matter, laying the foundation for spatiotemporal patterning of active stress to generate and stabilize new dynamical configurations.

Nishiyama, Katsu [Brandeis Univ., Waltham, MA (Uni↗