Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “insulation installation quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

41 records · Page 3

Real-Time X-ray Radiography Diagnostics of Components in Solid Rocket Motors

Solid rocket motors (SRMs) typically use nozzle materials which are required to maintain their shape as well as insulate the underlying support structure during the motor operation. In addition, SRMs need internal insulation materials to protect the motor case from the harsh environment resulting from the combustion of solid propellant. In the nozzle, typical materials consist of high density graphite, carbon-carbon composites and carbon phenolic composites. Internal insulation of the motor cases is typically a composite material with carbon, asbestos, Kevlar, or silica fibers in an ablative matrix such as EPDM or NBR. For both nozzle and internal insulation materials, the charring process occurs when the hot combustion products heat the material intensely. The pyrolysis of the matrix material takes away a portion of the thermal energy near the wall surface and leaves behind a char layer. The fiber reinforcement retains the porous char layer which provides continued thermal protection from the hot combustion products. It is of great interest to characterize both the total erosion rates of the material and the char layer thickness. By better understanding of the erosion process for a particular ablative material in a specific flow environment, the required insulation material thickness can be properly selected. The recession rates of internal insulation and nozzle materials of SRMs are typically determined by testing in some sort of simulated environment; either arc-jet testing, flame torch testing, or subscale SRMs of different size. Material recession rates are deduced by comparison of pre- and post-test measurements and then averaging over the duration of the test. However, these averaging techniques cannot be used to determine the instantaneous recession rates of the material. Knowledge of the variation in recession rates in response to the instantaneous flow conditions during the motor operation is of great importance. For example, in many SRM configurations the recession of the solid propellant grain can drastically alter the flow-field and effect the recession of internal insulation and nozzle materials. Simultaneous measurement of the overall erosion rate, the development of the char layer, and the recession of the char-virgin interface during the motor operation can be rather difficult. While invasive techniques have been used with limited success, they have serious drawbacks. Break wires or make wire sensors can be installed into a sufficient number of locations in the charring material from which a time history of the charring surface can be deduced. These sensors fundamentally alter the local structure of the material in which they are imbedded. Also, the location of these sensors within the material is not known precisely without the use of an X-ray. To determine instantaneous recession rates, real-time X-ray radiography (X-ray RTR) has been utilized in several SRM experiments at PSU. The X-ray RTR system discussed in this paper consists of an X-ray source, X-ray image intensifier, and CCD camera connected to a capture computer. The system has been used to examine the ablation process of internal insulation as well as nozzle material erosion in a subscale SRM. The X-ray source is rated to 320 kV at 10 mA and has both a large (5.5 mm) and small (3.0 mm) focal spot. The lead-lined cesium iodide X-ray image intensifier produces an image which is captured by a CCD camera with a 1,000 x 1,000 pixel resolution. To produce accurate imagery of the object of interest, the alignment of the X-ray source to the X-ray image intensifier is crucial. The image sequences captured during the operation of an SRM are then processed to enhance the quality of the images. This procedure allows for computer software to extract data on the total erosion rate and the char layer thickness. Figure 1 Error! Reference source not found.shows a sequence of images captured during the operation the subscale SRM with the X-ray RTR system. The X-rayTR system, alignment procedure, uncertainty determination, and image analysis process will be discussed in detail in the full manuscript.

Cortopassi, A. C.↗

Photovoltaic Cable Connectors: A Comparative Assessment of the Present State of the Industry

The consequences of failure for balance-of-systems components (such as photovoltaic (PV) cable connectors) include offline module string(s); low system voltage; arc, ground, insulation, and overtemperature faults; triggered fuse(s); system shutdown; and fire. The degradation modes for connectors are studied here through an industry survey and its subsequent examination, which are compared with field-degraded specimens. A total of 117 specimens were obtained from a variety of locations and climates or accelerated tests. A failure analysis for connectors from PV installations was developed (and applied to 54 specimens), including nondestructive examinations (photography, a custom resistance-current scan, and X-ray computed tomography) and destructive examinations (featuring milling of the external plastic, extraction of the internal convolute spring, and potting and polishing in cross section). Surface and through-thickness composition of the metal pins and springs was quantified using scanning electron microscopy with energy-dispersive X-ray spectroscopy. Fourier transform infrared spectroscopy was used to verify the base polymer materials and compare the chemical structure of the connector body, bushing, end nut, and o-ring. Thermogravimetric analysis and differential scanning calorimetry were used to further verify the degradation of the same polymeric components.

cable connectors↗

Photovoltaic Cable Connectors: A Comparative Assessment of the Present State of the Industry [Slides]

The consequences of failure for balance of systems (BoS) components (such as PV cable connectors) include offline module string(s); low system voltage; arc, ground, insulation, and over-temperature faults; triggered fuse(s); system shutdown; and fire. The degradation modes for connectors are studied here through an industry survey and its subsequent examination, which are compared to field-degraded specimens. 117 specimens were obtained from a variety of locations and climates or accelerated tests. A failure analysis for connectors from PV installations was developed (and applied to 54 specimens) including nondestructive examinations (photography, a custom resistance-current scan, and X-ray computed tomography) and destructive examinations (featuring milling of the external plastic, extraction of the internal convolute spring, and potting and polishing in cross-section). Surface and through-thickness composition of the metal pins and springs was quantified using scanning electron microscopy with energy-dispersive X-ray spectroscopy. Fourier-transform infrared spectroscopy was used to verify the base polymer materials and compare the chemical structure of the connector body, bushing, end nut, and o-ring. Thermogravimetric analysis and differential scanning calorimetry were used to further verify the degradation of the same polymeric components. Updated from 2023 NIST/UL Workshop on Photovoltaic Materials Durability (website: https://events.ul.com/WPMogn?rt=aAuoWsl4E0KaORLCMeOgfA) and 2024 PVRW workshop (https://pvrw.nrel.gov/past-proceedings).

14 SOLAR ENERGY↗

Correlation of Qualification and Accelerated Testing with Field Degradation

Qualification testing of solar photovoltaic (PV) modules per IEC 61215 standard encompasses a set of well-defined accelerated stress tests (irradiation, environmental, mechanical and electrical) with strict pass/fail criteria based on functionality/performance, electrical and mechanical safety, and visual requirements. The qualification testing does not identify all the possible reliability failures or durability issues witnessed in the actual field. However, it does identify the major/catastrophic design quality issues (infant mortality), which could occur early in a module’s field life. Unfortunately, in the industry, there is no consensus-based standard or protocol available to validate manufacturers’ warranty period claims based on the end-of-life wear-out failure mechanisms. Being able to predict the field degradation rates and lifetime using mode-specific accelerated tests on moderately field-aged modules, for example 10 years, for certain commonly occurring degradation modes would be a powerful contribution to all the stakeholders of the PV industry. There is a need to formulate guidelines to find the correlation of accelerated testing with field degradation for individual degradation modes observed in the field. Potential approaches to fulfill this need were experimented in this project and are presented in this report. Two of the most commonly seen degradation modes – encapsulant browning and solder bond thermomechanical fatigue – are addressed in this report through presenting the accelerated testing methods and physical modelling approaches. Two accelerated test methods (UV and thermal cycling) were designed to induce the wear-out mechanisms in the modules and not infant mortality failures. To focus on the wear-out failure modes, the tests were performed on field-aged modules, instead of fresh modules, with known degradation rates and degradation modes. The degradation rates were measured based on the degradation rates of individual cell parameters (short-circuit current, I sc and series resistance, R s ) instead of the degradation rate of maximum power (P max ) which cannot be used to study any specific/limited degradation mode as the P max degradation could be caused by many different degradation modes. The key characteristic parameter considered for encapsulant discoloration and solder bond degradation is I sc and R s , respectively. The developed physical models/equations relating the testing degradation data and field weather data were utilized to determine the acceleration factor (AF) and to predict the degradation rate for a specific degradation mode of PV modules installed in two different climates, Arizona (hot) and New York (cold). The predicted degradation rates for encapsulant browning and solder bond degradation have also been validated against the actual measured field degradation rates. UV testing cost reduction: To determine acceleration factor, single UV chamber was used for accelerated UV testing at three different temperatures simultaneously, instead of three chambers for three temperatures (or one chamber sequentially which is an extremely time-consuming approach). A passive heating approach was successfully used to achieve and maintain multiple temperatures in the accelerated UV chamber. Foam insulation boards of varying thicknesses were utilized to obtain three different temperatures for UV testing. However, these foam materials tend to disintegrate in the presence of moisture. To alleviate this problem, silicone heating blankets with temperature controls and humidifier can be used if the UV testing is to be performed under hot-humid conditions instead of conventional hot-dry conditions. Thermal cycling testing cost reduction: Single thermal cycling chamber was used for accelerated thermal cycling testing at three different upper temperatures simultaneously, instead of three chambers for three upper temperatures (or one chamber sequentially which is an extremely time-consuming approach). An active heating approach based on silicone heating blankets was successfully used to achieve and maintain multiple upper temperatures in the accelerated thermal cycling chamber. Such blankets provide stable temperature control and thereby more reliable and repeatable for replicate experiments.

14 SOLAR ENERGY↗

Strengthening Retrofit Markets for Comprehensive Savings in Multifamily Buildings (Interim Final Report)

Energy efficiency is vitally important in Maine. Nearly 70% of Maine households rely on fuel oil as their primary energy source for home heating, a higher share than in any other state. Coupled with the state's long, cold winters, Maine's dependence on oil renders homeowners particularly vulnerable to fluctuating fuel costs. With $\$$4.5 million in seed funding from the Energy Department's Better Buildings Neighborhood Program, the Governor's Energy Office (GEO), through Efficiency Maine Trust (the Trust), is spurring Maine landlords to lower their monthly energy bills and improve comfort for their tenants during the state's cold winter months and increasingly warmer summers. Maine's aging multifamily housing stock can be expensive to heat and costly to maintain. It is not unusual to find buildings with little or no insulation, drafty windows, and significant air leaks, making them ideal candidates for energy efficiency upgrades. Maine modeled its Multifamily Efficiency Program (MEP) after the state's highly successful Home Energy Savings Program (HESP) for single-family homes. HESP provided cash incentives and financing opportunities to owners of one-to four-unit structures, which resulted in thousands of energy assessments and whole-house energy upgrades in 225 communities. Maine's new MEP multifamily energy efficiency upgrade and weatherization initiative focuses on small to medium-sized (i.e., five to 20 units) apartment buildings. The program's energy efficiency upgrades will provide at least 20% energy savings for each upgraded multifamily unit. The Trust’s MEP relies on a network of approved program partners who help move projects through the pipeline from assessment to upgrade. MEP has two components: benchmarking and development of an Energy Reduction Plan (ERP). Using the ENERGY STAR® Portfolio Manager benchmarking tool, MEP provides an assessment of current energy usage in the building, establishes a baseline for future energy efficiency improvements, and enables tracking and monitoring of future energy usage at the building— all at no cost to the building owner. The ERP is developed by a program partner using either the Trust’s approved modeling or prescriptive tools; it provides detailed information about the current energy related conditions in the building and recommends energy efficiency, health, and safety improvements. The Trust's delivery contractor provides quality assurance and controls throughout the process. Through this effort, MEP's goal is to establish a self-sustaining, market-driven program, demonstrating the value of energy efficiency to other building owners. The increasing value of properties across the state will help incentivize these owners to continue upgrades after the grant period has ended. Targeting urban areas in Maine with dense clusters of multifamily units—such as Portland, Lewiston- Auburn, Bangor, and Augusta—MEP engaged a variety of stakeholder groups early on to design its multifamily program. Through direct emails and its website, program officials invited lending institutions, building professionals, engineering firms, equipment distributors, and local property owners associations to attend open meetings around the state to learn about the goals of the multifamily program and to help define its parameters. These meetings helped program administrators understand the diversity of the customer base: some owners are individuals with a single building, while other owners are groups of people or management companies with an entire portfolio of multifamily buildings. The diversity of the customer base notwithstanding, owners see MEP as an opportunity to make gains in their respective properties. Consistently high turnouts at stakeholder meetings fueled greater customer interest as awareness of the program spread through word of mouth. The program also gained traction by utilizing the program partner networks and building on the legacy of the Trust’s successful HESP for single-family residences. MEP offers significant incentives for building owners to participate in the upgrade program. Wholebuilding benchmarking services are available to most multifamily housing buildings free of charge. The service provides the building owner with an assessment of the building's current energy efficiency as compared to other multifamily buildings on a national scale, establishes a baseline to measure future improvements, and enables owners to track monthly energy consumption using the ENERGY STAR Portfolio Manager. Once the benchmarking process is complete, the program links building owners with approved program partners (e.g., energy professionals, home performance contractors) to identify and implement specific energy-saving opportunities in the building. Program partners can also provide project quotes with estimated financing incentives and payback period calculations that enable building owners to make informed decisions. What's more, the Trust provides two financial incentives for successful completion of program milestones. The first is a per-unit incentive for completion of an approved ERP (i.e., $\$$100 per unit if a prescriptive path is followed, and $\$$200 per unit for a modeled ERP). Upon final inspection of the installed project scope of work, an incentive of $\$$1,400 per unit or 50% of installed cost—whichever is less—is paid. The Trust originally established a $\$$1 million loan-loss reserve fund (LLRF) to further enhance financing opportunities for qualified multifamily building owners. This funding mechanism was designed to connect building owners with lenders that retain the mortgages for their properties and encourages the lenders to offer financing for energy efficiency improvements. However, there has been no interest in the LLRF and therefore the LLRF has been reduced. Ultimately, MEP plans to build an online tool for building owners to assess opportunities to make upgrades in their multifamily units. The tool will include a performance rating system to provide a way for building owners to more easily understand energy use in their building, and how it could be improved with energy efficiency upgrades. Prospective tenants will also be able to use the rating system to make informed decisions about where to rent. Furthermore, the rating can be incorporated into real estate listings as a way for prospective home buyers and the real estate financial community to evaluate a home's operating costs. The Trust’s MEP has identified the state's most experienced energy professionals, vendors, suppliers, and contractors that install energy efficiency equipment in the multifamily sector to be qualified program partners. To be eligible for partnership, energy assessment professionals and contractors are required to have demonstrated experience in the multifamily sector and hold associated professional certifications, such as Building Operator Certification (BOC), Certified Energy Manager (CEM), Professional Engineer (PE), or Building Performance Institute (BPI) Multifamily Building Analyst. Widespread program interest has enabled the Trust to redirect funds that might otherwise be needed for program promotion to building capacity through contractor training. In addition to boosting professional training and certification opportunities, MEP teaches its partners how to market the multifamily program to prospective multifamily homeowners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗